HomeMy WebLinkAboutPRODUCT APPROVAL - METAL ROOFINGssional
Regulation
BCIS Home E Log In User Registration Hot Topics j Submit Surcharge Stats & Facts Publications a Contact Us ' BCIS Site Map ! Links ! Search
b
Jr4 � Product Approval
USER: Public User
Product Approval Menu > Product or Application Search > Application List > Application Detail
FL #
FL27408-R1
Application Type
Revision
Code Version
2020
Application Status
Approved
Comments
Archived
Product Manufacturer Boral Roofing / Boral Steel
Address/Phone/Email 3093 A Industry Street
Oceanside, CA 92054
(760) 435-9842
RobinAnderson@boral.com
Authorized Signature Robin Anderson
RobinAnderson@boral.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Zachary R. Priest
Evaluation Report
Florida License PE-74021
Quality Assurance Entity QAI Laboratories
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Steven M. Urich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL27408 R1 COI BOR18002.1 2020 FBC Eval Metal Panels final pdf
Standard
Year
ASTM B 117
2016
ASTM G 155
2013
TAS 100
1995
TAS 110
2000
TAS 125
2003
UL 1897
2012
UL 580
2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
of Products
Method 1 Option D
10/02/2020
12/16/2020
10/12/2020
12/21/2020
27408.1 Pine Crest Shake, Cottage Shingle, Min. 26 ga. stone -coated steel roof panels
Pacific Tile, Barrel Vault Tile and
Granite Ridge Shingle
Limits of Use Installation Instructions
Approved for use in HVHZ: Yes FL27408 R1 II BOR18002.1 2020 FBC Eval Metal Panels
Approved for use outside HVHZ: Yes final .pdf
Impact Resistant: N/A Verified By: Zachary R. Priest PE-74021
Design Pressure: +0/-150 Created by Independent Third Party: Yes
Other: See evaluation report for limits of use. Evaluation Reports
FL27408 R1 AE BOR18002.1 2020 FBC Eval Metal Panels
final .pdf
Created by Independent Third Party: Yes
ME
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487,1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
Rid
Credit it Gard
Safe
CREEK
TECHNICAL SERVICES, LLC
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813) 480-3421
EVALUATION REPORT FLORIDA BUILDING CODE, 7T" EDITION (2020)
Manufacturer: BORAL ROOFING, LLC Issued December 15, 2020
3093 "A" Industry Street
Oceanside, CA 92054
(760)435-9842
www.boralroof.com
Manufacturing: Oceanside, CA
Quality Assurance: QAI Laboratories (QUA7628)
SCOPE
Category: Roofing
Subcategory: Metal Roofing
Code Edition: Florida Building Code, 7cn Edition (2020) including High -Velocity Hurricane Zones (HVHZ)
Code Sections: 1504.3.1, 1504.3.2, 1518.9, 1523.6.5.2.4
Properties: Wind Resistance, Physical Properties
PRODUCT DESCRIPTION
Pine Crest Shake
Profile: 16 in. x 52 in. panel; leading edge is turned down 1 in. and back edge is bent up and horizontally
back 1.5 in. Panel side laps are 2 in.
Description: Preformed, fastened, stoned -coated steel panels with No. 14 granule
Material: Min. 26 ga. ASTM A792 AZ50; Fy = min. 40 ksi; Shall conform with FBC Section 1507.4.3
Cottage Shinale
Profile: 14 in. x 51 in. panel; leading edge is turned down 1 in. and back edge is bent up and horizontally
back 1.5 in. Panel side laps are 2 in.
Description: Preformed, fastened, stoned -coated steel panels with No. 14 granule
Material: Min. 26 ga. ASTM A792 AZ50; Fy = min. 40 ksi; Shall conform with FBC Section 1507.4.3
BOR18002.1 FL27408-RI Page 1 of 14
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Metal Shingles
TECHNICAL. SERVICES, LLC
Pacific Tile
Profile: 16 in. x 52 in. panel; leading edge is turned down 1 in. and back edge is bent up and horizontally
back 1.5 in. Panel side laps are 2 in.
Description: Preformed, fastened, stoned -coated steel panels with No. 14 granule
Material: Min. 26 ga. ASTM A792 AZ50; Fy = min. 40 ksi; Shall conform with FBC Section 1507.4.3
Barrel Vault Tile
Profile: 13-1/2 in. to 14 in. x 45-1/8 in. panel
Description: Preformed, fastened, stoned -coated steel panels with No. 14 granule
Material: Min. 26 ga. ASTM A792 AZ50; Fy = min. 40 ksi; Shall conform with FBC Section 1507.4.3
R
Granite Ridge Shingle
Profile: Metal shingle with Pittsburgh lock at head lap; 13-11/16 in. x 44 in. coverage
Description: Preformed, fastened, stoned -coated steel panels with No. 14 granule
Material: Min. 26 ga. ASTM A792 AZ50; Fy = min. 40 ksi; Shall conform with FBC Section 1507.4.3
Sidelap width 21116"
BOR18002.1 FL27408-R1 Page 2 of 14
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL, SERVICES, LLC
INSTALLATION
Note - Refer to the APPROVED ASSEMBLIES section of
assemblies.
BORAL ROOFING LLC
Metal Shingles
report for the maximum design pressures of the approved
Unless otherwise specified in this report the following installation details shall be met for the named products:
Direct -to -Deck Installation Patterns
Pine Crest Shake - Direct -to -Deck Pattern 1 Pine Crest Shake - Direct -to -Deck Pattern 2
Cottage Shingle - Direct -to -Deck Pattern 1
Pacific Tile - Direct -to -Deck Pattern 1
Cottage Shingle - Direct -to -Deck Pattern 2
Pacific Tile - Direct -to -Deck Pattern 2
BOR18002.1 FL27408-RI Page 3 of 14
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL. SERVICES, LLC
Direct -to -Deck Installation Patterns
Barrel Vault - Direct -to -Deck Pattern 1
Over Batten Installation Patterns
BORAL ROOFING LLC
Metal Shingles
Barrel Vault - Direct -to -Deck Pattern 2
Batten Spacing ----
Panel Panel.._..,
Fastener wood Battens Fastener
z-- Roof Panel
Underlayment —./
Roof
Pine Crest Shake - Batten Pattern 1
Pacific Tile - Batten Pattern 1
1\
Barrel Vault - Batten Pattern 1
13-112' -14-
Wood Battens
Pine Crest Shake - Batten Pattern 2
Pacific Tile - Batten Pattern 2
Barrel Vault - Batten Pattern 2
BOR18002.1 FL27408-R1 Page 4 of 14
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Granite Ridge Installation Patterns
Granite Ridge - Direct -to -Deck
46 1116"
BORAL ROOFING LLC
Metal Shingles
BOR18002.1 FL27408-R1 Page 5 of 14
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
u CREEK
TECHNICAL SERVICES, LLC
APPROVED ASSEMBLIES
BORAL ROOFING LLC
Metal Shingles
Direct -to -Deck Pattern
1
Slope:
3:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck:
max. 24 in, span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment:
shall be ASTM D 226, Type II installed in accordance with Section 1518.2 or any approved
underlayment for use in the HVHZ.
26 ga. Metal Panel installed as shown in INSTALLATION with four (4) #10-16 x 2-1/2 in.
HWH corrosion resistant wood screws through the vertical leg at the headlap beginning at
Attachment:
the center of the side lap and four (4) #10-16 x 2-1/12 in. HWH corrosion resistant wood
screws through the horizontal leg at the back of panel beginning at the side lap. Fasteners
shall penetrate through the deck a minimum 3/8" and shall comply with section 1506.6 and
1507.4.4.
Maximum Design
-52.5 psf
Pressures:
Pressure calculated using 2.1 margin of safety
Maximum Mean Roof Heights for Gable/Hip Roofs
Slopes 2:12 —12:12
Exposure
9Basic Wind Speed (mph)
<120 130 140 150 1 160 170 180 190 200
Zone 1 — Field
B
60 ft
60 ft
60 ft
52 ft
33 ft
21 ft
NA
NA
NA
C
60 ft
49 ft
24 ft
NA
NA
NA
NA
NA
NA
D
52 ft
20 ft
NA
NA
NA
NA
NA
NA
NA
Zone 2 (includes 2e, 2n, and 2r) — Perimeter
B
60 ft
37 ft
22 ft
NA
NA
NA
NA
NA
NA
C
17ft
NA
NA
NA
NA
NA
NA
NA
NA
D
NA
NA
NA
NA
NA
NA
NA
NA
NA
Zone 3 (includes 3e and 3r) — Corner
B
36 ft
20 ft
NA
NA
NA
NA
NA NA
NA
C
NA
NA
NA
NA
NA
NA
NA NA
NA
D
NA
NA
NA
NA
NA
NA
NA NA
NA
Notes: 1) Exposure category for the structure location shall be as defined in the International Building Code 2) Limitations are
based on the exposed area of 10ft2 or less 3) Topographic factors such as escarpments or hills are not included in the above
assessment 4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Kd = 0.85 7) Projects with mean roof
heights of greater than 60 ft shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and
locales of Zone 1, 2, and 3 9) V,,,t is shown in the above table. Design pressures are calculated using Vasd = V,,,tA.6.
BOR18002.1 FL27408-Rl Page 6 of 14
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
u CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Metal Shingles
Direct -to -Deck Pattern
2
Slope:
3:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck:
max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment:
shall be ASTM D 226, Type II installed in accordance with Section 1518.2 or any approved
underlayment for use in the HVHZ.
26 ga. Metal Panel installed as shown in INSTALLATION with eight (8) #10-16 x 2-1/2 in.
HWH corrosion resistant wood screws through the vertical leg at the headlap beginning at
Attachment:
the center of the side lap and eight (8) #10-16 x 2-1/2 in. HWH corrosion resistant wood
screws through the horizontal leg at the back of panel beginning at the side lap. Fasteners
shall penetrate through the deck a minimum 3/8" and shall comply with section 1506.6 and
1507.4.4.
Maximum Design
-127.5 psf
Pressures:
Pressure calculated using 2:1 margin of safety
Maximum Mean Roof Heights for Gable/Hip Roofs
Slopes 2:12 —12:12
Exposure
9Basic Wind Speed (mph)
<_12D
130
140
150
160
170 180
190
200
Zone 1 — Field
B
60 ft
60ft
60 ft
60 ft
60 ft
60ft
60 ft
60 ft
60 ft
C
60ft
60ft
60ft
60ft
60ft
60ft
60ft
60ft
55ft
D
60ft
60ft
60ft
60ft
60ft
60ft
60ft
43ft
1 24 ft
Zone 2 (includes 2e, 2n, and 2r) — Perimeter
B
60 ft
60 ft
60 ft
60ft
60 ft
60 ft
60 ft
59 ft
41 ft
C
60ft
60ft
60ft
60ft
60ft
43ft
25ft
15ft
NA
D
60 ft
60 ft
60 ft
60 ft
36 ft
17 ft
NA
NA
NA
Zone 3 (includes 3e and 3r) — Corner
B
60ft
60ft
60ft
60ft
60ft
60ft
47ft
32ft
22ft
C
60 ft
60 ft
60 ft
60 ft
34 ft
19 ft
NA
NA
NA
D
60 ft
60ft
60 ft
28 ft
NA
NA
NA
NA
NA
Notes: 1) Exposure category for the structure location shall be as defined in the International Building Code 2) Limitations are
based on the exposed area of 10ft2 or less 3) Topographic factors such as escarpments or hills are not included in the above
assessment 4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Kd = 0.85 7) Projects with mean roof
heights of greater than 60 It shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and
locales of Zone 1, 2, and 3 9 V,,,t is shown in the above table. Design pressures are calculated using Vasd = VultA.6.
BOR18002.1 FL27408-Rl Page 7 of 14
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Metal Shingles
Batten Pattern 't
Slope:
3:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck:
max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment:
shall be ASTM D 226, Type II installed in accordance with Section 1518.2 or any approved
underayment for use in the HVHZ.
Nominal No. 2 2x2 SYP wood battens spaced 14-1/2 in. o.c. and oriented perpendicular to
Battens:
the wood joists. Battens secured with one (1) #8-11 x 3 in. bugle head wood screw at
each rafter/truss intersection. In the Non-HVHZ, If counter batten/batten installation is
used, refer to COUNTER BATTEN/BATTEN INSTALLATION section of this report.
26 ga. Metal Panel installed as shown in INSTALLATION with five (5) #10-16 x 2 in. HWH
Attachment:
corrosion resistant wood screws (four (4) fasteners for Barrel Vault) through the vertical leg
at the headlap beginning at the center of the side lap. Fasteners shall comply with section
1506.6 and 1507.4.4.
Maximum Design
-82.5 psf
Pressures:
Pressure calculated using 2:1 margin of safety
Maximum Mean Roof Heights for Gable/Hip Roofs
Slopes 2:12 — 6,1:12
Exposure
9Basic Wind Speed (mph)
5120 130
140 150 1 160
170 180 190 200
Zone 1 — Field
B
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
48ft
33ft
C
60 ft
60 ft
60 ft
60 ft
59 ft
33 ft
19 ft
NA
NA
D
60 ft
60 ft
60 ft
54 ft
25 ft
NA
NA
NA
NA
Zone 2 (includes 2e, 2n, and 2r) — Perimeter
B
60ft
60 ft
60 ft
60 ft
42ft
28ft
18ft
NA
NA
C
60 ft
60 ft
34 ft
18 ft
NA
NA
NA
NA
NA
D
60 ft
32 ft
NA
NA
NA
NA
NA
NA
NA
Zone 3 (includes 3e and 3r) — Corner
B
60 ft
60 ft
59 ft
36 ft
23 ft
15 ft
NA
NA
NA
C
60 ft
31 ft
15 ft
NA
NA
NA
NA
NA
NA
D
29ft
NA
NA
NA
NA
NA
NA
NA
NA
Notes: 1) Exposure category for the structure location shall be as defined in the International Building Code 2) Limitations are
based on the exposed area of 10ft2 or less 3) Topographic factors such as escarpments or hills are not included in the above
assessment 4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Ka = 0.85 7) Projects with mean roof
heights of greater than 60 ft shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and
locales of Zone 1, 2, and 3 9 V,,,t is shown in the above table. Design pressures are calculated usin Vasa = Vu,tg0.6.
BOR18002.1 FL27408-Rl Page 8 of 14
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Metal Shingles
Batten Pattern Z
Slope:
3:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck:
max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment:
shall be ASTM D 226, Type II installed in accordance with Section 1518.2 or any approved
underlayment for use in the HVHZ.
Nominal No. 2 2x2 SYP wood battens spaced 14-1/2 in. o.c. and oriented perpendicular to
Battens:
the wood joists. Battens secured with one (1) #8-11 x 3 in. bugle head wood screw at
each rafter/truss intersection. In the Non-HVHZ, If counter batten/batten installation is
used, referto COUNTER BATTEN/BATTEN INSTALLATION section of this report.
26 ga. Metal Panel installed as shown in INSTALLATION with ten (10) #10-16 x 2 in. HWH
Attachment:
corrosion resistant wood screws (eight (8) fasteners for Barrel Vault) through the vertical
leg at the headlap beginning at the center of the side lap. Fasteners shall comply with
section 1506.6 and 1507.4.4.
Maximum Design
-150 psf
Pressures:
Pressure calculated using 2:1 margin of safety
Maximum Mean Roof Heights for Gable/Hip Roofs
Slopes 2:12 — 6.1:12
Exposure
9Basic Wind Speed (mph)
<120 130 140
150
1 160
170
180
190
200"
Zone 1 — Field
B
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
1 60 ft
C
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
D
60 ft
60ft
60 ft
60 ft
60 ft
60 ft 1
60 ft
60 ft
60 ft
Zone 2 (includes 2e, 2n, and 2r) - Perimeter
B
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
C
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
54ft
32ft
20ft
D
60 ft
60 ft
60 ft
60 ft
60 ft
45 ft
23 ft
NA
NA
Zone', 3 (includes 3e and 3r) — Corner
B
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
57ft
39ft
C
60 ft
60 ft
60 ft
60 ft
60 ft
41 ft
24 ft
NA
NA
D
60 ft
60 ft
60 ft
60 ft
33 ft
16 ft
NA
NA
NA
Notes: 1) Exposure category for the structure location shall be as defined in the International Building Code 2) Limitations are
based on the exposed area of 10ft2 or less 3) Topographic factors such as escarpments or hills are not included in the above
assessment 4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Kd = 0.86 7) Projects with mean roof
heights of greater than 60 ft shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and
locales of Zone 1, 2, and 3 9 V n is shown in the above table. Design pressures are calculated using Vag = V ,t�0.6.
BOR18002.1 FL27408-Rl Page 9 of 14
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
BORAL ROOFING LLC
Metal Shingles
Granite Ridge Direct -to -Deck
Slope:
4:12 or greater
Solid or closely fitted min. 15/32 in. plywood sheathing for new and existing construction at
Roof Deck:
max. 24 in. span; In the HVHZ, new construction shall be min. 19/32 in. plywood at max.
24 in. span; Designed by others in accordance with FBC requirements.
Installed in accordance with FBC requirements. In the HVHZ, the minimum underlayment
Underlayment:
shall be ASTM D 226, Type 11 installed in accordance with Section 1518.2 or any approved
underlayment for use in the HVHZ.
26 ga. Granite Ridge installed with seven (7) #9-15 x 1-1/2 in. HWH corrosion resistance
wood screws along back flange of panel as shown below (max. 6-1/4 in. o.c. fastener
Attachment:
spacing). Side laps should be staggered a minimum of 9 inches. Fasteners shall
penetrate through the deck a minimum 3/8" and shall comply with section 1506.6 and
1507.4.4.
Maximum Design
-110 psf
Pressures:
Pressure calculated using 2:1 margin of safety per 1504.9
Maximum Mean Roof Heights for Gable/Hip Roofs
Slopes 2:12 — 6.1:12 and >6.1 — 12:12 (Gable Roofs only)
Exposure
9Basic Wind Speed (mph)
5120 130 140 1 150
160 170 180 190 200
Zone 1 — Field
B
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
C
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
1 45 ft
27 ft
D
60 ft
60 It
66 ft
60 ft
60 ft
60 ft
34 ft
18 ft
NA
Zone 2 (includes 2e, 2n, and 2r) — Perimeter
B
60 ft
60 ft
60 ft
60 ft
60 ft
60 ft
51 ft
35 ft
24 ft
C
60 ft
60 ft
60 ft
60 ft
38 ft
21 ft
NA
NA
NA
D
60 ft
60 ft
60 ft
32 ft
15 ft
NA
NA
NA
NA
Zone, 3 (includes 3e and 3r) — Corner
B
60 ft
60 ft
60 ft
60 ft
160ft
42ft
28ft
19ft
NA
C
60 ft
60 ft
60 ft
31 ft
1 16 ft
NA
NA
NA
NA
D
60 ft
60 It
26 ft
NA J
NA J
NA
NA
NA
NA
Notes: 1) Exposure category for the structure location shall be as defined in the Florida Building Code 2) Limitations are based
on the exposed area of 1Oft or less 3) Topographic factors such as escarpments or hills are not included in the above assessment
4) Applicable for Enclosed Buildings without overhangs 5) NA = "Not Allowed" 6) Kd = 0.85 7) Projects with mean roof heights of
greater than 60 ft shall be evaluated by a licensed design professional 8) See page 13 for details for dimensions and locales of
Zone 1, 2, and 3 9) V,,,t is shown in the above table. Design pressures are calculated using Vend = VuftA.6 per 1609.3.1.
BOR18002.1
FL27408-RI
10of14
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK BORAL ROOFING LLC
Metal Shingles
TECHNICAL SERVICES, LLG
BATTEN/COUNTER BATTEN INSTALLATION (NON-HVHZ ONLY)
The following tables provide requirements for batten/counter batten installations based on design wind load
requirements as defined in Chapter 16 of the FBC. Counter battens shall be minimum No.2 SPF 1x4 dimensional
lumber having the minimum specific gravity specified in the tables below. Battens shall be minimum No. 2 SPF 2x2
dimensional lumber having the minimum specific gravity specified in the tables below.
Batten and Counter Batten Spacing and Fastener Requirement for Reroofing with Counterbatten and Rafter of Specific Gravity >_ 0.36
Roof
T e and
Slope
Ult.
Type
Gable
Roof
Slope
3:12
to 12:12
Wind
Hip
Roof
Slope
6.1:12
to 12:12
Hip
Roof
Slope
3:12 to
6.1:12
Speed
(mph)
Zone
1
Zone
2
Zone
3
Zone
1
Zone
2 8, 3
Ex osure
B
C
B
C
B
C
B
C
B
C
s100
Fastener'
Batten
16d
2
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
1 #8
16d
2
2
2
3
2
3
2
3
2
3
2
2
1
2
1
2
2
2
Counterbatten = 1.25" 3
14
14
14
14
10
14
10
14
7
14
7
14
14
14
14
14
10
14
10
Counterbatten = 1.00" 3
10
14
10
14
7
10
7
10
7
10
7
10
14
14
14
14
7
14
10
Counterbatten = 0.75" 3
10
14
10
14
-4
-7
4
7
4
7
4
7
10
14
10
14
7
10
7
110
Batten
2
2
2
2
3
2
3
2
4
3
4
3
2
2
2
2
3
2
3
Counterbatten = 1.25,,)3
10
14
10
14
7
14
7
14
7
10
7
10
14
14
14
14
10
14
10
Counterbatten = 1.00")'
10
14
10
14
7
10
7
10
4
7
4
7
10
14
10
14
7
10
7
Counterbatten = 0.75" 3
7
10
7
10
4
7
4
7
4
4
4
4
7
10
7
10
4
7
120
Batten
3
2
3
2
4
3
4
3
4
3
-4
-3
2
2
-2
-2
3
-2
4
-3
Counterbatten = 1.25" 3
10
14
10
14
7
10
7
10
4
10
4
10
10
14
10
14
7
14
7
Counterbatten = 1.00" °
7
10
7
10
4
7
4
7
4
7
4
7
10
14
10
14
4
10
7
Counterbatten = 0.75" °
4
10
4
10
4
4
4
4
4
4
4
4
7
10
7
10
4
130
Batten2
3
2
3
2
4
3
4
3
5
3
5
3
3
2
3
2
4
7
3
4
4
Counterbatten = 1.25" 3
10
14
10
14
4
10
4
10
4
7
4
7
10
14
10
14
7
10
7
Counterbatten = 1.00" 3
7
10
7
10
4
7
4
7
4
4
4
4
7
10
7
10
4
Counterbatten = 0.75" 3
4
1
4
7
4
4
4
4
NA
4
NA
4
4
7
4
7
4
7
4
4
4
140
Batten
3
2
3-T
2
5
3
5
3
5
4
5
4
3
2
3
2
4
3
4
Counterbatten = 1.25")3
7
14
7
14
4
10
4
10
4
7
4
7
7
14
7
14
4
Counterbatten = 1.00" 3
4
7
4
7
4
4
4
4
NA
4
NA
4
7
10
7
10
4
10
7
4
Counterbatten = 0.75" 3
4
7
4
7
NA
4
NA
4
NA
4
NA
4
4
7
4
7
NA
4
4
4
150
Batten2
4
3
4
3
5
4
5
4
6
4
6
4
3
3
3
3
5
3
5
Counterbatten = 1.25" 3
7
10
7
10
4
7
4
7
4
7
4
7
7
14
7
14
4
10
4
Counterbatten = 1.00" 3
4
1
4
1
4
4
4
4
NA
4
NA
4
4
7
4
7
4
Counterbatten = 0.75" 3
4
4
4
4
NA
4
NA
4
NA
NA
NA
NA
4
7
4
7
NA
4
4
4
NA
160
Batten
4
3
4
3
6
4
6
4
NA
5
NA
5
4
3
4
3
5
4
5
Counterbatten = 1.25" 3
4
10
4
10
4
7
4
7
NA
4
NA
4
7
10
7
10
4
7
Counterbatten = 1.00" 3
4
7
4
7
NA
4
NA
4
NA
4
NA
4
4
7
4
7
NA
4
4
Counterbatten = 075" 3
NA
4
NA
4
NA
NA
NA
NA
NA
NA
NA
NA
4
4
4
4
NA
4
4
NA
170
Batten
5
3
5
3
NA
5
NA
5
NA
NA
NA
NA
4
3
4
3
6
4
6
Counterbatten (p = 1.25" 3
4
10
4
10
4
4
4
4
NA
4
NA
4
4
10
4
10
4
7
Counterbatten = 1.00")3
4 1
4
4
4
NA
4
NA
4
NA
NA
NA
NA
4
7
4
7
NA
4
4
NA
Counterbatten = 0.75" s
NA
4
NA
4
NA
NA
NA
NA
NA
NA
NA
NA
NA
4
NA
4
NA
NA
180
BattenNA
5
4
5
4
NA
5
NA
5
NA
NA
NA
NA
5
3
5
3
NA
5
6
Counterbatten = 1.25" 3
4
7
4
7
NA
4
NA
4
NA
4
NA
4
4
7
4
7
NA
7
4
Counterbatten = 1.00 3
4
4
4
4
NA
4
NA
4
NA
NA
NA
NA
4
4
4
4
NA
4
NA
Counterbatten = 0.75" 3
NA
4
NA
4
NA
NA
NA
NA I
NA I
NA
NA
NA
NA
4
NA
4
NA
NA
NA
Notps' 11 Tha haftwn
anti
r—rotor
ti—tton
c���,...,....
,.4...0
- ----____.. _.._ ___... . , . ., ,a --mil ununi ivu A 3-5-inch ring shank nails and #8 x 3-inch wood screws
2) For batten to counter batten attachment, the number of fasteners at each intersection are shown for each wind load
condition
3) For counter batten to rafter attachment, the fastener spacings along each counter batten are shown for each wind load
condition. The counter batten fastener shall penetrate into the rafter a minimum distance (p) as shown on the table
4) NA = not applicable
BOR18002.1 FL27408-R1 Page 11 of 14
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
#8
2
14
14
10
2
14
7
2
14
7
3
1C
3
10
7
10
4
NA
CREEK BORAL ROOFING LLC
Metal Shingles
TECHNICAL SERVICES, LLC
Batten and Counter Batten Spacing and Fastener Requirement for Reroofing with Counterbatten and Rafter of Specific Gravity z 0.5
RoofType and Slo e
Ult.
Type
Gable Roof Slope 3:12 to 12:12
Wind
Hip Roof Sloe 6.1:12 to 12:12
Hip Roof Slope 3:12 to 6.1:12
Speed
(mph)
Zone 1
Zone 2
Zone 3
Zone 1
Zone 2& 3
Exposure
B
C
B
C
B
C
B
C
B
C
Fastener'
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
16d
#8
s100
Batten
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Counterbatten = 1.25" 3
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00,,3
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
Counterbatten ( = 0.75")3
14
14
14
14
10
14
10
14
10
14
10
14
14
14
14
14
14
14
14
14
110
Batten
2
1
2
1
2
1
2
1
2
2
2
2
2
1
2
1
2
1
2
1
Counterbatten = 1.25" 3
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00" 3
14
14
14
14
14
14
14
—1-0-1-4-7
14
10
14
10
14
14
14
14
14
14
14
14
14
Counterbatten = 0.75" 3
14
14
14
14
10
14
10
7
10
14
14
14
14
10
14
10
14
120
Batten2
2
1
2
1
2
2
2
2
2
2
2
2
2
1
2
1
2
1
2
1
Counterbatten = 1.25" 3
14
14
14
14
14
14
14
14
10
14
10
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00" "
14
14
14
14
10
14
10
14
10
14
10
14
14
14
14
14
10
14
14
14
Counterbatten = 0.75" °
10
14
10
14
7
10
7
10
7
10
7
10
14
14
14
14
10
14
10
14
i30
Batten2
2
1
2
1
2
2
2
2
3
2
3
2
2
1
2
1
2
2
2
2
Counterbatten = 1.25" 3
14
14
14
14
10
14
10
14
10
14
10
14
14
14
14
14
14
14
14
14
Counterbatten = 1.00,,3
14
14
14
14
10
14
10
14
7
10
7
10
14
14
14
14
10
14
10
14
Counterbatten = 0.75" 3
10
14
10
14
7
10
7
10
4
7
4
7
10
14
10
14
7
10
140
Batten
2
2
2
2
3
2
3
2
3
2
3
2
2
1
2
1
2
2
7
2
10
2
Counterbatten = 1.25,,3
14
14
14
14
10
14
10
14
—To
7
14
7
14
14
14
14
14
10
14
10
14
Counterbatten = 1.00" 3
10
14
10
14
7
10
7
--7
10
7
10
14
14
14
14
7
14
10
14
Counterbatten = 0.75" 3
10
14
10
14
7
7
7
7
4
7
4
7
10
14
10
14
7
10
150
Batten2
2
2
2
2
3
2
3
2
3
3
3
3
—2
—2
2
2
3
2
7
3
10
2
Counterbatten = 1.25,,3
14
14
14
14
10
14
10
14
7
14
7
14
14
14
14
14
10
14
10
14
Counterbatten = 1.00" 3
10
14
10
14
7
10
7
10
4
7
4
7
10
14
10
14
7
10
7
10
Counterbatten = 0.75" 3
7
10
7
10
4
7
4
7
4
7
4
7
7
10
7
10
4
160
Batten
2
2
2
2
3
2
3
2
4
3
4
3
2
2
2
2
3
7
2
4
3
7
2
Counterbatten = 1.25" 3
10
14
10
14
7
14
7
14
7
10
7
10
14
14
14
14
7
14
10
14
Counterbatten = 1.00" 3
10
14
10
14
7
10
7
10
4
7
4
7
10
14
10
14
7
10
7
10
Counterbatten = 0.75" 3
7
10
7
10
4
7
4
7
4
4
4
4
7
10
7
10
4
170
Batten
3
2
3
2
4
3
4
3
4
3
4
3
2
2
2
2
3
7
2
4
3
7
2
Counterbatten p = 1.25,,3
10
14
10
14
7
10
7
10
4
10
4
10
10
14
10
14
7
14
7
14
Counterbatten = 1.00,,3
7
10
7
10
4
7
4
7
4
7
4
7
10
14
10
14
4
10
7
Counterbatten = 0.75^ 3
4
7
4
7
4
4
4
4
4
4
4
4
7
10
7
10
4
10
180
Batten
3
2
3
2
4
3
4
3
5
3
5
3
3
2
3
2
4
7
3
4
3
7
3
Counterbatten = 1.25" 3
10
14 1
10 1
14
7
10
7ff4N
10
4
10
10
14
16
14
7
10
7
10
Counterbatten = 1.00,,3
7
10
7
10
4
7
4
4
4
4
7
10
7
10
Counterbatten = 0.75" 3
4
7
4
7
4
4
4A
4
NA
4
4
7
4
7
4
7
Notes: 11 ThP hattr
n anti
nni mtnr
h.++
-F—fi
-
. .._
4
7
4
4
4
4
------------...--'-..-.----.•�• •••............ .v.a n,�„�-nwu imv wicuin iianb dim ffo x3-incn WOoa screws
2) For batten to counter batten attachment, the number of fasteners at each intersection are shown for each wind load
condition
3) For counter batten to rafter attachment, the fastener spacings along each counter batten are shown for each wind load
condition. The counter batten fastener shall penetrate into the rafter a minimum distance (p) as shown on the table
4) NA = not applicable
BOR18002.1 FL27408-R1 Page 12 of 14
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
Ml-lm
BORAL ROOFING LLC
Metal Shingles
Hip \a
3 2 3 a
2 1 2 2 1 2
3 2 3 a
Dimension "a" shall be 10% of the least horizontal dimension or (0.4 x Mean Roof Height), whichever is smaller, but
not less than either 4% of the least horizontal dimension or aft.
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. The roof deck and the roof deck attachment information are provided based on testing. FBC requirements
for the rational design of the roof deck, including the attachment, are not within the scope of this
evaluation.
3. Reroofing shall be in accordance with FBC Section 1511 outside the HVHZ or Section 1521 within the
HVHZ.
4. Installation of the evaluated products shall comply with this report, the FBC and RAS 133 in the HVHZ, and
the manufacturer's published application instructions. Where discrepancies exist between these sources,
the more restrictive and FBC compliant installation detail shall prevail.
5. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61 G20-3.
BOR18002.1
FL27408-R1
13of14
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
GD E E �j BORAL ROOFING LLC
j� j1 Metal Shingles
TECHNICAL SERVICES, LLC
REFERENCES
Entity
Report No.
Standard
Year
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01A
ASTM B 117
2016
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01B
ASTM G 155
2013
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01C
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01 D
UL 580
2006
UL1897
2012
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01E
UL 580
2006
UL1897
2012
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01F
ASTM E 8
PRI Construction Materials Technologies (TST5878)
BORR-099-02-01 G
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
GRT-007-02-01
ASTM B 117
2016
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
GRT-008-02-01
ASTM G 155
2013
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
GRT-022-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
GRT-026-02-01
UL 580
2006
UL1897
2012
TAS 125
2003
CREEK Technical Services, LLC
Anchorage
ASCE 7
2016
Calculations
ANSUAWC NDS
2018
PRI Construction Materials Technologies (TST5878)
BORR-015-02-01
ASCE 7
2016
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 7"' Edition (2020) including High -Velocity Hurricane Zones (HVHZ) as evidenced in the referenced documents
submitted by the named manufacturer.
00RYI,R11��f`�,
���`G�,P •E
NSF•..
No 74021
STATE OF <UN At -
CERTIFICATION OF INDEPENDENCE
2020.12.15
14:38:23
05'00'
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
BOR18002.1
END OF REPORT
FL27408-Rl
14 of 14
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.