Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET17, LL! LLL pR r"- ST. LUGIE ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Roof System Required Sections of the Permit Application Form Attachments Required See List Below Low Slope Application A, B, C 1,2,3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 12,4,5,6,7 Concrete or Clay Tile A, B, D, E 1,2,3,4,5,6,7 Metal Roofs A, B, D 1,2,3,4,5,6.7 Wood Shingles and Shakes A, B, D 1,2,4,5,6,7 Other As Applicable 1,2,3,4,5,6,7— ATTACHMENTS REQUIRED As Applicable): I. Fire Directory Listing Page 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval 5. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form RooflnfoFeb21 Rev Feb 18, 2021 ST. LUCIE WORKS Section A (General Information) Master Permit No. Process No. Contractors Name: !/U I Ce Zara License N C A" 1332-314 (� Job Address lH!%(bH Isla -IFlbre-s pit ror-�- ]2 Crce., Pt ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles ❑Asphaltic Shingles I`letal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance Q4eroofing ❑ Recovering ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) V l A' Steep Sloped Roof Area (SF) 2.rj't7 0 Total (SF) z450 a Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. J �, ST. LUCIE WORKS Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mf values are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable. Method 1'Moment Based Tile Calculations Per RA512T (Zonel: _x2,_= (Zone 2e: _x2,-= (Zone 2n: -x:l-- (Zone 2r: _, x )6-= (Zone3e: -xX-= (Zone 3r: -x)L-= -Mg: -=Mri- -Mg: -=Ma. - -) mg: -=Me, - -)-Mg'-=Me- -Mg:-= Mrs.- -a-Mg: -=Ma,- Product Approval Mi Product Approval Mr Product Approval Mr Product Approval Mf Product Approval Mf Product Approval Mf- Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mf Mr required Moment Resistance Mean Roof Height Roof Slope 15' 20' 2 30' 40' 2:12 34.4 36. 39.7 42.2 3:12 32.2 34.4 36.0 37.4 39.8 4:12 30.4 32.2 33.8 35.1 37.3 5:12 28.4 30.1 31.6 32.8 34.9 6:12 26.4 28.0 29.4 30.5 32.4 7:12 24.4 .9 7.1 28.2 30.0 "Must be used in conjunction with a list of moment se, • For Uplift based tile systems use Method 3. Compare equal to the F, values, for each area of the roof, then the Yle systems values for F' with the values for Fr If the F' values are greater than or attachment method is acceptable. Method alculations Per RAS 12T (Zone 1: x L x W:= ) -W:Fn Product Approval F'(Zone 2e: x L=x W:=) -W= r Product Approval F'. (Zone 2n: x L=x W:=) -W=Fr2" Product Approval F'. (Zone 2r: x L x W:=) -W=Fr2r_ NB11ased Product Approval F'_(Zone 3e: x L= x W:= ) -W=Fr3e Product Approval F'. (Zone 3r: x L= x W:=\ =Fr3r_ Product Approval F'_ Wheret btainl formation Description Where to find Design Pressure tF From applicable table in RAS 127 or by an engineering analysis prepared by PE based on ASCE 7 Mean Roof Height Job Site Roof Slope Job Site Aerodynamic Multiplier a Product Approval Restoring Moment due to Gravity M,. Product Approval Attachment Resistance Mr Product Approval Required Moment Resistance M8 Calculated Minimum Attachment Resistance F' Product Approval Required Uplift Resistance Fr Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W = width Product Approval All calculations must be submitted to the building official at the time of permit application. ST. LUCIE VQRKS Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: Product Approval Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': Zone 1: Zone 2: _Zone 3: Max. Design Pressure, from the specific product approval system: Deck: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Insulation Base Layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing: Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows— ® "oo ' Zone 1:_" oc @ Lap, # Rows _ ® "oo Zone 2:_...." oc @ Lap, # Rows — ® or Zone 3:—" oc @ Lap, # Rows_ ® _° oo ' Number of Fasteners Per Insulation Board: Zone 1':—Zone 1:—Zone 2:—Zone 3:— Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spaci ng or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ST. LUCIE WORKS Section D (Steep Slope Roof System) Roof System Manufacturer: Lt [- Notice of Acceptance Number: kL 4C1 .1 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-5:1' Zone 2e:— 5 7Zone 2n:-=—q-_Zone 2r:' Q/ Zone 3e:- Zone 3r: —mrx Deck Type: 00 h // i�D Type Underlayment Fit7a �q Roof Slope: 3 42 Insulation: Fire Barrier: /'a Ridge Ventilation? Fastener Type & Spacing: ► 1�y� �� 5Gtl1 Nay i5 as Adhesive Type: Type Cap Sheet: Mean Roof Height: n Roof Covering: Type & Size Drip aX� Edge: