Loading...
HomeMy WebLinkAboutAPPROVED, _11-09-2021_Planset - Reviewed-S&SVICINITY MAPSITE MAP (N.T.S)A-01SITE MAP &VICINITY MAPDENISE TORRESNEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEMDC SYSTEM SIZE (11.455 KW)33°C0°C0 PSF160MPH (ASCE 7-16)IICWIND FLOW MAPSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809GOVERNING CODESFLORIDA RESIDENTIAL CODE, 7TH EDITION 2020 (FRC)FLORIDA BUILDING CODE, 7TH EDITION 2020 (FBC)FLORIDA FIRE PREVENTION CODE, 7TH EDITION 2020 (FFPC)NATIONAL ELECTRIC CODE, NEC 2017 CODE BOOK, NFPA 70SITE DETAILSASHRAE EXTREME LOWASHRAE 2% HIGHGROUND SNOW LOADWIND SPEEDRISK CATEGORYWIND EXPOSURE CATEGORYTHIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MINDY NICOLE O'NEAL, PE ON THE DATE ADJACENT TO THE SEAL. PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.LAYOUT SUBJECT TO CHANGEBASED ON SITE CONDITIONS41.1"74"8.41 KWSYSTEM SIZE :11.455 KW DC STC35.09 A(29) ENPHASE IQ7PLUS-72-2-USMICROINVERTERSBACKFEED BREAKER IN METER MAIN COMBO DC RATING OF SYSTEMAC RATING OF SYSTEMAC OUTPUT CURRENTNO. OF MODULESNO. OF INVERTERSARRAY STRINGINGDESCRIPTIONNEW GRID-INTERACTIVE PHOTOVOLTAICSYSTEM WITH NO BATTERY STORAGESYSTEM DETAILS(29) HANWHA Q.PEAK DUO BLK ML-G10(395W) MODULESPOINT OF INTERCONNECTIONSITE MAP & VICINITY MAPA - 01A - 02S - 01SINGLE LINE DIAGRAMWIRING CALCULATIONSSYSTEM LABELINGMODULE DATASHEETE - 01E - 02E - 03STRUCTURAL ATTACHMENT DETAILSINVERTER DATASHEETDS - 01DS - 02DS - 04S - 02SHEET INDEXSHEET NO.SHEET NAMEROOF PLAN & MODULESARRAY LAYOUTCOMBINER BOX DATASHEETATTACHMENT DATASHEETDS - 05DS - 06RACKING DATASHEETDS - 03JUNCTION BOX DATASHEET(2) BRANCHES OF 10 MODULES(1) BRANCH OF 09 MODULES51' - 5 "106'-8"5 1 ' - 5 "106'-8"21'-7"3 ' - 8 " 3 ' - 1 1 "ROOF 1ROOF 2ROOF 3MPV ARRAY3' SETBACKARLINGTON W A Y D R I V EW A Y(E) METER MAIN COMBO(OUTSIDE HOUSE)18" SETBACK A-02 & MODULESROOF PLANMODULE TYPE, DIMENSIONS & WEIGHTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809I CERTIFY THAT THE INSTALLATION OF THE MODULES IS INCOMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3.BUILDINGSTRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFTWIND LOADS, AND EQUIPMENT DEAD LOADS. *GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS TO TRUSSES SHALL BE INSTALLEDAS SHOWN IN SHEET S-01 AND AS FOLLOWS FOR EACH WINDZONE:.WIND ZONE 1: MAX SPAN 4'-0" O.C. WIND ZONE 2: MAX SPAN 2'-0" O.C. WIND ZONE 3: MAX SPAN 2'-0" O.C.2) EXISTING RESIDENTIAL BUILDING ROOF WITH MEAN ROOFHEIGHT 30 FT AND 2"X4" WOOD ROOF TRUSSES SPACED 24" O.C.CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THEENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANSAND IN FIELD CONDITIONS.LEGENDSUMACDPMMSP- UTILITY METERJB- AC DISCONNECT-PRODUCTION METER- MAIN SERVICE PANEL- VENT, ATTIC FAN(ROOF OBSTRUCTION)- JUNCTION BOXCP- COMBINER PANEL- CONDUIT- MICROINVERTER- FIRE SETBACKNUMBER OF MODULES = 29 MODULESMODULE TYPE = HANWHA Q.PEAK DUO BLK ML-G10 (395W) MODULESMODULE WEIGHT = 48.50 LBS / 22 KG.MODULE DIMENSIONS = 74" X 41.1" = 21.12 SFNUMBER OF INVERTER = 29 MICROINVERTERSINVERTER TYPE = ENPHASE IQ7PLUS-72-2-US MICROINVERTERSDC SYSTEM SIZE: 11.455 KWAC SYSTEM SIZE: 8.41 KWNOTES:1. LOCATION OF JUNCTION BOX(ES), ACDISCONNECTS(S), AC COMBINER PANEL(S), ANDOTHER ELECTRICAL EQUIPMENT(S) RELEVANT TOPV INSTALLATION SUBJECT TO CHANGE BASEDON SITE CONDITIONS.2. SETBACKS AT RIDGES CAN BE REDUCED TO 18INCHES IN COMPLIANCE WITH FBC R 324.6.2:TOTAL PLAN VIEW AREA = 2340.9 SQFTTOTAL PV AREA = 29(74 IN)(41.1 IN)/(144 IN^2) = 612.5 SQFT( 612.5 SQFT/ 2340.9 SQFT)100 = 26.17 %TOTAL PV AREA POPULATES 26.17 % OF TOTALPLAN VIEW AREA AND IS WITHIN THE 33%REQUIREMENT.M- METER MAIN COMBOM(E) METER MAIN COMBO(OUTSIDE HOUSE)ROOF 2PV ARRAYROOF 3ROOF 1JBACDCP(N) AC DISCONNECT(N) COMBINER PANELCONDUIT RUN3' SETBACKROOF ACCESS POINTROOF ACCESS POINT18" SETBACK S-01ARRAYLAYOUTROOF DESCRIPTION:SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809WIND LOAD INFORMATION:THIS SYSTEM HAS BEEN DESIGN TO MEETTHE REQUIREMENTS OF THE 7TH EDITION OFTHE FLORIDA BUILDING CODE AND USED THE FOLLOWING DESIGN PARAMETERS: ULTIMATE WIND SPEED: 160 MPH EXPOSURE CATEGORY: C RISK CATEGORY: II MEAN ROOF HEIGHT: 30 FEETROOF SLOPE: 20-27°LEGENDS- VENT, ATTIC FAN(ROOF OBSTRUCTION)- PV ROOF ATTACHMENT- RAFTERS / TRUSSES- FIRE SETBACKWIND ZONE 1- WIND ZONE 1-WIND ZONE 1'WIND ZONE 2- WIND ZONE (2)-WIND ZONE (2r)- WIND ZONE (2e)- WIND ZONE (2n)WIND ZONE 3- WIND ZONE (3)-WIND ZONE (3r)- WIND ZONE (3e)- RAIL- METAL SEAM(ROOF #1)MODULES - 16ROOF TILT - 22°ROOF AZIMUTH - 224°TRUSSES SIZE - 2"X4" @ 24" O.C.(ROOF #3)MODULES -08ROOF TILT - 22°ROOF AZIMUTH - 44°TRUSSES SIZE - 2"X4" @ 24" O.C.(ROOF #2)MODULES - 05ROOF TILT - 22°ROOF AZIMUTH - 134°TRUSSES SIZE - 2"X4" @ 24" O.C.- SOLARSTACK MOUNTTRUSS LOCATIONS ARE APPROXIMATE.ACTUAL LOCATIONS MAY DIFFER ANDCONTRACTOR MAY NEED TO ADJUST MOUNTLOCATIONS. IN NO CASE SHALL THE MOUNTSPACING EXCEED "MAX. MOUNT SPACING"12'-2"6'-6"19'-1" 2 5 ' - 5 " 17'-11"35'18'49'-10"SOLAR MODULE18" SETBACKROOF #1ROOF #210'-2"17'-5"8'-6"33'-5"8'-11"24'-9"3' SETBACKROOF #3 S-02STRUCTURAL ATTACHMENTDETAILSSTRUCTURAL ATTACHMENT DETAILSSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809:103PHOTOVOLTAIC MODULE GENERAL NOTES:1. APPLICABLE CODE: 2020 FLORIDA BUILDING CODE 7th ED. & ASCE 7-16MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES.2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER NDS(2012)REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON AWOOD ROOF TRUSS AS EMBEDMENT MATERIAL.3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLERESIDENTIAL ROOFS, CONSIDERING FROM A 7° TO A MAXIMUM 27° (2/12 TO AMAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. ALL RESIDENTIAL ROOFS SHALL NOTEXCEED 30'-0" MEAN ROOF HEIGHT.4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511.5. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TOMANUFACTURERS' MANUAL FOR ALL ARCHITECTURAL, MECHANICAL,ELECTRICAL, AND SOLAR SPECS.6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESSOTHERWISE NOTED.7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED.8. ALL RAILING AND MODULES SHALL BE INSTALLED PERMANUFACTURERS' INSTRUCTIONS.9. I CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCEWITH FBC:BUILDING CHAPTER 16 AND FBC:RESIDENTIAL CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE CALCULATEDWIND LATERAL AND UPLIFT FORCES, AND EQUIPMENT DEAD LOADS.SUNMODO TOP TILE : 74Q RAIL LIGHT:16Q MOUNT END CLAMP: 32Q MOUNT MID CLAMP: 42Q MOUNT GROUND LUG : 8HANWHA Q.PEAK DUO BLK ML-G10 (395W) : 29 ENPHASE IQ7PLUS-72-2-US: 2960A UNFUSED AC DISCONNECT: 1SOLAR MODULERAFTERSSUNMODO TILE REPLACEMENTFLASHING (BARREL TILE)WOOD SHEATHINGQUICK MOUNT QRAIL (LIGHT)QUICK MOUNT(L-MOUNT)5/16"x4" STAINLESSSTEEL LAG SCREWBOM E-01SINGLELINE DIAGRAMSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809SOLAR ARRAY (11.455 KW-DC STC)(29) HANWHA Q.PEAK DUO BLK ML-G10 (395W)MODULES(2) BRANCHES OF 10 MODULES(1) BRANCH OF 09 MODULESPER FL. STATUE 377.705 (REVISED 7/1/2017) I, MINDY NICOLE O'NEAL PE#69779, AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE.INTERCONNECTION120% RULE - NEC 705.12(B)(2)(3)(b)UTILITY FEED + SOLAR BACKFEED175A + 50A = 225 ABUS RATING x 120%200A x 120% = 240AMODEL NO.HANWHA Q.PEAK DUO BLK ML-G10PEAK POWER395WRATED VOLTAGE (Vmpp)36.88 VRATED CURRENT (Impp)10.71 AOPEN CIRCUIT VOLTAGE (Voc)45.27 VSHORT CIRCUIT CURRENT (Isc)11.10 AMODULE SPECIFICATIONINVERTER SPECIFICATIONSMANUFACTURERENPHASEMODEL NO.IQ7PLUS-72-2-USMAX DC INPUT VOLTAGE60 VMAX OUTPUT POWER290 VANOMINAL AC OUTPUT VOLTAGE240 VNOMINAL AC OUTPUT CURRENT1.21 AG1 STRING OF10 MODULES WITHMICROINVERTERS1 STRING OF10 MODULES WITHMICROINVERTERS1 STRING OF09 MODULES WITHMICROINVERTERS20A/2P20A/2PG20A/2PENVOY IQ15A/2P(3) #10 AWG THWN-2 - L1(3) #10 AWG THWN-2 - L2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUN(N) JUNCTIONBOX(N) IQ ACCOMBINER PANELENPHASE Q CABLES(1) #6 BARE COPPER GNDGNUM(N) 50A(N) 175A(E)200AMETER MAIN COMBO120/240V(N)BACKFEED BREAKER(N) 60ACDISCONNECTGUNFUSED(3) #8 AWG THWN-2(1) #10 AWG THWN-2 GNDIN 3/4" IMC, RMC, FMC, LFMC,PVC, HDPE, NUCC, RTRC,LFNC, FMT, ENT OR EMTCONDUIT RUNNOTE:1. SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THEREQUIREMENTS OF THE NEC 2017, NFPA 70 AND THOSE SET FORTH BYTHE FLORIDA SOLAR ENERGY CENTER CERTIFICATION, INCLUDINGMAXIMUM NUMBER OF MODULE STRINGS, MAXIMUM NUMBER OFMODULES PER STRING, MAXIMUM OUTPUT, MODULE MANUFACTURERAND MODEL NUMBER, INVERTER MANUFACTURER AND MODELNUMBER, AS APPLICABLE.2. PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTERSPACE IS INADEQUATE.3. IF METER MAIN COMBO CONTAINS FEED THRU LUGCONTRACTOR SHALL VERIFY THAT THE FEEDERS CONNECTED TO THESE LUGS ARE PROTECTED AS REQUIRED BY NEC 705.12(B)(2)(1)(A) OR (B). E-02WIRINGCALCULATIONSMAX VOLTAGE DROP CALCULATIONCABLE SIZECABLE DESCRIPTIONONE WAYDISTANCE INFEET (D)BRANCHCURRENT (I)RESISTANCE OFCONDUCTOR(R)VOLTAGE (V)% VOLTAGEDROP=(0.2*D*I*R)/V#10 THWN-2JUNCTION BOX TOCOMBINER PANEL2035.091.242400.73SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809ELECTRICAL CALCULATIONS:1. CURRENT CARRYING CONDUCTOR(A)BEFORE IQ COMBINER PANELAMBIENT TEMPERATURE = 33°CCONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(c)TEMPERATURE DERATE FACTOR - 0.96 ...NEC 310.15(B)(2)(a)GROUPING FACTOR - 0.8...NEC 310.15(B)(3)(a)CONDUCTOR AMPACITY= (INV O/P CURRENT ) x 1.25 / A.T.F / G.F ...NEC 690.8(B)= [(10 x 1.21) x 1.25] / 0.96 / 0.8= 19.69 ASELECTED CONDUCTOR - #10THWN-2 ...NEC 310.15(B)(16)(B)AFTER IQ COMBINER PANELTEMPERATURE DERATE FACTOR - 0.96GROUPING FACTOR - 1 CONDUCTOR AMPACITY=(TOTAL INV O/P CURRENT) x 1.25 / 0.96 / 1 ...NEC 690.8(B)=[(29x 1.21) x 1.25] /0.96 / 1=45.69 ASELECTED CONDUCTOR - #8 THWN-2 ...NEC 310.15(B)(16)2.PV OVER CURRENT PROTECTION ..NEC 690.9(B)=TOTAL INVERTER O/P CURRENT x 1.25=(29 x 1.21) x 1.25 = 43.86 ASELECTED OCPD = 50ASELECTED EQUIPMENT GROUND CONDUCTOR (EGC) = #10 THWN-2 ... NEC 250.122(A)ELECTRICAL NOTES1. ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION2. ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90DEGREE C WET ENVIRONMENT.THE TERMINALS ARE RATED FOR75 DEGREE C.3. CONDUCTOR TERMINATION AND SPLICING AS PER NEC 110.144. WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE ASPOSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.5. WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.6. DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMSCONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS,SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLECODES AND STANDARDS.7. WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITSARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEMACCORDINGLY.8. ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELEDAND READILY VISIBLE.9. MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULEFRAME AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIPMANUFACTURER'S INSTRUCTION.10. MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPERG.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG.11. THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE .12. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICEENTRANCE.13. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703.14. RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.15. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) AND ARTICLE310.10 (D).16. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLEFOR USE IN WET LOCATIONS PER NEC ARTICLE 310.10 (C). WARNINGELECTRIC SHOCK HAZARD!DO NOT TOUCH TERMINALSTERMINALS ON BOTH LINE ANDLOAD SIDES MAY BE ENERGIZEDIN THE OPEN POSITIONPHOTOVOLTAIC SYSTEM AC DISCONNECTRATED AC OPERATING CURRENT 35.09 AMPSAC NOMINAL OPERATING VOLTAGE 240 VOLTSWARNINGINVERTER OUTPUT CONNECTION DO NOTRELOCATE THIS OVERCURRENT DEVICEPHOTOVOLTAIC SYSTEMEQUIPPED WITH RAPIDE-03WARNING DUAL POWER SOURCESECOND SOURCE IS PHOTOVOLTAIC SYSTEMWARNING PHOTOVOLTAICPOWER SOURCE!727-571-4141EMERGENCY CONTACTWARNING!INVERTER OUTPUT CONNECTIONDO NOT RELOCATE THISOVERCURRENT DEVICEWARNING!DEDICATED SOLAR PANELS DONOT CONNECT ANY OTHER LOADSSHUTDOWNSOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWNSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809SYSTEMLABELINGLABEL LOCATION:AC DISCONNECT, POINT OF INTERCONNECTION, COMBINER PANEL(PER CODE: NEC 690.13(B))LABEL LOCATION:AC DISCONNECT, INVERTER(PER CODE: NEC 690.54)LABEL LOCATION:CONDUIT RUNWAY(PER CODE: NEC690.31(G)(3)(4))LABEL LOCATION:MAIN SERVICE DISCONNECT(NEC 705.12(B)(3-4) & NEC 690.59)ADHESIVE FASTENED SIGNS:·ANSI Z535.4-2011 PRODUCT SAFETY SIGNS AND LABELS, PROVIDESGUIDELINES FOR SUITABLE FONT SIZES, WORDS, COLORS, SYMBOLS, ANDLOCATION REQUIREMENTS FOR LABELS. NEC 110.21(B)(1)·THE LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED. NEC 110.21(B)(3)·ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLYADHERED. VINYL SIGNS SHALL BE WEATHER RESISTANT. IFC 605.11.1.3LABEL LOCATION:COMBINER PANEL, AC DISCONNECT(PER CODE: NEC 690.52)LABEL LOCATION:POINT OF INTERCONNECTION, MAIN SERVICE DISCONNECT(PER CODE: NEC 705.12 (B)(2)(c))[Not required if panelboard is rated not less than sum of ampere ratingsof all overcurrent devices supplying it]DATA PER PANELLABEL LOCATION:AC DISCONNECT, DC DISCONNECT, POINT OFINTERCONNECTION(PER CODE: NEC 690.56(C)(3))IFC 605.11.3.1(1) & 690.56(C)(1)(a) Label for PV Systems thatShut down the array and the conductors leaving the arrayNOMINAL OPERATING AC VOLTAGE -NOMINAL OPERATING AC FREQUENCY-MAXIMUM AC POWER-MAXIMUM AC CURRENT-MAXIMUM OVERCURRENT DEVICE RATINGFOR AC MODULE PROTECTION PER CIRCUIT-2402901.2120VVA 60 HzAA DS-01DATASHEETMODULESHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-02DATASHEETINVERTERSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 SHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809DATASHEETJUNCTION BOXDS-03 DS-04DATASHEETCOMBINER BOXSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-05DATASHEETATTACHMENTSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809 DS-06DATASHEETRACKINGSHEET NUMBERSHEET NAMEDESCRIPTIONREV REVISIONS DATEPERMIT DEVELOPEROMD11/15/2021DESIGNERREVIEWERDATEDENISE TORRES 6127 ARLINGTON WAY, FORT PIERCE, FL 34951, USA ADD : 7300 BRYAN DAIRY RD SUITE400 SEMINOLE FL 33777, USACONTACT : 7275714141LICENSE #AEC-07807ENGG.CONTACT: (561) 444 81925700 LAKE WORTH ROAD SUITE 211GREENACRES, FL 33463,USAFLORIDA REGISTRY# 33809