Loading...
HomeMy WebLinkAboutENERGY LOT 24FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-LELIA Builder Name: KHOVNANAIN HOMES Street: 5130 ARMINA PLACE Permit Office: City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: LELIA MODEL LOT 24 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 10. Wall Type�1844.9 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1508.90 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11.0 336.00 ft2 c. NIA R_ ft2 4. Number of Bedrooms 4 d. NIA R= ftZ 5. Is this a worst case? No 11. Ceiling Types (1917.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1917.00 ft2 6. Conditioned floor area above grade (ft2) 1917 b. NIA R= ft2 Conditioned floor area below grade (ftZ) 0 c. NIA R= ft2 7. Windows(201.8 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.28 159.83 ft2 a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY 6 250 SHGC; SHGC=0.30 b. U-Factor: Dbl, U=0.55 42.00 ft2 13. Cooling systems kBtulhr Efficiency SHGC: SHGC=0.34 a. Central Unit 35.2 SEERA6.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 1.570 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.308 a. Electric Strip Heat 32.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1917.1 sqft-) Insulation Area EF: 0.950 a. Slab -On -Grade Edge Insulation R=0.0 1917.10 ft2 b. Conservation features b. N/A R= ft2 None c. NIA R= ft2 16. Credits Pstat Total Proposed Modified Loads: 59.66 Glass/Floor Area: 0.105 PASS Total Baseline Loads: 61.14 1 hereby certify that the plans and spec" i ations covered by Review of the plans and �V'KlaE 3Z6, this calculation are in compliance wit Florida Energy specifications covered by this M Code. calculation indicates compliance �,,f�`�'` `.�,•• with the Florida Energy Code. .r+rr,f k :" `,.d ••14 PREPARED BY: Before construction is completed W DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. p,B vwvt OWNERIAGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 6/10/2021 12:07 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: KHOV-LELIA Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area; 1917 Lot # Owner Name: LELIA MODEL LOT 24 @ WA Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: KHOVNANAIN HOMES Rotate Angle: 0 Street: 5130 ARM INA PLACE Permit Office: Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Detached FL, NewlExisting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1917 16614.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 EXT STE LIV PLUS 199 1765.1 No 0 4 1 No Yes Yes 2 WIC STE PLS BED 25 220 No 0 1 No Yes Yes 3 EX STE PLUS BED 132 1161.6 No 0 1 No Yes Yes 4 EX STE BATH 54 475.2 No 0 1 No Yes Yes 5 FOYER 81 712.8 No 0 1 No Yes Yes 6 HALL BATH 54 475.2 No 0 1 No Yes Yes 7 LAUNDRY 77 677.6 No 0 1 No Yes Yes 8 BED 3 126 1108.8 No 1 1 No Yes Yes 9 BED 2 126 1109 No 1 1 No Yes Yes 10 KIT GREAT RM DI 672 5644.8 No 0 1 No Yes Yes 11 M BATH 95 836 No 0 1 No Yes Yes 12 MASTER SUITE 210 1848 No 2 1 No Yes Yes 13 MASTER WIC 66 580.8 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge lnsulatio EXT STE LIV PL 46 ft 0 1993 ft2 ---- 0 1 0 2 Slab -On -Grade Edge lnsulatio WIC STE PLS BE 4.5 ft 0 25 ft2 ---- 0 1 0 3 S lab -On -Grade Edge lnsulatio EX STE PLUS B 8.5 ft 0 132 ft2 -__- 0 1 0 4 Slab -On -Grade Edge lnsulatio EX STE BATH 1 ft 0 54 ft2 ____ 1 0 0 6/10/2021 12:07 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6 I-URM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5SIab-On-Grade Edge Insulatio FOYER 19 ft 0 81,3 ft2 ---- 1 0 0 6 Slab -On -Grade Edge Insulatio HALL BATH 1 ft 0 54 ft2 --_- 1 0 0 7 Slab -On -Grade Edge Insulatio LAUNDRY 7.5 ft 0 77 ft2 __-- 1 0 0 8 Slab -On -Grade Edge Insulatio BED 3 22.5 ft 0 126 ft2 -__- 0 1 0 9 Slab -On -Grade Edge Insulatio BED 2 12.5 ft 0 126 ft2 ___- 0 1 0 10SIab-On-Grade Edge Insuiatio KIT GREAT RM 43.5 ft 0 672 ft2 ---- 1 0 0 11SIab-On-Grade Edge Insulatio M BATH 9 ft 0 94.5 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio MASTER SUITE 28 ft 0 210 ft2 ---- 0 1 0 13SIab-On-Grade Edge Insulatio MASTER WIC 6 ft 0 66 ft2 ____ 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2076 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1917 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) EXT STE LIV PL 30 Blown 199 ft2 0.1 Wood 2 Under Attic (Vented) WIC STE PLS BE 30 Blown 25 ft2 0.1 Wood 3 Under Attic (Vented) EX STE PLUS B 30 Blown 132 ft2 0.1 Wood 4 Under Attic (Vented) EX STE BATH 30 Blown 54 ft2 0.1 Wood 5 Under Attic (Vented) FOYER 30 Blown 81 ft2 0.1 Wood 6 Under Attic (Vented) HALL BATH 30 Blown 54 ft2 0.1 Wood 7 Under Attic (Vented) LAUNDRY 30 Blown 77 ft2 0.1 Wood 8 Under Attic (Vented) BED 3 30 Blown 126 ft2 0.1 Wood 9 Under Attic (Vented) BEd 2 30 Blown 126 ft2 0.1 Wood 10 Under Attic (Vented) KIT GREAT RM 30 Blown 672 ftz 0.1 Wood 11 Under Attic (Vented) M BATH 30 Blown 95 ft2 0.1 Wood 12 Under Attic (Vented) MASTER SUITE 30 Blown 210 ft2 0.1 Wood 13 Under Attic (Vented) MASTER WIC 30 Blown 66 ft2 0.1 Wood 6/10/2021 12:07 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent �qpeSpace Cavity Width Height Sheathing Framing Solar Below 0 1 SE Exterior Concrete Block - Int Ins6XT STE LIV 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0 2 SW Exterior Concrete Block - Int InsEXT STE LIV 4.1 15 4 10 0 153.3 ft2 0 0 0.5 0 3 SW Exterior Concrete Block - Ink Ins1flX STE PLU 4.1 7 8 10 0 76.7 ft2 0 0 0.5 0 4 SE Exterior Concrete Block - Int InsuI FOYER 4.1 6 4 9 4 59.1 ft2 0 0 0.5 0 5 SW Exterior Concrete Block - Int Insul FOYER 4.1 11 4 10 0 113.3 ft2 0 0 0.5 0 6 NE Exterior Concrete Block - Int Insul BED 3 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0 7 NE Exterior Concrete Block- Int Insul BED 2 4.1 11 7 9 4 108.1 ft2 0 0 0.5 0 8 SW Exterior Concrete Black - Int InsKIT GREAT 4.1 25 2 10 0 251.7 ft2 0 0 0.5 0 9 NW Exterior Concrete Block - Int InsKIT GREAT 4.1 15 1 9 4 140.8 ft2 0 0 0.5 0 10 NE Exterior Concrete Block - Int Insul M BATH 4.1 8 9 9 4 81.7 ft2 0 0 0.5 0 11 NE Exterior Concrete Block - Int InsMASTER SUI 4.1 14 1 9 4 131.4 ft2 0 0 0.5 0 12 NW Exterior Concrete Block - Int 1nsMASTER SUI 4.1 13 1 9 4 122.1 ft2 0 0 0.5 0 13 NW Exterior Concrete Block - Int InSLUASTER WI 4.1 5 10 9 4 54.4 ft2 0 0 0.5 0 14 NW Garage Frame - Wood KIT GREAT 11 36 0 9 4 336.0 ft-' 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SW Insulated EXT STE LIV None .39 3 2 6 8 21,1 ft2 2 SW Insulated EXT STE LIV None .39 3 2 6 8 21.1 ft2 3 NW Wood KIT GREAT None .39 3 2 6 8 21.1 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 SE 1 Metal Double (Tinted) Yes 0.28 0.3 N 22.9 ft2 1 It 0 in 1 ft 0 in None None 2 SW 3 Metal Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 6 ft 0 in 1 ft 0 in None None 3 SW 5 Metal Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 4 NE 6 Metal Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft0 in None None 5 NE 7 Metal Double (Tinted) Yes 0.28 0.3 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 6 SW 8 Metal Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft 0 in 1 ft 0 in None None 7 NW 9 Metal Double (Tinted) Yes 0.28 0.3 N 23.0 ft2 1 ft 0 in 1 ft 0 in None None 8 NW 9 Metal Double (Tinted) Yes 0.55 0.34 N 42.0 ft2 1 ft 0 in 1 ft 0 in None None 9 NW 12 Metal Double (Tinted) Yes 0.28 0.3 N 22.9 ft2 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg, Wall Height Exposed Wall Insulation 1 380 ft2 380 ft2 64 ft 8 ft 1 6/10/2021 12:07 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 # Scope Method 1 Wholehouse Proposed ACH(50) # System Type 1 Electric Strip Heat! # System Typ( 1 Central Unit/ INPUT SUMMARY CHECKLIST REPORT INFILTRATION SLA CFM 50 ELA EgLA ACH ACH 50 .000385 1938A 106.35 199.65 .1304 7 HEATING SYSTEM Subtype Speed Efficiency Capacity Block Ducts None COP:1 32 kBtulhr 1 sys#1 COOLING SYSTEM # System Type SubT 1 Electric None FSEC Cert # Company Name None None Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts Split Singl SEER: 16 35.2 kBtulhr cfm 0.81 1 sys#1 HOT WATER SYSTEM Location EF Cap Use SetPnt Conservation Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM Collector Storage System Model # Collector Model # Area Volume FEF ft2 DUCTS / ---- Supply ---- ---- Return ---- Air CFM 25 CFM25 HVAC # �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft2 LAUNDRY 1 ft2 Default Leakage LAUNDRY (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceding Fans: Cooling Heating [ ]] Jan Feb [7C] Jan Feb Mar Mar ki Apr Ma Apr f I May Jun X Jul Jun Jul rj AuSe rj Aug Se r1sep Oct Oct [ ]Nov [X] NovDecVenting Dec [[ ]]Jan Feb Mar Apr [ May Jun Jul Aug [X Oct [Xj Nov [ Dec 6/10/2021 12:07 PM EnergyGaugeS USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (VVD) AM PM 78 80 78 80 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 fib 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. 0 ft2 Oft 0.3 BED 2 Defauit(8 Ibs/sq.ft. ft2 ft 0.3 BATH 2 Default(8 Ibslsq.ft. fie ft 0.3 BED 3 Default(8 Ibsfsq.ft. ft2 ft 0.3 WIC BED 2 Default(8 Ibslsq.ft. ft2 ft 0.3 BATH 4 Default(8 Ibslsq.ft. ft2 ft 0.3 BED 4 Default(8 Ibslsq.ft. ft2 ft 0.3 WIC BED 4 Default(8 Ibslsq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibslsq.ft. ft2 ft 0.3 LAUNDRY Default(8lbs/sq.ft, ft2 ft 0.3 KITCHEN BREAKF Default(8 lbslsq.ft. ft2 ft 0.3 DINING Default(8 lbslsq.ft, ft2 ft 0.3 FOYER Default(8 Ibslsq.ft. ft2 ft 0.3 GAR HALL GALLE Default(8 Ibslsq.ft. ft2 ft 0.3 POWDER Default(8 lbs/sq.ft, ft2 ft 0.3 GREAT ROOM Default(8 lbslsq.ft. ftz ft 0.3 CLUBROOM Default(8 Ibslsq.ft. ft2 ft 0.3 LIBRARY Default(8 Ibslsq.ft, ft2 ft 0.3 MASTER SUITE Defauit(8 Ibslsq.ft, ft2 ft 0.3 HIS WIC Default(8 Ibslsq.ft. ft2 ft 0.3 HIS BATH Default(8 Ibslsq.ft. ft2 ft 0.3 HER TIOLET Default(8 Ibsfsq.ft. ft2 ft 0.3 HER BATH Default(8 lbslsq.ft. ft2 ft 0.3 HERS 6/10/2021 12:07 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 5130 ARMINA PLACE, FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, Exterior R=4.1 1508.90 ft2 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent R=11 A 336.00 ft2 c. NIA R= ft2 4. Number of Bedrooms 4 d. NIA R= ftz 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1917.00 ft2 6. Conditioned floor area (ft2) 1917 b. NIA R= ft2 7. Windows- Description Area c. NIA R= ft2 a. U-Factor: Dbl, U=0.28 159.83 ft2 12. Ducts, location & insulation level R ft2 SHGC: SHGC=0.30 a. Sup: Attic, Ret: LAUNDRY, AK LAUNDRY 6 250 b. U-Factor: Dbl, U=0.55 42.00 ft2 SHGC: SHGC=0.34 13. Cooling systems kBtulhr Efficiency c. U-Factor: NIA ft2 a. Central Unit 35.2 SEER:16.00 SHGC: d. U-Factor: NIA ft2 SHGC: 14. Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 1.570 ft. a. Electric Strip Heat 32.0 COP:1.00 Area Weighted Average SHGC: 0.308 8. Skylights Description Area 15. Hot water systems a. U-Factor(AVG): NIA ft2 a. Electric Cap: 50 gallons SHGC(AVG): NIA EF: 0.95 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 1917.10 ft2 Credits (Performance method) Pstat b. NIA R= ft2 c. NIA R= ft2 I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. *"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6110/2021 12:07 PM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1