Loading...
HomeMy WebLinkAboutCOMPONENT & CLADDING WIND LOADSPrepared for White Alumininum Calculations by Seaside Engineers Project: D'Amico Residence Certificate of Authorization No. 32048 Location: 9490 S. Ocean Drive #415 4265 60th Court Jensen Beach, FL Vero Beach, Florida 32967 Project ID:(722) 202‐8008            info@seasideengineers.com Date:  9/10/2021 www.seasideengineers.com Design Information Risk Category II Windspeed 170 mph Exposure D Int. Press. Coef., GCpi(+/‐)0.18 Enclosed a 3.50 feet ID Area  (sqft) Zone Florida  Product  Approval # or  NOA Manufacturer Model 1 9.9 5 20‐0401.11 PGT SH7700A 59.4 ‐108.8 80.0 ‐110.0 2a 9.9 5 20‐0401.11 PGT SH7700A 59.4 ‐108.8 80.0 ‐110.0 2b 0.3 5 20‐0406.03 PGT 1x2.75x0.65 59.4 ‐108.8 170.0 ‐170.0 3a 9.3 5 20‐0401.11 PGT SH7700A 59.4 ‐108.8 80.0 ‐110.0 3b 19.7 5 20‐0401.10 PGT PW7720A 59.4 ‐108.8 90.0 ‐130.0 3c 0.4 5 20‐0406.03 PGT 1x2.75x0.65 59.4 ‐108.8 170.0 ‐170.0 Select the appropriate fastener size and spacing using the pre‐engineered attachment schedule for the Florida Approved Product(s) or NOA used on this job. The contractor is  responsible to ensure the use of the proper material, reinforcement, components, etc. to meet the indicated pressure per the product approval engineering document. The contractor  is responsible to verify the component is in the appropriate zone using the "a" dimension shown above and diagrams shown below. The building pressures are calculated using the  Allowable Stress Design. Contact Seaside Engineers immediately if the substrate at the attachment locations appears to have deterioration, abnormalities, damage, or other conditions  resulting in questionable integrity. Component & Cladding Wind Loads Building Design  Pressure (PSF) Product Design  Pressure (PSF)Opening Description SH Window SH Window Mullion SH Window PW Mullion