HomeMy WebLinkAbout354 melton dr faAPPLICATION #:AP1526397
STATE OF FLORIDA PERMIT # : 56-S F-2110355
DEPARTMENT OF HEALTH DOCUMENT #: F11751955
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:12/01/2021
FEE PAID:25.00
RECEIPT #:56-PID-5377019
APPLICANT: The Outdoors Quality, LLC
AGENT. AlexanderJ. Piazza PSM, Inc
PROPERTY ADDRESS: 354 Melton (was TBD) Dr Fort Pierce, FL 34982
LOT: 17 $ 18
BLOCK: 3
SUBDIVISION:
Ruhlman ID# : 3403-805-0057-000-1
CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED.
TANK
INSTALLATION
SETBACKS
[ ] [01]
TANK SIZE [11 1090.00 [2] [ ]
[271
SURFACE WATER FT
[ ] [02]
TANK MATERIAL Polypropylene [ ]
[281
DITCHES FT
[ ] [031
OUTLET DEVICE [ ]
[29]
PRIVATE WELLS 76 FT
[ ] (041
MULTI -CHAMBERED [ Y N ] [ ]
[30]
PUBLIC WELLS FT
[ ] [05]
OUTLET FILTER PolylokPL-68 [ ]
[31]
IRRIGATION WELLS FT
[ ] [06]
LEGEND 1. 70-143-11DC4 2. [ ]
[32]
POTABLE WATER 40 FT
[ ] [07]
WATERTIGHT [ ]
[33]
BUILDING FOUNDATIONS 5 FT
[ ] [08]
LEVEL [ ]
[34]
PROPERTY LINES 7 FT
[ ] [09]
DEPTH TO LID [ ]
[35]
OTHER FT
DRAINFIELD
INSTALLATION
FILLED / MOUND SYSTEM
[ ] [10]
AREA [1] 375 [2] SQFT [ ]
[36]
DRAINFIELD COVER
[ ] [11]
DISTRIBUTION BOX HEADER x [ ]
[371
SHOULDERS
[ ] [12]
NUMBER OF DRAINLINES 1. 5.00 2. [ ]
[38]
SLOPES
( ] [13]
DRAINLINE SEPARATION [ ]
[39]
STABILIZATION 12/16/2021
[ ] [14]
DRAINLINE SLOPE
[ ] [15]
DEPTH OF COVER
ADDITIONAL INFORMATION
[ ] [16]
ELEVATION [ ABOVE / BELOW ]BM 2.00 [ ]
[40]
UNOBSTRUCTED AREA
[ ] [17]
SYSTEM LOCATION [ ]
[41]
STORMWATER RUNOFF
[ ] [181
DOSING PUMPS [ ]
[42]
ALARMS
[ ] [19]
AGGREGATE SIZE [ ]
[43]
MAINTENANCE AGREEMENT
[ ] [20]
AGGREGATE EXCESSIVE FINES [ ]
[44]
BUILDING AREA
[ ] [21]
AGGREGATE DEPTH [ ]
(45]
LOCATION CONFORMS WITH SITE PLAN
FILL
/ EXCAVATION MATERIAL [ ]
[46]
FINAL SITE GRADING
[ ]
[47]
CONTRACTOR Bruce T Mc Cullers (Reliable T
[ ] [22]
FILL AMOUNT
[ ]
[48]
OTHER ADS Septic Stack-9 (9 pipes - 2 tier)
[ ] [23]
FILL TEXTURE
[ ] [24]
EXCAVATION DEPTH
ABANDONMENT
[ ] [25]
AREA REPLACED [ ]
(49]
TANK PUMPED
[ ] [26]
REPLACEMENT MATERIAL [ ]
[50]
TANK CRUSHED & FILLED
Comments: Comments
are on page 2.
42
/ ✓`�-
St. Lucie CHD DATE: 04/27/2021
CONSTRUCTION
[ APPROVED
DISAPPROVED ] ' Environ ntal Specialist I icol
ontanez (Florida Department of He
FINAL SYSTEM
[ APPROVED / DISAPPROVED ] :
St. Lucie CHD DATE: 12/16/2021
Environmental Specialist III B
n J Ingram (ENVIRONMENTAL HEALTH)
(Explanation of Violations on following page)
DH 4016, 08/09
(Obsoletes all previous editions which may not
be used)
Incorporated:
64E-6.003, FAC
Page 2 of 3
EH Database v 1.0.1 AP1526397
EID2110355
STATE OF FLORIDA
DEPARTMENT OF HEALTH
ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM
CONSTRUCTION INSPECTION AND FINAL APPROVAL
Violation Number Comment
Comments
APPLICATION #:AP1526397
PERMIT #:56-SF-2110355
DOCUMENT #: F11751955
DATE PAID :12/01 /2021
FEE PAID :25.00
RECEIPT #:56-PID-5377019
The system is sized for 3 bedrooms with a maximum occupancy of 6 persons (2 per bedroom), for a total estimated flow of 300
gpd.
New ST, filter, and 5x25' long TRENCH DF installed. No violations, system ok to cover, contractor notified onsite. Needs final
inspection for well installation and setback, mound system and final site grading.
Final system approved. Contractor and building department emailed final approval.
DH 4016, 08/09 (Obsoletes all previous editions which may not be used)
Incorporated: 64E-6.003, FAC Page 2 of 3
EH Database v 1.0.1 AP1526397 EID2110355