HomeMy WebLinkAbout2110238-1d Compaction REVISED signedHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
REVISED: PERMIT ADDED
December 20, 2021 KSM JOB # :2110238-1d/BS/jam
CONTRACTOR:TNT Builders of Florida
981 S.W. Biltmore Street
Port St. Lucie, FL 34983
JOB LOCATION:601 North 39th Street
Fort Pierce, Florida
PERMIT #:21040311
Respectfully,
PE # 68366 12/20/21
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
December 20, 2021
Certified Women Owned Business - WBE
To Whom it may concern,
Enclosed, please find the nuclear density test results performed on the Plumbing Trench for the Commercial
Building at the above referenced project.
Should you have any questions, please feel free to contact our office.
Julie E. Keller, P.E. President
Email: tntbuildersllc@comcast.net
Proudly Serving Florida since 1990
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB #:2110238-1d/BS/jam
NUC #456
Nuc Model:MC-1 Elite
Nuc Serial #:31456
601 North 39th Street
Fort Pierce, Florida
Plumbing Trench Backfill
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F)
PERCENT
COMPACTION
1 S.W. Corner 0" - 12"35 103.2 106.6 96.8%
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
Penetrometer readings indicate the
Degree of Compaction Meets
Minimum Requirement
12/20/2021
Disclaimer:Contractor is responsible to maintain the tested
area in the condition that KSM completed the indicated
passed compaction test.KSM is not responsible if the tested
area has been altered from the approved inspected condition.
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
ITEM TESTED:
Soil Description:
TEST LOCATION
OF SAMPLE
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE
10.8%
PE # 68366
106.6
JOB LOCATION:
Gray Sand
CONTRACTOR:TNT Builders of Florida
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
REVISED: PERMIT ADDED December 20, 2021
DATE TESTED:December 13, 2021
In Place Moisture:
PERMIT #:21040311
Email: tntbuildersllc@comcast.net
12.0%
Julie E. Keller, P.E. President
Headquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
DATE TESTED:KSM JOB # :2110238-1d/BS/jam
PERMIT #:21040311
CONTRACTOR:TNT Builders of Florida
JOB LOCATION:601 North 39th Street
Fort Pierce, Florida
Soil Description:
Gray Sand
Proctor Optimum Moisture:
12.0%
Proctor Max. Dry Density: P.C.F.
106.6
Julie E. Keller, P.E. President
PE # 68366 12/20/2021
SOIL COMPACTION REPORT
ASTM D 1557
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Certified Women Owned Business - WBE
Proudly Serving Florida since 1990
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
December 13, 2021
101.0
102.0
103.0
104.0
105.0
106.0
107.0
108.0
7 8 9 10 11 12 13 14 15
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight