Loading...
HomeMy WebLinkAboutBuilding permit appAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: ____________________ Permit Number: _____________________ Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial __________ Residential ___________ 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 CBDG Funding _________ PERMIT APPLICATION FOR: PROPOSED IMPROVEMENT LOCATION: Address: __________________________________________________________________________________________ Property Tax ID #: _________________________________________________________________ Lot No.__________ Site Plan Name: __________________________________________________________________ Block No. _______ Project Name: ______________________________________________________________________________________ DETAILED DESCRIPTION OF WORK: _________________________________________________________________________________________________ __________________________________________________________________________________________________ __________________________________________________________________________________________________ New Electrical Meter __________ Second Electrical Meter_______________ (Affidavit required) CONSTRUCTION INFORMATION: Additional work to be performed under this permit – check all that apply: __Mechanical __ Gas Tank __ Gas Piping __ Shutters ___ Windows/Doors ___ Pond __ Electric __ Plumbing __ Sprinklers __ Generator ___ Roof __________ Pitch Total Sq. Ft of Construction: ___________________ Sq. Ft. of First Floor: _________________________ Cost of Construction: $ _____________________ Utilities: __ Sewer __ Septic Building Height: __________ OWNER/LESSEE: CONTRACTOR: Name__________________________________________ Address: ________________________________________ City: _________________________________ State: ___ Zip Code: ______________ Fax: ____________________ Phone No.______________________________________ E- Mail:________________________________________ Fill in fee simple Title Holder on next page (if different from the Owner listed above) Name: ________________________________________ Company: _____________________________________ Address: _______________________________________ City: ______________________________ State: ____ Zip Code: ________________ Fax: __________________ Phone No______________________________________ E-Mail_________________________________________ State or County License___________________________ If value of construction is 2500 or more, a RECORDED Notice of Commencement is required. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. X SOUTHERN SHORES ELECTRIC COMPANY 9303 S.INDIAN RIVER DRIVE ELECTRICAL SERVICE UPGRADE 1500 11-12-21 3519-414-0002-000-7 X ELECTRICAL SERVICE UPGRADE TO 200AMPERES, 200AMP MAIN BREAKERMETER MAIN COMBO, 150AMP RATED EXISTING PANEL ON INTERIOR 150AMP MAIN BREAKER. **OVER HEAD TO UNDERGROUND CONVERSION** SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: ___ Not Applicable Name: _____________________________________ Address: __________________________________ City: __________________________ State: _____ Zip: ___________ Phone______________________ MORTGAGE COMPANY: ___ Not Applicable Name: ____________________________________ Address: ___________________________________ City: ____________________________State: _____ Zip: __________ Phone: ______________________ FEE SIMPLE TITLE HOLDER: ___ Not Applicable Name: _____________________________________ Address: ___________________________________ City: _______________________________________ Zip: ___________ Phone: ______________________ BONDING COMPANY: ___Not Applicable Name: ____________________________________ Address: ______________________________________ City: __________________________________________ Zip: ___________ Phone: _________________________ OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to th e issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structur e which conflicts with any applicable Homeowners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Homeowners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property. A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording your Notice of Commencement. ___________________________________________ Signature of Owner/ Lessee/Contractor as Agent for Owner STATE OF FLORIDA COUNTY OF_________________________________ Sworn to (or affirmed) and subscribed before me of ____ Physical Presence or _____ Online Notariz ation this ____ day of _________________, 20___ by Name of person making statement. Personally Known _______ OR Produced Identification ______ Type of Identification Produced__________________________ (Signature of Notary Public- State of Florida) Commission No. ______________ (Seal) REVIEWS FRONT COUNTER ZONING REVIEW SUPERVISOR REVIEW PLANS REVIEW VEGETATION REVIEW SEA TURTLE REVIEW MANGROVE REVIEW DATE RECEIVED DATE COMPLETED Rev 5/20/21 Underground Overhead 1.Size Service: 2.Conductor Size:CU ALUM 3. a. Meter Main: b.Meter Can Only: M Grounding Electrode Conductor Size #6 #4 #2 Other CONSTRUCTION TYPE: Residential Mobile Home New Installation Old Installation Dual Electrodes or Test Required **RMC W/BOND BUSHING #6 GREEN EQUPMENT GROUNDING CONDUCTOR WILL BE RAN TO EXISTING PANEL BOARD. TERMINAL WILL BE INSTALLED IN EXISTING PANEL, ALL NEUTRIALS AND EQUPMENT GROUNDS WILL BE ISOLATED*BONDING SCREW OR BONDING STRAP WILL BE REMOVED. 150A RATED PANEL 150A MCB EXISTING 200AMAIN BREAKER 200AMPS 2/0 2" PVC CONDUIT SCH 40UNDERGROUND-SCH 80 EMERGING FROM GRADE Residential Optional Calculation 9/25/1997 OPTIONAL by: John Sokolik Version 2011 L STEP 1 Article 220.82 (B) (1),(2)SOUTHERN SHORES ELECTRIC CO standard 2301 General Lighting load 6,903 VA 1331 NE SUNRISE TER ahu 2 Small Appliance 3,000 VA JENSEN BEACH, FL, 34957 cool 1 Laundry circuit 1,500 VA (772)-353-0072 Gen.Lgt, Sm App.& Laun. Load 11,403 VA 11/12/2021 18:41 ahu hp STEP 2 Article 220.82 (C)General lighting, Sm. Appl. & Laundry 11,403 VA A/C Condenser & Fixed Electric Space Heating Total 1 ### 7,130 VA AHU 1 11,600 VA Heating Load 8,100 VA ### VA AHU 2 VA CU Load 8,730 VA ### VA AHU 3 VA ### VA AHU 4 VA Electric Space Heat @ 65% <4, 40% >3, vs. A/C @ 100%8,730 VA ### VA AHU 5 VA ### STEP 3 Article 220.82 (B) (3) Appliance Demand Load 15,944 VA ### 1 Water Heater 4,500 VA ### 1 Refrigerator 1,400 VA Dryer Demand Load 7,200 VA 0 Freezer VA DEM FACTOR 1 Dishwasher 1,400 VA Range Demand Load 8,000 VA ### 1 Disposal 690 VA <4 1 R / Hood 400 VA Service Demand 31,749 VA >3 1 Microwave 1,700 VA 0 Microwave VA Demand Load 132 A 0 Mini Refrig VA 0 Wine Clr VA Neutral Demand 87 A 0 Insta Hot VA 0 Ironing Center VA Min.Service Req.150 A Jacuzzi Tub VA Sprinkler Pump 1,127 VA Min. Feeder size 1 Well Pump 1,127 VA Min. Neutral size 3 Fountain Pump VA Eq. Grding Cond.6 Elevator VA Copper Pool Equip. Panel VA Apply Demand 3600 POOL PUMP 3,600 VA No Demand VA No Demand Total Appliance Load 15,944 VA STEP 4 Article 220.82 (B) (3) Electric Clothes Dryers 7,200 VA STEP 5 Article 220.82 (B) (3) Electric Ranges 8,000 W Col C demand 8000 Cooktop Col B demand Cooktop Col B demand Oven(s) Col B demand Oven(s) Col B demand Number of appliances 0 Dem. Factor Cooktop & Oven Demand Load >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< Pool Panel Feeder Calculation (See Note)A B N Continuous Non-continuous Continuous Motors 0 . . . . . .0 0 0 Motors Motors Non-continuous 0 . . . . . .0 0 0 240v 240v Spa heater 11 kVA . . . . . .0 0 240v 240v Pool heater 3.5 ton . . . . . .0 0 240v 240v Pool heater 5 ton . . . . . .0 0 240v 240v Pool Light 0 . . . . . .0 0 0 240v 240v Blower 2333 0 240v 0 0 0 other load 0 240v 0 0 0 0.0 Motor Neutral Load other load 0 240v 0 0 0 Min.Copper Pool Feeder AWG A A A Max.Unbalanced Neutral Load Minimum Panel Rating A Phase Amperes Neut. load QTY or Number of appliances jmp1jds@comcast.net Check Box for Gas Range