HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTS 1/21/2021 Florida Building Code Online
Business • Professional Regulation
-+oar
SCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Searc-
Product Approval
USER:Public User
r+
P>Product or AQd¢atlon Search>ggolicatnon List>Appllcatlon Detail
FL* FL5259-1131
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archlved
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach,FL 33442
(954)233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@ polygiass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach,FL 33442
(866)802-8017
u spolyglasstechnicai@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach,FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Underiayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 10/21/2022
Validated By John W. Knezevich,PE
Validation Checklist-Hardcopy Received
Certificate of Independence FL5259 R31 COI 2020 01 COI NIEMINEN.odf
Referenced Standard and Year(of Standard) Standard Y!u
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
www.flofidabuilding.org/pr/pr app dU.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOlip3cPzPSPEkchxoaj6Vjgl%2bg°/,3d%3d 1/2
1/21/2021 Florida Building Code Online
I
FM 4474 2011
FRSA/TRI,Sixth Edition 2018
UL1897 2015
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/22/2020
Date Validated 10/26/2020
Date Pending FBC Approval 11/01/2020
Date Approved 12/15/2020
Date Revised 12/21/2020
Summan(of Products
FL* Modell,Number or Description
Name
5259.1 Polyglass Roof Roofing underlayments
Underlayments
----- -----------------t- — -
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL5259 R31 Il 2020 09 30 FINAL ER POLYGLASS UNDERL.AYMENTS FL5259-
Approved for use outside HVHZ:Yes S)_LRdf
Impact Resistant: N/A Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes
Other: 1.)The design pressure in this Evaluation Reports
application relates to one particular FL5259 R31 AE 2020 09 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
undedayment system for use in tile roof g3Lp_Qj
systems. Refer to ER Section 5.8.3 for other Created by Independent Third Party: Yes
systems and associated maximum design
pressures. 2.)Refer to ER Section 5 for
other limits of use.
NeMt
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer, Flonda. ::Privacy.Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails
provided may be used for official communication wth the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please dick here.
Product Approval Accepts:
®® ® [0
Credit Card
Safe
www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS°/a2fegOlip3cPzPSPEkchxoaj6Vjg1%2bg%3d%3d 2/2
NEM01 etc.
Certificate of Authorization N32455
3S3 Christian Street, Unit#13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
EVALUATION •
Polyglass USA,Inc. Evaluation Report P12060.02.09-1127
1111 West Newport Center Drive FL5259-R31
Deerfield Beach, FL 33442 Date of Issuance:02/24/2009
(954)233-1330 Revision 27:09/30/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen, P.E.for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 7" Edition(2020)Florida Building Code sections noted herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and
FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of our
Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s), the
Quality Assurance or the production facility location(s). NEMO ETC,LLC requires a complete review of its Evaluation Report relative
to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEVIOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 17.
Prepared by: „•�����..
00
�f�.stts fT�t9.:•���
Robert J.M. Nieminen,P.E. s �•_,:.cj '
Florida Registration No.59166,Florida DCA ANE1983 ......,,.•• The facsimile seal appearing was authorized by Robert Nieminen,P.E.on
CERTIFICATION OF INDEPENDENCE; 09/30/2020. This does not serve as an electronically signed document.
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are, in any way,the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
CQ2019 NEW ETC,LLC
t_
IRNEMOJetc.
ROOFING COMPONENT EVALUATION:
I SCOPE:
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc., have demonstrated compliance with the
following sections of the 71 Edition (2020) Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein.
STANDARDS:2.
Section pmpe RafWardYear
1504.3.1 Wind resistance FM 4474 2011
1504.3.1 Wind resistance UL 1897 2015
1507.1.1/R905.1.1 Material standard ASTM D226 2009
1507.1.1,1507.2.4,1507.2.9.2/ Material standard ASTM D1970 2015
R905.1.1,R905.2.8.2
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
1507.11.2/R905.11.2 Material standard ASTM D6163 2015
1507.11.2/R905.11.2 Material standard ASTM D6164 2011
1507.11.2/R905.11.2 Material standard ASTM D6222 2011
1507.11.2/R905.11.2 Material standard ASTM D6509 2015
TAS 110 Accelerated Weathering ASTM D4798 2011
3. REFERENCES-.
Enft Examination Reference 20 Jlillft Examination Relwang 20
ERD(TST 60491 Wind Uplift 11757.09,01-1 09/13/2001 ERD(TST 6049) 30/90 physicals PLYG-SC11900.03.17 03/10/2017
ERD(TST 6049) Wind Uplift 11776.06.02 01/16/2003 ERD(TST 6049) TAS 103 PLYG-SC12115.08.17 08/09/2017
ERD(TST 6049) Wind Uplift P1740.01.07 01/04/2007 ERD(TST 6049) TAS 103 PLYG-SC13035.08.17 10/31/2017
ERD(TST 6049) ASTM D1970 P5110.04.07-1 04/11/2007 FM(TST 1867) Wind Uplift 3004091 01/12/2000
ERD(TST 6049) Wind Uplift P9260.03.08 03/21/2008 ICC-ES(EVL 2396) IBC Compliance ESR-1697 04/01/2019
ERD(TST 6049) Wind Uplift P30540.11.09-111 11/30/2009 M-D(CER 1592) HVH2 Compliance NOA 17-0614.22 07/06/2017
ERD(TST 6049) Tensile Adhesion P11030.11.09.1 11/30/2009 MTI(TST 2508) ASTM D4798 1X20H7A 04/01/2008
ERD(TST 6049) Wind Uplift P11030.11.09-2 11/30/2009 NEMO(TST 6049) ASTM D1970 4-PLYG-18-004.03.18 03/29/2018
ERD(TST 6049) ASTM D4977 P11030.11.09-3 11/30/2009 NEMO(TST 6049) Wind Uplift 4L-PLYG-18-003.01.19 01/11/2019
ERD(TST 60491 ASTM 01970 P33360.06.10 06/25/2010 NEMO(TST 6D49) ASTM D6163 4S-PLYG-18-002.01.19-A 01/24/2019
ERD(TST 6049) TAS 103 P33370.03.11 03/02/2011 NEMO(TST 6049) ASTM D6222 4S-PLYG-18-002.05.19-C 05/20/2019
ERD(TST 6049) Tensile Adhesion P33370.04.11 04/26/2011 NEMO(TST 6049) ASTM D1970 4j-PLYG-I9-SSUDL-OO.A 09/10/2019
ERD(TST 6049) ASTM D1970 P37300.10.11 10/19/2011 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.10.19-G 10/08/2019
ERD(TST 6049) TAS 103 P40390.08.12-1 08/06/2012 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.10.19-1 10/08/2019
ERD(TST 6049) Tensile Adhesion P40390.08.12.2 08/07/2012 NEMO MT 6049) TAS 103 4S-PLYG-18-004.10.19-L 10/09/2019
ERD(TST 6049) Tensile Adhesion C41420.09.12-3 09/11/2012 NEMO(TST 60491 TAS 103 4j-PLYG.19-SSUDL-01.A 10/10/2019
ERD(TST 6049) Wind Uplift P39680.03.13 03/04/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.12.19-F 12/18/2019
ERD(TST 6049) ASTM D1970 P45370.04.13 04/26/2013 NEMO(TST 6049) TAS 103 4j-PLYG-I9-SSUDL-02.A 01/02/2020
ERD(TST 6049) Wind Uplift P1738.02.07-R2 04/29/2013 NEMO(TST 6049) ASTM D1970 4S-PLYG-18-004.01.20.H 01/14/2020
ERD(TST 6049) Wind Uplift 11757.04.01-1-RL 04/30/2013 NEMO(TST 6049) ASTM D1970 4S-PLYG-18-004.01.20.K 01/14/2020
ERD(TST 6049) ASTM D6164 P37590.03.13-3A 05/06/2013 NEMO(TST 6049) TAS 103 4S-PLYG-18-004.01.20.A 01/16/2020
ERD(TST 6049) ASTM D6509 P37590.03.13-1-R1 06/26/2013 NEMO(TST 6049) ASTM D6164 4S-PLYG-18-004.01.20.8 01/16/2020
ERD(TST 6049) Wind Uplift P41630.08.13 08/06/2013 NEMO(TST 6049) ASTM D6222 4S-PLYG-18-002.12.19-K-RI 01/07/2020
ERD(TST 6049) ASTM D4601 P45940.09.13 09/04/2013 NEMO(TST 6049) TAS 103 PLYG-SC15855.05.20.A 05/29/2020
ERD(TST 6049) Wind Uplift P11751.05.03-R1 11/26/2013 NEMO(TST 60491 TAS 103 4j-PLYG-20-SSUDL-01 07/06/2020
ERD(TST 6049) Wind Uplift P11781.11.03-R1 11/26/2013 NEMO(TST 6049) ASTM D6222 4q-PLYG-I9-SSMBB-05.A 07/23/2020
ERD(TST 6049) 30/90 physicals P45270.05.14 05/12/2014 NEMO(TST 6049) ASTM D4798/D3623 4j-PLYG-19-S5UDL-05.A 09/10/2020
ERD(TST 6049) Tensile adhesion 6020.09.14-5 09/08/2014 NEMO(TST 6049) ASTM D1970 4j-PLYG-20-SSUDL-05.A 09/30/2020
ERD(TST 6049) Tensile adhesion 6020.09A4-6 09/08/2014 NEMO(TST 6049) TAS 103 4j-PLYG-20-S5UDL-05.0 09/30/2020
ERD(TST 6049) Tensile adhesion P46520.10.14 10/03/2014 NEMO(TST 6049) TAS 103 4j-PLYG-20-SSUDL-11 09/30/2020
NEMO ETC,U.C. Evaluation Report P12060.02.09-R27
Certificate of Authorization x32455 7T"EDITION(2020)FBC NON-HVH2 EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 2 of 17
ONEMOjetc.
bib Examination Reference Date Kahn Examination Relfeten.54 2KW
ERD(TST 6049) ASTM D1970/D4798 P43290.10.14 10/17/2014 PRI(TST 5878) Tensile Adhesion PR101111 04/08/2002
ERD(TST 6049) TAS 103 PLYG-SC7550.03.15 03/24/2015 PRI(TST 5878) TAS 103 PUSA-018-02-01 07/14/2003
ERD(TST 6049) Tensile adhesion P40390.04.15 04/03/2015 PRI(TST 5878) TAS 103 PUSA-035-02-01 09/29/2006
ERD(TST 6049) TAS 103 P44360.10.14-R1 05/18/2015 PRI(TST 5878) TAS 103 PUSA-055-02-02 12/10/2007
ERD(TST 6049) Wind Uplift PLYG-SC8905.05.16-1 05/17/2016 PRI(TST 5878) ASTM D6222 PUSA-061-02-02 01/29/2008
ERD(TST 6049) ASTM D1970 PLYG-SC10130.06.16-1 06/27/2016 PRI(TST 5878) ASTM D6164 PUSA-088-02-01 07/29/2009
ERD(TST 6049) Tensile adhesion PLYG-SC10130.06.16-2 06/27/2016 Polyglass USA P/L Affidavit Mule-Hide Cross Ltg 03/01/2008
ERD(TST 5049) TAS 103 PLYG-SC10130.06.16-3 06/27/2016 Polyglass USA Materials Affidavit Polystick Compound 08/18/2011
ERD(TST 6049) ASTM D1970/D4798 PLYG-SC8080.07.16 07/16/2016 UL(QUA9625) Quality Control Service Confirmation(FL) 09/13/2018
ERD(TST 6049) Wind Uplift PLYG-SC1202510.16 10/1212016 UL(QUA9625) Quality Control Service Confirmation(TX) 11/07/2019
ERD(TST 6049) TAS 103 PLYG-SC13040 12.16 12/27/2016 UL(QUA96251 Quality Control Florida BCIS Current
4. ODDESCRIPTION:
Product Material Standard Plant(s) Description
4.1 Elastobase ASTM D6163 FL Fiberglass-reinforced,SBS modified bitumen base sheet
4.2 Elastobase P ASTM D6164 FL Polyester-reinforced,SBS modified bitumen base sheet
4.3 Elastoflex S6 G ASTM D6164 FL, PA Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TRI 09-18
4.4 Elastoflex 56 G FR ASTM D6164 FL Polyester-reinforced,SBS modified bitumen cap sheet
FRSA/TRI 09-18
4.5 HydraGuard Dual Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polyester fabric surface
4.6 HydraGuard Tile Pro ASTM D1970 FL Nominal 60-mil thick dual-layer rubberized asphalt
FRSA/TRI 09-18 waterproofing membrane,fiberglass reinforced,with a
polyester fabric surface
4.7 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI 09-18
4.8 Mule-Hide SA-APP Cap Sheet ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet
(FR) FRSA/TRI 09-18
4.9 Polyflex G ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSA/TRI 09-18 use as an alternate to Heat Applied "Cap Sheet" in the
"Two Ply System"from FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth
Edition beneath mechanically fastened or adhered tile
roof systems
4.10 Polyflex G FR ASTM D6222 FL Polyester-reinforced,APP modified bitumen cap sheet for
FRSAITRI 09-18 use as an alternate to Heat Applied "Cap Sheet"in the
"Two Ply System"from FRSAJTRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth
Edition beneath mechanically fastened tile roof systems
4.11 PolyfIex SA P ASTM D6222 FL,TX Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRI 09-18
4.12 Polyflex SA P FR ASTM D6222 FL,TX Polyester-reinforced,APP modified bitumen cap sheet
FRSA/TRl 09-18
4.13 Polyglass Base ASTM D6509 FL Fiberglass-reinforced,APP modified bitumen base sheet
4.14 Polyglass G2 Base Sheet ASTM D4601 AL Fiberglass-reinforced,asphaltic base sheet
NEMO ETC,I.I.C. Evaluation Report P32060.02.09-R27
Certificate of Authorization#32455 7'"EDITION(2020)F8C NON-HVH2 EVALUATION FLS259-1191
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 3 of 17
ONEMOletc.
4. •••• DESCRIPTION:
Product Material Standard Plant(s) Description
4.15 Polystick IR-Xe ASTM D1970 FL, PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
membrane,glass fiber reinforced,with an aggregate
surface
4.16 Polystick MTS Plus ASTM D1970 FL,NV, Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 PA,TX membrane,glass fiber reinforced,surfaced with
polyolefinic film surface
4,17 Polystick MU-X ASTM D19701 FL,NV,PA Nominal 54-mil thick dual-layer rubberized asphalt
waterproofing membrane,fiberglass reinforced,with a
polypropylene film surface
4.18 Polystick TU Max ASTM D1970 FL,PA,TX Nominal 60-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane with a 190 g/ml polyester fabric surface
4.19 Polystick TU P FRSA/TRI 09-18 FL, PA,TX Nominal 130-mil thick rubberized asphalt waterproofing
membrane,glass-fiber/polyester reinforced,with a
granular surface
4.20 Polystick TU Plus ASTM D1970 FL, PA,TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane,glass fiber reinforced,with a polyester fabric
surface
4.21 Polystick XFR ASTM D1970 NV,TX Nominal 80-mil thick rubberized asphalt waterproofing
FRSA/TRI 09-18 membrane,glass fiber reinforced,surfaced with a
textured film surface
5. LIMITATIONS:
5.1 This is a Building Code Evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E.are,in any way,the Designer of Record for
any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless
retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with
FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations
regarding roof assembly fire classification. Referto FBC 2603 for requirements and limitations concerning the use of foam plastic
insulation.
5.5 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed,a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
I Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D216 roofing felt in a dry condition,tested at standard
laboratory conditions. Agreement between purchaser and seller,as set forth in Section 4.3,Note 1 of ASTM D1970-15,should be established as to slip resistance.
MEMO ETC,I.I.C. Evaluation Report P12060.02.09-1127
Certificate of Authorization#31455 7"EDITION(2020)FBC NON.HVH2 EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 4 of 17
I
5.6 Allowable Roof Covers: ONEMOletc.
�. TABLE 1: ROOF COVER OPTIONS
Clay and Concrete Tile — Slate or
Asphalt (15073 Metal Wood
Shingles -- ) Slate-Type _—
Mechanical Adhesive- Panels Shingles Shingles Shakes(lso7.9)
(1507.2) Attach Set B B Shingles
(1507.4) (1507s) (1507.7) (lsozs)
Elastobase Yes Yes Yes Yes Yes Yes Yes Yes
(Alternate to (as Base Sheet, (as Base Sheet, (Alternate to (Alternate to (Alternate to (Alternate to D226, (Alternate to 0226,
D226,Type II) See 5.8.3) See 5.8.3) D226,Type 11) D226,Type 11) D226,Type II) Type 11) Type 11)
Yes Yes Yes Yes Yes Yes Yes Yes
Elastobase P (ARemate to (as Base Sheet, (as Base Sheet, (Alternate to (Altemate to (Alternate to (Alternate to D226, (Alternate to D226,
D226,Type II) See 5.8.3) See S.8.3) 0226,Type 11) 0226,Type II) 0226,Type 11) Type 11) Type 11)
Yes Yes
Polyglass Base No (as Base Sheet, (as Base sheet, No No No No No
See S.8.3) See 5.8.3)
Yes Yes
Polyglass G2 Base No (as Base sheet. (as Base sheet, No No No No No
See S.8.3) See 5.8.3)
Elastoflex S6 G No Yes Yes No No No No No
(See 5.6.1)
Elastoflex S6 G FR No Yes No No No No No No
Yes Yes
HydraGuard Dual Pro Yes No No Yes Yes Yes (pint strips,1507.1.1.3 (pint strips,2507.1.1.3
/R905.1.1.3) /R905.1.1.3)
HydraGuard Tile Pro Yes Yes Yes
Yes Yes' (See 5.6.1) Yes Yes Yes (pint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R90S.1.1.3)
Mule-Hide SA-APP Cap Sheet No Yes Yes No No No No No
(See 5.6.1)
Mule-Hide SA-APP Cap Sheet(FR) No Yes Yes No No No No No
(See 5.6.1)
Polyflex G No Yes Yes No No No No No
(See 5.6.1)
Polyflex G FR No Yes No No No No No No
Polyflex SA P No Yes Yes No No No No No
(See 5.6.1)
Polyflex SA P FR No Yes Yes No No No No No
(See 5.6.1)
Polystick IR-Xe Yes No No Yes Yes
No No Yes (joint stops,1507.1.1.3 (pint strips,1507.1.1.3
/R905.1.13) /R905.1.1.3)
Polystick MTS Plus Yes Yes No Yes Yes Yes (joint Yes Yes
strips,1507.1.1.3 (joint strips,1507.1.1.3
/R%5.1.1.3) /R90S.1.1.3)
Polystick MU X Yes No No Yes Yes Yes Yes Yes
(joint strips,1507.1.1.3 (joint strips,1507.1.1.3
I R%5.1.1.3) /R905.1.1.3)
Polystick TU Max No Yes Yes Yes Yes
(See 5.6.1) Yes Yes No (joint strips,1507.1.1.3 (joint strips,1507.1.1.3
/R905.1.1.3) /R905.1.1.3)
Polystick TU P No Yes Yes Yes Yes
(See 5.6.1) NO NO NO (pint stops,1507.1.1.3 (pint strips,1507.1.1.3
/R%5.1.1.3) /R905.1.1.3)
Polystick TU Plus Yes Yes Yes
Yes7 Yes
(See 5.6.1) Yes Yes Yes (pint strips,1507.1.1.3 (pint strips,1507.1.1.3
/R905.1.1.3) /R905.1.13)
EPolystick XFR Yes Yes No Yes Yes Yes Yes Yes
(pint strips,1507.1.1.3 (pint strips,1507.1.3.3
/R905.1.1.3) /R905.1.1.3)
NEMO ETC,I.I.C.
Certificate oJAuthoriiotion#32455 7T"EDITION(2020)FBC NON-HVHZ EVALUATION Evaluation Report P12060.02.09-R27
Polyglass Roof Underlayments FL52S9-R31
Revision 27:09/30/2020
Page 5 of 17
ONEMOletc.
5.6.1 Adhesive-set tile is limited to use of the following underlayment/tile-adhesive combinations.
TABLE IA:ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS2
Underlayment Adhesive Florida Product Approval
Polystick TU Max or Polystick TU Plus DAP Foam"Touch'n Seal FL14506
StormBond Roof Tile Adhesive"
HydraGuard Tile Pro,Polyflex SA P,Polystick TU Max,Polystick TU P or Polystick Dupont'rile BondT'Roof Tile
TU Plus Adhesive" FL22525
Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA
APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, ICP Adhesives and Sealants FL6332
Polystick TU P or Polystick TU Plus "Polysets AH-160"
Elastoflex S6 G,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA
APP Cap Sheet(FR),Polyflex G,Polyflex SA P,Polyflex SA P FR,Polystick TU Max, ICP Adhesives and Sealants FL6276
Polystick TU P or Polystick TU Plus "Polyset®RTA-1"
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment Application ----- Substrates(designed to meet wind loads for project)
Type Primer Material(s)
HydraGuard Dual Pro, (Optional)ASTM plywood,OSB,Southern Yellow Pine or Huber Engineered
HydraGuard Tile Pro,Polystick IR- Deck/ D41 Woods"ZIP System"Panels
Xe,Polystick MTS Plus,Polystick sheathing
MU-X,Polystick TU Max, ASTM D41 structural concrete
Polystick TU P,Polystick TU Plus, self- ASTM C1289 Type II Class 1 polyisocyanurate,ASTM
adheringInsulation (Optional)ASTM
Polystick XFR,Mule-Hide SA-APP D41 or WB-3000 C1289 Type V polyisocyanurate-composite,DensDeck
Cap Sheet,Mule-Hide SA-APP Prime or SECUROCK Gypsum-Fiber Roof Board
Cap Sheet(FR),Polyflex SA P or Base Sheet N/A ASTM D226,Type II felt,Elastobase,Elastobase P or Mule-
Polyflex SA P FR Hide Nail Base
Deck ASTM D41
structural concrete
Elastoflex S6 G or Elastoflex S6 G Insulation (Optional)ASTM DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
FR hot asphalt D41
Base Sheet N/A ASTM D226,Type II felt,Elastobase,Elastobase P,Mule-
Hide Nail Base or Polyglass G2 Base
Deck ASTM D41 structural concrete
torch- Insulation (Optional)ASTM
rPolyflexr Polyflex G FR � D41 DensDeck Prime or SECUROCK Gypsum-Fiber Roof Board
applied
Base Sheet N/A Elastobase, Elastobase P,Mule-Hide Nail Base,Polyglass
G2 Base or Polyglass Base
'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC.
Certificate of Authorization#32455 7T'EDITION(2020)FBC NON-HVHZ EVALUATION Evaluation Report P12060.02.09-1127
Polyglass Roof Underlayments FLS259-R31
Revision 27:09/30/2020
Page 6 of 17
L
ONEMOletc.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings, attachment shall be in accordance with the
manufacturer's installation instructions, but—for mechanically attached underlayments or base sheets - not less than FBC
1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but—
for mechanically attached base sheets-not less than:
• FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition,Appendix A,Table 1(for Two-
Ply Asphalt Applied Hot Mop Underlayment)
or
• Section 5.8.3 herein (for other underlayment systems).
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing
for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1
margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
l Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-52.5 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,O5B sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Joints: Min.4-inch wide strips of Elastoflex SAN over all OSB joints
Base Ply: Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#2 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#3 Maximum Design Pressure=-97.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus, self-adhered and back-nailed within the selvedge-edge side laps using 12 ga. x 1'/." ring shank
nails through 32 ga.,1-5/8"diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-105 psf:
Deck: Min.1S/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus, self-adhered and back-nailed within the selvedge-edge side laps using 12 ga.x 1Y.." ring shank
nails through 32 ga., 1-5/8"diameter tin caps spaced 12-inch o.c.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-1127
Certificate of Authorization#31455 7"EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 7 of 17
NEMO I etc.
#5 Maximum Design Pressure=-135 Psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional)PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Joints: Min.4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#6 Maximum Design Pressure=-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional)Polystick MTS Pius,self-adhered.
Underlayment:HydraGuard Tile Pro, Mule-Hide SA-APP Cap Sheet, Mule-Hide SA-APP Cap Sheet (FR), Polyflex SA P, Polyflex SA P FR,
Polystick TU Max,Polystick TU P or Polystick TU Plus,self-adhered.
#7 Maximum Design Pressure=-622.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG1DO or ASTM D41
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#8 All other direct-deck,adhered underlayment systems beneath tile roof systems carry a Maximum Design Pressure of-45 psf.
5.8.3.2 Mechanically-Attached Base Sheet:
The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High
Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 design
pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Elevated pressure zones shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing
Application Standard RAS 137. Assemblies marked with an asterisk*carry the limitations set forth in Section 2.2.10.1 of FM
Loss Prevention Data Sheet 1-29(February 2020)for enhancements.
#9 Maximum Design Pressure=-30.0 psf*:
Deck: Min.15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#10 Maximum Design Pressure=-37.5 psf*:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch long x 1-Inch head diameter round metal cap nails
Spacing: 6-inch o.c,at the 3-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#11 Maximum Design Pressure=-37.5 psf*:
Deck. Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)or two(2)layers ASTM D226,Type II felt
Fasteners: 11 ga.x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt.
NEMO ETC,I.I.C. Evaluation Report P12060.02.09-R27
Certificate afAuthorization#32455 7T-EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 8 of 17
I
ONEMOletc.
#12 Maximum Design Pressure=-45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One(1)layer ASTM D226,Type 11 felt
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 2-inch wide side laps and 4-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#13 Maximum Design Pressure=-45 psf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two(2)layers ASTM D226,Type(I felt
Fasteners: 11 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 9-inch o.c.at the 2-inch wide side laps and 9-inch o.c.at two(2)equally spaced staggered center rows.
Base Ply: (Optional;for use with self-adhering underlayment only)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered or Elastoflex S6 G,applied in full mopping of hot asphalt,
#14 Maximum Design Pressure=-45 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 18-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#15 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/9"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered
#16 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in,,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt.
#17 Maximum Design Pressure=-45.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: 12 ga.annular ring shank nails with 1-5/8"diameter tin caps
Spacing: 6-inch o.c,at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#18 Maximum Design Pressure=-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
NEMO ETC,I.A.C. Evaluation Report P12060.02.09-1127
Certificate of Authorization#31455 7T'EDITION(2020)FBC NON-HVHZ EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 9 of 17
IRNEMOJetc.
#19 Maximum Design Pressure=-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#20 Maximum Design Pressure=-52.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c.at the 3-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#21 Maximum Design Pressure=-60 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: 11 ga.x 1,25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c,at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#22 Maximum Design Pressure=-60 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip with OMG Flat Bottom Metal Plates
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#23 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FIR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#24 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#25 Maximum Design Pressure=-60.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Poiyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8-inch o.c.at the 3-inch wide side laps and 8-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
NEMO ETC,LLC. Evaluation Report P12060.02.09-R27
CerhJrtate of Authorization#31455 7"EDITION(2020)FBC NON-HVH2 EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 10 of 17
i
OONEMOletc.
#26 Maximum Design Pressure=-67.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: 12 ga.x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c.at the 4-inch wide side laps and 8-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex 56 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#27 Maximum Design Pressure=-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: (Optional)PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FIR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#28 Maximum Design Pressure=-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt.
#29 Maximum Design Pressure=-67.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to
the width direction of the sheet.
Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#30 Maximum Design Pressure=-75 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat
Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c,at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#31 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#32 Maximum Design Pressure=-90 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 5-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
NEMO ETC,LLC. Evaluation Report P12060.02.09-1127
Certificate of Authorization#.31a55 7'"EDITION(2020)F8C NON.HVHZ EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 11 of 17
i
ONEMOletc.
#33 Maximum Design Pressure=-90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#34 Maximum Design Pressure=-90 pst
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment)
Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat
Bottom Plates JAccuTrac►,Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied.
#35 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate, parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#36 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 In.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt.
i #37 Maximum Design Pressure=-90.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction,
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#38 Maximum Design Pressure=-97.5 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c.at the 4-inch wide side laps and 4-inch o.c.at four(4)equally spaced staggered center rows.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
NEMO ETC,LLC. Evaluation Report P32060.02.09-R27
Certificate of Authorization#32455 7`"EDITION(2020)FBC NON•HVH2 EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 12 of 17
1
ONEMOletc.
#39 Maximum Design Pressure=-97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#40 Maximum Design Pressure=-97,5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows_
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#41 Maximum Design Pressure=-97.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#42 Maximum Design Pressure=-105 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#43 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.419 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Primer: P6100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#44 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment:Elastoflex S6 G,applied in full mopping of hot asphalt.
NENIO ETC,I.I.C.
Evaluation Report P12060.02.09-1127
Certificate of Authorization#32455 7"EDITION(2020)FBC NON-HVH2 EVALUATION FL5259-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 13 of 17
ONEMOletc.
#45 Maximum Design Pressure=-105.0 psf:
Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180'into the holes of the plate,parallel to
the width-direction of the sheet
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
#46 Maximum Design Pressure=-112.5 psf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: 11 ga.x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer at all tin-caps
Base Ply: Polystick MTS Plus,self-adhered
Underlayment: Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#47 Maximum Design Pressure=-120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap)
Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c,at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied.
#48 Maximum Design Pressure=-120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface)
Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates
Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at five(5)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#49 Maximum Design Pressure=-127.5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c,at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Primer: PG100 or ASTM D41 primer applied to stress plates.
Base Ply: (Optional)Polystick MTS Plus,self-adhered.
Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick
TU P or Polystick TU Plus,self-adhered.
#50 Maximum Design Pressure=-127 5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase(sand top surface)
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Elastoflex S6 G,applied in full mopping of hot asphalt.
#51 Maximum Design Pressure=-127 5 psf:
Deck: APA rated, 19/32 CAT, 0.578 in., Exposure 1, OSB sheathing to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Elastobase or Polyglass Base
Fasteners: TRUFAST Versa-Fast Fasteners&Plates with one(1)screw per plate,in the center hole.
Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows.
Underlayment: Polyflex G,torch-applied.
NEMO ETC,LLC. Evaluation Report P12060.02.09-R27
Certificate of Authon2ation#32455 7'"EDITION(2020)FBC NON-HVH2 EVALUATION FL5259-1131
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 14 of 17
N
5.9 Exposure Limitations: MEMO I etc.
TABLE 3: EXPOSURE LIMITATIONS
Underlayment Prepared Roof Cover Maximum
Installation Type Exposure(days)
Elastobase,Elastobase P,Polyglass G2 Base or Polyglass Base Mechanically attached 30
Polystick IR-Xe or Polystick MU-X Mechanically attached 90
HydraGuard Dual Pro,HydraGuard Tile Pro,Polystick MTS Plus,Polystick TU Max,Polystick
TU P,Polystick TU Plus or Polystick XFR Any type(per Table 1) 180
Elastoflex S6 G,Elastoflex S6 G FR,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Adhesive-set tile roof system 180
Sheet P I o ex(FR),Polyflex G Polyflex G FR,Polyflex SA P or Polyflex SA P FR
Mechanically attached UNLIMITED
5.10 Tile Slip
page e Limitations:When loading— a ding roof tiles on the underlayment in direct-deck the roof assemblies,the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRER-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Staging Slope
Elastoflex 56 G or S6 G FR Flat or Lugged 6-tile stack(4 over 2) Prohibited without battens
HydraGuard Tile Pro Flat or Lugged 6-tile stack(4 over 2) 7:12
Polyflex G or G FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polyflex SA P or SA P FR Flat or Lugged 6-tile stack(4 over 2) 4:12
Polystick MTS Plus Flat 6-tile stack(4 over 2) 5:12
Lugged gg 6-tile
t e stack 4 over 2
( ) 4:12
Flat 6-tile stack(4 over 2)or 10-tile stack 7:12
PolystLTU Lugged 6-tile stack(4 over 2) 7:12
Lugged 10-tile stack 6:12
Polystick TU P Flat or Lugged 6-tile stack(4 over 2) 7:12
Polystick TU Plus Flat or Lugged 6-tile stack(4 over 2) 7:12
Flat or Lugged 10-tile stack 6:12
Polystick XFR Flat or Lugged Prohibited without battens Prohibited without battens
NEMO ETC,I.I.C.
Certificate of Authorization Y32455 7"EDITION(2020)FBC NON•HVH2 EVALUATION Evaluation Report P12060.02.09-1127
Polyglass Roof Underlayments FLS259-1131
Revision 27:09/30/2020
Page 15 of 17
I
ONEMOletc.
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation instructions subject to the
Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application,and prime the substrate(if applicable).
6.3 Elastobase,Elastobase P or Mule-Hide Nail Base:
6.3.1 Non-Tile Applications
Shall be installed in compliance with requirements for an approved mechanically attached underlayment (ASTM D226, Type
II) in FBC Table 1507.1.1.1 or FBC Residential Table R905.1.1.1 for the type of prepared roof covering to be installed,and the
manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions.
Elastobase, Elastobase P or Mule-Hide Nail Base may be covered with a layer of Polystick IR-Xe, Polystick MTS Plus, Polystick
MU-X,Polystick TU Max, Polystick TU P,Polystick TU Plus,Polystick XFR,Polyflex SAP,Polyflex SA P FR,Mule-Hide SA-APP Cap
Sheet or SA-APP Cap Sheet(FR), self-adhered, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G
FR,torch applied. Roof cover limitations are those are those associated with the top-layer underlayment,as set forth in Table
1.
6.3.2 Tile Applications
6.3.2.1 Elastobase(poly-film top), Elastobase P(poly-film top) and Mule-Hide Nail Base are limited to use as a mechanically attached
base sheet in the"TWO-PLY SYSTEM"from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth
Edition,followed by Polystick MTS Plus,Polystick TU Max,Polystick TU P,Polystick TU Plus,Polystick XFR,Polyflex SAP,Polyflex
SA P FR,Mule-Hide SA-APP Cap Sheet or SA-APP Cap Sheet(FR),self-adhered or Polyflex G or Polyflex G FR,torch-applied. Tile
roof installation method is limited by the selected Cap Sheet, as set forth in Table 1. Refer to Section 5.8.3.2 herein for
attachment requirements.
6.3.2.2 Elastobase(sanded-top)and Elastobase P(sanded-top)e are limited to use as a mechanically attached base sheet in the"TWO-
PLY SYSTEM" from FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, followed by
Elastoflex S6 G, Elastoflex 56 G FR or an FBC Approved Mineral Surfaced Cap Sheet(ASTM D6380),asphalt-applied or Polyflex
G or Polyflex G FR,torch-applied. Tile roof installation method is limited by the selected Cap Sheet, as set forth in Table 1.
• When Elastobase(sanded-top)or Elastobase P(sanded-top) is followed by asphalt-applied Elastoflex S6 G, Elastoflex 56
G FR or FBC Approved Mineral Surfaced Cap Sheet(ASTM D6380), refer to FRSA/TRI, Sixth Edition,Appendix A,Table 1
or Section 5.8.3.2 herein for attachment requirements.
• When Elastobase(sanded-top)or Elastobase P(sanded-top)is followed by torch-applied Polyflex G or Polyflex G FR,refer
to Section 5.8.3.2 herein for attachment requirements.
6.4 HydraGuard Dual Pro,HydraGuard Tile Pro,Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR), Polyflex SA P,
Polyflex SA P FR,Polystick IR-Xe,Polystick MTS Plus,Polystick MU-X, Polystick TU Max,Polystick TU P, Polystick TU Plus or
Polystick XFR:
6.4.1 General All seal-lap seams (selvage laps)P ) must be firmly rolled with a
in accordance with Polyglass requirements to ensure full 'f '
contact and adhesion. For HydraGuard Dual Pro and
HydraGuard Tile Pro, align the edge of the top sheet to the
end of the glue pattern (the sheet will overlap the fabric).
T
View of Ovelap Seam of HydraGuard Dual Pro and HydraGuard Tile Pro
NEMO ETC,I.I.C.
Cerrijicare of Authonzat'on#32455 7"'EDITION(2020)FBC NON•HVHZ EVALUATION Evaluation Report P12060.02.09.R27
Polyglass Roof Underlayments F15259-R31
Revision 27:09/30/2020
Page 16 of 17
I
ONEMOjetc.
6.4.2 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment (ASTM D1970) in FBC
1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed,
and the manufacturer's installation instructions.
When installed over a mechanically attached base sheet of FBC Approved ASTM D226,Type II felt, Elastobase, Elastobase P or
Mule-Hide Nail Base,the base sheet shall be fastened in accordance with FBC 1507.1.1 or R905.1.1.
i
6.4.3 Tile Applications(excludes HydraGuard Dual Pro, Polystick IR Xe and Polystick MU-X):
Shall be installed in compliance with the requirements for Self-Adhered Membrane set forth in FRSA/TRI Florida High Wind
Concrete and Clay Roof Tile Installation Manual,Sixth Edition and the manufacturer's installation instructions.
3 Refer to Section 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
6.4.4 Multi-Ply Underlayment Systems:
Polystick MTS Plus or Polystick XFR followed by HydraGuard Tile Pro,Polyflex SA P,Polystick MTS Plus,Polystick MU-X,Polystick
TU Max, Polystick TU P, Polystick TU Plus or Polystick XFR is allowable for use under mechanically attached prepared roof
systems. Limits of use are those associated with the top-layer material. This is not a requirement, but is allowable if a 2-ply
underlayment system is desired.
Polystick MTS Pius followed by HydraGuard Tile Pro, Polyflex SA P, Polystick TU Max, Polystick TU P or Polystick TU Plus is
allowable for use under adhesive-set tile systems. Limits of use are those associated with the top-layer material. This is not a
requirement,but is allowable if a 2-ply underlayment system is desired.
6.5 Elastoflex S6 G or Elastoflex S6 G FR:
6.5.1 Shall be installed in compliance with requirements as an alternate to the "Hot Asphalt Applied Cap Sheet" in the "Two Ply
System" in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the
manufacturer's installation instructions.
Refer to Section 5.8.2 and 5.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
i
6.6.. Polyflex G or Polyflex G FR.
1 6.6.1 Shall be installed in compliance with requirements as an alternate to the"Heat Applied Cap Sheet" in the"Two Ply System"in
the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's
{ installation instructions.
Refer to Section S.8.3 herein for attachment limitations.
Refer to Table 4 herein for tile staging limitations.
REQUIREMENTS:BUILDING PERMIT
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
8. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements. Refer to Section
4 herein for products and production locations having met codified material standards.
QUALITY9.
UL LLC—QUA9625; (414)248-6409; Karen.buchmann@ui.com
-END OF EVALUATION REPORT-
NEMO ETC,U.C.
Evaluation Report P12060.02.09.R27
Certificate ojAutho.izat,on a32455 7"'EDITION(2020)FBC NON-HVHZ EVALUATION
f15254-R31
Polyglass Roof Underlayments Revision 27:09/30/2020
Page 17 of 17