Loading...
HomeMy WebLinkAboutOakmont - 112 Island Dunes Cove, Jensen Beach-dsUES Project No: Workorder No: Report Date: 3360.1800061.0000 253829-1 12/08/2021 607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580 In-Place Density Test Report Client:OAKMONT CUSTOM HOMES, LLC UES Technician:Nakia Sutton 735 Colorado Ave, Suite 109 Stuart, FL 34494 Date Tested:12/07/2021 Project: Oakmont Custom Homes, LLC. ,Juno Beach, Palm Beach County, FL Type of Test: Area Tested:112 Island Dunes Cove, Jensen Beach - Stem Wall Footings Field:ASTM D-6938 Nuclear Gauge Method Laboratory:ASTM D1557 Modified Proctor Material: Fill Reference Datum: 0 = Bottom of Footing The tests below meet the 95% minimum compaction requirement. Test No.Location of Test Range Maximum Density (pcf) Optimum Moisture (%) Field Dry Density (pcf) Field Moisture (%) Soil Compaction (%) Pass or Fail 1 North side 0-1 ft 109.6 11.4 104.1 11.1 95 Pass 2 South side 0-1 ft 109.6 11.4 104.3 11.4 95 Pass 3 Center of footing 0-1 ft 109.6 11.4 104.5 10.9 95 Pass Remarks:Permit: 2004-0191 Reviewed By GFA International, Inc FBPE Registry No.4930 Alex Albandoz, P.E. STATE OF FLORIDA Professional Engineer No. 92555 This item has been digitally signed and sealed by Alex Albandoz, P.E. on the date adjacent to the seal. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval. Page 1