Loading...
HomeMy WebLinkAboutDESIGN PRESSURE CALCULATIONSFloridaR' i Door 1125 N. Dixie Hwy Tel. (561.) 848-490a LakeWorth, FL'33460 H��rirly inclwv<n�u�lc�� c�c�en Property Information Building Information Owner: Jean Hazellief Wind Zone: 165 MPH. Address: 7301 San Carlos Dr Exposure Category: C Fort Pierce, FL 34951 Minimum Building Dimension: 35 ft. Mean Roof Height: 10 ft. Risk Category: II Design Pressure Calculations j Opening )L Location Device Device JDevice Positive Max Negative l Ni Zone Width (in) Height (in) Elevation(,) LMax Pressure (ps; Pressure(psf) 1 End 26 26 7 35.6 -- -47.7 2 End 53 50 7 34.2 -44.9 3 j End 53 50 7 34.2 -44.9 4 End 26 25 7 35.6 -47.7 5 End 37 50 7 35.0 -46.5 6 End 37 50 7 35.0 -46.5 Prepared in accordance with: ASCE 7-16, Chapter 30. Wind Loads - Components and Cladding. 7th Edition (2020) Florida Building Code. Page 1 of 1