HomeMy WebLinkAbout2111-0523 GENERAL NOTES: DOORS AND WINDOWS:
1. GENERAL
2. DESIGN CODE A. THE DESIGN PRESSURES FOR THE DOORS AND WINDOWS SHALL BE NOT LESSTHAN THE VALUES SHOWN IN THE SCHEDULE OR
A. TO THE BEST OF THE DESIGN PROFESSIONALS KNOWLEDGE,THESE DOCUMENTS HAVE BEEN PREPARED WITH AND ARE IN PLAN.THESE DESIGN PRESSURES ARE LISTED IN ALLOWABLE(ASD)WIND PRESSURES.
COMPLIANCE WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE FIRE SAFETY STANDARDS AS DETERMINED BY B. ALL EGRESS WINDOWS SHALL MEET FBC SECTION 1029 OR FBC-R 310,AS APPLICABLE.
THE LOCAL AUTHORITY IN ACCORDANCE WITH CHAPTERS 553 AND 633 OF THE FLORIDA STATUTES.THESE DOCUMENTS MEET OR C. GLAZING IN HAZARDOUS LOCATIONS SHALL COMPLY WITH FBC-R 308.
EXCEED THE REQUIREMENTS OF: D. SHUTTERS(IF INSTALLED)SHALL MEET FBC-R 301.11.2.
B. 2020 FLORIDA BUILDING CODE,SEVENTH EDITION. E. OPENING NOTATIONS
2. STRUCTURE SPECIFICATIONS a. WIDTH(FEET INCHES)x HEIGHT(FEET INCHES).EXAMPLE:21068=T-10"WIDE x U-8"TALL
A. BUILDING OCCUPANCY CATEGORY: II b. TWIN OR DOUBLES:EXAMPLE(2)3050=TWO V-0"WIDE x 5'-0"TALL WINDOWS MULLED TOGETHER
B. CONSTRUCTION TYPE: V-B 2. MATERIALS
C. OCCUPANCY CLASSIFICATION: R-2 A. THE EXTERIOR DOORS AND WINDOWS SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S NOTICE OF
D. WIND SPEED APPROVAL(MIAMI NOA OR FBC APPROVAL).
a. ULTIMATE(LRFD)= 163 MPH B. ANCHORS SHALL BE STAINLESS STEEL.
b. ALLOWABLE(ASD)= 133 MPH C. THE EXTERIOR DOORS AND WINDOWS MUST WITHSTAND THE IMPACT OF WIND BORNE MISSILES,OR SHALL BE PROTECTED
E. WIND EXPOSURE CATEGORY: D WITH AN APPROVED IMPACT RESISTANT COVERING.
F. ENCLOSURE CLASSIFICATION: ENCLOSED D. EACH UNIT SHALL BEAR A LABEL WITH THE MANUFACTURER'S NAME AND DESIGN PRESSURES,WHICH SHALL REMAIN UNTIL
G. INTERNAL PRESSURE COEFFICIENT: +/-0.18 FINAL INSPECTION IS PASSED BY LOCAL AUTHORITY HAVING JURISDICTION,
H. WIND-BORNE DEBRIS AREA: YES E. ALL FENESTRATIONS(WINDOWS,DOORS,AND GLAZED BLOCK)SHALL COMPLY WITH THE FOLLOWING U FACTORS AND
1. REFER TO DRAWINGS FOR STRUCTURE HEIGHT AND AREA S.H.G.C. (FBC-EC R402.3)OR PROVIDE A PERFORMANCE BASED ENERGY CODE(FBC E400.3).
J. STRUCTURAL LOADS AND DESIGN PRESSURES LISTED IN THESE PLANS ARE SHOWN IN ALLOWABLE(ASD)UNLESS NOTED OTHERWISE. a. IMPACTGLAZING: U FACTOR=0.65 MAXIMUM AND S.H.G.0=0.25 MAXIMUM
3. PROJECT REQUIREMENTS: F. SELF-ADHERED MEMBRANES USED AS FLASHING SHALL COMPLY WITH AAMA 711.FLUID APPLIED MEMBRANES SHALL MEET
A. THE CONTRACTOR AND SUB-CONTRACTORS SHALL STRICTLY ADHERE TO ALL APPLICABLE CODES DURING THE COURSE OF AAMA 714,THE FLASHING SHALL EXTEND PAST THE SURFACE OF THE EXTERIOR WALL FINISH.ALL LISTED PRODUCTS BELOW
CONSTRUCTION,INCLUDING ALL STATE,CITY AND COUNTY BUILDING,ZONING,ELECTRICAL,MECHANICAL,PLUMBING AND ARE APPROVED ALONG WITH ADDITIONAL PRODUCTS THAT MEET OR EXCEED THEIR PERFORMANCE SPECIFICATIONS.
FIRE CODES,AS WELL AS ANY APPLICABLE HOMEOWNER ASSOCIATION REQUIREMENTS. a. LIQUID FLASHING:OSI QUAD FLASH,PROTECTOWRAP LWM200,OR TREMCO DYMONIC 100.
B. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL NOTIFY THE DESIGN PROFESSIONAL OF RECORD OF 3. EXECUTION
ANY DISCREPANCIES OR CONFLICT WITH APPLICABLE CODES PRIOR TO CONSTRUCTION. A. PRIOR TO INSTALLATION,ALL FRAMES AND BUCKS SHALL BE CHECKED FOR RACK,TWIST,AND OUT OF SQUARE.
C. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR SAFETY PROCEDURES,THE MEANS AND METHODS OF B. ALL ANCHORS INSTALLED IN CONCRETE OR MASONRY SHALL HAVE SEALANT INSERTED INTO THE HOLE AFTER CLEANING THE
CONSTRUCTION,TECHNOLOGIES OR THE FAILURE OF THE CONTRACTOR TO COMPLETE THE WORK IN ACCORDANCE WITH DUST FROM THE HOLE AND DIRECTLY BEFORE ANCHOR IS INSERTED.
DRAWINGS,SPECIFICATIONS OR THE RELATED CODES. C. FOLLOW FMA(FENESTRATION MANUFACTURERS ASSOCIATION)GUIDELINES FOR FLASHING ALL OPENINGS.
D. THE CONTRACTOR SHALL FULLY REVIEW ALL ITEMS CONTAINED IN THE DRAWINGS AND SHALL COORDINATE ALL DIMENSIONS, a. CAULK ALL INSIDE CORNERS OF OPENINGS WITH AN APPROVED SEALANT.
' LOCATE DEPRESSED SLABS,SLOPES,DRAINS,OUTLETS,RECESSES,EMBEDS,SLEEVES,ETC, b. APPLY AN APPROVED FLASHING TO ALL FOUR SIDES OF OPENINGS.
E. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO DETERMINE THE ERECTION PROCEDURES AND SEQUENCING. C. APPLY A HEAVY,UNINTERRUPTED BEAD OF APPROVED SEALANT TO THE BUCKS PRIOR TO ATTACHING TO THE
F. NOTES,DETAILS,AND SECTIONS ON THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW OPENING PER WINDOW/DOOR DETAILS.
GENERAL REQUIREMENTS THROUGHOUT."TYPICAL"DETAILS SIMPLY REFER TO ALL CONDITIONS TREATED SIMILARLY. d. SEAL BUCKS WITH AN APPROVED FLASHING MATERIAL.
CONTRACTOR SHALL MAKE MINOR MODIFICATIONS TO ACCOMMODATE MINOR SIMILAR VARIATIONS. e. INSTALL DOOR/WINDOW AND APPLY BEAD OF APPROVED SEALANT AROUND PERIMETER.
G. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES OR MODIFICATIONS WITHOUT EXPRESSED WRITTEN APPROVAL OF D. APPROVED CORROSION RESISTANT FLASHING SHALL BE APPLIED IN SHINGLE FASHION IN A MANNER TO PREVENT ENTRY OR
THE ENGINEER OF RECORD IN ADVANCE. PENETRATION OF WATER TO THE BUILDINGS STRUCTURAL FRAMING COMPONENTS.
E. THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH.
F. CONTRACTOR SHALL FOLLOW PRODUCT APPROVAL FOR MULLION COMPONENTS(MULL BAR,CLIPS,CONNECTORS)FOR
SPECIFIED DESIGN PRESSURE FOR EACH SPECIFIC OPENING ON PROJECT.
G. WHEN TWO COMPONENTSJOIN ATA MULL BAR,THE CONTRACTOR SHALL FULLY SEAL AND ADD A COVER STRIP TO SEAL THE
JOINT BETWEEN COMPONENTS.
SCOPE OF WORK: H. CONTRACTOR IS RESPONSIBLE FOR WATER TESTING THE OPENINGS AND VERIFYING PROPER WEATHERPROOFING AND
1. REPLACE WINDOWS AND DOORS PER LAYOUT, DETAILS AND MANUFACTURERS PRODUCT APPROVAL. PERFORMANCE OF THE COMPLETED OPENINGS.
2. THE SIZE AND OPERATION OF THE COMPONENT IS NOT CHANGING FROM THE EXISTING COMPONENT.
3. OPENINGS MARKED WITH LOWERCASE i INDICATE IMPACT RATED.ALL OTHER ARE NON-IMPACT RATED File Cn�PF_
AND THE EXISTING OPENING PROTECTION SHALL REMAIN. 6 0 �/( 5V
01 COMPLIANCE No. Description Date
�%. NCE°° SC 4'
SAND DOLLAR SHORES �0,�$�-'\OENSF C�fT��i ISSUE DATE: 04J08/2021 PROJECT NO: 20F023
.� ' , TE SCHLITT
N COMPONENTS AND CLADDING No81238 t? 'v ENGINEERING, LLC. I. STATUS: PERMITSET General Notes
cA# 32295
dvUj
�-7
41 ❑ S OCEAN DRIVE �O°° STATE OF ° � i 555 lND1AN RIVER BLDV. SUITE B-1 45 DRAWN BY: AM f'j [] ,
OP,°°�,-% VERD BEACH, FL 32950 m
N ,, ORIo° � 772.36D.4998 O REVIEWED BY: TS OF
v JENSEN BEACH, FL ST. LUCIE COUNTY, 34957 4ro,oN A y111���aPr,z9,2o 1 INFO@S0HLITTENGINEERINGIDoM 1 3
Design Professional's electronic or digital seal or signature is effective only as to that version of this document as originally published by Design Professional. Design Professional is not responsiblefor any subsequent modification,corruption,or unauthorized use ofsuch document. To verify the validity or applicability of the seal or signature,contact Design Professional.
Window and Door Schedule
Size Design Pressure
Mark Type (WxH) (PSF Min.)
1 SGD 91-ONG-8" +47/-81
A Window-Single Hung 3'-1"x 3'-2 3/8" +52/-94
B Window-Fixed 3'-1"x 3'-2 3/8" +52/-94
UNIT 508
i
A A A
No. Description Date
f
IL
m ruurn
N � ��N G°E / , ISSUE DATE: 04/08/2021 PROJECT NO: 20F023
SAND DOLLAR SHORES �o �� NSF°°°� .
°T '% ' , TE SCHLITT
N �t No.81238 at+ v ENGINEERING, LLC. N STATUS: PERMITSET BuildingD - Unit 508
COMPONENTS AND CLADDING = ° _ ' CA# 32295
r�7 v�a1/ G5 ° u N
0 / 4 1 ❑ S ❑ C EA N DRIVE O°' STATE OF °°��: 555 INDfAN RIVER BLDV. SUITE B-145 " DRAWN BY: AM S1 . 10
N ��0. %A VERD BEACH, FL 32950
m
7722.350.4998 04 JENSEN BEACH, FL ST. LUCIE COUNTY, 34957 '���f,°°j A�����,Apr.29,20 INFO@SCHLITTEN6INEERING.COM D REVIEWED BY: TS 2 aF 3
Design Professional's electronic or digitalseal orsignature is effective only as to thatversion of this documental originally published by Design Professional. Design Professionalis not responsiblefor any subsequent modification,corruption,or unauthorized use ofsuch document. To verify the validity orapplicability of the seal or signature,contact Design Professional
a a a. INTERIOR FINISHES,TRIM PER OWNER
i b a. INTERIOR FINISHES,TRIM PER OWNER b. COAT MASONRY WITH LIQUID
b. COAT MASONRY WITH LIQUID k b WATERPROOFING,THEN ADD 3 LINES OF
WATERPROOFING,THEN ADD 3 LINES OF 0'- 1 1/4" SEALANT AT MASONRY,THEN INSTALL 2x6
c SEALANT AT MASONRY,THEN P.T. BUCK j MIN. OR 2x8 P.T.BUCK
d C. SEALANT AT FLANGE TO BUCK d e C. SEALANT AT FLANGE TO BUCK
a f d. 1/4' MAX. NON-DEGRADABLE SHIM W/ d. 1/4' MAX. NON-DEGRADABLE SHIM W/
h BACKER ROD AT PERIMETER,TRIM SHIMS �_ — a g BACKER ROD AT PERIMETER,TRIM SHIMS
e 1/4" FROM FACE m 1/4" FROM FACE
® e. 1/4"0 TAPCONS AT 10"O.C. MAX. c d e. 3/1e"0.TAPCONS AT 10"O.C. MAX.
STAGGERED,THEN INSTALL LIQUID STAGGERED,THEN INSTALL LIQUID
9 WATERPROOFING OVER FACE OF BUCK h WATERPROOFING OVER FACE OF BUCK
j f. EXT. FINISH W/DRIP EDGE, LEAVE 1/4"GAP e e f. N/A
AT DOOR,THEN SEAL c g. EXT. FINISH W/DRIP EDGE, LEAVE 1/4'GAP
3 HEAVY CONT. LINES OF SEALANT AT I AT WINDOW,THEN SEAL
OUTSWIN
OPTIONAL N RECESSED SILL AT g'G/SLIDING DOORS THRESHOLD TO CONC.;THEN 1 b/4 p _I b h. SLOPE TO DRAIN, LEAVE 1/4'GAP AT TAPCONS AT 10"O.C. MAX.STAGGERED WINDOW,THEN SEAL
(SEE NOTE#2) 1. PRECAST OR POURED IN PLACE SILL
h. SEALANT AT BUCK TO MASONRY I. SEALANT AT BUCK TO MASONRY
I. LINTEL PER PLAN/SCHEDULE k. LINTEL PER PLAN/SCHEDULE
j. FILLED CELL W/#5 VERT. I. FILLED CELL W/#5 VERT.
NOTES:
M. PVC CASING BEAD W/REINFORCEMENT AS
1. TAPCON ANCHORS TO MASONRY/GONG.SHALL HAVE 1.25" EMBEDMENT MINIMUM. NOTES:
NEEDED PER CODE.
2. DO NOT INSTALL ANCHORS IN SILL UNLESS NOTED BY PRODUCT APPROVAL. 1. TAPCON ANCHORS TO MASONRY SHALL HAVE 1.25" EMBEDMENT MINIMUM.
3. LIQUID WATERPROOFING SHALL MEET FBC R-703.4 OR FBC 1405.4 AS APPLICABLE,SEE GENERAL NOTES. 2. DO NOT INSTALL ANCHORS IN WINDOW SILL UNLESS NOTED BY PRODUCT APPROVAL.
4. SEE PRODUCT APPROVAL FOR ALTERNATE ATTACHMENT METHOD. 3. LIQUID WATERPROOFING SHALL MEET FBC R-703.4 OR FBC 1405.4 AS APPLICABLE,SEE GENERAL NOTES.
4. SEE PRODUCT APPROVAL FOR ALTERNATE ATTACHMENT METHOD.
Door Detail at CMU 0 Window Detail at CMU
S2.1 3/4"= F-O" S
Florida Product A PRODUCT APPROVAL NOTE:royal Listings I HAVE REVIEWED THE ABOVE COMPONENTS OR CLADDING AND I
Building Design Pressures Product Design Pressures HAVE APPROVED THEIR USE IN THIS STRUCTURE.THESE PRODUCTS
Category-Subcategory Approval Number Manufacturer Model Number (+PSF/-PSF) (+PSF/-PSF) PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS SPECIFIED BY
Exterior Doors-Sliding NOA 20-0429.07 PGT 670 Alum. Non-Impact See Schedule +90/-140 CURRENT CODE PROVISIONS.
Exterior Doors-Sliding NOA 20-07729.08 Windoor, Inc. 560 Impact See Schedule +93.2/-93.2 HARD COPIES OF THE PRODUCT APPROVALS SHALL BE AVAILABLEON SITE FOR INSPECTIONS.
Window-Mullion NOA 20-0406.03 PGT PGT Clipped Extruded Alum.Tube +52/-94 +170/-170
Window-Fixed NOA 20-0401.09 PGT PW7620A Alum. Non-Impact See Schedule +100/-145.8
Windows-Single Hung NOA 20-0401.12 PGT SH7600A Alum. Non-Impact See Schedule +80/-130
Windows-Single Hung NOA 20-0722.20 Windoor, Inc. 360 Alum. impact See Schedule +100/-200 No. Description Date
F
IL
1111111/f
o SAND DOLLAR SHORES ����9- CE°ESCh�/ �
� �� �o°° \C NS l i� ' � ISSUE DATE: 04/08/2021 PROJECT NO: 20F023
° TE SCHLITT
N COMP No.81238
_ COMPONENTS AND CLADDING ?t9TAE
°t : ' ENGINEERING, LLC. <` STATUS: PERMITSET
_ CA# 32295 Details
N o' ��
r/ �Ao W� N
N / 4 1 ❑ S OCEAN DRIVE 001° F 1 555 INDIAN RIVER BLDV. SUITE B-145 DRAWN BY: AM S2 . 1
N , j�J'°°c� , VERO BEACH, FL 3296D M
v JENSEN BEACH FL ST. LUCIE COUNTY 34957 '�. fONAI ��� INFO<7a BCHLITTENG1NEERING.CDM C REVIEWED BY:
r r 11111 j10 Apr.29,20 1 U TS O F 3
Design Professional's electronic or digital seal or signature is effective only as to that version of this document as originally published by Design Professional. Design Professional is not responsible for any subsequent modification,corruption,or unauthorized use ofsuch document. To verify the validity or applicability of the seal or signature,contact Design Professional.