HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEET17, LL! LLL pR
r"-
ST. LUGIE
ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET
Florida Building Code 7th Edition (2020)
Based on Section 1525 of the Florida Building Code - Building
INSTRUCTION PAGE
COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING SHEET
APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED
BELOW:
Roof System
Required Sections of
the Permit Application
Form
Attachments Required
See List Below
Low Slope Application
A, B, C
1,2,3,4,5,6,7
Prescriptive BUR-RAS 150
A, B, C
2,4,5,6,7
Asphaltic Shingles
A, B, D
12,4,5,6,7
Concrete or Clay Tile
A, B, D, E
1,2,3,4,5,6,7
Metal Roofs
A, B, D
1,2,3,4,5,6.7
Wood Shingles and
Shakes
A, B, D
1,2,4,5,6,7
Other
As Applicable
1,2,3,4,5,6,7—
ATTACHMENTS REQUIRED As Applicable):
I.
Fire Directory Listing Page
2.
From Product Approval:
Front Page
Specific System Description
Specific System Limitations
General Limitations
Applicable Detail Drawings
3.
Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128
4.
Other Component of Product Approval
5.
Municipal Permit Application
6.
Owners Notification for Roofing Considerations (Reroofing Only)
7.
Any Required Roof Testing/Calculation Documentation
Form RooflnfoFeb21 Rev Feb 18, 2021
ST. LUCIE WORKS
Section A (General Information)
Master Permit No. Process No.
Contractors Name: !/U I Ce Zara License N C A" 1332-314 (�
Job Address lH!%(bH Isla -IFlbre-s pit ror-�- ]2 Crce., Pt
ROOF CATEGORY
❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles
❑Asphaltic Shingles I`letal Panel/Shingles ❑Wood Shingles/Shakes
❑ Prescriptive BUR-RAS 150
ROOF ROOF TYPE.
❑ New roof ❑ Repair ❑ Maintenance Q4eroofing ❑ Recovering
ROOF SYSTEM INFORMATION
Low Slope Roof Area (SF) V l A' Steep Sloped Roof Area (SF) 2.rj't7 0 Total (SF) z450 a
Section B (Roof Plan)
Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains.
Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets.
J �,
ST. LUCIE WORKS
Section E (Tile Calculations)
For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the values from Mr. If the Mf values
are greater than or equal to the Mrvalues, for each area of the roof, then the tile attachment method is acceptable.
Method 1'Moment Based Tile Calculations Per RA512T
(Zonel: _x2,_=
(Zone 2e:
_x2,-=
(Zone 2n:
-x:l--
(Zone 2r:
_, x )6-=
(Zone3e:
-xX-=
(Zone 3r:
-x)L-=
-Mg: -=Mri-
-Mg:
-=Ma. -
-) mg:
-=Me, -
-)-Mg'-=Me-
-Mg:-=
Mrs.-
-a-Mg:
-=Ma,-
Product Approval Mi
Product Approval Mr
Product Approval Mr
Product Approval Mf
Product Approval Mf
Product Approval Mf-
Method 2 "Simplified Tile Calculations Per Table Below"
Required Moment of Resistance (Mr) From Table Below Product Approval Mf
Mr required Moment Resistance
Mean Roof Height Roof Slope
15'
20'
2
30'
40'
2:12
34.4
36.
39.7
42.2
3:12
32.2
34.4
36.0
37.4
39.8
4:12
30.4
32.2
33.8
35.1
37.3
5:12
28.4
30.1
31.6
32.8
34.9
6:12
26.4
28.0
29.4
30.5
32.4
7:12
24.4
.9
7.1
28.2
30.0
"Must be used in conjunction with a list of moment se,
• For Uplift based tile systems use Method 3. Compare
equal to the F, values, for each area of the roof, then the
Yle systems
values for F' with the values for Fr If the F' values are greater than or
attachment method is acceptable.
Method
alculations Per RAS 12T
(Zone 1:
x L
x W:= ) -W:Fn
Product Approval F'(Zone
2e:
x L=x
W:=) -W=
r
Product Approval F'.
(Zone 2n:
x L=x
W:=) -W=Fr2"
Product Approval F'.
(Zone 2r:
x L
x W:=) -W=Fr2r_
NB11ased
Product Approval F'_(Zone
3e:
x L=
x W:= ) -W=Fr3e
Product Approval F'.
(Zone 3r:
x L=
x W:=\
=Fr3r_
Product Approval F'_
Wheret btainl formation
Description
Where to find
Design Pressure
tF
From applicable table in RAS 127 or by an engineering analysis
prepared by PE based on ASCE 7
Mean Roof Height
Job Site
Roof Slope
Job Site
Aerodynamic Multiplier
a
Product Approval
Restoring Moment due to Gravity
M,.
Product Approval
Attachment Resistance
Mr
Product Approval
Required Moment Resistance
M8
Calculated
Minimum Attachment Resistance
F'
Product Approval
Required Uplift Resistance
Fr
Calculated
Average Tile Weight
W
Product Approval
Tile Dimensions
L = length W = width
Product Approval
All calculations must be submitted to the building official at the time of permit application.
ST. LUCIE VQRKS
Section C (Low Slope Roof)
Fill in specific roof assembly components and identify
manufacturer
(If a component is not used, identify as "NA")
System Manufacturer:
Product Approval
Design Wind Pressures, From RAS 128 Or Calculations:
Zone 1': Zone 1: Zone 2: _Zone 3:
Max. Design Pressure, from the specific product approval
system:
Deck:
Gauge Thickness:
Slope:
Anchor/Base Sheet & No. df Ply(s):
Anchor/Base Sheet Fastener/Bonding
Insulation Base Layer:
Base Insultation Size and Thickness:
Base Insulation Fastener/Bonding Material:
Top Insulation Layer:
Top Insulation Size and Thickness:
Top Insulation Fastener/Bonding Material:
Base Sheet(s) & No. of Ply(s):
Base Sheet Fastener/Bonding
Ply Sheet(s)' & No. of Ply(s):
Ply Sheet Fastener/Bonding Material:
Top Ply:
Top Ply Fastener/Bonding Material:
Surfacing:
Fastener Spacing for Anchor/Base Sheet Attachment:
Zone 1':—"
oc @ Lap, # Rows— ® "oo '
Zone 1:_"
oc @ Lap, # Rows _ ® "oo
Zone 2:_...."
oc @ Lap, # Rows — ® or
Zone 3:—"
oc @ Lap, # Rows_ ® _° oo '
Number of Fasteners Per Insulation Board:
Zone 1':—Zone 1:—Zone 2:—Zone 3:—
Illustrate Components Noted and Details as Applicable:
Woodblocking, Gutter, Edge Termination, Stripping,
Flashing, Continuous Cleat, Cant Strip, Base Flashing,
Counterflashing, Coping, Etc..
Indicate: Mean Roof Height, Parapet Height, Height of Base
Flashing, Component Material, Material' Thickness, Fastener
Type, Fastener Spaci ng or Submit Manufacturers Details that
Comply with RAS 111 and Chapter 16..
ST. LUCIE WORKS
Section D (Steep Slope Roof System)
Roof System Manufacturer: Lt [-
Notice of Acceptance Number:
kL 4C1 .1
Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations):
Zone 1:-5:1' Zone 2e:— 5 7Zone 2n:-=—q-_Zone 2r:' Q/ Zone 3e:- Zone 3r: —mrx
Deck Type: 00 h // i�D
Type Underlayment Fit7a �q
Roof Slope:
3 42 Insulation:
Fire Barrier: /'a
Ridge Ventilation? Fastener Type & Spacing: ► 1�y� �� 5Gtl1 Nay i5
as
Adhesive Type:
Type Cap Sheet:
Mean Roof Height: n Roof Covering:
Type & Size Drip aX�
Edge: