Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETvit IL .. Lr ST. LUCIE VIVORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A,8,C Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A,B,D 194,5,8,7 Concrete or Clay Tile A, B, D, E 1,2,36,5,6.7 Metal Roofs A, B, D 12,3,4,5 0.7. Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3p,6,6,7 ATTACHMENTS REQUIRED As AnnlicahW- 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations j General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE °V'V1nRKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval No.: Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: _ Zone 2: _Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Type: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material; Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_" oc @ Lap, # Rows_ @ _" m Zone l:_" oc @ Lap, # Rows — 0 _" m Zone 2_" oc @ Lap, # Rows _ @ _' Go Zone 3:_" oc @ Lap, # Rows_ @ _ m Number of Fasteners Per Insulation Board: Zone 1':_Zone 1:_Zone 2:_Zone 3 Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ST. LUCIE WORKS Section D (Steep Slope Roof System) Beef system Manufacturer: OWENS CONRING DURATION Notice of Acceptance Number: FL#10674.1 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: -57 Zone 2e:--J-01Zone 2n:_Zone 2o-98sone 3e:-128 Zone 3r: Deck Type: PLYWOOD \UndeAayment PEEL&STICK-OW NS OMNS CORNING TRI-BUILT FL#34539.1 rrier: ation7tenef Type &.Specmg: 6'FIELD 14"PERIMETER, BD RING SHANK NNLS Adhesive Type:—� Cap Sheet Mean Ro�Height: 15' FT I Roof Co"d g: SHINGLES Type &Sim Drip 2"x2" Fdne ST. LUCIE ' ORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mrvalues are greater than or equal to the M,values, for each area of the roof, then the till attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: -X.i-- _j_lllq. Mn- Product Approval M, (Zone 2e: '_x1- _)- Mg: _=M Product A m- Approval M (Zone 2n: ;_xl =-)-Mg:_=�_ Product Approval M, (Zone 2r. _X)L_=-)-Mg:-=101,,_ Product Approval Mr. (Zone 3e: -x)L _ I-Mg:_=K,_ Product Approval Mr (Zone 3r. _X7t-=-j-W-=M,_ Product Approval M, Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below -Product Approval M required Moment Resistance' 15' 20' 25' 30' 40' 34.4 36.5 38.2 39.7 42.2 Mr 2.2 34.4 36.0 37.4 39.8 0.4 32.2 33.8 35.1 37.3 8.4 30.1 31.6 32.8 34.9 6.4 28.0 29.4 30.5 32.4 7:12C24.4 4.4 25.9 27.1 28.2 30.0 •••"'• "'_" •• w,9uu,.ua„ wun a nnof moment Dasea we systems For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the F- values are greater than or equal to the Fr values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: _x L x W:=_-W: cos r= F,t Product Approval F' (Zone 2e: _xL =xW:=---J_W cos r_ Fog Product Approval F' (Zone 2n:_x L=xW:=_J-W; cos r_Frm_ Product Approval F' (Zone 2r: _x L=xW:=_)-W: cos r_For_ Product Approval F' (Zone 3e:_x L=xW:= J-W:_Cos r_F,3g Product Approval F' (Zone 3r:_x L_x W:=____j-W:_COS r =Fr3, Product Approval F' Where to obtain Information Description Symbol Where to find Design Pressure Zones 1, 2e, 2n, 2n 3e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope a Job Site Aerodynamic Muhiplier a Product Approval Restoring Moment due to Gravity Mr Product Approval Attachment Resistance Mr Product Approval Required Moment Resistance Ms Calculated Minimum Attachment Resistance F Product Approval Required Uplift Resistance F, Calculated Average Tile Weight W Product Approval Tile Dimensions L=length W=width Product Approval All calculations must be submittedtothe building official at the time of per it application.