Loading...
HomeMy WebLinkAboutEngineering i ,,�s S.UMM IT D.E51"GhI & FORE'N5ICS1.,. INC. lie copy November 22, 2021 ICE IIE VED FOR CO COMPiLIAI�ICE RE: Re: Reroofing S'�'. LN '� I E �;OWN Y 415 West Weatherbee Road Fort Pierce,Florida OCC U f Attention: Reviewer, The subject commercial building will be reroofed. The following design lo:1ads according to the 2020 Florida Building Code apply. Wind speed, 3 second gust,ultimate: 160 mph Mean roof height: 10 feet Exposure: B Enclosed Building Internal Pressure Coefficients: +/-0.18 Building Risk Category: II The following calculated design wind uplift pressures apply based on a 10 square foot tributary area. Zone F: -44 psf Zone 1: -44 psf Zone 2: -58.1 psf Zone 3: -79.1 psf The following roof system will be utilized. Type: Modified Bitumen fully adhered base and cap sheet roof system Manufacturer: Polyglass USA Florida Product Approval: FL1654.1 System No.: W-210 Manufacturer Design Pressure: -97.5 psf Deck type: 15/32"plywood Low slope system Base Sheet: 1 ply POL Elastoflex SAU Base polyglass self adhered SBS Cap Sheet: 1 ply POL Polyflex SAP G White Polyglass self adheri d APP Insulation above decking: None Based on the above the criteria,the proposed roofing will satisfy the uplift pressures calculated and will satisfy the 2020 Florida Building Code, 7th Edition. If you should have any questions, please call me at 772-285-0572. Respectfully Submitted, Brian J. Maskol, P.E. �1'` �3n `�/ Summit Design&Forensics, Inc. a��'�•'������s '� State of Florida _ A License No. 66080 /llflll`t\i i it I