HomeMy WebLinkAboutA2P0018B_Structural Opinion Letter_TMobile_196ft_10.12.21 S&S(1) Date: October 12, 2021 USA
ENGINEERING
Britnee Zimmerman
Smartlink USA Engineering, Inc.
Program Manager 2818 Cypress Ridge Blvd., Suite 110
Wesley Chapel, FL 33544
(813) 994-0365
Subject: Structural Opinion Letter
T-Mobile: Site Number: A2P0018B
Site Name: MD7/Princess
USA Engineering Designation: Project Number: A2P0018B
Site Data: 9650 South Ocean Drive, Hutchinson Island, FL, Saint Lucie County
Latitude: 27' 17' 20.4", Longitude: -80° 12'45.3"
196-Foot-Tall Building
Dear Ms. Zimmerman,
We have performed a structural assessment of the building roof and existing equipment platform installed
within T-Mobile's equipment lease space at the above referenced address. The assessment is based on
the Construction Drawings by USA Engineering, dated 10/01/2021 and Radio Frequency Data Sheet
(RFDS Version 7) by T-Mobile, dated 07/21/2021, provided by the client. The original building drawings were
not available to us at the time of this assessment.
The existing structure is an equipment platform bearing on the building roof.The platform will carry one (1)
proposed Ericsson 6160 SSC cabinet and one (1) proposed Ericsson 6160 Battery cabinet. No additional
equipment will be added at the T-Mobile electrical panel area. (1) site support cabinet and (1) battery cabinet will
be removed prior to prior to the installation of the proposed equipment.
Looking at this installation from a structural prospective, it is the engineering judgment of this office that the
installation will have no appreciable impact on either the vertical or horizontal loads imposed on
the platform or building rooftop. The equipment platform and rooftop are capable of supporting the proposed
equipment configuration.
No conclusions, expressed or implied, shall indicate that USA Engineering has made an evaluation of the original
design, materials, fabrication, or potential erection deficiencies. In addition, the conclusions expressed herein are
based upon the information contained within the aforementioned documents. Any information contrary to that
assumed for the purpose of preparing this assessment could alter the findings and conclusions as stated.
Digitally signed by Marc P Maier
DN:
arc P Maier 178D 0.9.2342.19200300.100.1.1 c=A01410 OOOOO
Maier,
Respectfully submitte 178DCE5208F00010190,cn=MarcPMaier,
\\11111111// o=GOFF COMMUNICATIONS,c=US
\\ // D e:2p21.10.12 16:18:25-04'00'
P Mq � is item has been electronically
T� signed and sealed by Marc P.
Marc Maier, P.E. �P.•'%f,E N s•• p�� Maier,P.E.,FL License#72513
FL PE No: 72513 using a Digital Signature.
COA No: 31705 No 72513
* :• •; * = Printed Copies of this document are
* _ not considered signed and sealed
.• and the signature must be verified
STATE OF •• on any electronic copies.
,�0NA�;0�`�� Oct 12 2021
USA Engineering, LLC Office: (813) 994-0365
2818 Cypress Ridge Blvd., Suite 110
Wesley Chapel, FL 33544