HomeMy WebLinkAboutLAYOUTrevisions
MARK
i
i
i
TYPE
WINDOW SCHEDULE
SIZE D.P.
STYLE W H + -
o
ry
N
0
NOTES
001
SH23
SINGLE HUNG
3'-1"
3'-2 1/2"
48.09
52.16
002
T.G.
PICT OCTAGON
2'-0"
2'-0"
46.82
50.89
Opague
003
T.G.
PICTURE
3'-6"
1'-411
46.82
50.89
Opague
004
SH25
SINGLE HUNG
3'-1"
5'-3"
46.82
50.89
Egress
005
SH25
SINGLE HUNG
- 3'-111
5'-3"
46.82
50.89
006
SH25
SINGLE HUNG
3'-111
5'-3"
46.82
50.89
007
SH25
SINGLE HUNG
3'-111
5'-3"
46.82
50.89
008
SH25
SINGLE HUNG
3'-111
5'-3"
46.82
50.89
009
SH25
SINGLE HUNG
3'-1"
5'-3"
46.82
50.89
010
SH25
SINGLE HUNG
3'-1"
5'-3"
46.82
50.89
011
SH23
SINGLE HUNG
3'-1"
3'-2 1/2"
46.82
50.89
012
SH13
SINGLE HUNG
1'-7 1/2"
3'-2 1/2"
48.09
52.16
013
SHH33
SINGLE HUNG
2'-2 1/211
3'-2 1/2"
48.09
52.16
014
SH24
SINGLE HUNG
3'-1"
4'-2 1/2"
48.09
52.16
015
T.G.
PICTURE
3'-0"
1'-4"
48.09
52.16
016
SH25
SINGLE HUNG
3'-1"
5'-3"
48.09
52.16
017
SH25
SINGLE HUNG
3'-1"
5'-3"
48.09
52.16
018
SH25'
SINGLE HUNG
3'-1"
5'-3"
48.09
52.16
019
SH25;
SINGLE HUNG
3'-111
5'-3"
48.09
52.16
020
T.G.
PICTURE
6'-211
5'-3"
48.09
52.16
021
SH26i
SINGLE HUNG
3'-111
5'-311
48.09
52.16
022
SH25!
SINGLE HUNG
3'-1"
5'-3"
48.09
52.16.
023
SH25!
SINGLE HUNG
3'-1"
5'-3"
48.09
52.16
024 SH25 SINGLE HUNG
025 SHH33 SINGLE HUNG
NOTE TO G.G.
G.G. SHALL A55UME RE5PON51BILTY FOR ALL
MASONRY/ROUGH OPENING 51ZE5 AND 5HALL VERIFY
WITH PRODUCT 5PE029 BEFORE GONSTRUGTION.
3'-111 5'-311 48.09 52.16
2'-2 1/2" 3'-2 1/2" 48.09 52.16
NOTE:
ALL HINDOHS 4 DOOR GLAZING TO BE
IMPACT RE51STANT t LOW-E INSULATED.
6'-q 11211
(-AGGU 01 HUNG F
I WALL. ® 20. FL
50'-1° 6'-5 1
1
(Ci�g
20
i LOX6 153G n
153 Crwi >;
SITTING RM !
1 _ 8'-O" GLG.
m
"
N
l� 1 O;
,
T_ T-2'I i 51_011 i 4�_811 I b'-31/2"
018 019
BAR SINK _
"
5H
8'-O" GLG.
4' I"
DN I® 017
IR 15
G NTLS
5 _ 0 015 021 GU ED T.
G.T. HH R I
O
-, BATH
�O 8'-0" GLG.
15
p 13
G
014 BENCH
5'-6' b'-8" 5' 5 I/2 2'-10"
l2x �x
B
N -0" GL6. O d
O d'
IR 15
14'-II"
I�
G 5 012 011
14
1�QC C 1r�/� RAI 6
X CONY
(it -loll 5141
Ia -1I i�2°
-
2ND FLOOR PLAN
DOOR SCHEDULE
MARK
STYLE
DOOR
_D.P.
NOTES
WD
HGT
+
-
001
SINGLE EXTERIOR
3'-0"
6'-8"
45.92
49.99
MAIN EGRESS DO NOT SHUTTER
002
SLIDING DOUBLE EXTERIOR
6'-0"
6'-8"
003
SINGLE
2'-811
6'-811
004
POCKET
2'-811
6'-811
005
SINGLE
1'-811
6'-8"
006
POCKET
2'-811
6'-811
007
SINGLE
2'-0"
6'-811
008
POCKET
2'-811
6'-811
009
BIFOLD DOUBLE
2'-811
6'-811
010
POCKET
2'-61
6'-811
011
DOUBLE EXTERIOR
5'-4"
6'-8"
44.65
57.52
FR DR
012
POCKET
2'-011
6'-811
013
SINGLE
2'-811
6'-811
014
POCKET
2'-811
6'-811
015
POCKET
2'-6"
6'-8"
016
POCKET
2'-811
6'-811
017
SINGLE
2'-811
6-811
018
BIFOLD DOUBLE
4'-011
6'-811
019
BIFOLD DOUBLE
4'-011
6'-811
020
SHOWER
2'-011
6'-811
T.G.
021
SLIDING DOUBLE SHOWER
4'-01'
1 6'-8"
T.G.
WIND
PRESSURES
NOT DONE
1 ST FLOOR PLAN
CALCULATIONS
AIR CONDITIONED AREAS
SECOND FLOOR 910 SF
GROUND FLOOR 966 SF
(N.I.G. STAIR OPENING) 1876 SF
(+45.0 S.F. STAIR OPENING)
NON CONDITIONED AREAS
PORCH 45 SF
45 SF
GROSS AREA
GROSS AREA 1921 SF
no. date
designed PAR
drawn PAR
checked 55
date 3/I/21
scale I/4" = P-O" U.N.O.
job no. 21-0013 . WOR
E- A
QUANTUM ENGINEERING ASSOCIATES INC.
m
StructuralEngineering & Cost Segregation
6415 LAKE WORTH ROAD
SUITE 105
GREENACRES, FLORIDA 33463
W W W.QEASSOCIATFS.COM
_J
v
,J
z
u
W
U
Ln
R'
U
W
-�
�s
z
z�
U
LL
W
�"
oy
z�
W v
o�
sheet
A®1