Loading...
HomeMy WebLinkAboutApproved RevisionOFFICE USE ONLY: i DATE FILED: PERMIT # �. A05 65. IN RECEIPT # REVISION FEE: d PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982.5652 (772) 462.1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION LOCATION/SITE E, ADDRESS: DETAILED DESCRIPTION OF PROJECT REVISIONS: Providing Correct Off Ridge Vent Product Approval I I 44 I� �I�III� CONTRACTOR INFORMATION: i r STATE of FL REG./CE ST. LUCIE CO CERT. { BUSINESS NAME: 6 0 hill QUALIFIERS NAME: p N i l) i; ADDRESS: CITY: STATE: L ZIP: 3a.�5S fllll'I j= PHONE (DAYTIME): oL\- L45 j- JIM FAX: All— OWNER/BUILDER INFORMATION: i NAME: o N1a Y\ ADDRESS:-6q10 YLACta p CITY: STATE: -FL- ZIP: FfI[I i PHONE (DAYTIME: 7 5EA FAX: ARCHITECT/ENGINEER INFORMATION: ' NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: SLCCC. 9123109 Revised 0 613 0/17 Imi Florida Building Code Online 11/30/21, 1:03 PM BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats & Facts dprba �I Product Approval 1 USER: Public User Product Approval Menu > Product or An-bUUon Search > AMliCatipn ust > Application Detail FL # FL16918-R3 Application Type Revision Code Version 2020 Application Status Approved Comments Archived M...— Ka Publications Contact Us BCIS Site Map Links Search Product Manufacturer L.V. Thompson, Inc. dba Thompson Architectural Metals Company (TAMCO) Address/Phone/Email 5015 East Hillsborough Ave. Tampa, FL 33610 (813)248-3456 tony@gometalroofing.com Authorized Signature Tony Christman tony@gometalroofing.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Roofing Accessories that are an Integral Part of the Roofing System Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Zachary R. Priest the Evaluation Report Florida License PE-74021 Quality Assurance Entity PRI Construction Materials Technologies, LLC Quality Assurance Contract Expiration Date 09/09/2026 Validated By Steven M. Urich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL1 1 _93_CCI_LVT14001.3a 2020 FB.Q Eval Off -Ridge Vent final.odf Referenced Standard and Year (of Standard) Standard Year ASTM E 330 2014 TA5 100(A) 1995 hitps://floridabuildiTig.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvBwYu9TrZNmOShR%2fJYsAs12bp5hV7KCmzdOsMAnQLRaT9A%3d%3d Page 1 of 3 Florida Building Code Online 11/30/21, 1:03 PM Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 09/16/2020 09/17/2020 09/22/2020 12/15/2020 Surnmary of Products FL t Model, Number or Name Description 16918.1 TAMCO Flat Top Off -Ridge Vent with 26 ga. static roof ventilator with baffle Baffle for Tile Limits of Use Installation Instructions Approved for use In HVHZ: Yes FL16918 R3 fI LVT14001 3c 2020 FBC Eval Flat Too Off - Ridge Vent flnal.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL16918_113AE_LVT14001.3c 2020 FBC Eval Flat Too Vent final.odf Ridge Vent Created by Independent Third Party: Yes 16918.2 TAMCO Gooseneck Vent 26 ga. Limits of Use Installation Instructions Approved for use In HVHZ: No FL16918 R3 II LVT14001.3d 2020 FBC Eval Gooseneck Vent nonHVHZ final.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: +0/-52.5 Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL16918_R3_AE LVT14001.3d 2020 FBC Eval Gooseneck Vent nonHVHZ final.odf Created by Independent Third Party: Yes 16918.3 TAMCO Off -Ridge Roof Vent with 26 ga. static roof ventilator with Integrated baffle same Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16918 R3 II LVT14001.3a 2020 FBC Eval Off -Ridge Vent fmal.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest 74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL16918 R3 AE LVT14001.3a 2020 FBC Eval Off -Ridge Vent f1DiLpdf Created by Independent Third Party: Yes 16918.4 TAMCO Round Top Off -Ridge Vent 26 ga. static roof ventilator with bane with Barre for Tile Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL16918 R3 II LV714001.3b 2020 FBC Eval Round Top Off - Ridge Vent final.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021 Design Pressure: N/A Created by Independent Third Party: Yes Other: See evaluation report for limits of use. Evaluation Reports FL1691fi_113_AE LVT14001.3b 2020 FBC Eval Round Top Off - Ridge Vent flnal.odf Created by Independent Third Party: Yes https:llfloridabuilding.org/pr/pr_app_dtl.aspz?param-wGEVXOwtDgvBwYugTrZNmOShR%2fJYsAs%2bp5hV7KCmzdOsMAn0LRaT9A%3d%3d Page 2 of 3 Florida Building Code Online 11/30/21, 1:03 PM Back Next Contact Us:: 2801 Blair Stone Road Tallahassee FL 32399 Phone 650487-IB24 The State of Florida Is an AA/EEO employer. Coovrioht 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Sbnemen[ Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. "Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official m mnunication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide Me Department with an email address which an be made available m the public. To determine if you are a licensee under Chapter 455, F.S., please click hem_, Product Approval Accepts: © RE] ® CKI Credit Card Safe https://floridabuilding.org/prtpr app dti.aspx?param=wGEVXQwtDgvBwYu9TrZNmOShR%2fJYsAs%2bp5hV7KCmzdOsMAnQLRaTSA%3d%3d Page 3 of 3 C T � i � Certificate of Authorization No.19824 14 K E 1K1 17520 Edinburgh Drive Tampa, FL 33647 TECHNICAL SERVICES, LLC (813)480-3421 EVALUATION REPORT FLORIDA BUILDING CODE, 7T" EDITION (2020) Manufacturer: L.V. Thompson, Inc. Issued September 16, 2020 dba Thompson Architectural Metals Company (TAMCO) 5015 E. Hillsborough Ave Tampa, FL 33610 (813)248-3456 hftp://www.tamcomelalroof,com Manufacturing Plant: Tampa, FL Quality Assurance: PRI Construction Materials Technologies (QUA9110) SCOPE Category: Roofing Subcategory: Roofing Accessories that are an Integral Part of the Roofing System Code Edition: Florida Building Code, 7' Edition (2020) including High -Velocity Hurricane Zones (HVHZ) Code Sections: 1503.5, 1523.6.5.2.13 Properties: Roof Ventilation REFERENCES Eu& Report No. Standard Year PRI Construction Materials Technologies (TST5878) LVTI-012-02-01 TAS 100(A) 1995 PRODUCT DESCRIPTION External Baffle Mounting flange TAMCO Off -Ridge Roof Minimum 26 ga. ASTM A792 AZ50 (non-HVHZ only) or ASTM A653 G90 steel off -ridge Vent with Baffle static roof ventilator with integrated baffle offset from the intake. Vent dimensions are 24" wide x 4-1/4" high and is available in nominal lengths of 4-ft, 6-ft, 8-ft and 10-ft. Material shall conform with FBC Section 1507.4.3 (non-HVHZ) and 1517.6 (HVHZ). LVT14001.3a This evaluation report is provided for State of Florida product approval under Rule 611320-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I CREEK L.V. Thompson, Inc. (TAMCO) TAMCO Off -Ridge Roof Vent with Baffle TECHNICAL SERVICES, LLC APPLICATION Deck Type: Minimum 15/32-inch APA span rated plywood sheathing for new and existing roof deck; Min. 19/32-inch APA span rated plywood sheathing in the HVHZ for new construction. (Deck shall be designed by others in accordance with FBC requirements) Roof slope: Minimum 4:12 Installation Height: Maximum 33-it Attachment Method: Cut-out a 3-inch opening sized according to manufacturer's instructions into the sheathing located a minimum 6-inch off the ridge. For a single vent, install the vent as close to the center of the roof length as possible. Multiple vents should be evenly spaced along the roof length. Remove interfering shingle nails around the perimeter of the opening and any debris prior to placing vent. Apply ASTM D 4586 or ASTM D 3409, Type I roofing cement/mastic to the underside of the vent flange at both the inside and outside perimeter and to continuously surround and seal the flange. Slide the top and side flanges of the vent underneath the shingles and allow the bottom flange to lie on top of the shingles. Attach the vent with galvanized or stainless steel roofing nails having minimum 12 ga. shank, minimum 3/.-inch diameter head and sufficient length to penetrate through the sheathing (ring shank nails shall be used in the HVHZ). Nails shall be located 1-inch from the edge of the flange and 8-inch o.c. along all four sides of the vent. All exposed fasteners shall be sealed with roofing cement/mastic. All loosened shingles shall be adhered down with roof cement/mastic. Typical 8' O.C. MAX 8" 8" 8" 8" 8" ±r± ±r± 8" O O Maids rd ORWdgeWdWilh Pt ineretlt Bellle O O O O O O O O O O O O Lis: 11 Ga, min. 1-14' Corrosion Resistant. Smooth Roofing Nails Spacing: 8" O.C. MAX and 1' From Outer Edge Flange Allowable Roof Coverings: Asphalt shingles LVT14001.3a FL16918-113 Page 2 of 3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. I CREEK L.V. Thompson, Inc. (TAMCO) TAMCO Off -Ridge Roof Vent with Baffle TECHNICAL SERVICES. LLC LIMITATIONS 1) Fire Classification is outside the scope of this evaluation. 2) The roof deck and deck attachment shall be designed by others in accordance with the FBC. 3) TAMCO vents shall be installed in strict compliance with this evaluation report and the manufacturer's published installation instructions. In the event of conflict, the more restrictive installation shall be enforced. 4) Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion prior to installation. 5) Installation of the roof assembly is outside the scope of this evaluation. 6) TAMCO vents are intended to provide passive ventilation for an enclosed attic in residential construction applications. 7) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest P.E. have demonstrated compliance with the Florida Building Code, 7th Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents submitted by the named manufacturer. No 74021 - 9 : STATE OF :.14J� -'i tCs O R N 11fill it It" CERTIFICATION OF INDEPENDENCE 2020.09.16 11:09:47 wwremna.r -04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No, ANE9641 CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or disMbuting products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT LVT14001.3a FL16918-R3 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.