Loading...
HomeMy WebLinkAboutROOFING PERMIT INFORMATION SHEETST. LUCIE 1 ST LUCIE COUNTY ROOFING PERMIT INFORMATION SHEET Florida Building Code 7th Edition (2020) Based on Section 1525 of the Florida Building Code - Building INSTRUCTION PAGE COMPLETE THE NECESSARY SECTIONS OF THE UNIFORM ROOFING S�EET APPLICATION FORM AND ATTACH THE REQUIRED DOCUMENTS AS NOTED BELOW: Required Sections of Attachments Required Roof System the Permit Application See List Below Form Low Slope Application A, B, C 1,Z3,4,5,6,7 Prescriptive BUR-RAS 150 A, B, C 2,4,5,6,7 Asphaltic Shingles A, B, D 12,4,5,6.7 'Concrete or Clay Tiie A, B, D, E 1,2,3,4,5,6,7 Metal Roofs - — - A, B, D Wood Shingles and A, B. D 1.2.4,5 8,7 Shakes Other As Applicable ATTACHMENTS REQUIRED As Appiicable): 1. Fire Directory Listing Page i - 2. From Product Approval: Front Page Specific System Description Specific System Limitations General Limitations Applicable Detail Drawings 3. Design Calculations per Chapter 16, or if applicable, RAS 127 or RAS 128 4. Other Component of Product Approval S. Municipal Permit Application 6. Owners Notification for Roofing Considerations (Reroofing Only) 7. Any Required Roof Testing/Calculation Documentation Form Rooflnf❑Feb21 Rev Feb 18.2021 Section A (General Information) Master Permit No. Process No. Contractors Name: f��—�Q Q'f' License k� Job Addres ROOF CATEGORY ❑ Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive ❑ Asphaltic Shingles )4Metal Panel/Shingles Mood Shingles/Sha ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance „kReroofing ❑Re�, . ROOF SYSTEM INFORMATION Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) _ To Section B (Roof Plan) Sketch Roof Plan: illustrate all levels and sections, roof drains, scuppers, overflow scuppers and erflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and locat n of parapets. ST. LUCIE Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, Identify as "NA") System Manufacturer: Product Approval Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': _ Zone 1: _ Zone 2: _Zone 3: _ Max. Design Pressure, from the specific product approval system: Deck: Gauge Thickness: Slope: Anchor/Base Sheet & No. df Ply(s): Anchor/Base Sheet Fastener/Bonding Material: Insulation Base layer: Base Insultation Size and Thickness: Base Insulation Fastener/Bonding Material: Top Insulation Layer: Top Insulation Size and Thickness: Top Insulation Fastener/Bonding Material: Base Sheet(s) & No. of Ply(s): Base Sheet Fastener/Bonding Material: Ply Sheet(s)' & No. of Ply(s): Ply Sheet Fastener/Bonding Material: Top Ply: Top Ply Fastener/Bonding Material: Surfacing Fastener Spacing for Anchor/Base She t Attachment: Zone 1':_." ac @ Lap, p Row ® "oo Zone 1:�," oc @ Lap, ff Rows _ ® no Zone 2:_" oc @ Lap, k Rows — ® —" oc Zone 3:_" oc @ Lap, g Rows_* _" oc Number of Fasteners Per Insulation B rd: Zone 1':_Zone 1:_Zone 2 Zone 3: Illustrate Components Noted and Deta Is as Applicable: Woodblockin& Gutter, Edge Teri iination, Stripping, Flashing, Continuous Cleat, Cant SAP, Base Flashing, Counterflashing, Coping, Etc. Indicate: Mean Roof Height, Parapet H Nght, Height of Base Flashing, Component Material, Materia 'Thickness, Fastener Type, Fastener Spacing or Submit Manu. acturers Details that Comply With RAS 111 and Chapter 16—. —L- Parapet Height Mean Roof Height ST. LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer: Notire of Acceptance Number: Minimum Design Wind Pressures, If Applicable (From RA5 127 or Calculations): Zone I:: "Zone 2e^._ Zone 2n:,Zone 2r72112one 3e- � Zone 3r.~9q Deck Type: Type Underlayment: Roof Slope: Insulation: RidgWtiion7 Mean Roof Height: Fire barrier: Fastener Type S Spacing: 1( I Ala. Adh8a va Type: \ Type Cap Sheet: Roof Covering; v -1 Type & Size Drip� i Edge: W ST. LUCIE Section E (Tile Calculations) For Moment based tile systems, choose either Method 1 or 2. Compare the values for M, with the va are greater than or equal to the M, values, for each area of the roof, then the tile attachment methi (zone x Method 1'Moment Based Tile Calculations Per RAS 12T _ _. _ � - Mg: _ = MN _ Product Approval M._ (Zone 2ee : _x __ _)- Mg: =Mfz•_ Product Approval Mr--xl_= _-1_Mg: _=M m, _ Product Approval Mr — (Zone 2r; —xll_: _)_Mg: _Mo_ Product Approval Mi_ (Zone3e: _x%__w _)_ Mg: _=M A.— Product Approval M, (Zone 3r; —xX_a _a- Mg: _=M*_ Product Approval Mr_ Method 2 "Simplified Tile Calculations Per Table Below" Required Moment of Resistance (Mr) From Table Below Product Approval Mi _ _ Mr required Moment Resistance* Mean Roof Height Roof Slope 15' 20' 25 30' �— 2:12 - - _ 34.4 �_ 36_5 38.2 39.7 _ 3:12 32.2 34.4 .r. 36A 37.4 _ 4:22 _ 30.4� L.2 33.8 —32.8 -- 6:12 26.4 28.0 -- - �.4 � 30.5 I _ 7:12 �- 24.4 25.9 27.1 _28.2 'Must be used in conjunction with a list of moment based tale systems -- For Uplift based the systems use Method 3. Compare the values for F' with the values for Fr If the F' equal to the F, values, for each area of the roof, then the tile attachment method is acceptable. Method 3 "Uplift Based Tile Calculations Per RAS 12T (Zone 1: _x L,_ x W:- Method _W;_ cos r= F,:_ Product Approval F'_ (Zone 2e: _x L_ x W;=) -W:—cos r= F,2._ Product Approval F'_ (Zone 2n: xL=xW;=_)-W:_cos r= pprovalF' Frz"_ Product _ (Zone 2r: _x L_ x W.-- -W:_ cos r _=F,r_ Product Approval F' (Zone 3e: _x L= x W:=_) -W:— cos r_4r3e— Product Approval F'— _ (Zone 3r: __x L_ x W:=_J -W: cos r =F,t,_ Product Approval F'_ -- — —Where to Obtain Information Description Symbol T - — ( --- -- --I— - _ _ Where to find Design Pressure Zones 1, 2e, 2n, 2r, 3e, 3r From applicable table in RAS 127 or by an erq - .-- prepared by PE haled on ASCE 7 Mean Roof Height H Job Site Root Slope _ _ B Job Site — Aerodynamic Multiplier a _ Product Approval - Restoring Moment duet, Gravity M, Product Approval Attachment Resistance _ Mr Product Approval LRequired Moment Resistance Mr Calculated Minimum Attachment Resistance-- _ IV Product Approval Required Uplift Resistance F. Calculated Average Tile Weight W Product Approval Tile Dimensions L = length W =width Product Approval - All calculations must be submitted to the building official at the time of permit application. ,s from Mi. If the Mi values is acceptable. are greater than or !ring analysis 1 — J