HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING3/1912021 Florida Building Code Online
BCIS Home ; Log In ;User Registration r riot Topics Submit Surcharge Stats &Facts I Publications Contact Us . BCIS. Site Map ,Links Search '
db r Product Approval
USER: Public User
Product Anoroval Menu > Product or Ap-pNcallon Search > gRpRcatlort list > Application Data11 ly
•tea x.
*r FL # FL30343-R2 f1�
Application Type Revision ^�
Code Version 2020/
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Premier Metal
17613 South Hwy, 475
Summerfield, FL 34491
(352) 356-1609
fivalidation@yahoo.com
Ray Bowen
flvalidation@yahoo.com
Roofing
Metal Roofing
FILE Cppy
Evaluation Report from a Florida Registered Architect or a Licensed Florida
'Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the David Eng
Evaluation Report
Florida License PE-81377
Quality Assurance Entity PRI Construction Materials Technologies, LLC
Quality Assurance Contract Expiration Date 08/03/2022
Validated By 3ames R Wally, PE
Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL30343 R2 COI 26ga 5VCrimo_p1ywood.pdf
Standard
UL 580
Year
2006
https:l/flbridabuilding.org/pr/pi app_dtl.aspx?param=wGEVXQwtDgvH%2bffZfjpUCYkVDshJc8dKAmGMcj5Xf7g3obLigxVr3Q%3d%3d 1/3
3/23/202'1
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approveo
Florida Building Code Online
Method i Option D
10/21/2020
10/25/2020
10/28/2020
Summary of Products
FL # Model, Number or Name Description
30343 1 01: 26ga 5V Crimp over plywood 26ga (min) 5V Crimp over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5
Other: 108.5psf with 12"-12" pattern at 12"oc
Installation Instructions
FL30343 R2 II 26oa SVCrimp pywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343 R2 AE 26ga SVCrimp ply yO d.Ddf
Created by Independent Third Party: Yes
30343.2 02: 26ga PermaShield over plywood 126ga (min) PermaShield screw strip over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116
Other: 116psf fastener every hole WITH sealant, 71psf
fastener every other hole
Installation Instructions
FL30343 R2 II 26ga PermaShield olywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343 R2 AE 26ga PermaShield plywood.pdf
Created by Independent Third Party: Yes
30343.3 03: 032 Aluminum PermaShield over Nominally 032 or thicker aluminum PermaShield screw strip
plywood over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-153.5
Other: 153.5 with fastener every hole WITH sealant, 86psf
with fastener every hole with OUT sealant.
Installation Instructions
FL30343 R2 II 032AI PermaShield pjywood.pdf
Verified By: David. Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
EU0343 R2 AE 032AI PermaShield pjywoo . df
Created by Independent Third Party: Yes
30343.4 04: 26ga TuffRib over plywood 26ga (min) TuffRib over.15/32" (min) plywood
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL30343 R2 II 26ga TuffRib pjyoo R_0f
Approved for use outside HVHZ: Yes Verified By: David Eng, PE 81377
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-123.5 Evaluation Reports
Other: 123.5psf with 6.5"-2.5"-6.5"-2.5" fastener pattern @ FL30343 R2 AE 26oa TuffRib p--d.pdf
12" oc, 82.25psf with 9"-9"-9" fastener pattern @ 24" oc Created by Independent Third Party: Yes
30343.5 05: 032 Aluminum DuraSeam over Nominally 0.032" or thicker aluminum DuraSeam over 15/32"
plywood (min) plywood
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5
Other: 108.5 psf with clips @ 18" oc
Installation Instructions
F00343 R2 II 032AI D ra am pjywood.p�f
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343 R2 AE 032AI DuraSeam pl Lo .pff
Created by Independent Third Party: Yes
30343.6 ( 06: 26ga DuraSeam over plywood 126ga (min) DuraSeam over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.5
Other: 93.5psf with clips @ 12" oc, 63.5psf with clips @ 16"
oc
30343.7 1 07: 29ga TuffRib over plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5
Installation Instructions
FL30343 R2 II 26oa DuraSeam plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
FL30343 R2 AE 26ga DuraSeam plywood.pdf
Created by Independent Third Party: Yes
29ga (min) TuffRib over 15/32" (min) plywood I Fastener in the
rib
Installation Instructions
FL30343 R2 I1 29ga TuffRib Plywood -rib Dd
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Evaluation Reports
https://floridabuilding.org/prlpr app dtl.aspx?param=wGEVXQwtDgvH%2bffZfjjpUCYkVDshjcBdKAmGMcj5Xf7g3obUgxVr3Q%3d%3d 2/3
3/19/2021
J
Florida Building Code Online
Other: 123.5 psf with 9"-9"-9" fastener pattern @ 12" cc,
FL30343 R2 AE 29gaTuffRib Plywood-rib.pdf
56psf @ 24" cc
Created by Independent Third Party: Yes
30343.8
08: 299a TuffRib on 1x4 battens over
plywood
29ga (min) TuffRib.on 1x4 (nom) battens, over 15/32" (min)
plywood
I.iMM. of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131
Other: 131 psf with 9"-9"-9" fastener pattern @ 12" cc,
78.Spsf C@ 24" cc
Installation instructions
FL30343 R2 II 29oa Tuff kib IX4.Odf
Verified By: David Eng, PE 81377
Created -by Independent Third Party: Yes
Evaluation Reports
FL30343 R2 AE Z9ga TuffRib 1X4.pdf
Created by Independent Third Party: Yes
30343.9
09: 29ga TuffRib over plywood
29ga (min) TuffRib over 15/32" (min) plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Installation Instructions '
FL30343, R2 II 29ga TuffRib Plywood.pdf
Verified By: David Eng, PE 81377
Created by Independent Third Party: Yes
Design Pressure: +N/A/-93.5
Other.: 93.5 psf with 9"-9"-9" fastener pattern @ 12" oc, 56psf
@ 24" cc
Evaluation Reports
FL30343 R2 AE 29ga Tuff klb Plywood pdf
Created by Independent Third Party: Yes,
Contact Us :: 2601 Blair Stone Road, Tallahassee Fl- 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Lopyhght 2007-2013 State of Florida.:: PrIvagir statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do notwant your e-mail address released in response to.a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls i
provided may be used for official communication with the licensee. However email addresses'are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
FC�kCt
1 I
Credit. Card'
Safe
hhps://floridabuilding.org/p-ripr app dti.aspx7patam=wGEVXQwtDgvHa/a2bffZfjjpUCYkVDshJc8dKAmGMcj5Xf7g3obLlgxVr3Q°/a3d%3d
313
✓ ' I,
-FL30343.07-R2
PG 1
FLORIDA PRODUCT APPROVAL
29GA TuffRib over 15/32 Plywood
Premier Metal Roof Manufacturing
17613 S. Hwy475 Summerfield FL 34491
www.PMRoof.com 352-356-1609
Product Description
Exposed fastener, rib style panel. Panel coverage is nominally
36" with nominal rib height of 3/4"
Product Material: 29ga (min) steel
29ga is nominally 0.0142" with yield strength of at least 50ksi, and
shall be corrosion resistant per FBC 1507.4.3 where required
Fastener: #10 x 1.5 inch fastener with sealing washer
Compliant with FBC 1506.6 where required.
Substrate/Deck: 15132" (min) plywood. Panel may be installed
over an optional layer of shingles.
Maximum Allowable Loads & Installation Requirements:
Method A: #10 x 2" fastener in 9"-9"-9"-9" pattern through the rib
.CcD- 24" oc: 56 PSF
Method B:: #10 x 2" fastener in 9"-9"-9"-9" pattern through the rib
12" oc::
123.5 PSF
A factor of safety of 2 has been applied.
Evaluated by:
David Eng, PE I Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesv ```+++►+I
FL PE 81377 1 FL CA 33344 J\O E. F %�
www.TimberLakeCove.com pP''��cErvsF'G
David E Eng No. 81377
��2020.10.18
22:19:56+01.00' — This item has been digitally signed and —
seated by D.E. Eng, PE, on the date �0 ' STATE OF :' [(/�`
indicated. Printed copies of this document �'"- fZOR►Op' • G\��
are not considered signed and seated and �i� is,
the signature must be verified on any �i� IONAL
electronic copies
PM ROORCOM
TUFF
Exposed Fastener Ribbed Panel
FL30343.07-R2
PG 2
Underlayment: Comply with local building code or FBC 1507.1.1.
Slope: Comply with local building code or FBC 1507.4.2.
Technical Documentation:
This product has-been tested to UL 580 by Intertek Testing (TST-1527), report K9550.01-450-44.
Compliance Statement:
This product -as described has demonstrated compliance with Florida Building Code 2020, 1504.3.2 (non-
HVHZ) as required by FL Rule 61 G20-3, method 1 D. .
This product as described has been tested and demonstrated compliance with:
• UL580 — Test for Uplift Resistance of Roof Assemblies
• UL 1897 — Uplift test for roof covering systems
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The same entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2, as required by
Rule 61G20-3. Neither Timberlake Cove- nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product.
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement for the
applicable wind loads for roofs, within the parameters described. For roofs outside of the listed parameters,
design wind loads shall be determined as required: by FBC 1609, ASCE 7, or other design code in. force,
using allowable stress. These load tables are based on ASCE 7-16. Use of these tables assumes that the
structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a site location
for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific approval by local
authorities having jurisdiction.
JkJJ PM ROORCOM
each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept. For the load tables
below, the worst case was taken for each zone and reported using the standard
zones 1-2-3:
Zone 1 includes zones 1 and 1°
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple scheme, at the expense of some
design efficiency. Contact the manufacturer for further information, or consult a
licensed design professional.
METHOD A: 24" O.C.
R2
'G 3
Lio".OF LEAST RO=IT.V. O:.t•.E ZI.l OR R it •'M0C1:E'IER IS V—LER nut NOT
SST MERNCR—OF EC. THORSONTt Ci RSIONCRIF' IoW-
ORASDETERLLD D By OESIGN OR O7,tVj - FtkKE CODE.
ROOF ZONES FOR GENERIC BUILDING
METHOD B: 12" O.C_
NR: CONSULT DESIGN
�91' 9" 9" 91T---I PROFESSIONAL
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof, or gablelhip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
FL30343.07: 29 a Tuffrib on 15/32'° I
ood
FL30343.07: 29 a Tuffrib on 15/32" plywood
!find
105 110 120 130 140 150 160 170 180 190 200
Wind
105 110 120 130 140 150 160 170 180 190 20C
?one 1:
A A A A A A A B
B B B
Zone 1:
A A A A B' B, B' B.
Ane 2:
A A A_ A. B B B B-
B B B;
Zone 2:
A ?, B, B- B, B-• `: B
Zone 3:
A A A B. B.- B_JB. B.
B.
Zone3:
B.: B B _ B._ B:
Use this load table for structures which meet the following criteria: Use this toad table for structures which meet the following criteria: I I.
Are located in Exposure B area Are located in B, C, or D exposure area
Have either a flat roof less than 1.5:12, hip roof with Have either a flat roof less than 1.5:12, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 -12:12 max slope of 12:12, or gable roof with slope between 4.4:12 -12:12
Have a mean Roof Height of 30 feet or less Have a mean Roof Height of 30 feet or less
FL30343.07: 29 a Tuffrib on 15/32" Plywood FL30343.07: 29 a Tuffrib on 15132°' 2LOood
Wind 105 110 120 130 140 150 160 170 180 190 200 Wind 105 110 120 130 140 150 160 170 180 190 200
Zone 1: A A A A A A A A B. B B Zone 1: A A A A B B B' B. B B B
Zone 2: A A A A A B, B B B B B Zone 2: A A B B B B B• B
Zone 3: A A A A. B B &.. B B B. Zone 3: B B_ B B_. B- .13
Jill PMROOF.COM
t
;I