Loading...
HomeMy WebLinkAboutNOTICE OF PRODUCT CERTIFICATION 1-13-17 NOTICE OF PRODUCT CERTIFICATION °4 CERTIFICATION NO: NI011567.04-R3 DATE: 05/23/2013 CERTIFICATION PROGRAM: Structural COMPANY: JELD-WEN ` CODE: 1822-1 REVISION DATE: 01/13/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICei-tification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl Single Hung(8100)" 3737 Lakeport Boulevard Impact Rated Vinyl Single Hung Window Klamath Falls, OR 97601 (Fin or Flange Installation) Configuration:O/X Glazing:IG-1/8"Annealed Glass/Laminate- 1/8"Annealed Glass/0.090"PVB Interlayer by DuPont/ 1/8"Annealed Glass or IG-1/8"Annealed Glass/Laminate- 1/8"annealedGlass/0.090"SentryGlas Plus by DuPont/ 1/8"Annealed Glass Frame: W-914mm(36") H-1829mm(72") Sash: W-845mm(33.25") H-883mm(34.75") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +65/-70 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3875-1 Expiration Date: April 30,2025 FILE COPY Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 398 E. DaniaBeach each Blvd. BUILDING DROPS Suite338 //A\\ Dania Beach, FL 33004 A Perfect Solution in Every Drop 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of JELD-WEN, Inc. Premium Atlantic Vinyl Single Hung - Impact for Florida Product Approval Report No. 3094 Current Florida Building Code Method: 1 —A (Certificate) Category: Windows Sub — Category: _Single Hung Product: Premium Atlantic Vinyl Single Hung-Impact Material: PVC Product Dimensions: 36"x 72"(O/X) Prepared For: JELD-WEN, Inc. 3737 Lakeport Blvd. Klamath Falls, OR 97601 Prepared by: Hermes F. Norero, P.E. �``��ES F. Florida Professional Engineer# 73778 ����Q- .•••" �i� Date: 08/11/2014 .�O 7 Contents: Evaluation Report Pages 1 —4XN Digitally signed by Hermes F. Norero,�• .FS�''••••••••'•• Gam`,•`� Reason: I am approving this document Date:2014.09.19 16:31:49-04 00 Hermes F. Norero, P.E. Florida No. 73778 BUILDING DROPS Date: 0 : 30 4 Report No Date: : 94 ® A Perfect Solution in Every Drop Certificate of Authorization:29578 Manufacturer: JELD-WEN, Inc. Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl Single Hung—Impact (Impact) 36" x 72" (0/X) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN, Inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation- Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3875-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL# 73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing NCTL210-3875-1-FBC require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions NCTL210-3875-1-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No.73778 Page 2 of 4 BUILDING DROPS Date: 0 : 30 4 Report No: 94 A Perfect Solution in Every Drop Certificate of Authorization:29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization#: QUA 1789). Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW (FBC Organization# TST9341) Report#: NCTL-210-3875-1, Report Date:4/18/2013 2. Certification Agency National Accreditation and Management Institute (FBC Organization#: CER 1773) 3. Material Certification Miami Dade RER—Product Control Section NOA E.I. DuPont De Nemours&Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER—Product Control Section NOA Quanex Building Products: PVC Extrusions Hermes F. Norero, P.E. Florida No.73778 Page 3 of 4 BUILDING DROPS Date: 0 : 30 4 Report No: 94 A Perfect Solution in Every Drop Certificate of Authorization:29578 Through Frame Installation: 1. Approved anchor types and substrates areas follows: A. For concrete (Min.f c=3000 psi) or masonry substrate (Min.f c= 1500 psi)where one by(1X), non-structural, wood bucking is employed, use (1)3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. B. For concrete (Min.fc=3000 psi) or masonry substrate (Min.f c= 1500 psi)where wood bucking is NOT employed, use (1)3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel substrate, use(1)#8 Tek Screw type steel frame (min. 18ga.) anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation (Where applicable): A. For wood substrates (Min.S.G. =0.42) use(1)#10 Wood Screw type installation anchors per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. Refer to Installation Instructions (NCTL210-3875-1-FBC)for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 65 PSF Negative 70 PSF Hermes F. Norero, P.E. Florida No.73778 Page 4 of 4 "'MAX � MIN.DISTANCE MASONRY INSTALLATION FROM FOR EDGE:21/2• CORNERS • Od4 J MASONRY Z BLOCK �- d j 1 va•MIN 15•D.C. v °3 I —MAX.THRU EMBEDMENT JAMB n j EMBEDMENT 1/4•MAX 1/4"MAX SHIM SPACE j Q 3 SHIM SPACE I MIN.DISTANCE V V _ imm FOR EDGE:21/2" a 2 V 3—��3mm v v &LASE 13.mm jMASONRY � BLOCK ' JAMB SECTION GLAZING DETAIL (TYP) HORIZONTAL SECTION FRAME SECTION(TYP) VERTICAL SECTION rarewnem...ewinyruy.ew..aoow",. i I SHIM SPACE I a MAX FRO II 4 1 NERS j V V u/a•MIN. q EMBEDMENT PREMIUM ATLANTIC VINYL SH WINDOW 2.4 MASONRY Max Frame OP RATING IMPACT j -wnNDOw wu�Tx W.uAx.) v.' BLOCK 36 x 72 +65/-70 YE5 TYPICAL ELEVATION WITH FASTENER SPACING MIN 0—CE FOR EDGE:2 112• LARGE MISSILE IMPACT Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use 3/16"ITW Tapcon or equivalent fasteners through frame with sufficient length to penetrate a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum of 1 1/4"into concrete or masonry at each location with a 21/2"min from edge distance.For Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. concrete (min.fc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). 2. All glazing shall conform to ASTM E1300. 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by to the structure. The host structure is the responsibility of the architect or engineer of record for the DuPont-3mm annealed. project of installation. 4. Use structural or composite shims where required. This schedule addresses only the fasteners required to anchor the ``11111111111 window to achieve the rated design pressure up to the size limitations ��� 11. noted. It is not intended as a guide to the installation process and does �o �� PROJECT ENGINEER: DATE: not address he sealing consideration that may arise in different wall .��� Q" •.••'••` •• • �i� -- 08/13/2014 JELDVEN 3737 Lakeport Blvd conditions. For the complete installation procedure,see the instructions ` .Z�;• ��� 0 DRAWN BY: SCALE: Klamath Falls,OR.97601 packaged with the window or go to 7 D.Vezo NTS Phone: (541)882-3451 =www.jeld-wen.com/resourceslinstallation. CHECKED BY: TITLE:_ * . * _ J. Kantola T T ilf = APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window DISCLAIMER: �J �/1� -- This drawing and its contents are confidential and are not to be I- �,� �ok PART 6 P o Eck Ow reproduced or copied in whole or in part or used or disclosed to others �i0 x > bfr ��� � � / � No 8 except as authorized by JELD-WEN Inc. 3e8 E to 338 IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET 2 OF 3 en NCTL210-3875- -FBC 00 14 BEDROOM DINNING LIVING BEDROOM t "YC $ KITCHEN Mrs HW Up www"� ❑ 11=:Zoo T� 0 k� GARAGE