HomeMy WebLinkAboutLETTER - ARCHITEC DESIGN PRESSURE CALCULATIONS io y Architectonic Inc , St. Lucie County Planning&Development Services Building&Code Regulation Division 2300 Virginia Ave. Fort Pierce, FL 34982 :November 19,2021 RE: 15965 West Park Lane, Fort Pierce, FL 34945 To Whom It May-Concern: Our office has performed design pressure calculations for the above referenced project and herby certify that the proposed garage door is in compliance with the 2020 Florida Building Code, 160 mph wind zone, exposure"C", risk category 111. .From Table 1609.3.1: iV,it= 165mph From Table 1609.6(1): ',12' h x 14'w door, 165 mph +24.3/-27.5 From Table1609.6(2): 15' mean roof height, Exposure C=1.21 I Required Design Pressures: 24.3 X 1.21=29.4 -27.5 X 1.21=-33.2 Product:!anus International Group,LLC,Series 3100,FL#12765.3 Product-Pressures: +31&-41 IZMd ©rt ' a,( 0)& OF Ft �e'speHAy��IyJSsubmi�d ; 4�r ,' AR . I t AR 8 :Architectonic, Inc. it $06 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 46o 4244 FL Reg#AA26003348 1 of 1