HomeMy WebLinkAbout7827 sabal lake dr faSTATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
�. wes .
APPLICANT: Erik Melville
AGENT: DiFrancesco Construction, Inc
PROPERTY ADDRESS: 7827 Saba] Lake Dr Port Saint Lucie, FL 34986
APPLICATION #:AP1551345
PERMIT #:56-SF-2137387
DOCUMENT #: FI 1750121
DATE PAID:02/11/2021
FEE PAID:25.00
RECEIPT #:56-PID-4884031
LOT: 30
BLOCK:
SUBDIVISION:
Sabal Creek I ID#: 3321-501-0030-000-2
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE [11 1537.00 [2] 1090.00 (
] [271
SURFACE WATER 100
FT
[ ] [021
TANK MATERIAL Polypropylene [
] [281
DITCHES
FT
[ ] [031
OUTLET DEVICE [
] (291
PRIVATE WELLS 100
FT
[ ] [041
MULTI -CHAMBERED [LZJ N ] [
] [301
PUBLIC WELLS
FT
[ ] [051
OUTLET FILTER Polylok PL-68 [
] [31]
IRRIGATION WELLS
FT
[ ] [061
LEGEND 1. 70-143-16DC4 2. 70-143-11SC4 [
] [32]
POTABLE WATER 84
FT
[ ] (07]
WATERTIGHT [
] [33]
BUILDING FOUNDATIONS 7
FT
[ ] [08]
LEVEL [
] [341
PROPERTY LINES 40
FT
[ ] [091
DEPTH TO LID [
] [351
OTHER
FT
DRAINFIELD INSTALLATION
FILLED / MOUND SYSTEM
[ ] [101
AREA [11 871.64 [21 SQFT [
] [36]
DRAINFIELD COVER
[ ] (11)
DISTRIBUTION BOX HEADER X [
] [37]
SHOULDERS
[ ] [12]
NUMBER OF DRAINLINES 1. 7.00 2. [
] [381
SLOPES
[ ] [131
DRAINLINE SEPARATION [
] [391
STABILIZATION 12/09/2021
[ ] [141
DRAINLINE SLOPE
[ ] [151
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [161
ELEVATION [ ABOVE / BELOW ]BM 4.00 [
] [401
UNOBSTRUCTED AREA
[ ] [171
SYSTEM LOCATION [
] (41]
STORMWATER RUNOFF
[ ] [18]
DOSING PUMPS 1.00 (
] [421
ALARMS
[ ] [191
AGGREGATE SIZE [
] [431
MAINTENANCE AGREEMENT
[ ] [201
AGGREGATE EXCESSIVE FINES [
] (44]
BUILDING AREA
[ ] [21]
AGGREGATE DEPTH (
] [45]
LOCATION CONFORMS WITH SITE PLAN
FILL
/ EXCAVATION MATERIAL [
] [461
FINAL SITE GRADING
[ ] [22]
FILL AMOUNT [
] [47]
CONTRACTOR MICHAEL W STUHR (ASHTO
[ ] [231
FILL TEXTURE [
] [481
OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ] [241
EXCAVATION DEPTH
ABANDONMENT
[ ] [251
AREA REPLACED [
] [491
TANK PUMPED
[ ] [261
REPLACEMENT MATERIAL, [
] (50]
TANK CRUSHED & FILLED
Comments: Comments are on page 2.
CONSTRUCTION I APPROVED / St. Lucie CHD
DISAPPROVED Environ aI B l Specialist IIJ Ingram (ENVIRONMENTAL HEALTH)
FINAL SYSTEM [ APPROVED / DISAPPROVED ]: l St. Lucie CHD
Environmental Specialist III ian J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, PAC
DATE: 10/08/2021
DATE: 12/09/2021
Page 2 of 3
EH Database v 1.0.1 AP1551345 EID2137387
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
Comments
APPLICATION # : AP 1551345
PERMIT #:56-SF-2137387
DOCUMENT # : FI 1750121
DATE PAID:02/11/2021
FEE PAID:25.00
RECEIPT #:56-PID-4884031
The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 520
gpd.
New ST, filter, DT, liberty 1/3 hp pump, and 7x11 long BED DF. No violations, system ok to cover, contractor notified by phone.
Needs final inspection for mound system, alarm check, and final site grading.
Final system approved. Contractor and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1551345 EID2137387