Loading...
HomeMy WebLinkAboutduct leakageDuct Leakage Test Report Prescriptive or Performance Method Permit `Job information Builder: DR HORTON Community: CREEKSIDE Lot: 110 Address: 9400 POTOMAC DRIVE Unit: City; FORT PIERCE State: FL Zip: 34945 Duct Leakage rest Results Presciptive Method 0 Performance Method System 1 System 2 1 cfm25 System 3 cfm25 Sum of any additional systems cfm25 Total of all systems rfn,')5 50 2605 0.01 on Total of all systems Fv 1, PASS Testing Company Total Conditioned Square Footage FAIL 0 Prescriptive Method cfm25 (total) To qualify as "substantially teak free" Qn must be less than or equal to 0.04 if air handier unit is Installed. If air handier unit is not installed, Qn Total must be less than or equal to 4.03_ This testing method meets the reaulrements in accordance with Section R403.2.2 D Performance Method cfm25 (out or Total) To qualify as "substantially leak free" Qn must not be greater than the proposed duct leakage Qn specified on Form R405-2014 Leakage Type selected an Form R4052014 (Energy Cale) On specified on Form R4€35-2014 (Energy Catc) Company Name: SUN SEAL LLC Phone:. 321.-41.2-0035 ! hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as seated above, either the Prescriptive Method or Performance Method. [Date of Test: 11 /24/2021 Signature of Tester: Ve,',.. Printed Name of Tester: €]ANIEL MURPHY License/Certification # 5066444 __ Issuing Authority BPI Envelope Leakage (Blower Door Test) R402.4.1.2 Compliance Test Report Permit # Job information Builder: DR HORTON Community: CREEKSIDE Lot: 110 Address: 9400 POTOMAC DRIVE unit: City: FORT PIERCE State: FL Zip: 34945 Air Leakage Test Results Passing results must be T ACH(5I0) or less 1689 x 60 = 22403 4 Method for calculating building volume: CEM(50) Building Volume ACH(50) Q Retrieved from architectural plans r . Code software calculated RS FAIL 0 Field measured and calculated mm When ACH(50) is less than 3, Mechanical k l Ventilation installation must be verified by building department, Certification of Test Results R402.4.1.2 Testing. The building or dwelling unit shall be tested and venfilea as having an air 1eaKa6e I dLe v1 11UL CnCccu i S I Oil w.ru 511 per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or individuals licensed as set forth in Section 489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of the building thermal envelo Testing Company Company Name: SUN SEAL LLC Phone: 321-412-0035 l hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 11 /24/2021 Signature of Tester: I — JL44�K f Tester: DEL MURPHY Printed Name o e License/certification 4510015440 issuing Authority BPI