HomeMy WebLinkAbout11690 palomino faAPPLICATION #:AP1511203
STATE OF FLORIDA PERMIT #:56-SF-2093092
DEPARTMENT OF HEALTH DOCUMENT #: F11750476
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:08/18/2021
FEE PAID : 95.00
RECEIPT #:56-PID-5166022
APPLICANT: Cherrie La Fond
AGENT: John Murtagh
PROPERTY ADDRESS: 11690 Palomino Dr Port Saint Lucie, FL 34987
LOT: 34
BLOCK: A
SUBDIVISION:
Pony Pines ID#: 3309-605-0037-000-2
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR
RULE AND MUST BE CORRECTED.
TANK INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE [1] 1090.00 [21 [
] [271
SURFACE WATER 100 FT
[ ] [02]
TANK MATERIAL Polypropylene [
] [28]
DITCHES FT
[ ] [031
OUTLET DEVICE [ ]
[291
PRIVATE WELLS 91 FT
[ ] [041
MULTI -CHAMBERED [LIJ N ] [ ]
(30]
PUBLIC WELLS FT
[ ] [051
OUTLET FILTER Polylok PL-68 [ ]
[311
IRRIGATION WELLS FT
[ ] [061
LEGEND 1. 70-143-11DC4 2. [ ]
[321
POTABLE WATER 66 FT
[ ] [071
WATERTIGHT [ ]
[331
BUILDING FOUNDATIONS 6.5 FT
[ ] [081
LEVEL [ ]
[34]
PROPERTY LINES 45 FT
[ ] [091
DEPTH TO LID [ ]
[351
OTHER FT
DRAINFIELD
INSTALLATION
FILLED / MOUND SYSTEM
[ ] [10]
AREA [11 543.36 [2] SQFT [ ]
[361
DRAINFIELD COVER
[ ] [111
DISTRIBUTION BOX HEADER X [ ]
[371
SHOULDERS
[ ] [121
NUMBER OF DRAINLINES 1. 6.00 2. [ ]
[38]
SLOPES
[ ] [131
DRAINLINE SEPARATION [ ]
[391
STABILIZATION 12/10/2021
[ ] [141
DRAINLINE SLOPE
[ ] [151
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [16]
ELEVATION [ ABOVE / BELOW ]BM 9.00 [ ]
[40]
UNOBSTRUCTED AREA
[ ] [171
SYSTEM LOCATION [ ]
[411
STORMWATER RUNOFF
[ ] [181
DOSING PUMPS [ ]
[421
ALARMS
[ ] [19]
AGGREGATE SIZE [ ]
[431
MAINTENANCE AGREEMENT
[ ] [201
AGGREGATE EXCESSIVE FINES [ ]
[441
BUILDING AREA
[ ] [211
AGGREGATE DEPTH [ ]
[45]
LOCATION CONFORMS WITH SITE PLAN
FILL
/ EXCAVATION MATERIAL [ ]
[461
FINAL SITE GRADING
[ ] [221
FILL AMOUNT [ ]
[471
CONTRACTOR Abner Leyva (Leyva Plumbing
[ ] [231
FILL TEXTURE [ ]
[48]
OTHER INFILTRATOR Quick4 Plus EQ36 LP
[ ] [241
EXCAVATION DEPTH
ABANDONMENT
[ ] [25]
AREA REPLACED [ ]
(49]
TANK PUMPED
[ ] (261
REPLACEMENT MATERIAL [ ]
[501
TANK CRUSHED & FILLED
Comments: Comments are on page 2.
CONSTRUCTION
[ APPROVED c
St. Lucie CHD DATE: 09/01/2021
DISAPPROVED Environ ental Specialist I ri
Ingram
(ENVIRONMENTAL HEALTH)
FINAL SYSTEM
[ APPROVED / DISAPPROVED ]:
St. Lucie CHD DATE: 12/10/2021
Environmental Specialist III
an J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of
Violations on following page)
DH 4016, 08/09 (Obsoletes all previous editions which may not
be used)
Incorporated:
64E-6.003, FAC
Page 2 of 3
EH Database v 1.0.1 AP1511203
EID2093092
STATE OF FLORIDA
r DEPARTMENT OF HEALTH
"L+Q ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
r� yL I
Violation Number Comment
Comments
APPLICATION #:AP1511203
PERMIT #:56-SF-2093092
DOCUMENT # : FI 1750476
DATE PAID:08/18/2021
FEE PAID:95.00
RECEIPT #:56-PID-5166022
The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400
gpd.
New ST, filter, DT, and 6x8 long TRENCH DF installed. No violations, system ok to cover, home owner notified onsite. Needs final
inspection for mound system and final site grading.
Final system approved. Contractor and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1511203 EID2093092