ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Low Slope Application
Prescriptive BUR-RAS 150
Asphaltic Shingles
Concrete or Clay Tile
Metal Roofs
Wood Shingles and
Shakes
Other
Required Sections of
the Permit Application
Form
A, B, C
A, B, C
A, B, ❑
A,B,❑,F
A, B, ❑
A, B, ❑
As Applicable
Attachments Required
See List Below
ATTACHMENTS REOUIRFr] Ac Annfirnhim)-
193i4,6.6.7
2,4,5,6,7
12,4,5,6,7
1,2,3,4,5,6,7
1,2.3,4,5,6,7
1,2,4,5,6,7
1,2,3,4,5,8,7
Z.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7,
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCIEVORKS
Section C (Low Slope Roof)
Fill In specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer: POLYGLASS
Product Approval No.: FL#1654.1
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': _ Zone 1: Zone 2: _Zone 3:
Max. Design Pressure, from the specific product approval
system: W-82 -90
Deck:
Type. PLYWOOD
Gauge Thickness: 518"
Slope: 0112
Anchor/Base Sheet & No. of Ply(s): 1
Anchor/Base Sheet Fastener/Bonding Material:
SCREWS AND PLATES
Insulation Base Layer: N/A
Base Insultation Size and Thickness: TAPERED 1/8"
Base Insulation Fastener/Bonding Material:
SCREWS AND PLATES
Top Insulation Layer: N/A
Top Insulation Size and Thickness: N/A
Top Insulation Fastener/Bonding Material
SCREWS AND PLATES
Base Sheet(s) & No. of Phyla): 1 PLY
Base Sheet Fastener/Bonding Material:
SCREWS AND PLATES
Ply Sheet(s)' & No. of Ply(s): i
Ply Sheet Fastener/Bonding Material:
APPTORCH
Top Ply: 1 APP TORCH
Top Ply Fastener/Bonding Material:
APPTORCH
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':." oc @ Lap, # Rows_ ® _° oc
Zone 1:." oc @ Lap, # Rows _ ® _" x
Zone 2:_" oc @ Lap, If Rows — ® _" co
Zone 3:." pc @ Lap, # Rows— ® _' oc
Number of Fasteners Per Insulation Board:
Zone 1':—Zone 1:—Zone 2:_Zone 3:_
Illustrate Components Noted and Details as Applicable:
Woodbiocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc.,
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: JA TAYLOR ROOFING 5V CRIMO
Notice of Acceptance Number: FL#17443.1
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1: bone 2e: -67 Zone 2n:--7A—Zone 2r:-67 Zone 3e7i�one 3r-74
Deck Type: PLYWOOD'
Type Dnderlayment PEELSSTICK-OWENSCORNING POLYGLASS Mrs FLB5259.1
Roof Slope:
6 : 12
Insulation:
Fire Barrier:
RidgeVeM4afion9 Fastener Type&'Spacing: 6"FIELD /4' PERIMETER, an RING SHANK NAILS
Adhesive Type: �—
Type Cap Sheet
Mean Roof Height: 13 FF Roof Covering: METAL
Type & Size Drip 2„ „
Edam
ST. LUCIE ' ' _ORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for Mr with the values from Mr. If the Mrvalues
are greater than or equal to the M,values, for each area of the of, then the tile attachment method is acceptable.
Method 1'Moment Based Til Calculations Per RAS 12T
(Zone 1: _x2,_= �)_Mill:__ Product Approval M.
l
(Zone 2e: _x�= I -Mg_= Product Approval Mr
(Zone 2n: _x)L,=_j- Mg.
_miti._ Product Approval Mf
(Zone 2r: _x 1_= _�-Mg_= y_ Product Approval Mr
(Zone 3e: -x1._= _I-MW, _= Product Approval Mr
(Zone 3r: _X X_= _I-Mgt_=''aa Product Approval Mr
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (M,) From Table Below Product Approval M
�
r required Moment Resistance-
15'
20•
25'
30'
40'
34.4
36.5
38.2
39.7
42.2
M7,,224M4r
2.2
34.4
36.0
37.4
39.8
0.4
32.2
33.8
35.1
37.3
8.4
30.1
31.6
32.8
34.9
6.4
28.0
29.4
30.5
32.4
4.4
25.9
27.1
28.2
30.0
�•U u uacu M w IjUnUimi with a nsgaT moment Wsee the systems
• For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the "values are greater than or
equal to the F, values, for each area of the roof, then the tile attachment method is acceptable.
Method 3 "Uplift Based Tile Calculations Per RAS 12T
(Zone 1: _x L= x W:=) -W:_ cos r_=Fit_ Product Approval F'
_
(Zone 2e:x LxW:=,-W cos Prod Prod uct Approval F'
(Zone 2n:_x LxW:=_)-W;_cos r_=Fran Product Approval F'
(Zone 2r. _x L= x W:=-W: cos r= Fz, Product Approval F'
(Zone 3e: _x L_=x W:= ) _W:_ cos r= F,3 Product Approval F'
(Zone 3r: xll W: =_-W;_cos r=F,a•_ Product Approval F'
Where to Obtain Information
Description
Symbol
Where to find
Desi nPressure
g
Zones 1, 2e, 2n, 2n 3e, 3r
From
Prepared
applicable tablam RAS 127 or byan engineermganalysis
by PE based on ASCE ]
Mean Roof Height
H
Job
She
Roof Slope
B
lab
Site
Aerodynamic Multiplier
a
Pro
Juct Approval
Restodng Moment due to Gravity
Ma
Pro
uct Approval
Attachment Resistance
Mf
Product
Approval
Required Moment Resistance
Ma
Calculated
Minimum Attachment Resistance
F'
Product
Approval
Required Uplift Resistance
F,
Cal
Mated
Average Tile Weight
W
Pr
utt Approval
The Dimensions
L=length W=width
I Pro
uct Approval
All calculations must be submitted to the building official at the time of petitapplication.