HomeMy WebLinkAboutENERGY LOT 24FORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: KHOV-LELIA
Builder Name: KHOVNANAIN HOMES
Street: 5130 ARMINA PLACE
Permit Office:
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: LELIA MODEL LOT 24 @ WATERSTONE
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
10. Wall Type�1844.9 sqft.)
Insulation Area
2. Single family or multiple family Detached
a. Concrete Block - Int Insul, Exterior
R=4.1 1508.90 ft2
3. Number of units, if multiple family 1
b. Frame - Wood, Adjacent
R=11.0 336.00 ft2
c. NIA
R_ ft2
4. Number of Bedrooms 4
d. NIA
R= ftZ
5. Is this a worst case? No
11. Ceiling Types (1917.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1917.00 ft2
6. Conditioned floor area above grade (ft2) 1917
b. NIA
R= ft2
Conditioned floor area below grade (ftZ) 0
c. NIA
R= ft2
7. Windows(201.8 sqft.) Description Area
12. Ducts
R ft2
a. U-Factor: Dbl, U=0.28 159.83 ft2
a. Sup: Attic, Ret: LAUNDRY, AH: LAUNDRY
6 250
SHGC; SHGC=0.30
b. U-Factor: Dbl, U=0.55 42.00 ft2
13. Cooling systems
kBtulhr Efficiency
SHGC: SHGC=0.34
a. Central Unit
35.2 SEERA6.00
c. U-Factor: NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 1.570 ft.
14. Heating systems
kBtulhr Efficiency
Area Weighted Average SHGC: 0.308
a. Electric Strip Heat
32.0 COP:1.00
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): NIA
a. Electric
Cap: 50 gallons
9. Floor Types (1917.1 sqft-) Insulation Area
EF: 0.950
a. Slab -On -Grade Edge Insulation R=0.0 1917.10 ft2
b. Conservation features
b. N/A R= ft2
None
c. NIA R= ft2
16. Credits
Pstat
Total Proposed Modified Loads: 59.66
Glass/Floor Area: 0.105
PASS
Total Baseline Loads: 61.14
1 hereby certify that the plans and spec" i ations covered by
Review of the plans and
�V'KlaE 3Z6,
this calculation are in compliance wit Florida Energy
specifications covered by this
M
Code.
calculation indicates compliance
�,,f�`�'` `.�,••
with the Florida Energy Code.
.r+rr,f k :" `,.d ••14
PREPARED BY:
Before construction is completed
W
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
p,B vwvt
OWNERIAGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
6/10/2021 12:07 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: KHOV-LELIA
Bedrooms: 4
Address Type:
Street Address
Building Type: User
Conditioned Area; 1917
Lot #
Owner Name: LELIA MODEL LOT 24 @ WA
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name: KHOVNANAIN HOMES
Rotate Angle: 0
Street:
5130 ARM INA PLACE
Permit Office:
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FORT PIERCE,
Family Type: Detached
FL,
NewlExisting: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1917
16614.7
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 EXT STE LIV PLUS 199
1765.1 No
0
4
1
No
Yes
Yes
2 WIC STE PLS BED 25
220 No
0
1
No
Yes
Yes
3 EX STE PLUS BED 132
1161.6 No
0
1
No
Yes
Yes
4 EX STE BATH 54
475.2 No
0
1
No
Yes
Yes
5 FOYER 81
712.8 No
0
1
No
Yes
Yes
6 HALL BATH 54
475.2 No
0
1
No
Yes
Yes
7 LAUNDRY 77
677.6 No
0
1
No
Yes
Yes
8 BED 3 126
1108.8 No
1
1
No
Yes
Yes
9 BED 2 126
1109 No
1
1
No
Yes
Yes
10 KIT GREAT RM DI 672
5644.8 No
0
1
No
Yes
Yes
11 M BATH 95
836 No
0
1
No
Yes
Yes
12 MASTER SUITE 210
1848 No
2
1
No
Yes
Yes
13 MASTER WIC 66
580.8 No
0
1
No
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge lnsulatio EXT STE LIV PL 46 ft 0
1993 ft2
----
0 1
0
2 Slab -On -Grade Edge lnsulatio WIC STE PLS BE 4.5 ft 0
25 ft2
----
0 1
0
3 S lab -On -Grade Edge lnsulatio EX STE
PLUS B 8.5 ft 0
132 ft2
-__-
0 1
0
4 Slab -On -Grade Edge lnsulatio EX STE BATH 1 ft 0
54 ft2
____
1 0
0
6/10/2021 12:07 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 2 of 6
I-URM R405-2020 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood Carpet
5SIab-On-Grade Edge Insulatio
FOYER 19 ft
0
81,3 ft2
----
1
0
0
6 Slab -On -Grade Edge Insulatio
HALL BATH 1 ft
0
54 ft2
--_-
1
0
0
7 Slab -On -Grade Edge Insulatio
LAUNDRY 7.5 ft
0
77 ft2
__--
1
0
0
8 Slab -On -Grade Edge Insulatio
BED 3 22.5 ft
0
126 ft2
-__-
0
1
0
9 Slab -On -Grade Edge Insulatio
BED 2 12.5 ft
0
126 ft2
___-
0
1
0
10SIab-On-Grade Edge Insuiatio
KIT GREAT RM 43.5 ft
0
672 ft2
----
1
0
0
11SIab-On-Grade Edge Insulatio
M BATH 9 ft
0
94.5 ft2
----
1
0
0
12SIab-On-Grade Edge Insulatio
MASTER SUITE 28 ft
0
210 ft2
----
0
1
0
13SIab-On-Grade Edge Insulatio
MASTER WIC 6 ft
0
66 ft2
____
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip Composition shingles 2076 ft2
0 ft2 Medium
N
0.9
No 0.9
No 0
22.6
ATTIC
/
V # Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1917
ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented)
EXT STE LIV PL
30
Blown
199 ft2
0.1
Wood
2 Under Attic (Vented)
WIC STE PLS BE
30
Blown
25 ft2
0.1
Wood
3 Under Attic (Vented)
EX STE PLUS B
30
Blown
132 ft2
0.1
Wood
4 Under Attic (Vented)
EX STE BATH
30
Blown
54 ft2
0.1
Wood
5 Under Attic (Vented)
FOYER
30
Blown
81 ft2
0.1
Wood
6 Under Attic (Vented)
HALL BATH
30
Blown
54 ft2
0.1
Wood
7 Under Attic (Vented)
LAUNDRY
30
Blown
77 ft2
0.1
Wood
8 Under Attic (Vented)
BED 3
30
Blown
126 ft2
0.1
Wood
9 Under Attic (Vented)
BEd 2
30
Blown
126 ft2
0.1
Wood
10 Under Attic (Vented)
KIT GREAT RM
30
Blown
672 ftz
0.1
Wood
11 Under Attic (Vented)
M BATH
30
Blown
95 ft2
0.1
Wood
12 Under Attic (Vented)
MASTER SUITE
30
Blown
210 ft2
0.1
Wood
13 Under Attic (Vented)
MASTER WIC
30
Blown
66 ft2
0.1
Wood
6/10/2021 12:07 PM EnergyGauge@ USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent �qpeSpace
Cavity Width
Height
Sheathing Framing
Solar
Below
0
1
SE
Exterior
Concrete Block - Int Ins6XT STE LIV
4.1 11
7
9
4
108.1 ft2
0
0
0.5
0
2
SW
Exterior
Concrete Block - Int InsEXT STE LIV
4.1 15
4
10
0
153.3 ft2
0
0
0.5
0
3
SW
Exterior
Concrete Block - Ink Ins1flX STE PLU
4.1 7
8
10
0
76.7 ft2
0
0
0.5
0
4
SE
Exterior
Concrete Block - Int InsuI FOYER
4.1 6
4
9
4
59.1 ft2
0
0
0.5
0
5
SW
Exterior
Concrete Block - Int Insul FOYER
4.1 11
4
10
0
113.3 ft2
0
0
0.5
0
6
NE
Exterior
Concrete Block - Int Insul BED 3
4.1 11
7
9
4
108.1 ft2
0
0
0.5
0
7
NE
Exterior
Concrete Block- Int Insul BED 2
4.1 11
7
9
4
108.1 ft2
0
0
0.5
0
8
SW
Exterior
Concrete Black - Int InsKIT GREAT
4.1 25
2
10
0
251.7 ft2
0
0
0.5
0
9
NW
Exterior
Concrete Block - Int InsKIT GREAT
4.1 15
1
9
4
140.8 ft2
0
0
0.5
0
10
NE
Exterior
Concrete Block - Int Insul M BATH
4.1 8
9
9
4
81.7 ft2
0
0
0.5
0
11
NE
Exterior
Concrete Block - Int InsMASTER SUI
4.1 14
1
9
4
131.4 ft2
0
0
0.5
0
12
NW
Exterior
Concrete Block - Int 1nsMASTER SUI
4.1 13
1
9
4
122.1 ft2
0
0
0.5
0
13
NW
Exterior
Concrete Block - Int InSLUASTER WI
4.1 5
10
9
4
54.4 ft2
0
0
0.5
0
14
NW
Garage
Frame - Wood KIT GREAT
11 36
0
9
4
336.0 ft-'
0
0
0.5
0
DOORS
#
Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
SW
Insulated EXT STE LIV
None
.39
3
2
6 8
21,1
ft2
2
SW
Insulated EXT STE LIV
None
.39
3
2
6 8
21.1
ft2
3
NW
Wood KIT GREAT
None
.39
3
2
6 8
21.1
ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1
SE 1
Metal Double (Tinted) Yes
0.28 0.3
N
22.9 ft2
1 It 0 in
1 ft 0 in
None
None
2
SW 3
Metal Double (Tinted) Yes
0.28 0.3
N
23.0 ft2
6 ft 0 in
1 ft 0 in
None
None
3
SW 5
Metal Double (Tinted) Yes
0.28 0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
4
NE 6
Metal Double (Tinted) Yes
0.28 0.3
N
15.0 ft2
1 ft 0 in
1 ft0 in
None
None
5
NE 7
Metal Double (Tinted) Yes
0.28 0.3
N
15.0 ft2
1 ft 0 in
1 ft 0 in
None
None
6
SW 8
Metal Double (Tinted) Yes
0.28 0.3
N
23.0 ft2
1 ft 0 in
1 ft 0 in
None
None
7
NW 9
Metal Double (Tinted) Yes
0.28 0.3
N
23.0 ft2
1 ft 0 in
1 ft 0 in
None
None
8
NW 9
Metal Double (Tinted) Yes
0.55 0.34
N
42.0 ft2
1 ft 0 in
1 ft 0 in
None
None
9
NW 12
Metal Double (Tinted) Yes
0.28 0.3
N
22.9 ft2
1 ft 0 in
1 ft 0 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg, Wall Height
Exposed Wall Insulation
1
380
ft2 380 ft2
64 ft
8 ft
1
6/10/2021 12:07 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6
FORM R405-2020
# Scope Method
1 Wholehouse Proposed ACH(50)
# System Type
1 Electric Strip Heat!
# System Typ(
1 Central Unit/
INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
SLA CFM 50 ELA EgLA ACH ACH 50
.000385 1938A 106.35 199.65 .1304 7
HEATING SYSTEM
Subtype Speed Efficiency Capacity Block Ducts
None COP:1 32 kBtulhr 1 sys#1
COOLING SYSTEM
# System Type SubT
1 Electric None
FSEC
Cert # Company Name
None None
Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts
Split Singl SEER: 16 35.2 kBtulhr cfm 0.81 1 sys#1
HOT WATER SYSTEM
Location EF Cap Use SetPnt Conservation
Garage 0.95 50 gal 60.9 gal 120 deg None
SOLAR HOT WATER SYSTEM
Collector Storage
System Model # Collector Model # Area Volume FEF
ft2
DUCTS
/
---- Supply
----
---- Return ----
Air
CFM 25
CFM25
HVAC #
�/
# Location R-Value Area
Location Area
Leakage Type
Handler
TOT
OUT ON
RLF
Heat
Cool
1 Attic 6
250 ft2
LAUNDRY 1 ft2
Default Leakage
LAUNDRY
(Default)
(Default)
1
1
TEMPERATURES
Programable Thermostat: Y
Ceding Fans:
Cooling
Heating
[ ]] Jan Feb
[7C] Jan Feb
Mar
Mar
ki
Apr Ma
Apr f I May
Jun X Jul
Jun Jul
rj
AuSe
rj Aug
Se
r1sep
Oct
Oct
[ ]Nov
[X] NovDecVenting
Dec
[[ ]]Jan Feb
Mar
Apr [ May
Jun Jul
Aug
[X Oct
[Xj Nov
[
Dec
6/10/2021 12:07 PM EnergyGaugeS USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9 10
11
12
Cooling (VVD)
AM
PM
78
80
78
80
78
78
78
78
78
78
78
80 80
80
80
78
78
78
78
78
78 78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78 78
78
78
PM
78
78
78
78
78
78
78
78
78 78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
68
68
68
68
68 68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68 68
68
68
PM
68
68
68
68
fib
68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibslsq.ft.
0 ft2
Oft
0.3
BED 2
Defauit(8 Ibs/sq.ft.
ft2
ft
0.3
BATH 2
Default(8 Ibslsq.ft.
fie
ft
0.3
BED 3
Default(8 Ibsfsq.ft.
ft2
ft
0.3
WIC BED 2
Default(8 Ibslsq.ft.
ft2
ft
0.3
BATH 4
Default(8 Ibslsq.ft.
ft2
ft
0.3
BED 4
Default(8 Ibslsq.ft.
ft2
ft
0.3
WIC BED 4
Default(8 Ibslsq.ft.
ft2
ft
0.3
BATH 3
Default(8 Ibslsq.ft.
ft2
ft
0.3
LAUNDRY
Default(8lbs/sq.ft,
ft2
ft
0.3
KITCHEN BREAKF
Default(8 lbslsq.ft.
ft2
ft
0.3
DINING
Default(8 lbslsq.ft,
ft2
ft
0.3
FOYER
Default(8 Ibslsq.ft.
ft2
ft
0.3
GAR HALL GALLE
Default(8 Ibslsq.ft.
ft2
ft
0.3
POWDER
Default(8 lbs/sq.ft,
ft2
ft
0.3
GREAT ROOM
Default(8 lbslsq.ft.
ftz
ft
0.3
CLUBROOM
Default(8 Ibslsq.ft.
ft2
ft
0.3
LIBRARY
Default(8 Ibslsq.ft,
ft2
ft
0.3
MASTER SUITE
Defauit(8 Ibslsq.ft,
ft2
ft
0.3
HIS WIC
Default(8 Ibslsq.ft.
ft2
ft
0.3
HIS BATH
Default(8 Ibslsq.ft.
ft2
ft
0.3
HER TIOLET
Default(8 Ibsfsq.ft.
ft2
ft
0.3
HER BATH
Default(8 lbslsq.ft.
ft2
ft
0.3
HERS
6/10/2021 12:07 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
5130 ARMINA PLACE, FORT PIERCE, FL,
1. New construction or existing
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, Exterior
R=4.1
1508.90 ft2
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=11 A
336.00 ft2
c. NIA
R=
ft2
4. Number of Bedrooms
4
d. NIA
R=
ftz
5. Is this a worst case?
No
11. Ceiling Type and insulation level
Insulation
Area
a. Under Attic (Vented)
R=30.0
1917.00 ft2
6. Conditioned floor area (ft2)
1917
b. NIA
R=
ft2
7. Windows- Description
Area
c. NIA
R=
ft2
a. U-Factor: Dbl, U=0.28
159.83 ft2
12. Ducts, location & insulation level
R ft2
SHGC: SHGC=0.30
a. Sup: Attic, Ret: LAUNDRY, AK LAUNDRY
6 250
b. U-Factor: Dbl, U=0.55
42.00 ft2
SHGC: SHGC=0.34
13. Cooling systems
kBtulhr
Efficiency
c. U-Factor: NIA
ft2
a. Central Unit
35.2 SEER:16.00
SHGC:
d. U-Factor: NIA
ft2
SHGC:
14. Heating systems
kBtu/hr
Efficiency
Area Weighted Average Overhang Depth:
1.570 ft.
a. Electric Strip Heat
32.0
COP:1.00
Area Weighted Average SHGC:
0.308
8. Skylights Description
Area
15. Hot water systems
a. U-Factor(AVG): NIA
ft2
a. Electric
Cap:
50 gallons
SHGC(AVG): NIA
EF: 0.95
b. Conservation features
9. Floor Types
Insulation Area
None
a. Slab -On -Grade Edge Insulation
R=0.0 1917.10 ft2
Credits (Performance method)
Pstat
b. NIA
R= ft2
c. NIA
R= ft2
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature:
Address of New Home:
Date:
City/FL Zip:
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
*"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6110/2021 12:07 PM EnergyGauge@ USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1