HomeMy WebLinkAboutENERGY CALC 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 76/10/2021 7:33 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY JWN BUILDERS, LLC.WORSNOP RESIDENCE Street: City, State, Zip: JENSEN BEACH , FL , LOT 634 VENTURE OUT Permit Number: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (ft²) New (From Plans) Detached 1 No 1876 7. Windows a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : Sgl, U=0.65 429.61 ft² SHGC=0.25 N/A f t ² N/A f t ² 9. Floor Types a. Raised Floor b. Slab-On-Grade Edge Insulation c. N/A R=19.0 966.00 ft² R=0.0 910.00 ft² R=f t ² 10. Wall Types a. Concrete Block - Polystyrene Bead AggR=0.0 2062.70 ft² b. N/A R=f t ² c. N/A R=f t ² 11. Ceiling Types a. Roof Deck (Unvented)R=19.0 1876.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts a. Sup: Attic, Ret: Attic, AH: AHU CLST 13. Cooling systems 14. Heating systems 15. Hot water systems a. Electric Cap: 1 gallons b. Conservation features None d. N/A R=f t ² Area Weighted Average Overhang Depth:1.308 ft. Area Weighted Average SHGC:0.250 Description Area Insulation Area Insulation Area Insulation Area 16. Credits None 2 (429.6 sqft.) (2062.7 sqft.) (1876.0 sqft.) (1876.0 sqft.) Conditioned floor area below grade (ft²) 0 a. Central Unit a. Electric Strip Heat k B t u / h r 29.4 SEER:16.00 Efficiency k B t u / h r Efficiency 27.0 COP:1.00 f t ² R 6 140 Tankless EF: 0.990 8. Skylights c. U-Factor:(AVG) S H G C ( A V G ) : N/A N/A f t ² Area Glass/Floor Area: 0.229 Total Proposed Modified Loads: Total Baseline Loads: 64.40 66.95 PASS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. OWNER/AGENT: DATE: BUILDING OFFICIAL: DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method FORM R405-2020 6-10-2021 PROJECT Title: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY JWN BUILDERS, LLC. 1 WORSNOP RESIDENCE Family Type: New/Existing: Bedrooms: Conditioned Area: Total Stories: Worst Case: Rotate Angle:0 No 2 1876 2 New (From Plans) Detached Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: FL , JENSEN BEACH , St. Lucie LOT 634 VENTURE OU Street Address Comment: Building Type: User Cross Ventilation:No Whole House Fan:No TMY Site Design Temp Int Design Temp Heating Design Daily Temp Design Location 2.5 %97.5 %Degree Days Moisture RangeWinter Summer CLIMATE 90 70 75 299 62 Low39FL_VERO_BEACH_MUNIFL, Fort Pierce______ Number Name Area Volume BLOCKS 1 Entire House 1876 15008 Number Name Area Volume SPACES Kitchen Occupants Bedrooms Cooled HeatedInfil ID Finished 1 FOYER 116 928 No 0 Yes Yes1 Yes 2 POWDER RM 36 288 No 0 Yes Yes1 Yes 3 M TOILET 30 240 No 0 Yes Yes1 Yes 4 M BATH 76 608 No 0 Yes Yes1 Yes 5 MASTER BEDROO 186 1488 No 0 1 Yes Yes1 Yes 6 M WIC 27 216 No 0 Yes Yes1 Yes 7 W/D 14 108 No 0 Yes Yes1 No 8 KITCHEN/LIVING R 425 3400 Yes 0 Yes Yes1 Yes 9 WIC 20 160 No 0 Yes Yes1 Yes 10 STAIRS UP 52 416 No 0 Yes Yes1 Yes 11 BEDROOM 198 1584 No 0 1 Yes Yes1 Yes 12 SINKS 42 336 No 0 Yes Yes1 No 13 LINEN CLST 12 96 No 0 Yes Yes1 No 14 AHU CLST 25 200 No 0 Yes Yes1 No 15 TOILET 48 384 No 0 Yes Yes1 Yes 16 STORAGE WIC 42 336 No 0 Yes Yes1 Yes 17 SITTING RM 527 4216 No 0 Yes Yes1 Yes 6/10/2021 7:33 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Floor Type Area Tile Wood Carpet FLOORS Perimeter R-Value Joist R-ValueSpace Perimeter 1 116 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -14 ft FOYER 2 36 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -6 ft POWDER RM 3 30 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -14.6 ft M TOILET 4 76 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -11.5 ft M BATH 5 186 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -14.3 ft MASTER BEDRO 6 27 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -3.1 ft M WIC 7 14 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -1 ft W/D 8 425 ft² 1 0 0______ Slab-On-Grade Edge Insulatio - - - -63.1 ft KITCHEN/LIVING 9 20 ft² 1 0 0______19Raised Floor 19 - - - - - - - -WIC 10 52 ft² 1 0 0______19Raised Floor 19 - - - - - - - -STAIRS UP 11 198 ft² 1 0 0______19Raised Floor 19 - - - - - - - -BEDROOM 12 42 ft² 1 0 0______19Raised Floor 19 - - - - - - - -SINKS 13 12 ft² 1 0 0______19Raised Floor 19 - - - - - - - -LINEN CLST 14 25 ft² 1 0 0______19Raised Floor 19 - - - - - - - -AHU CLST 15 48 ft² 1 0 0______19Raised Floor 19 - - - - - - - -TOILET 16 42 ft² 1 0 0______19Raised Floor 19 - - - - - - - -STORAGE WIC 17 527 ft² 1 0 0______19Raised Floor 19 - - - - - - - -SITTING RM # Type Materials Color Absor. Roof Solar Deck Insul. Pitch ROOF Tested Roof Area Gable Area Emitt Tested EmittSA (deg) Rad Barr 1 Hip Metal 1977 ft² Light 0.1 19 18.43______No0 ft² 0.9 NoN ATTIC # Type Ventilation Area RBS IRCCVent Ratio (1 in) ______ 1 Full attic Unvented 1876 ft² N N0 6/10/2021 7:33 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # Ceiling Type R-Value Area Framing Frac Truss Type CEILING Space Ins Type 1 Under Attic (Unvented)0 116 ft² 0.1 Wood______FOYER Blown 2 Under Attic (Unvented)0 36 ft² 0.1 Wood______POWDER RM Blown 3 Under Attic (Unvented)0 30 ft² 0.1 Wood______M TOILET Blown 4 Under Attic (Unvented)0 76 ft² 0.1 Wood______M BATH Blown 5 Under Attic (Unvented)0 186 ft² 0.1 Wood______MASTER BEDRO Blown 6 Under Attic (Unvented)0 27 ft² 0.1 Wood______M WIC Blown 7 Under Attic (Unvented)0 14 ft² 0.1 Wood______W/D Blown 8 Under Attic (Unvented)0 425 ft² 0.1 Wood______KITCHEN/LIVING Blown 9 Under Attic (Unvented)0 20 ft² 0.1 Wood______WIC Blown 10 Under Attic (Unvented)0 52 ft² 0.1 Wood______STAIRS UP Blown 11 Under Attic (Unvented)0 198 ft² 0.1 Wood______BEDROOM Blown 12 Under Attic (Unvented)0 42 ft² 0.1 Wood______SINKS Blown 13 Under Attic (Unvented)0 12 ft² 0.1 Wood______LINEN CLST Blown 14 Under Attic (Unvented)0 25 ft² 0.1 Wood______AHU CLST Blown 15 Under Attic (Unvented)0 48 ft² 0.1 Wood______TOILET Blown 16 Under Attic (Unvented)0 42 ft² 0.1 Wood______STORAGE WIC Blown 17 Under Attic (Unvented)0 527 ft² 0.1 Wood______SITTING RM Blown WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 1 0 0FOYER00010 8S Concrete Block - Polystyren 0.10Exterior80.0 ft² ____ 2 0 0FOYER0004 8W Concrete Block - Polystyren 0.10Exterior32.0 ft² ____ 3 0 0POWDER R 0006 8W Concrete Block - Polystyren 0.10Exterior48.0 ft² ____ 4 0 0M TOILET 0014 8E Concrete Block - Polystyren 0.10Exterior32.7 ft² ____ 5 0 0M TOILET 0006 8S Concrete Block - Polystyren 0.10Exterior48.0 ft² ____ 6 0 0M TOILET 0064 8SW Concrete Block - Polystyren 0.10Exterior36.0 ft² ____ 7 0 0M BATH 0037 8E Concrete Block - Polystyren 0.10Exterior58.0 ft² ____ 8 0 0M BATH 0032 8SW Concrete Block - Polystyren 0.10Exterior18.0 ft² ____ 9 0 0M BATH 0002 8W Concrete Block - Polystyren 0.10Exterior16.0 ft² ____ 10 0 0MASTER BE 00414 8E Concrete Block - Polystyren 0.10Exterior114.7 ft² ____ 11 0 0M WIC 0023 8E Concrete Block - Polystyren 0.10Exterior25.3 ft² ____ 12 0 0KITCHEN/LIV 00531 8N Concrete Block - Polystyren 0.10Exterior251.3 ft² ____ 13 0 0KITCHEN/LIV 00917 8E Concrete Block - Polystyren 0.10Exterior142.0 ft² ____ 14 0 0KITCHEN/LIV 00014 8W Concrete Block - Polystyren 0.10Exterior112.0 ft² ____ 15 0 0WIC0004 8S Concrete Block - Polystyren 0.10Exterior32.0 ft² ____ 16 0 0WIC0005 8W Concrete Block - Polystyren 0.10Exterior40.0 ft² ____ 17 0 0STAIRS UP 00013 8W Concrete Block - Polystyren 0.10Exterior104.0 ft² ____ 18 0 0BEDROOM00412 8E Concrete Block - Polystyren 0.10Exterior98.7 ft² ____ 19 0 0BEDROOM00015 8S Concrete Block - Polystyren 0.10Exterior120.0 ft² ____ 20 0 0TOILET0046 8E Concrete Block - Polystyren 0.10Exterior50.7 ft² ____ 21 0 0STORAGE W 0037 8E Concrete Block - Polystyren 0.10Exterior58.0 ft² ____ 22 0 0SITTING RM 00531 8N Concrete Block - Polystyren 0.10Exterior251.3 ft² ____ 23 0 0SITTING RM 00917 8E Concrete Block - Polystyren 0.10Exterior142.0 ft² ____ 6/10/2021 7:33 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS #Wall Type R-Value Area Adjacent Framing Solar Ornt Fraction Absor. HeightWidth Ft In Ft InTo Cavity Sheathing R-ValueSpace Grade% Below 24 0 0SITTING RM 00019 8W Concrete Block - Polystyren 0.10Exterior152.0 ft² ____ # Ornt Panes NFRC U-Factor SHGC Area Depth Separation Int ShadeFrame Screening WINDOWS Overhang Orientation shown is the entered, Proposed orientation. Wall ID Imp 1 S Low-E Single 0.65 0.25 20.5 ft² 6 ft 0 in 1 ft 4 in NoneMetal None______Yes1 Y 2 W Low-E Single 0.65 0.25 6.0 ft² 6 ft 0 in 1 ft 4 in NoneMetal None______Yes2 Y 3 W Low-E Single 0.65 0.25 6.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes3 Y 4 E Low-E Single 0.65 0.25 4.0 ft² 1 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes4 Y 5 S Low-E Single 0.65 0.25 9.0 ft² 1 ft 0 in 1 ft 4 in Drapes/blindsMetal Exterior 5______Yes5 Y 6 E Low-E Single 0.65 0.25 4.6 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes7 Y 7 E Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes10 Y 8 N Low-E Single 0.65 0.25 75.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes12 Y 9 N Low-E Single 0.65 0.25 40.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes12 Y 10 E Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes13 Y 11 W Low-E Single 0.65 0.25 9.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes14 Y 12 W Low-E Single 0.65 0.25 6.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes17 Y 13 S Low-E Single 0.65 0.25 12.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes19 Y 14 S Low-E Single 0.65 0.25 35.6 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes19 Y 15 E Low-E Single 0.65 0.25 4.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes20 Y 16 N Low-E Single 0.65 0.25 75.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes22 Y 17 N Low-E Single 0.65 0.25 48.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes22 Y 18 E Low-E Single 0.65 0.25 15.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes23 Y 19 W Low-E Single 0.65 0.25 30.0 ft² 1 ft 0 in 1 ft 4 in NoneMetal None______Yes24 Y Method CFM 50 ACH 50ELASLAScope INFILTRATION ACHEqLA# 1250.3 568.6.000254Wholehouse .1191128.78Proposed ACH(50)1 HEATING SYSTEM # System Type Efficiency Capacity DuctsSubtypeBlockSpeed 1 Electric Strip Heat/COP:1 27 kBtu/hr ______sys#1None1 # System Type Efficiency Capacity Air Flow SHR COOLING SYSTEM DuctsSubtypeBlockSubtype 1 Central Unit/SEER: 16 29.4 kBtu/hr 882 cfm 0.8______sys#1Split1 Singl 6/10/2021 7:33 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT # System Type EF Cap Use SetPnt Conservation HOT WATER SYSTEM SubType Location 1 Electric 0.99 1 gal 55.1 gal 120 deg None______Tankless FOYER FSEC Company Name System Model #Collector Model # Collector SOLAR HOT WATER SYSTEM Storage FEFCert #Area Volume None None f t ² ______ # Location R-Value Area Location Area ---- Supply -------- Return ---- Leakage Type Handler CFM 25Air QN RLF DUCTS Heat Cool HVAC # TOT OUT CFM25 1 Attic 6 140 ft² Attic 14 ft² Prop. Leak Free AHU CLST 56.3 cfm 0.03 0.50______1 1 --- cfm TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling [ ] Jan [ ] Feb [ ] Mar [ ] Apr [ ] May [X] Jul [X] Aug [X] Sep [ ] Oct [ ] Nov [ ] Dec [ ] Dec [X] Dec[X] Nov [X] Nov [ ] Oct [X] Oct [ ] Sep [ ] Sep [ ] Aug [ ] Aug [ ] Jul [ ] Jul[ ] Jun [ ] Jun [X] Jun [ ] May [ ] May [ ] Apr [X] Apr [X] Mar [X] Mar [X] Feb [ ] Feb [X] Jan [ ] Jan Heating Venting Thermostat Schedule:HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Cooling (WEH)AM PM 78 80 78 80 78 80 78 80 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 Heating (WD)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH)AM PM 65 68 65 68 65 68 65 68 65 68 65 68 65 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.0 ft² 0 ft 0.3 FOYER Default(8 lbs/sq.ft.f t ² f t 0.3 POWDER RM Default(8 lbs/sq.ft.f t ² f t 0.3 M TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 M BATH Default(8 lbs/sq.ft.f t ² f t 0.3 MASTER BEDROO Default(8 lbs/sq.ft.f t ² f t 0.3 M WIC Default(8 lbs/sq.ft.f t ² f t 0.3 W/D Default(8 lbs/sq.ft.f t ² f t 0.3 KITCHEN/LIVING R Default(8 lbs/sq.ft.f t ² f t 0.3 WIC Default(8 lbs/sq.ft.f t ² f t 0.3 STAIRS UP Default(8 lbs/sq.ft.f t ² f t 0.3 BEDROOM Default(8 lbs/sq.ft.f t ² f t 0.3 SINKS Default(8 lbs/sq.ft.f t ² f t 0.3 LINEN CLST Default(8 lbs/sq.ft.f t ² f t 0.3 AHU CLST Default(8 lbs/sq.ft.f t ² f t 0.3 TOILET Default(8 lbs/sq.ft.f t ² f t 0.3 STORAGE WIC 6/10/2021 7:33 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft.f t ² f t 0.3 SITTING RM 6/10/2021 7:33 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 7 of 7 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT LOT 634 VENTURE OUT, JENSEN BEACH, FL, 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft²) New (From Plans) Detached 1 2 No 1876 7. Windows** a. U-Factor: S H G C : b. U-Factor: S H G C : c. U-Factor: S H G C : d. U-Factor: S H G C : Sgl, U=0.65 429.61 ft² SHGC=0.25 N/A f t ² N/A f t ² N/A f t ² 9. Floor Types a. Raised Floor b. Slab-On-Grade Edge Insulation c. N/A R=19.0 966.00 ft² R=0.0 910.00 ft² R= f t ² 10. Wall Type and Insulation a. Concrete Block - Polystyrene Bead AggreR=0.0 2062.70 ft² b. N/A R= f t ² c. N/A R= f t ² 11. Ceiling Type and insulation level a. Roof Deck (Unvented) R=19.0 1876.00 ft² f t ² R=b. N/A c. N/A R = f t ² 12. Ducts, location & insulation level 13. Cooling systems 14. Heating systems k B t u / h r 15. Hot water systems a. Electric Cap: 1 gallons EF: 0.99 b. Conservation features None d. N/A R= f t ² Description Area Insulation Area Insulation Area Insulation Area Credits (Performance method)None Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 1.308 ft. 0.250 a. Electric Strip Heat 27.0 COP:1.00 a. Central Unit 29.4 SEER:16.00 k B t u / h r Efficiency Efficiency a. Sup: Attic, Ret: Attic, AH: AHU CLST 6 140 R f t ² 8. Skylights a. U-Factor(AVG): S H G C ( A V G ) : Description Area N/A N/A f t ² I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature:Date: Address of New Home:City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. Page 1 of 1 FORM R405-2020 6/10/2021 7:33 AM Project Name: Owner: Builder Name: Permit Office: Jurisdiction: ST LUCIE COUNTY ST LUCIE COUNTY JWN BUILDERS, LLC.WORSNOP RESIDENCE Street: City, State, Zip: JENSEN BEACH , FL , LOT 634 VENTURE OUT Permit Number: Design Location: FL, Fort Pierce CHECKAIR BARRIER CRITERIA A continuous air barrier shall be installed in the building envelope. The exterior thermal envelope contains a continuous air barrier. Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. The junction of the top plate and the top of exterior walls shall be sealed. Knee walls shall be sealed. The space between window/door jambs and framing, and skylights and framing shall be sealed. Rim joists shall include the air barrier. The air barrier shall be installed at any exposed edge of insulation. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrow cavities Shafts, penetrations Crawl space walls Floors (including above-garage and cantilevered floors) Rim joists Windows, skylights Walls Ceiling/attic General COMPONENT Garage separation Recessed lighting Plumbing and wiring S h o w e r / t u b HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor, wall covering or ceiling The air barrier shall be installed behind electrical or communication boxes or air-sealed boxes shall be installed. The air barrier installed at exterior walls adjacent to showers and tubs shall separate them from the showers and tubs. Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Recessed light fixtures installed in the building thermal envelope shall be sealed to the finished surface. Air sealing shall be provided between the garage and conditioned spaces. When required to be sealed, concealed fire sprinklers shall only be sealed in a manner that is recommended by the manuf acturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. C o n c e a l e d Electrical/phone box on exterior walls Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA INSULATION INSTALLATION CRITERIA EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software6/10/2021 7:33 AM Page 1 of 1 Air-permeable insulation shall not be used as a sealing material. The insulation in any dropped ceiling/soffit shall be aligned with the air barrier. Cavities within corners and headers of frame walls shall be insulated by completely filling the cavity with a material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Rim joists shall be insulated. Floor framing cavity insulation shall be installed to maintain permanent contact with the underside of subfloor decking, or floor framing cavity insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. and doors on exterior wall requirements Recessed light fixtures installed in the building thermal envelope shall be air tight and IC rated. sprinklers Where provided instead of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exterior walls adjacent to showers and tubs shall be insulated. 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. a