Loading...
HomeMy WebLinkAboutNOTICE OF PRODUCT CERTIFICATION & EVALUATION REPORT NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: NI011567.04-R3 DATE: 05/23/2013 CERTIFICATION PROGRAM: Structural COMPANY: JELD-WEN . ` CODE: 1822-1 REVISION DATE: 01/13/2017 To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the product is active and currently listed.This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION JELD-WEN "Premium Atlantic Vinyl Single Hung(8100)" 3737 Lakeport Boulevard Impact Rated Vinyl Single Hung Window Klamath Falls, OR 97601 (Fin or Flange Installation) Configuration:O/X Glazing:IG-1/8"Annealed Glass/Laminate- 1/8"Annealed Glass/0.090"PVB Interlayer by DuPont/ 1/8"Annealed Glass or IG-I/8"Annealed Glass/Laminate- 1/8"annealedGlass/0.090"SentryGlas Plus by DuPont/ 1/8"Annealed Glass Frame: W-914mm(36") H-1829mm(72") Sash: W-845mm(33.25") H-883mm(34.75") SPECIFICATION PRODUCT RATING TAS 201/202/203-94 Design Pressure: +65/-70 psf Large Missile Impact Rated Product Tested By: National Certified Testing Laboratories Report No: NCTL-210-3875-1 Expiration Date: April 30,2025 FILE COPY Administrator's Signature: I NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes,VA 23072 Tel: (804) 684-5124 Fax: (804) 684-5122 398 E. Dania Beach Blvd. BUILDING DROPS q�.p�G rA- Suite338 Dania Beach, FL 33004 A Perfect Solution in Every Drop 954.399.8478 PH Certificate of Authorization:29578 954.744.4738 FX contact@buildingdrops.com Product Evaluation Report Of JELD-WEN, Inc. Premium Atlantic Vinyl Single Hung - Impact for Florida Product Approval Report No. 3091 Current Florida Building Code Method: 1 —A (Certificate) Category: Windows Sub — Category: Single Hung Product: Premium Atlantic Vinyl Single Hung-Impact Material: PVC Product Dimensions: 52-118"x 75"(O/X) ,Prepared For: JELD-WEN, Inc. 3737 Lakeport Blvd. Klamath Falls, OR 97601 Prepared by: Hermes F. Norero, P.E. SF O Florida Professional Engineer#73778 ��`�Q- .••' ' '• • �c` �i� Date: 08/11/2014 •'•.�O 7 Contents: Evaluation Report Pages 1 —4 Digitally signed by Hermes F.Norero,P.& c�`S,•''•••••••''•• C�� �•`� Reason:I am approving this document 111111110 ON,;E,,,%1 Date:2014.09.1916:31:16-04'00' Hermes F. Norero, P.E. Florida No. 73778 Date: 0o: 30014 BUILDING DROPS Report No: 91 6 A Perfect Solution in Every Drop Certificate of Authorization:29578 Manufacturer: JELD-WEN, Inc. Product Category: Windows Product Sub-Category: Single Hung Compliance Method: State Product Approval Method (1)(a) Product Name: Premium Atlantic Vinyl Single Hung-Impact 52-1/8" x 75" (O/X) Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN, Inc. based on Method 1a of the State of Florida Product Approval, Department of Business and Professional Regulation- Florida Building Commission. Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. This product has been evaluated for use in locations adhering to the current Florida Building Code. See Installation Instructions NCTL210-3874-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL# 73778)for specific use parameters. Limits of Use: 1. This product has been evaluated and is in compliance with the current Florida Building Code, including the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into substrate material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with Section 1609.1.2 of the current Florida Building Code and does not require an impact resistant covering. 4. Site conditions that deviate from the details of drawing NCTL210-3874-1-FBC require further engineering analysis by a licensed engineer or registered architect. 5. See Installation Instructions NCTL210-3874-1-FBC for size and design pressure limitations. Hermes F. Norero, P.E. Florida No.73778 Page 2 of 4 Date: 0 o: 30014 BUILDING DROPS Report No: 91 A Perfect Solution in Every Drop Certificate of Authorization:29578 Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the Florida Building Code for manufacturing under a quality assurance program audited by an approved quality assurance entity through National Accreditation and Management Institute (FBC Organization#: QUA 1789) Performance Standards: The product described herein has been tested per: • TAS 201-94 • TAS 202-94 • TAS 203-94 Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW (FBC Organization# TST9341) Report#: NCTL-210-3874-1, Report Date:4/18/2013 2. Certification Agency National Accreditation and Management Institute (FBC Organization#: CER 1773) 3. Material Certification Miami Dade RER—Product Control Section NOA E.I. DuPont De Nemours&Co., Inc.: PVB Interlayer 4. Material Certification Miami Dade RER—Product Control Section NOA Quanex Building Products: PVC Extrusions Hermes F. Norero, P.E. Florida No.73778 Page 3 of 4 Date: 0o: 30014 BUILDING DROPS Report No: 91 ® A Perfect Solution in Every Drop Certificate of Authorization:29578 Through Frame Installation: 1. Approved anchor types and substrates areas follows: A. For concrete (Min.f c=3000 psi) or masonry substrate (Min.fc= 1500 psi)where one by(1X), non-structural,wood bucking is employed, use (1)3/16"diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. B. For concrete (Min.fc=3000 psi) or masonry substrate (Min.fc= 1500 psi) where wood bucking is NOT employed, use (1)3/16" diameter ITW Tapcon type concrete screw anchors per location of sufficient length to achieve minimum embedment of 1.25" into concrete or masonry. C. For steel substrate, use(1)#8 Tek Screw type steel frame (min. 18ga.)anchors per location of sufficient length to achieve minimum three threads of penetration beyond steel structure. Nail Fin Installation(Where applicable): A. For wood substrates (Min.S.G. =0.42) use (1)#10 Wood Screw type installation anchors per location of sufficient length to achieve a minimum embedment of 1.50" into the wood substrate. Refer to Installation Instructions (NCTL210-3874-1413C)for anchor spacing and more details of the installation requirements. Design Pressure: Design Pressure Positive 50 PSF Negative 60 PSF Hermes F. Norero, P.E. Florida No.73778 Page 4 of 4 Ir O.C.MAX s s•,,,�,� SONRY INSTALLATION THRU JAMB N.M.MIN.DISTANCE w FROM FOR EDGE:2 1/2• CORNERS • F�J MASONRY 2 BLOCK �— 11/4•MIN. 1BA•O.C. V 3 EMBEDMENT MAIL 7HRU 4', JAMB 11 1/4'MIN. EMBEDMENT 1/4'MAX 5HIM SPACE SHI MAX Q 3 SHIM SPACE MIN.DISTANCE V V xmm FOR EDGE:21/2" v 2 UP 3— 3mm PFOR . a: 4 _ &LAS BITE 13.mm MASONRY BLOCK JAMB SECTION(TYP) GLAZING DETAIL HORIZONTAL SECTION FRAME SECTION(TYP) VERTICAL SECTION wren!mR e....H u.img�a a w..a ow.y. j 1/4'MAX SHIM SPACE � MAIL A. 4.. r FROM CORNERs 4a "� •• EMBEDMENT PREMIUM ATLANTIC VINYL 5H WINDOW OCCKKNRY Max Frame DP RATING IMPACT i -1N1 DOW WIDiH(52 118.MAX.) 52 1/8 x 75 +50/-60 YES F TYPICAL ELEVATION WITH FA5TENER SPACING OR DISTANCE EDGE:2 1/2' LARGE MISSILE IMPACT FOR Installation Notes: General Notes: 1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria 2. Use 3/16"ITW Tapcon or equivalent fasteners through frame with sufficient length to penetrate a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida minimum of 1 1/4"into concrete or masonry at each location with a 21/2"min from edge distance.For Building Code(FBC)including HVHZ and the industry requirement for the stated conditions. 2• All glazing shall conform to ASTM E1300. concrete (min.fc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90). annealed 3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by to the structure. The host structure is the responsibility of the architect or engineer of record for the DuPont-3mm annealed. 4. Use structural or composite shims where required. project of installation. This schedule addresses only the fasteners required to anchor the window to achieve the rated design pressure up to the size limitations noted. It is not intended as a guide to the installation process and does �ooto-. �� PROJECT ENGINEER: DATE: 3]3]Lakeport t Blvd not address he sealing consideration that may arise in different wall ,��� ��� -- 08/13/2014 JELDEN conditions. For the complete installation procedure,see the instructions : � �� 0 DRAWN BY: SCALE: Klamath Falls,OR.97601 packaged with the window or go to D.Vezo NTS Phone: (541)882-3451 CHECKED BY: TITLE: www.jeld-wen.com/resources/installation. J. Kantola [r = APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window DISCLAIMER: � 44/ ZThis drawing and its contents are confidential and are not to be � P RT P 0 ECT Dreproduced or copied in whole or in part or used or disclosed to others � . e ��'` 6G��72� except as authorized by JELD-WEN Inc. gees to gag IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET 2 OF 3 n NCTL210-3874- -FBC 00 7777 PRO volume Savings Program I� Quote#: 8899645 Volume Savings Expiration Date: ty312'1 Pi - Customer Name: mark Penrose i Selling System Quote Project qsp doors and windows Description: I Customer Phone#: 2487602812 Pricing is per Lowe's Store at: Store#240 VERO BEACH,FL Store Phone#: (772)564-6955 �� . Store Contact: Kenji Item# Quantity Item Description OSP Unit Extended.OSP Price Price 938893 1 Feather River Door 67.5 X80.5 k 2,732.58 2,732.58 938804 2 Feather River Door 59.5 X78.375 1,967.78 3,935.56 1418847 4 JW IMP FL2-4 35-314X49-N8 VSH WH, 275.94 1,103.76 1418848 1 JW IMP F1.3-3 51-7/8X37-1/8 VSH.WH 288.07 288.07. 1418850 2 JW IMP FL3-4 51-7/8X49-&8 VSH WH 328.12 656.24 215003 5 Howell Float 94.77 473.85 314409 10 1-4-12 TREATED APPEARANCEE GRADE 5.07 50.70 OSP Total:$9,240.76 Total savings for this quote is$2,226.27 i 'All items requested for volume savings may not be listed if they did not qualify for OSP savings. You Save 19.41% MANAGER SIGNATURE DATE i -THIS ESTIMATE IS NOT VALID WITHOUT A MANAGER'S SIGNATURE -LOWE'S RESERVES THE RIGHT TO LIMIT THE QUANTITIES OF MERCHANDISE SOLD TO CUSTOMERS `ALL OF THE PRODUCT MUST BE ORDERED BY THE EXPIRATION DATE IN ORDER TO RECEIVE VOLUME SAVINGS { 'THIS IS AN ESTIMATE ONLY.DELIVERY OF ALL MATERIALS CONTAINED IN THIS ESTIMATE ARE SUBJECT TO AVAILABILITY FROM THE MANUFACTURER OR SUPPLIER.QUANTITY,EXTENSION,OR ADDITION ERRORS ARE SUBJECTTO.CORRECTION.CREDIT . TERMS SUBJECT TO APPROVAL BY LOWE'S CREDIT DEPARTMENT. -LOWE'S IS A SUPPLIER OF MATERIALS ONLY.LOWE'S DOES NOT ENGAGE IN THE PRACTICE OF ENGINEERING,ARCHITECTURE;, OR GENERAL CONTRACTING.LOWE'S DOES NOT ASSUME SELECTION OR CHOICE OF MATERIALS FOR A GENERAL OR SPECIFIC USE;FOR QUANTITIES OR SIZING OF MATERIALS;FOR THE USE OR INSTALLATION OF MATERIALS;OR FOR COMPLIANCE WITH ANY BUILDING CODE OR STANDARD OF WORKMANSHIP. -LOWE'S IS MAKING THE FOLLOWING QUOTE BASED ON ITS STANDARD COMMERCIAL TERMS,AND DOES NOT AGREE TO TERMS I, AND CONDITIONS,INCLUDING ANY GOVERNMENTAL.REGULATIONS,NOT SPECIFICALLY INDICATED OR REFERENCED IN THE i' REQUEST FOR THIS QUOTATION.IF TERMS AND CONDITIONS ARE PRESENTED,PRODUCT SELECTION AND PRICING.MAY CHANGE I' PENDING LEGAL REVIEW. 'TAXES AND DELIVERY WILL BE ADDED AT TIME OF PURCHASE AS APPLICABLE. Visit LowesForPros.com Learn About All the Ways Lowe's Saves Your Business Time&Money -Business Credit i Delivery Volume Priarig Order Ahead i i