Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Alexandra Laboy-9.45kw
SCOPE OF WORK: TO INSTALL A ROOF MOUNTED SOLAR PHOTOVOLTAIC SYSTEM AT THE OWNER RESIDENCE LOCATED AT 4801 SILVER OAK DR FORT PIERCE, FL 34982. THE POWER GENERATED BY THE PV SYSTEM WILL BE INTERCONNECTED WITH THE UTILITY GRID THROUGH THE EXISTING ELECTRICAL SERVICE EQUIPMENT. THE PV SYSTEM DOES NOT INCLUDE STORAGE BATTERIES EQUIPMENT SUMMARY 30 HYUNDAI HID-S315RG(BK) MODULES 30 ENPHASE IQ7-60-2-US MICROINVERTERS GENERAL NOTES: GOVERNING CODES I 2015 NFPA 1 (FIRE CODE) 2017 NATIONAL ELECTRICAL CODE 2020 FLORIDA BUILDING CODE (7TH EDITION) AUTHORITY HAVING JURISDICTION (AHJ): SAINT LUCIE COUNTY • THESE CONSTRUCTION DOCUMENTS HAVE BEEN BASED ON FIELD INSPECTIONS AND OTHER INFORMATION AVAILABLE AT THE TIME. ACTUAL FIELD CONDITIONS MAY REQUIRE MODIFICATIONS IN CONSTRUCTION DETAILS. • ARCHITECT HAS NOT BEEN RETAINED TO SUPERVISE ANY CONSTRUCTION OR INSTALLATION OF ANY EQUIPMENT AT SITE. • CONTRACTOR SHALL FURNISH ALL LABOR, MATERIAL, EQUIPMENT, TOOLS, OBTAINS ALL PERMITS, LICENSES AND PAY ALL REQUIRED FEES AND COMPLETE INSTALLATION. • CONTRACTOR HAS THE FULL RESPONSIBILITY TO CHECK AND VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. ANY DISCREPANCIES SHALL BE REPORTED TO THE ENGINEER BEFORE PROCEEDING WITH THE WORK. ANY WORK STARTED BEFORE CONSULTATION AND ACCEPTANCE BY THE ENGINEER SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE SUBJECT TO CORRECTION BY THEM WITHOUT ADDITIONAL COMPENSATION. • DAMAGE CAUSED TO THE EXISTING STRUCTURE, PIPES, DUCTS, WINDOWS, WALL, FLOORS, ETC. SHALL BE REPAIRED TO THE ORIGINAL CONDITION OR REPLACED BY THE CONTRACTOR AT NO ADDITIONAL COST. • THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THE PROPER INSTALLATION AND COMPLETION OF THE WORK WITH APPROVED MATERIALS. • NO CHANGES ARE TO BE MADE WITHOUT THE CONSULTATION AND APPROVAL OF THE ARCHITECT. • CONTRACTOR SHALL OBTAIN BUILDING PERMIT. NO WORK TO START UNLESS BUILDING PERMIT IS PROPERLY DISPLAYED. • ALL WORKMANSHIP AND MATERIALS SHALL BE OF FIRST QUALITY AND IN COMPLIANCE WITH THE REQUIREMENTS OF THE FL BUILDING CODE, THE DEPARTMENT OF ENVIRONMENTAL PROTECTION AND ALL PERTINENT AGENCIES. • IT IS ESSENTIAL THAT ALL WORK PROCEED WITH THE MAXIMUM COOPERATION OF ALL PARTIES AND WITH MINIMUM INTERFERENCE TO THE OCCUPANTS WITHIN THE BUILDING. THE OWNER'S DIRECTIONS IN THIS REGARD SHALL BE FULLY COMPLIED WITH. • ALL EXPOSED PLUMBING, HVAC, ELECTRICAL DUCTWORK, PIPING AND CONDUITS ARE TO BE PAINTED BY GENERAL CONTRACTOR. • THE CONTRACTOR SHALL PERFORM THE WORK IN STRICT CONFORMANCE WITH THE LOCAL LAWS, REGULATIONS AND THE NATIONAL ELECTRIC CODE. • THE CONTRACTOR SHALL OBTAIN ALL PERMITS, APPROVALS, AFFIDAVITS, CERTIFICATIONS, ETC. AND PAY ALL FEES AS REQUIRED BY THE LOCAL AUTHORITIES. • CONTRACTORS SHALL OBTAIN FIRE CERTIF. UPON COMPLETION OF WORK. ELECTRICAL NOTES: WIRING AND CONDUIT NOTES: • ALL CONDUIT SIZES AND TYPES, SHALL BE LISTED FOR ITS PURPOSE AND APPROVED FOR THE SITE APPLICATIONS • ALL PV CABLES AND HOMERUN WIRES BE #10AWG'USE-2, PV WIRE, OR PROPRIETARY SOLAR CABLING SPECIFIED BY Ml OR EQUIVALENT; ROUTED TO SOURCE CIRCUIT COMBINER BOXES AS REQUIRED • ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO [NEC 690.8 (A)(1) & (13)(1)], [NEC 240] [NEC 690.71 FOR MULTIPLE CONDUCTORS • ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE DERATED ACCORDING TO [NEC TABLE 310.15 (B)(2)(C)] BLACK Ol • EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2, 90°C RATED, WET AND UV RESISTANT, AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE USED TO PROTECT WIRE FROM SHARP EDGES • 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS • ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION • VOLTAGE DROP LIMITED TO 2% • NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS FOLLOWS: DC POSITIVE - RED (OR MARKED RED), DC NEGATIVE - GREY (OR MARKED GREY) • POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: DC POSITIVE - GREY (OR MARKED GREY), DC NEGATIVE - BLACK (OR MARKED BLACK) • AC CONDUCTORS >4AWG COLOR CODED OR MARKED: PHASE A OR L1- BLACK, PHASE B OR L2- RED, PHASE C OR L3- BLUE, NEUTRAL- WHITE/GRAY • THE EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE INSTALLED ONLY BY QUALIFIED PEOPLE. A QUALIFIED PERSON IS ONE WHO HAS SKILLS AND KNOWLEDGE RELATED TO THE CONSTRUCTION AND OPERATION OF THE ELECTRICAL EQUIPMENT AND INSTALLATIONS AND HAS RECEIVED SAFETY TRAINING TO RECOGNIZE AND AVOID THE HAZARDS INVOLVED. (NEC 690.4(C), NEC 2017) • LOCAL UTILITY PROVIDER SHALL BE NOTIFIED PRIOR TO USE AND ACTIVATION OF ANY SOLAR PHOTOVOLTAIC INSTALLATION. FOR A LINE SIDE TAP CONNECTION, UTILITY NEEDS TO BE NOTIFIED WELL IN ADVANCE TO COORDINATE BUILDING ELECTRICAL SHUT OFF. • NEW CONDUIT ROUTING SHOWN IS ESSENTIALLY SCHEMATIC. SUBCONTRACTOR SHALL LAY OUT RUNS TO SUIT FIELD CONDITIONS AND THE COORDINATION REQUIREMENTS OF OTHER TRADES. • ARRAY WIRING SHOULD NOT BE READILY ACCESSIBLE EXCEPT TO QUALIFIED PERSONNEL. • ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE WATERTIGHT AND APPROVED FOR USE IN WET LOCATIONS. (NEC 690), NEC 2017. • WIRING METHODS FOR PV SYSTEM CONDUCTORS Al PERMITTED WITHIN 10 IN. OF THE ROOF DECKING OR SHEATHING EXCEPT WHERE LOCATED DIRECTLY BELOW THE ROOF SURFACE THAT'S COVERED BY PV MODULES AND ASSOCIATED EQUIPMENT WIRING • BACK -FED BREAKER MUST BE AT THE OPPOSITE END OF BUS BAR FROM THE MAIN BREAKER OR MAIN LUG SUPPLYING CURRENT FROM THE UTILITIES. • ALL CONDUCTORS AND WIRE TIES EXPOSED TO SUNLIGHT ARE LISTED AS UV RESISTANT. • CONTRACTOR SHALL FOLLOW ALL ELECTRICAL EQUIPMENT LABELING REQUIREMENTS IN NEC 690 • PV SOURCE, OUTPUT AND INVERTER CIRCUITS SHALL BE IDENTIFIED AT ALL POINTS OF TERMINATION, CONNECTION, AND SPLICES. THE MEANS OF ID CAN BE SEPARATE COLOR CODING, MARKING TAPE, TAGGING ETC. (NEC 690.4), NEC 2017. • MEASURE THE LINE -TO -LINE AND LINE -TO -NEUTRAL VOLTAGE OF ALL SERVICE ENTRANCE CONDUCTORS PRIOR TO INSTALLING ANY SOLAR EQUIPMENT. THE VOLTAGES FOR THE 240VAC RATED. SYSTEM RATING 9.45 KWDC 7.20 KWAC SHEETINDEX PV 0 COVER PAGE PV 1 STRING LAYOUT & BOM PV-2 ELECTRICAL LINE DIAGRAM & CALCS. PV 3 SPECIFICATIONS & SIGNAGE PV 4+ EQUIPMENT SPECIFICATIONS Pv_0 HOUSE PHOTO SCALE: NTS Printed copies of this document are not considered signed and seal, and all SHA-1 authentication code must be verified on any electronic copies "` It `T ++r''F �+ r {. ti � �►� = W. _ f�rflFRilYlyS Omar R Tirado 2021.07.15 13:02:54 -041001 , ATLANTIC KEY ENERGY LLC 7006 STAPOINT CT STE B WINTER PARK, FL 32792 +1 (407) 988-0273 REVISIONS DESCRIPTION DATE REV Signature with Seal DATE: 07/15/2021 PROJECT NAME & ADDRESS E O U O C ca 6, O� E m +� O Q LJJ Y o 0 O Q z W CD i Lb N Q W ll W X l *k N W coo _ 0 J O U Q LL E W SHEET NAME COVER PAGE SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-0 BILL OF MATERIALS EQUIPMENT QTY DESCRIPTION SOLAR PV MODULE 30 HYUNDAI HID-S315RG(BK) INVERTER 30 ENPHASE IQ7-60-2-US JUNCTION BOX 1 JUNCTION BOX, NEMA 3R, UL LISTED COMBINER BOX 1 ENPHASE IQ COMBINER 3 W/ IQ ENVOY (X-IQ-AM1-240-3) AC DISCONNECT 1 60A NON FUSED AC DISCONNECT, 240V, NEMA 3R, UL LISTED ENPHASE Q CABLE 35 ENPHASE Q CABLE 240V (PER CONNECTOR) BRANCH TERMINATOR 2 BRANCH TERMINATOR IQ WATER TIGHT CAP 5 IQ WATER TIGHT CAPS GROUNDING LUG 5 GROUNDING LUG LEGEND JB - JUNCTION BOX ca COMBINER BOX nco -AC DISCONNECT nnsa - MAIN SERVICE PANEL uM UTILITY METER ATLANTIC KEY ENERGY LLC 7006 STAPOINT CT -------- -CONDUIT STE B WINTER PARK, FL 32792 +1 (407) 988-0273 36" RE ETBACK REVISIONS DESCRIPTION DATE REV Y U OA OB - MODULE STRINGING w w � Signature with Seal LL B-3 CD M B-4 (N) JUNCTION BOX (N) 3/4" LTNM CONDUIT Y (N) ENPHASE IQ COMBINER 3 B-5 Q (N) AC DISCONNECT DATE: 07/15/2021 m (E) MAIN SERVICE PANEL B-2 H W PROJECT NAME & ADDRESS Printed copies of this document are not considered signed LU B-6 U) (E) UTILITY METER and seal, and all SHA-1 authentication code must be verified B-1 W on any electronic copies B-7 LL 4,,,+�xf Omar R T �_ W _ F i -t = 2021.07.1 — B-9 A-2 A-1 — � m o E 0 -t R t 5 13:03:06arAire B-10 A-3 J z LU 0 c O LL w U o M R 4 B-11 A-4 � p > 01 Lo X U Y z j Z (n J w °`° Q Q 0- Q W cn a >, B-12 A-5 A-14 X jr,* N W 00 C) M W W LL_ J O " B-13 A-6 A-13 W LU Q M 0 E B-14 A-7 A-)12 co �L w co B-15 A-8 A-11 B-16 A-9 A-10 SHEET NAME STRING LAYOUT & BOM V//////'�3/6�'//F/l/R/E//S/E//T/B/ACK SHEET SIZE ANSI B 11" X 17" 1 ROOF PLAN WITH STRING LAYOUT & BOM SHEET NUMBER PV-1 SCALE: 1/8" = 1'-0" PV-1 INITIAL CONDUCTOR FINAL CONDUCTOR # OF CURRENT -CARRYING CONDUIT FILL CONT. MAX. BASE DEBATED TERMINAL VOLTAGE ID TYPICAL LOCATION LOCATION CONDUCTOR CONDUIT PARALLEL CONDUCTORS IN OCPD EGC TEMP. CORR. FACTOR FACTOR CURRENT CURRENT AMP. AMP. AMP. LENGTH DROP CIRCUITS CONDUIT RATING 1 1 BRANCH 1 JUNCTION BOX 12 AWG Q CABLE 1 2 N/A 6 AWG BARE 0.76 (55°C) N/A 14.OA 17.5A N/A N/A 25A 50FT 0.74% COPPER 2 1 BRANCH 2 JUNCTION BOX 12 AWG Q CABLE 1 2 N/A 6 AWG BARE 0.76 (55°C) N/A 16.OA 20.OA N/A N/A 25A 67FT 0.96% ATLANTIC KEY ENERGY LLC COPPER 7006 STAPOINT CT 3 1 JUNCTION BOX IQ COMBINER BOX 10 AWG THWN-2 COPPER MIN 0.75" DIA LTNM 2 4 20A 10 AWG THWN-2, COPPER 0.76 (55°C) 0.8 16.OA 20.OA 40A 24.3A 35A 55FT 0.95% STE B WINTER PARK, FL 32792 THWN-2, +1 (407) 988-0273 4 1 IQ COMBINER BOX AC DISCONNECT 8 AWG THWN-2 COPPER MIN 0.75" DIA LTNM 1 3 N/A 10 AWG COPPER 0.96 (33°C) 1 30.OA 37.5A 55A 52.8A 50A 5FT 0.04% 5 1 AC DISCONNECT MSP 8 AWG THWN-2 COPPER MIN 0.75" DIA LTNM 1 3 40A 10 AWG THWN-2, COPPER 0.96 (33°C) 1 30.OA 37.5A 55A 52.8A 50A 5FT 0.04% REVISIONS [NOTE]: LTNM OR EQUIVALENT TYPE CONDUIT DESCRIPTION DATE REV Signature with Seal TO UTILITY GRID BRANCH 1 u 2 N BI-DIRECTIONAL UTILITY 14- HYUNDAI HID-S315RG(BK) MODULES O METER#ACD4563 1-PH, 3-W, 120V/240V BACK FEED BREAKER AT u 2 N THE OPPOSITE END OF DATE: 07/15/2021 • . • THE MAIN BREAKER E (E) MAIN BREAKER TO PROJECT NAME & ADDRESS HOUSE 240 V, 20OA/2P Q CABLE JUNCTION BOX Ll L1 (E) MAIN SERVICE L2 N AC DISCONNECT: Lz PANEL, 200A RATED, '� '� '� 1 2 600 V, NEMA 3R, 3 240V60AMP , 1-PH, 3-W, 240V UL LISTED ENVOY NON -FUSED u Li I 10A/15A/2 NEMA 3R, UL LISTETD Lz L2 O Li 20A/2P U L2 L1 L1 L1 Lz40A/2P L1 L2 CV - BRANCH 2 L 20A/2P 15A/2P N N m 16- HYUNDAI HID-S315RG(BK) MODULES L1 L2 --- - G— G J 0 U Q o I-`` -- — — — — — — G--- G N 4 5 c z o M y L May-W W LU U z (/) J LLI 000 a)Q W Co � >, (N) ENPHASE IQ (PP6) X it o ~ N COMBINER 3 EXISTING GROUND 00 ELECTRODE CONDUCTOR J U (X-IQ-AM1-240-3) POWER PERFECT BOX Q ILL A ^ {ES1PN), 120/24OV, NEMA 3X E J LU Printed copies of this document are not considered signed (30) ENPHASE IQ7-60-2-US MICROINVERTERS and seal, and all SHA-1 authentication code must be verified on any electronic copies � Ti f err. '''""'""" Omar R SHEET NAME ELECTRICAL LINE *.,`,�:.•+,a*►+'•y p.: = Ti ra do & CALLS. SERVICE INFO SHEET SIZE 2021.07.15 UTILITY PROVIDER: FP&L .�'. STAN .�► ? •�: :03:16 MAIN SERVICE VOLTAGE: 240V ANSI B w4a*i,♦• MAIN PANEL BRAND: SQUARE D 11° X 17" ''• � A ti � _0/I'00' `t MAIN SERVICE PANEL: 200A 1 ELECTRICAL LINE DIAGRAM il, Ill +soil MAIN CIRCUIT BREAKER RATING: 200A SHEET NUMBER MAIN SERVICE LOCATION: NORTH p\ �_2 PV-2 SCALE: NTS SERVICE FEED SOURCE: UNDERGROUND r V ❑2 F3] ELECTRIC SHOCK HAZARD TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABEL LOCATION: COMBINER BOX/ EMT ENCLOSURES/ AC DISCONNECT/ MAIN SERVICE PANEL (PER CODE: NEC 2017, 690.13(B)) ! WARNING! INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. POINT -OF -INTERCONNECTION OR AT MAIN SERVICE DISCONNECT (MSP) PER CODE: NEC 705.12(13)(2)(3)(b) LABEL LOCATION: CONDUIT, RACEWAY, ENCLOSURES, COMBINER BOX & AC DISCONNECT (PER CODE: NEC2017, 690.31(G)(3)(4) DISCONNECTF4] PHOTOVOLTAIC AC LABEL LOCATION: AC DISCONNECT/ BREAKER/ POINTS OF CONNECTION (PER CODE: NEC2017, 690.13(B) • 30A (PER CODE: NEC2017, 690.53) RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM t LABEL LOCATION: RAPID SHUTDOWN (AC DISCONNECT) PER CODE: NEC 690.58 (C)(3) ADHESIVE FASTENED SIGNS: • ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDES GUIDELINES FOR SUITABLE FONT SIZES, WORDS, COLORS, SYMBOLS, AND LOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1) • THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED. NEC 110.21(13)(3) • ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. F7] WARNING: DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: POINT OF INTERCONNECTION (PER CODE: NEC 2017, 705.12(B) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO soLga eLecrRic SHUT DOWN PV SYSTEM PV PgNELS AND REDUCE SHOCK HAZARD IN THE ARRAY LABEL LOCATION: RAPID SHUTDOWN (AC DISCONNECT) PER CODE: NEC 690.56 (C)(1) SOLAR MODULE SPECIFICATIONS MANUFACTURER / MODEL I HYUNDAI HID-S315RG(BK) VMP 33.4 V IMP 9.51 A VOC 40.5 V ISC 9.99 A TEMP. COEFF. VOC -0.31 %/K PTC RATING 273.0 W MODULE DIMENSION 66.18" (L) x 39.65" (W) PANEL WATTAGE 315W INVERTER SPECIFICATIONS MANUFACTURER / MODEL ENPHASE IQ7-60-2-US MAX DC SHORT CIRCUIT CURRENT 15 A CONTINUOUS OUTPUT CURRENT 1.OA (240V) AMBIENT TEMPERATURE SPECS RECORD LOW TEMP 0°C AMBIENT TEMP (HIGH TEMP 2%) 330C CONDUIT HEIGHT 0.5" ROOF TOP TEMP 900C CONDUCTOR TEMPERATURE RATE 550C MODULE TEMPERATURE COEFFICIENT OF VOC -0.31 %/K PERCENT OF VALUES NUMBER OF CURRENT CARRYING CONDUCTORS IN EMT 0.80 4-6 0.70 7-9 0.50 10-20 Printed copies of this document are not considered signed and sea€, and all SHA-1 authentication code must be verified on any electronic copies ATLANTIC KEY ENERGY LLC 7006 STAPOINT CT STE B WINTER PARK, FL 32792 +1 (407) 988-0273 REVISIONS DESCRIPTION I DATE I REV Signature with Seal DATE: 07/15/2021 0 N U O 00 E < Co O O U¢Li M� az° cCL i of OV) X Z (n J LLI CO m Q LLI U) � X O� ,— � N Co W J a0o O _ U Q LL. co W ,`Tt�,.f,,ff Omar R h.'• Tirado *y = • = 9 SHEET NAME - 2021.07.15 SPECIFICATIONS SI.,ROF 13:03:26 & SIGNAGE `� '• t a A o Ct • SHEET SIZE A16' L//�y ANSI B 11" X 17" SHEET NUMBER PV-3 HYUNDAI SOLAR MODULE RGMono -Crystalline Type HiD-S310RG(BK) HiD-S3151313(131K) HiD-S3201313(13K) BLACK D N� PERC Technology Anti -LID / PID PERC technology provides ultra -high efficiency with better performance in low irradiation. Maximizes installation capacity in limited space. t0 Reliable Warranty HYUNDAI Global brand with powerful financial strength provide reliable 25-year warranty. Hyundai's Warranty Provisions Z2 • 12-Year Product Warranty v6Aas • On materials and workmanship 25 ' 25-Year Performance Warranty v6nas Initial year: 97% Linear warranty after second year: with 0.7%p annual degradation, 80% is guaranteed up to 25 years Certification l I. M0 www. hyu n d a i-e s. co. kr Both LID(Light Induced Degradation) and PID(Potential Induced Degradation) are strictly eliminated to ensure higher actual yield during lifetime. PCorrosion Resistant Various tests under harsh environmental conditions such as ammonia and salt -mist passed. About Hyundai Energy Solutions ,nclai Cei • • 1 I Q ass J� s"Mbled n 1 t t t Mechanical Strength Tempered glass and reinforced frame design withstand rigorous weather conditions such as heavy snow and strong wind. QQ UL / VDE Test Labs Hyundai's R&D center is an accredited test laboratory of both UL and VDE. Established in 1972, Hyundai Heavy Industries Group is one of the most trusted names in the heavy industries sector and is a Fortune 500 company. As a global leader and innovator, Hyundai Heavy Industries is committed to building a future growth engine by developing and investing heavily in the field of renewable energy. As a core energy business entity of HHI, Hyundai Energy Solutions has strong pride in providing high -quality PV products to more than 3,000 customers worldwide. UL 1703-3rd Edition - Flat -Plate Photovoltaic Modules and Panels r HYUNDAI ENERGY SOLUTIONS Electrical Characteristics Mechanical Characteristics Mono -Crystalline Module [HiD-S_RG(BK)) ATLANTIC KEY ENERGY LLC 7006 STAPOINT CT r 320 STE B WINTER 310 315 320 PARK, FL 32792 40.3 40.5 40.6 +1 (407) 988-0273 9.94 9.99 10.04 REVISIONS 33.1 33.4 33.7 9.45 9.51 9.57 DESCRIPTION DATE REV 6.25", mono -crystalline silicon 1,000 -0.391 -0.31 Signature with Seal 0.031 *All data at STC (standard rest conditions). Above data maybe changed without prior notice. 1,007 mm(39") x 1,681 mm(66") x 33 mm(1.3") 18.2 kg (40.1lbs) 60 cells in series (6 x 10 matrix) (Hyundai cell) 4 mmz (12AWG) cables with polarized weatherproof connectors, IEC certified (UL listed), Length 1.0 In (39.4) IP65, weatherproof, IEC certified (UL listed) 3 bypass diodes to prevent power decrease by partial shade Front Glass: Anti -reflection coated glass, 3.2 mm (0.126") Encapsulant : EVA I Back Sheet: Weatherproof film Clear anodized aluminum alloy type 6063 (Black color) Module Diagram (unit:mm) Mono -Crystal line Si Type -Front Side View 4.32 (109.65) 712 00.26(6.6) (180.85) 00.35(9) O 0 at o 0 m a • f7i 0.35 (9) 11.44 (290.5) 38.1 (967) 39.4 (1007) Printed Date : 052020 /1° Sales & Marketing Printed onFSCcertified Sales@hyundai-es.co.kr FSC e1 friendlypaper. Installation Safety Guide • Only qualified personnel should install or perform maintenance. • Be aware of dangerous high DC voltage. • Do not damage or scratch the rear surface of the module. • Do not handle or install modules when they are wet. Nominal Operating Cell Temperature 46'Cf2 Operating Temperature -40 - 85'C Maximum System Voltage DC 1,000 V Maximum Reverse Current 20A I-V Curves Current [A] 10 8 r s 5 4 Incid. Inad =1 OOOW/1�4,5.'l 3 — Operating CeII Te 2 — Operabrg CeII Te — Operating Cell TeOpeating Cell Te 0 0 5 10 15 20 25 30 35 40 45 Voltage I V I Current [A] 12 1D Cell temp. —hcid_Irrad=1,000W/m' =25C 8 j-1.0 id.Ined=800WIW s 4id. Ined=600WIW Ined=400W/m° z — Incid. Inad = 200W/m' 0 0 10 20 30 40 voltage[V] 1.30(33) A HYUNDAI ENERGY SOLUTIONS Printed Date: 0S2020 DATE: 07/15/2021 PROJECT NAME & ADDRESS E 04 O U p E Q w Y M 0 0 �U¢-1 1 M w IY LU 0 > W Lo CU X Z Cn =� LLI 00 (1) W U) a c� w O/ — � *k _ N J �O a " G`I L CU E W SHEET NAME EQUIPMENT SPECIFICATION SHEET SIZE ANSI B 11" X 17" SHEET NUMBER PV-4 Data Sheet Enphase Microinverters Region: AMERICAS Enphase IQ7and IQ 7+ Microinverters 9 To learn more about Enphase offerings, visit enphase.com The high-powered smart grid -ready Enphase IQ 7 Micro- and Enphase IQ 7+ Micros" dramatically simplify the installation process while achieving the highest system efficiency. Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy-, Enphase IQ Battery'", and the Enphase Enlighten'" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power -on testing, enabling Enphase to provide an industry -leading warranty of up to 25 years. Easy to Install Lightweight and simple Faster installation with improved, lighter two -wire cabling Built-in rapid shutdown compliant (NEC 2014 & 2017) Productive and Reliable Optimized for high powered 60-cell and 72-cell* modules More than a million hours of testing Class II double -insulated enclosure UL listed Smart Grid Ready Complies with advanced grid support, voltage and frequency ride -through requirements Remotely updates to respond to changing grid requirements Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) * The IQ 7+ Micro is required to support 72-cell modules. n ENPHASE. Enphase IQ 7 and IQ 7+ Microinverters p ATLANTIC KEY ENERGY LLC 7006 STAPOINT CT STE B WINTER 32792 PARK, FL +1 (407) 988-0278-0273 INPUT DATA (DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W - 350 W + 235 W - 440 W + Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V - 37 V 27 V- 45 V Operating range 16 V - 48 V 16 V - 60 V REVISIONS DESCRIPTION DATE REV Min/Max start voltage 22 V / 48 V 22 V / 60 V Max DC short circuit current (module Isc) 15 A 15 A Overvoltage class DC port II II DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array; No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ Microinverter Peak output power 250 VA 295 VA Signature with Seal Maximum continuous output power 240 VA 290 VA Nominal (L-L) voltage/range2 240 V / 208 V / 240 V / 208 V / 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47 - 68 Hz 47 - 68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A (L-L) branch circuit' 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A DATE: 07/15/2021 Power factor setting 1.0 1.0 PROJECT NAME & ADDRESS Power factor (adjustable) 0.85leading ... 0.85lagging 0.85 leading ... 0.85lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak efficiency 97.6 % 97.6 % 97.5 % 97.3 % CEC weighted efficiency 97.0 % 97.0 % 97.0 % 97.0 % MECHANICAL DATA Ambient temperature range -400C to +65°C E Relative humidity range 4 % to 100 % (condensing) O Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter) N _ Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket) O CO cU Weight 1.08 kg (2.38 Ibs) m C Cooling Natural convection - No fans w Y CM CO p L Approved for wet locations Pollution degree Yes PD3 J U Q J I M z M � i1 Enclosure Class 11 double -insulated, corrosion resistant polymeric enclosure � w O� W Environmental category / UV exposure rating NEMA Type 6 / outdoor 0 Q LLJ; Q CU � X FEATURES z w J w a 00 � (1) Communication Power Line Communication (PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. �y LL N Both options require installation of an Enphase IQ Envoy. w � _ Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load -break a U disconnect required by NEC 690. J 0 Compliance CA Rule 21 (UL 1741-SA) Q UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, E CAN/CSA-C22.2 NO. 107.1-01 w This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer's instructions. SHEET NAME 1. No enforced DC/AC ratio. Seethe compatibility calculator at https�//enphase.com/en-us/support/module-compatibility. ati�EQUIPMENT. 2. Nominal voltage range can be extended beyond nominal if required by the utility. SPECIFICATION 3. Limits may vary. Referto local requirements to define the number of microinverters per branch in your area. SHEET SIZE To learn more about Enphase offerings, visit enphase.com v ENPHASE. Q 2019 Enphase Energy. All rights reserved. All trademarks or brands used are the property of EnphaseANSI Energy, Inc. "NCI B 2019-3-26 11 " X 17" SHEET NUMBER PV-5 Data Sheet Enphase Networking Enphase IQ Combiner 3 (X-IQ-AM1-240-3) U� LISTED To learn more about Enphase offerings, visit enphase.com The Enphase IQ Combiner V with Enphase IQ Envoy'' consolidates interconnection equipment into a single enclosure and streamlines PV and storage installations by providing a consistent, pre -wired solution for residential applications. It offers up to four 2-pole input circuits and Eaton BR series busbar assembly. Smart Includes IQ Envoy for communication and control Flexible networking supports Wi-Fi, Ethernet, or cellular Optional AC receptacle available for PLC bridge Provides production metering and optional consumption monitoring Supports Ensemble Communications Kit for communication with Enphase Encharge'" storage and Enphase Enpower'" smart switch Simple Reduced size from previous combiner Centered mounting brackets support single stud mounting Supports back and side conduit entry Up to four 2-pole branch circuits for 240 VAC plug-in breakers (not included) 80 A total PV or storage branch circuits Reliable Durable NRTL-certified NEMA type 3R enclosure Five-year limited warranty UL listed ENPHASE. Enphase IQ Combiner 3 MODEL NUMBER IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy'" printed circuit board for integrated revenue grade PV X-IQ-AM1-240-3 production metering (ANSI C12.20 +/- 0.50/) and optional* consumption monitoring (+/-2.5 0). ACCESSORIES and REPLACEMENT PARTS (not included, order separately) Enphase Mobile Connect" CELLMODEM-03 (4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01 (3G/5-year data plan) microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, CELLMODEM-M1 (4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring* CT Split core current transformers enable whole home consumption metering (+/- 2.5i). CT-200-SPLIT * Consumption monitoring is required for Enphase Storage Systems Ensemble Communications Kit Installed at the IQ Envoy. For communications with Enphase Encharge'" storage and Enphase COMMS-KIT-01 EnpowerT' smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner'" ATLANTIC KEY ENERGY LLC 7006 STAPOINT CT STE B WINTER PARK, FL 32792 +1 (407) 988-0273 REVISIONS DESCRIPTION I DATE I REV and allows wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers. Signature with Seal BRK-10A-2-240 Circuit breaker, 2 pole, 10A, Eaton BR210 BRK-15A-2-240 Circuit breaker, 2 pole, 15A, Eaton BR215 BRK-20A-2P-240 Circuit breaker, 2 pole, 20A, Eaton BR220 EPLC-01 Power line carrier (communication bridge pair), quantity - one pair XA-SOLARSHIELD-ES Replace the default solar shield with this Ensemble Combiner Solar Shield to match the look and feel of the Enphase Enpower" smart switch and the Enphase Encharge'" storage system XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3 (required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3 ELECTRICAL SPECIFICATIONS DATE: 07/15/2021 Rating Continuous duty PROJECT NAME & ADDRESS System voltage 120/240 VAC, 60 Hz Eaton BR series busbar rating 125 A Max. continuous current rating (output to grid) 65 A Max. fuse/circuit rating (output) 90 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) Max. continuous current rating (input from PV) 64 A EO Max. total branch circuit breaker rating (input) 80 A of distributed generation / 95 A with IQ Envoy breaker included N U Envoy breaker 10A or 15A rating GE Q-line/Siemens Type QP /Eaton BR series included O CO (0 O C)', E Production Metering CT 200 A solid core pre installed and wired to IQ Envoy m Q M C)}, MECHANICAL DATA " Q z O LL CM Dimensions (WxHxD) 49.5 x 37.5 x 16.8 cm (19.5" x 14.75" x 6.63"). Height is 21.06" (53.5 cm with mounting brackets). Weight 7.5 kg (16.5 Ibs) w^ ry LU Lo Q- Ambient temperature range -401 C to +461 C (-40° to 115- F) IJ IJ ; C) LL{O X Cooling Natural convection, plus heat shield Z U J LLI CD N — Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction Q (n a Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors X mow/ L 1_ N 60 A breaker branch input: 4 to 1/0 AWG copper conductors L LI CD = Main lug combined output: 10 to 2/0 AWG copper conductors J U o Neutral and ground: 14 to 1/0 copper conductors ILL Always follow local code requirements for conductor sizing. (6 Altitude To 2000 meters (6,560 feet) E w INTERNET CONNECTION OPTIONS Integrated Wi-Fi 802.11b/g/n Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included) Cellular CELLMODEM-M1 4G based LTE-M cellular modem (not included). Note that an Enphase Mobile Connect cellular modem is required for all Ensemble installations. SHEET NAME COMPLIANCE _ Compliance, Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003 EQUIPMENT Production metering: ANSI C12.20 accuracy class 0.5 (PV production) Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1 SPECIFICATION SHEET SIZE I o learn more about tnpnase otterings, visit enphase.com © 2021 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3, and other trademarks or service names are the n E N P H AS E ANSI B trademarks of Enphase Energy, Inc. Data subject to change. 2021-05-20 11" X 17" SHEET NUMBER PV-6