Loading...
HomeMy WebLinkAboutRevisions; Proposed Utility StructureOFFICE USE ONLY: DATE FILED: 2 f PERMIT # REVISION FEE: RECEIPT # 017 A PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION RECEIVED 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982-5652 APR 2 8 ef?I (772) 462-1553 Permitting i)cp tment APPLICATION FOR BUILDING PERMIT REVISIONSst- Lucie csunty PROJECT INFORMATION LOCATION/SITE ADDRESS: DETAILED DESCRIPTION OF PROJECT CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: PHONE (DAYTIME): STATE: OWNER/BUILDER INFORMATION: NAME: 140 eyu ca, G+CG uj,- 0 ^ 6T-/7c/ } ADDRESS: 1 2 k-5 d3 �� �c t CITY: ,Z%- STATE: PHONE (DA TIME: 7 7 S = ARCHITECT/ENGINEER INFORMATION: NAME: 8 eC 1,4-f ADDRESS: &() cc CITY: k C, - � PHONE (DAYTIME): SLCCC.• 9123109 Revised 06130117 ST. LUCIE CO CERT. #: ZIP: FAX: 31.3 a ZIP: '-6 `) `( -;�;z FAX: 7 7 i =- �13 5 I- D a- STATE: i== L- ±-.41.. ZIP: , 7 ;L 0 APPROVED PRODUCTS LIST GENERAL NOTES:. OCCUPANCY GROUP: U . 1, ; .THESE PLANS PERTAIN ONLY TO. THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING, AND BASE CONSTRUCTION TYPE: II-B. APPROVAL RAIL ANCHORAGE. OTHER DESIGN.ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL,-INGRESS/EGRESS, PROPERTY SET -BACKS, ' PRODUCT C`ATEGORY,. SUB CATEGORY MANUFACTURER FINISH FLOOR ELEVATION AND SLOPE; OR OTHER LOCAL'ZONIN G REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS, RISK CATEGORY: I No. B DATE 2: THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/ST:ORAGE BUILDINGS (RISK CATEGORY I) CAPA6LE OF SUPPORTING DEAD LOAD BUILDING ENCLOSURE TYPE: ENCLOSED. OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY'ADDRESSED HEREIN, INCLUDING -DOORS,' STRUCTURAL COMPONENTS, ROOF DECK CAROLINA CARPORTS; INC.: FL6596.1-R6 . wlNDowS; OR OTHER COMPONENTS NOT -LISTED IN -THE FBC APPROVED PRODUCTS, LIST (THIS SHEET), ANDNOT PROVIDED AND INSTALLED BY ; WIND EXPOSURE CATEGORY: C ' 26 Gauge AG Panel. 12/15/20 CAROLINA CARPORTS; INC:, WHICH EXERT ADDITIONAL.LOADS ONTHE STRUCTURE,SHALL.BE AT THE OWNER'S RISK. BECHTOL ENGINEERING:AND TEST l NG, INC., SHALL NOT 13E RESPONSIBLE FOR STRUCTURALDAMAGE'OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS.- ULTIMATE WIND SPEED (MPH): . 150 STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA, CARPORTS, INC. • Fl 6702.1-R6 3. ALL STEEL TUBING SHALL BE 50.KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR3TAINLESS STEEL. NOMINAL DESIGN WIND SPEED (MPH): 116.. . 26:Gauge AG Panel :.. 12/15/20 • . q, ALL COMPONENTS AND CLADDING SHALL.BE INSTALLED ACCORDING TO MAN CTURER'S INSTALLATION INSTRUCTIONS N N I MANUFACTURERS MEAN ROOF HEIGHT (FEET):. 17 86 . , 5. ALL FIELD FRAMING CONNECTIONS SHALL BE_#12-14 x 3/4" SELF DRILLING SCREWS. WITHOUT CONTROL SEAL WASHER..ALL SHOP FRAMING ROOF ANGLE (DEGREES): - 14.0. - CONNECTIONS SHALL BE WELDED.. INTERNAL PRESSURE COEF CIENT• A S COEFFICIENT: +0:18 ! -0.18 -6. -BASE RAIL GROUND ANCHOR REQUIREMENTS: ONE WITHIN 6' OF EVERY POST LOCATION, AND BOTH SIDES OF OPENINGS WHERE BASE RAIL IS - ABSENT. DESIGN PRESSURES (PSF): 7. B DG POST/RAFTER RACING: BRACE ON EVERY ROSTIRAFTER CONNECTION, EXCEPT FOR END WALLS.AN ABLE ENDS. ROOF; . • ZONE 1; +16.0 / -17.5 ". 8. .14, GA FRAMING: 2-1/2" x;2,1/2" TUBE STEEL (TS) WITH 2.1/4" x 2' 1/4". TS NIPPLES L ZONE 2e: +16.0 /, -17.5 4 2 12 GA FRAMING: 2 1/ " z 2 1/4" TS WITH 2"'x: " TS.NIPPLES. ZONE 2n:_ . .. ZONE 2r. +16.0 / -30.4 ZONE 3e: ' +16.0 /--30.4 ZONE 3r: +16.0 / 51:1 WALLS: ZONE'4• +22.8 ! -25A ZONE 5. +22.8 4 / -25. NOT . . ' 14 E GA.FRAMING METAL FRAMING AND SIDING PREFABRICATED BY CAROLINA- CARPORTS, INC. - P.O. BOX 1263 ... DOBSON, NORTH CAROLINA 27017 THESE ENGINEERING DRAWINGS ARE THE PROPERTY OF BECHTOL ENGINEERING 8 TESTING, INC. AND CAROLINA CARPORTS, INC. _THESE DRAWING MAY NOT. BE REPRODUCED - WITHOUT THE: WRITTEN CONSENT OF BECHTOL ENGINEERING 8 TESTING, INC., AND-CAROLINA CARPORTS,.INC. THIS IS TO.CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS HEREIN HAVE BEEN PREPARED.BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND,AREIN ACCORDANCE WITH THE REQUIREMENTS OF , SECTION 1609 OF THE FLORIDA BUILDING CODE, SEVENTH EDITION (2020). S R H 'BF N • BECHTOL ENGINE ERI N 3,g53C TE PIO. .665 WEST NEW YORK AVE C FRONT'AND. REAR_ ELEVATION LEFT AND RIGHT: SIDE ELEVATION DELAND, FLORIDA 32720 . SCALE: 1/8" = 1' .. .. SCALE: 1/8" = T- .� += • - ;•�w�` Thomas.Be oI,P.E. ��. Florida Lice 538 ��� FCORIOP: V. �\ /ONA1- PROPOSED UTILITY STRUCTURE 4600 GRADY DRIVE FORT PIERCE, 'FLORIDA 3/26/2021 BECHTOL ENGINEERING �""� . NM BG NTS AND'7E677NG, br— a cw0CM.EWAR WAt A DMMU"T�emMMRe MKB `"OLND G21001 o.mrdAWq„ rcom�. rcaovEu TB SHEET 1 OF 2 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO PURLINS ACCORDING TO 26 GA. GALVANIZED METAL WALL PANELS - 1_1/2" 18 GAUGE FURRING CHANNEL FASTENED TO EACH RAFTER WITH.. MANUFACTURER'S INSTALLATION INSTRUCTIONS FASTENED TO POSTS AND GIRTS ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS _ (2) #12=14 x 3/4" SELF -DRILLING FASTENER SPACED NOT MORE THAN 48" O.C. FULL 6" WELD . 40 . .. BOTH SIDES .. 12 .. W. WELD ALL WEB CONNECTIONS, . ALL SIDES 6' 2^. 1 1/2" 18 GAUGE FURRING CHANNEL FASTENED 16' TOEACFI RAFTER WITH (2) #12 14 x 3/4" SELF -DRILLING FASTENER SPACED NOT MORE THAN 48.C. 0 : . / 12 GA FRAMING 4' 26 GA METAL ROOF PANEL 2' 1/2" FOR Maximum' 14 GA FRAMING 16 GAUGE B\RA30R WITHFASTENEE #1P14x3/O4SAN () GROUND ANCHOR (Typical, . TS RAFTER'RAFTS AT EACH END (4 PER B See Note 6; Sfieet 1 of2). TYPICAL. INTERIOR POST/RAFTER, FRAMING, SECTION ROOF PANEL ATTACHMENT. BRACE SECTION LEFT AND RIGHT SIDE POST/RAFTER FRAMING PLAN Not To Scale Not To.Scale SCALE: 10 =1' DRILL5/8" HOLE THROUGH BOTH BASE RAILS AND SECURE H B / F TO ANCHOR EYE WITH 1/2• \\ C P•., DIAMETER THROUGH -BOLT 2" WASHERS LONG TS. CONT. BASE RAIL Li -CHANNEL 16 GA CE BRACE ANGLE SHALL BE MIN.145°, STS 3/4" SEONIPPLES LF DRILLNGISCREWS, (4)t BECHTOL ENGINEERI D TESTM < .. 3/16" ONE ON EACH SIDE @ 3" UP FROM 605 WEST NEW YORKAVENUE— DELAND, FLORIDA 32720 •� GROUNDSURFACE �NIPPLETO RAFTER SPLICE JOINT •� TS RAFTER DBL TS RAFTER POST STATE OF •• <(!: o ^ NIPPLE TO 3/16" BASE RAIL - • R Thomas Be tol, P.E. /� �\ •• • CORIDP ••• ` G�\� EYE ANCHOR Florida Lice 538. ` \ 5/8"• ROD 48" LONG WITH 6" HELIX 8" LONG TS NIPPLE " ii "i. �� 11 I'I I I `\\\ SECURE' POST TO NIPPLE WITH ��. DBL. BASE RAIL ANCHORAGE_ Not To Scale (4) #12-14 x 3/4" SDFs RAFTER POST BOX EAVE RAFTER/POST DETAIL-. �' Not To Scale - \_DBL TS CONTINUOUS BASE RAIL END. POST/BASE RAIL CONN. N.t PROPOSED UTILITY. STRUCTURE 4600 GRADY DRIVE FORT PIERCE, FLORIDA 3/26/2021 BECHTOL ENGINEERING p""x NM NTS AND 7ESnNa Im mi measumm o�cNaru. Q+wmraerru. un wirewun remwo weemra MKB °PO1� 621001 � TB SHEET 2 OF 2