Loading...
HomeMy WebLinkAbout5440 slash pine tdl faAPPLICATION #:AP16'18024 STATE OF FLORIDA PERMIT #: 56-SF-2227881 DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:F11750122 .y CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:02/04/2021 FEE PAID:660.00 RECEIPT #:56-PID-4869526 APPLICANT: Brandon Comeau AGENT: Dave Golden (Dave Golden Homes) PROPERTY ADDRESS: 5440 Slash Pine Trl Fort Pierce, FL 34951 LOT: BLOCK: SUBDIVISION: ID# : 1407-313-0025-000-4 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 1090.00 [21 [ ] [27] SURFACE WATER FT [ ] [02] TANK MATERIAL Polypropylene [ ] [281 DITCHES 76 FT [ ] [031 OUTLET DEVICE ( ] [291 PRIVATE WELLS 90 FT [ ] [04] MULTI -CHAMBERED [L2�j N ] ( ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER Polylok PL-68 [ ] [311 IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-143-11DC4 2. ( ] [321 POTABLE WATER 76 FT ( ] [07] WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 6 FT [ ] [08] LEVEL ( ] [341 PROPERTY LINES 25 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1] 6 [2] SQFT ( ] (361 DRAINFIELD COVER [ ] [11] DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS ( ] [121 NUMBER OF DRAINLINES 1. 679.0 2. [ ] [381 SLOPES [ ] [131 DRAINLINE SEPARATION ( ] [39] STABILIZATION 12/09/2021 [ ] (141 DRAINLINE SLOPE ( ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 9.00 [ ] [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS [ ] [42] ALARMS [ ] [191 AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ 1 [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] (461 FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [471 CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [231 FILL TEXTURE [ ] (48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] (251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. 42 / ^`Environ St. Lucie CHD DATE: 10/15/2021 CONSTRUCTION [ APPROVED DISAPPROVED ) ' ental Specialist III Elrthn.j Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ / St. Lucie CHD DATE: 12/09/2021 AppROVED DISAPPROVED ]: Environmental Specialist III Br' n J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1618024 EID2227881 ,.�. STATE OF FLORIDA < DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM '.y CONSTRUCTION INSPECTION AND FINAL APPROVAL WE Y4w Violation Number Comment Comments APPLICATION # : AP 1618024 PERMIT #:56-SF-2227881 DOCUMENT # : FI 1750122 DATE PAID:02/04/2021 FEE PAID:660.00 RECEIPT #:56-PID-4869526 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 )pd. Vew ST, filter, and 6x10 long BED DF installed. No violations, system ok to cover, contractor notified onsite. Needs final nspection for mound system and final site grading. =inal system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1618024 EID2227881