Loading...
HomeMy WebLinkAbout7467 gullotti pl faAPPLICATION # : AP 1481303 STATE OF FLORIDA PERMIT #:56-SF-2058841 DEPARTMENT OF HEALTH DOCUMENT #: F11751339 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AFINAL APPROVAL DATE PAID:04/30/2020 ND FEE PAID-1 15.00 RECEIPT #:56-PID-4368546 APPLICANT: Joshua Stiller AGENT: Alexander J. Piazza PSM, Inc PROPERTY ADDRESS: 7467 Gullottl PI Port Saint Lucie, FL 34952 LOT: 6 BLOCK: 3 SUBDIVISION: St. Lucie Gardens ID#: 3414-501-106-200-0 CHECKED [XI ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE (1] 1050.00 [2] [ ] [27] SURFACE WATER 94 FT [ ] [02] TANK MATERIAL Polypropylene [ ] [28] DITCHES FT [ ] [03] OUTLET DEVICE [ ] [29] PRIVATE WELLS 78 FT [ ] [04] MULTI -CHAMBERED [ Y N ] [ ] [30] PUBLIC WELLS FT [ ] [05] OUTLET FILTER PolylokPL-68 [ ] [31] IRRIGATION WELLS FT [ ] [061 LEGEND 1. 70-156-10DC3 2. [ ] [32] POTABLE WATER 45 FT [ ] [07] WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 7 FT [ ] [08] LEVEL [ ] [34] PROPERTY LINES 32 FT [ ] [09] DEPTH TO LID [ ] [35] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 679.2 [2] SQFT [ ] [36] DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [37] SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. 6.00 2. [ ] [38] SLOPES [ ] [13] DRAINLINE SEPARATION [ ] [39] STABILIZATION 12/14/2021 [ ] [14] DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM 0.00 [ ] [40] UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [41] STORMWATER RUNOFF [ ] [18] DOSING PUMPS [ ] [42] ALARMS [ ] (19] AGGREGATE SIZE [ ] [43] MAINTENANCE AGREEMENT [ ] [20] AGGREGATE EXCESSIVE FINES [ ] (441 BUILDING AREA [ ] [211 AGGREGATE DEPTH [ ] [45] LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [46] FINAL SITE GRADING [ ] [471 CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [22] FILL AMOUNT [ l [48] OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [23] FILL TEXTURE [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [49] TANK PUMPED [ ] [26] REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION I APPROVED / — St. Lucie CHD DISAPPROVED ] ' Enviropmental Speciali5f1prian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ I APPROVED / DISAPPROVED ]: St. Lucie CHD Environmental Sped; t III Brian J Ingram (ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC EH Database v 1.0.1 AP1481303 EID2058841 DATE: 0R/24/2021 DATE: 12/14/2021 Page 2 of 3 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL Violation Number Comment Comments APPLICATION #:AP1481303 PERMIT #:56-SF-2058841 DOCUMENT #: F11751339 DATE PAID : 04/30/2020 FEE PAID:115.00 RECEIPT #:56-PID-4368546 The system is sized for 4 bedrooms with a maximum occupancy of 8 persons (2 per bedroom), for a total estimated flow of 400 gpd. New ST, filter, and 6x10 long BED DF installed. No violations, system ok to cover, contractor notified onsite. Needs final nspection gutters, mound system, and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1481303 EID2058841