Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETST. I_ L: .. LUCIE WORKS ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System i Low Slope Application Prescriptive BUR-RAS 150 Asphaltic Shingles Concrete or Clay Tile Metal Roofs Wood Shingles and Shakes Other Required Sections of the Permit Application Form A,B,C A, B, C A, B, D A, B, D, E A,B,D A,B,D As Applicable Attachments Required See List Below 1,2,3,4,5,6,7 2,4,5,5,7 1 A,4,5,6,7 1,2,3,4,5,6,7 1,Z3,4,5,5,7 1 A,4.5,6,7 1,2,3,4,5,6,7 ATTACHMENTS REQUIRED As Applicable)- 1. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limltations General Limitations Applicable Detail Drawings 3, Design Calculations per Chapter 15, or if applicable, RAS 127 or RAS 128 4. other Component of Product Approval 5. Municipal Permit Application 5. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculatton Documentation Form RooflnfoFeb21 Rev Feb 18, 2D21 ST. LUCIE WORKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: _ Zone 2: _Zone 3: _ Max. Design Pressure, from the specific product approval Deck: Gauge Thickness: Slope: Anchor/Base Sheet & No. all Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material; Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':_" oc @ Lap, It Rows_ @ _ ao Zone 1:_" oc @ Lap, # Rows _ ®_° to Zone 2:_." oc @ Lap, # Rows— @ _ ao Zone 3:_" oc @ Lap, # Rows_ @ _' co Number of Fasteners Per insulation Board: Zone V: Zone 1:__Zone 2:_Zone 3 Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. LTw LUC E WORK Section 1] (Steep Slope Roof System) Roof system Manufacturer: JA TAYLOR ROOFING 5V CRIMP Notice of Acceptance Number: FL#17443.1 Minimum Design Wind Pressures, If Applicable (From RA5127 or Calculations): Zone 1: -80 Zone 2e: -80 Zone 2n:-88Zone 2r: -80 Zone 3e-137 Zone 3r:-88 Deck Type: I PLYWOOD Type Underiayment PEEL & STICK-OWENS CORNING POLYGLASS MTS FL05259.1 Roof Slope: 12 Insulabol Fire Barrier: Ridge Verl#ilation? Fastener Type & Spacing: 6" FIELD 1 4" PERIMETER, 80 RING SHANK iJAILS Adhesive Type: Type Cap Sheet: I Mean Roof Height: 15' FT Roof Covering: METAL Type & Size Drip Ex2- Edge: ST. LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mf. If the Mr values are greater than or equal to the M,values, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RAS 12T (Zone 1: _x),_= _ I-Mgt_=Mn_ Product Approval Mi (Zone 2e:-_x1,_=- Mg: _=My_ Product Approval M• (Zone 2n: _x7. = -MP-= -_ M,a,_ Product Approval Mr (Zone 2r: _xx_= -- - Mg: -=Mo. Product Approval Mr (Zone 3e: '_xll_=-1_MG-=Ma•-- Product Approval M (Zone 3r: _x)_= _)-illg:-=Me- Product Approval Mr Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below_Product Approval M , required Moment Resistance - Mean 5' 20' 25' 30, 40' 4.4 36.5 38.2 39.7 42.2 n7:,224M4r 2.2 34.4 36.0 37.4 39.8 .4 32.2 33.8 35.1 37.3 .4 30.1 31.6 32.8 34.9 .4 28.0 29.4 30.5 32.4 4.4 25.9 27.1 28.2 30.0 -- --.............. o list ui niomenc Case. Cie systems • For Uplift based tile systems use Method 3. Compare the values for F' with the values for F, If the F'values are greater than or equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: _x L_ x W:=_) -W:_ cos r--- =F,c_ Product Approval F' (Zone 2e:_x L=xW:=J-W: Cos _�=Fa•_ ProduRApproval F' (Zone 2re_xL_zW:= -W; cos r=Fan Product Approvalp (Zone 2r: _x L_=x W:=... j -W: cos r= F,z,_ Product ApproVal F' (Zone 3e:_x L=xW:- _)-W;_Cos r= F,3 Product Approval F' (Zone 3r: _x L_x W:=_)-W:_Cos r=F,3, Product Approval F' Where to Obtain lnf rmatioo Description Symbol Wheretoknd Design Pressure Zones 1, 2e, Zn, 293e, 3r From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height H Job Site Roof Slope B Job Site Aerodynamic Muklplier a Product Approval Restoring Moment due to Gravity Ms Product Approval Attachment Resistance Mf Product Approval Required Moment Resistance Mr Calculated Minimum Attachment Resistance F' Product Approval Required Uplik Resistance F, Calulated Average Tile Weight W Pro ua Approval Tile Dimensions L=length W=width Pr uct Approval All Calculations must be submitted to the building official at the time of pertn h application.