ilding Information
Wind Zane: 146 MPH,
Exposure Category: C
Minimum Building Dimension: 36 ft.
Mean Roof Height: 18 ft.
Risk Category: 11
Property Information
Owner: Michael Zanakis
Address: 8032 Plantation Lakes Dr
Port Saint Lucie. FL 34986
Information
Wind Zone 146 MPH.
Exposure Category: C
Minimum Building Dimension: 36 ft.
Mean Roof Height: 18 ft.
Risk Category: H
Design Pressure Calculations
Opening
Max Positive
Max Negative
Number
Pressure (psf)
Pressure (psf)
26
27.9
-30.3
27
28.5
-31.0
28
28.5
-31.0
29
28.S
-31.0
Prepared in at cordanor u•id r ASCE 7-16. Chaplrr 30. Wind Lruids - Cnn.ptmetm and CI..Idiug. 70i Edition (2020) Florida Building Code.