HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETST. I_ L: .. LUCIE WORKS
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
i
Low Slope Application
Prescriptive BUR-RAS 150
Asphaltic Shingles
Concrete or Clay Tile
Metal Roofs
Wood Shingles and
Shakes
Other
Required Sections of
the Permit Application
Form
A,B,C
A, B, C
A, B, D
A, B, D, E
A,B,D
A,B,D
As Applicable
Attachments Required
See List Below
1,2,3,4,5,6,7
2,4,5,5,7
1 A,4,5,6,7
1,2,3,4,5,6,7
1,Z3,4,5,5,7
1 A,4.5,6,7
1,2,3,4,5,6,7
ATTACHMENTS REQUIRED As Applicable)-
1. Fire Directory Listing Page
2. From Product Approval:
Front Page
Specific System Description
Specific System Limltations
General Limitations
Applicable Detail Drawings
3, Design Calculations per Chapter 15, or if applicable, RAS 127 or RAS 128
4. other Component of Product Approval
5. Municipal Permit Application
5. Owners Notification for Roofing Considerations (Reroofing Only)
7. Any Required Roof Testing/Calculatton Documentation
Form RooflnfoFeb21 Rev Feb 18, 2D21
ST. LUCIE WORKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': _ Zone 1: _ Zone 2: _Zone 3: _
Max. Design Pressure, from the specific product approval
Deck:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. all Ply(s):
Anchor/Base Sheet Fastener/Bonding Material:
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding Material:
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material;
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':_" oc @ Lap, It Rows_ @ _ ao
Zone 1:_" oc @ Lap, # Rows _ ®_° to
Zone 2:_." oc @ Lap, # Rows— @ _ ao
Zone 3:_" oc @ Lap, # Rows_ @ _' co
Number of Fasteners Per insulation Board:
Zone V: Zone 1:__Zone 2:_Zone 3
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc..
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spacing or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
LTw LUC E WORK
Section 1] (Steep Slope Roof System)
Roof system Manufacturer: JA TAYLOR ROOFING 5V CRIMP
Notice of Acceptance Number: FL#17443.1
Minimum Design Wind Pressures, If Applicable (From RA5127 or Calculations):
Zone 1: -80 Zone 2e: -80 Zone 2n:-88Zone 2r: -80 Zone 3e-137 Zone 3r:-88
Deck Type: I PLYWOOD
Type Underiayment PEEL & STICK-OWENS CORNING POLYGLASS MTS FL05259.1
Roof Slope:
12
Insulabol
Fire Barrier:
Ridge Verl#ilation? Fastener Type & Spacing: 6" FIELD 1 4" PERIMETER, 80 RING SHANK iJAILS
Adhesive Type:
Type Cap Sheet: I
Mean Roof Height: 15' FT Roof Covering: METAL
Type & Size Drip Ex2-
Edge:
ST. LUCIE WORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1
or 2. Compare the values for M, with the values from Mf. If the Mr values
are greater than or equal to the M,values, for each area
of the roof, then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RAS 12T
(Zone 1: _x),_= _ I-Mgt_=Mn_
Product Approval Mi
(Zone 2e:-_x1,_=- Mg:
_=My_ Product Approval M•
(Zone 2n: _x7. = -MP-= -_
M,a,_ Product Approval Mr
(Zone 2r: _xx_= -- - Mg:
-=Mo. Product Approval Mr
(Zone 3e: '_xll_=-1_MG-=Ma•--
Product Approval M
(Zone 3r: _x)_= _)-illg:-=Me-
Product Approval Mr
Method 2 "Simplified
Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below_Product
Approval M
, required Moment Resistance -
Mean
5'
20'
25'
30,
40'
4.4
36.5
38.2
39.7
42.2
n7:,224M4r
2.2
34.4
36.0
37.4
39.8
.4
32.2
33.8
35.1
37.3
.4
30.1
31.6
32.8
34.9
.4
28.0
29.4
30.5
32.4
4.4
25.9
27.1
28.2
30.0
-- --.............. o list ui niomenc Case. Cie systems
• For Uplift based tile systems use Method 3. Compare the values for F' with
the values for F, If the F'values are greater than or
equal to the F, values, for each area of the roof, then the tile attachment method
is acceptable.
Method 3 "Uplift Based Tile Calculations
Per RAS 12T
(Zone 1:
_x L_ x W:=_) -W:_ cos r--- =F,c_
Product Approval F'
(Zone 2e:_x
L=xW:=J-W: Cos _�=Fa•_
ProduRApproval F'
(Zone 2re_xL_zW:=
-W; cos r=Fan
Product Approvalp
(Zone 2r:
_x L_=x W:=... j -W: cos r= F,z,_
Product ApproVal F'
(Zone 3e:_x
L=xW:- _)-W;_Cos r= F,3
Product Approval F'
(Zone 3r:
_x L_x W:=_)-W:_Cos r=F,3,
Product Approval F'
Where to Obtain lnf
rmatioo
Description
Symbol
Wheretoknd
Design Pressure
Zones 1, 2e, Zn, 293e, 3r
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
H
Job Site
Roof Slope
B
Job Site
Aerodynamic Muklplier
a
Product Approval
Restoring Moment due to Gravity
Ms
Product Approval
Attachment Resistance
Mf
Product Approval
Required Moment Resistance
Mr
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplik Resistance
F,
Calulated
Average Tile Weight
W
Pro
ua Approval
Tile Dimensions
L=length W=width
Pr
uct Approval
All Calculations must be submitted to the building official at the time of pertn
h application.