HomeMy WebLinkAboutNOTICE OF PRODUCT CERTIFICATION & EVALUATION REPORT NOTICE OF PRODUCT CERTIFICATION
CERTIFICATION NO: NI011567.04-R3
DATE: 05/23/2013
CERTIFICATION PROGRAM: Structural
COMPANY: JELD-WEN
. ` CODE: 1822-1
REVISION DATE: 01/13/2017
To verify that the"Notice of Product Certification"is valid,please visit www.NAMICertification.com to assure that the
product is active and currently listed.This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION
JELD-WEN "Premium Atlantic Vinyl Single Hung(8100)"
3737 Lakeport Boulevard Impact Rated Vinyl Single Hung Window
Klamath Falls, OR 97601 (Fin or Flange Installation)
Configuration:O/X
Glazing:IG-1/8"Annealed Glass/Laminate-
1/8"Annealed Glass/0.090"PVB Interlayer by DuPont/
1/8"Annealed Glass or IG-I/8"Annealed Glass/Laminate-
1/8"annealedGlass/0.090"SentryGlas Plus by DuPont/
1/8"Annealed Glass
Frame: W-914mm(36") H-1829mm(72")
Sash: W-845mm(33.25") H-883mm(34.75")
SPECIFICATION PRODUCT RATING
TAS 201/202/203-94 Design Pressure: +65/-70 psf
Large Missile Impact Rated
Product Tested By: National Certified Testing Laboratories
Report No: NCTL-210-3875-1
Expiration Date: April 30,2025 FILE
COPY
Administrator's Signature:
I
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes,VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122
398 E. Dania Beach Blvd.
BUILDING DROPS q�.p�G rA- Suite338
Dania Beach, FL 33004
A Perfect Solution in Every Drop 954.399.8478 PH
Certificate of Authorization:29578 954.744.4738 FX
contact@buildingdrops.com
Product Evaluation Report
Of
JELD-WEN, Inc.
Premium Atlantic Vinyl Single Hung - Impact
for
Florida Product Approval
Report No. 3091
Current Florida Building Code
Method: 1 —A (Certificate)
Category: Windows
Sub — Category: Single Hung
Product: Premium Atlantic Vinyl Single Hung-Impact
Material: PVC
Product Dimensions: 52-118"x 75"(O/X)
,Prepared For:
JELD-WEN, Inc.
3737 Lakeport Blvd.
Klamath Falls, OR 97601
Prepared by:
Hermes F. Norero, P.E. SF O
Florida Professional Engineer#73778 ��`�Q- .••' ' '• • �c` �i�
Date: 08/11/2014 •'•.�O
7
Contents:
Evaluation Report Pages 1 —4
Digitally signed by Hermes F.Norero,P.& c�`S,•''•••••••''•• C�� �•`�
Reason:I am approving this document 111111110
ON,;E,,,%1
Date:2014.09.1916:31:16-04'00'
Hermes F. Norero, P.E.
Florida No. 73778
Date: 0o: 30014
BUILDING DROPS
Report No: 91
6 A Perfect Solution in Every Drop
Certificate of Authorization:29578
Manufacturer: JELD-WEN, Inc.
Product Category: Windows
Product Sub-Category: Single Hung
Compliance Method: State Product Approval Method (1)(a)
Product Name: Premium Atlantic Vinyl Single Hung-Impact
52-1/8" x 75" (O/X)
Scope: This is a Product Evaluation Report issued by Hermes F. Norero, P.E. (FL#73778)for JELD-WEN, Inc.
based on Method 1a of the State of Florida Product Approval, Department of Business and
Professional Regulation- Florida Building Commission.
Hermes F. Norero, P.E. does not have nor will acquire financial interest in the company
manufacturing or distributing the product or in any other entity involved in the approval process of
the product named herein.
This product has been evaluated for use in locations adhering to the current Florida Building Code.
See Installation Instructions NCTL210-3874-1-FBC, signed and sealed by Hermes F. Norero, P.E. (FL#
73778)for specific use parameters.
Limits of Use:
1. This product has been evaluated and is in compliance with the current Florida Building Code,
including the "High Velocity Hurricane Zone" (HVHZ).
2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment into
substrate material shall be beyond wall dressing or stucco.
3. When used in areas requiring wind borne debris protection this product complies with
Section 1609.1.2 of the current Florida Building Code and does not require an impact
resistant covering.
4. Site conditions that deviate from the details of drawing NCTL210-3874-1-FBC require further
engineering analysis by a licensed engineer or registered architect.
5. See Installation Instructions NCTL210-3874-1-FBC for size and design pressure limitations.
Hermes F. Norero, P.E.
Florida No.73778
Page 2 of 4
Date: 0 o: 30014
BUILDING DROPS
Report No: 91
A Perfect Solution in Every Drop
Certificate of Authorization:29578
Quality Assurance: The manufacturer has demonstrated compliance of products in accordance with the
Florida Building Code for manufacturing under a quality assurance program audited
by an approved quality assurance entity through National Accreditation and
Management Institute (FBC Organization#: QUA 1789)
Performance Standards: The product described herein has been tested per:
• TAS 201-94
• TAS 202-94
• TAS 203-94
Referenced Data: 1. Product Testing performed by National Certified Testing Laboratories NW
(FBC Organization# TST9341)
Report#: NCTL-210-3874-1, Report Date:4/18/2013
2. Certification Agency
National Accreditation and Management Institute
(FBC Organization#: CER 1773)
3. Material Certification
Miami Dade RER—Product Control Section NOA
E.I. DuPont De Nemours&Co., Inc.: PVB Interlayer
4. Material Certification
Miami Dade RER—Product Control Section NOA
Quanex Building Products: PVC Extrusions
Hermes F. Norero, P.E.
Florida No.73778
Page 3 of 4
Date: 0o: 30014
BUILDING DROPS
Report No: 91
® A Perfect Solution in Every Drop
Certificate of Authorization:29578
Through Frame Installation: 1. Approved anchor types and substrates areas follows:
A. For concrete (Min.f c=3000 psi) or masonry substrate (Min.fc= 1500 psi)where one
by(1X), non-structural,wood bucking is employed, use (1)3/16"diameter ITW Tapcon
type concrete screw anchors per location of sufficient length to achieve minimum
embedment of 1.25" into concrete or masonry.
B. For concrete (Min.fc=3000 psi) or masonry substrate (Min.fc= 1500 psi) where wood
bucking is NOT employed, use (1)3/16" diameter ITW Tapcon type concrete screw
anchors per location of sufficient length to achieve minimum embedment of 1.25" into
concrete or masonry.
C. For steel substrate, use(1)#8 Tek Screw type steel frame (min. 18ga.)anchors per
location of sufficient length to achieve minimum three threads of penetration beyond
steel structure.
Nail Fin Installation(Where applicable):
A. For wood substrates (Min.S.G. =0.42) use (1)#10 Wood Screw type installation anchors
per location of sufficient length to achieve a minimum embedment of 1.50" into the
wood substrate.
Refer to Installation Instructions (NCTL210-3874-1413C)for anchor spacing and more details of the
installation requirements.
Design Pressure:
Design Pressure
Positive 50 PSF
Negative 60 PSF
Hermes F. Norero, P.E.
Florida No.73778
Page 4 of 4
Ir O.C.MAX s s•,,,�,� SONRY INSTALLATION
THRU JAMB N.M.MIN.DISTANCE w
FROM FOR EDGE:2 1/2•
CORNERS
• F�J
MASONRY
2 BLOCK �—
11/4•MIN.
1BA•O.C. V 3 EMBEDMENT
MAIL 7HRU 4',
JAMB 11 1/4'MIN.
EMBEDMENT
1/4'MAX
5HIM SPACE SHI MAX
Q 3 SHIM SPACE
MIN.DISTANCE V V
xmm FOR EDGE:21/2" v 2 UP
3— 3mm PFOR .
a:
4
_ &LAS BITE
13.mm
MASONRY
BLOCK
JAMB SECTION(TYP)
GLAZING DETAIL HORIZONTAL SECTION
FRAME SECTION(TYP)
VERTICAL SECTION
wren!mR e....H u.img�a a w..a ow.y.
j 1/4'MAX
SHIM SPACE �
MAIL A. 4..
r FROM
CORNERs 4a "� •• EMBEDMENT PREMIUM ATLANTIC VINYL 5H WINDOW
OCCKKNRY Max Frame DP RATING IMPACT i
-1N1 DOW WIDiH(52 118.MAX.) 52 1/8 x 75 +50/-60 YES
F
TYPICAL ELEVATION WITH FA5TENER SPACING OR DISTANCE EDGE:2 1/2' LARGE MISSILE IMPACT
FOR
Installation Notes: General Notes:
1. Seal flange/frame to substrate. 1. The product shown herein is designed,tested and manufactured to comply with the wind load criteria
2. Use 3/16"ITW Tapcon or equivalent fasteners through frame with sufficient length to penetrate a of the adopted International Building Code(IBC),the International Residential Code(IRC),the Florida
minimum of 1 1/4"into concrete or masonry at each location with a 21/2"min from edge distance.For Building Code(FBC)including HVHZ and the industry requirement for the stated conditions.
2• All glazing shall conform to ASTM E1300.
concrete (min.fc=3000psi)or masonry substrate(CMU shall adhere to ASTM C90).
annealed
3. Host structure(wood buck,masonry,steel)to be designed and anchored to properly transfer all loads 3. At minimum,glazing is 3mm annealed-11 mm airspace-3mm annealed-2mm PVB Interlayer by
to the structure. The host structure is the responsibility of the architect or engineer of record for the DuPont-3mm annealed.
4. Use structural or composite shims where required.
project of installation.
This schedule addresses only the fasteners required to anchor the
window to achieve the rated design pressure up to the size limitations
noted. It is not intended as a guide to the installation process and does �ooto-.
�� PROJECT ENGINEER: DATE: 3]3]Lakeport
t Blvd
not address he sealing consideration that may arise in different wall ,��� ��� -- 08/13/2014 JELDEN
conditions. For the complete installation procedure,see the instructions : � �� 0 DRAWN BY: SCALE: Klamath Falls,OR.97601
packaged with the window or go to D.Vezo NTS Phone: (541)882-3451
CHECKED BY: TITLE:
www.jeld-wen.com/resources/installation. J. Kantola
[r = APPROVED BY: Premium Atlantic Vinyl Impact Single Hung Window
DISCLAIMER: � 44/ ZThis drawing and its contents are confidential and are not to be � P RT P 0 ECT Dreproduced or copied in whole or in part or used or disclosed to others � . e ��'` 6G��72�
except as authorized by JELD-WEN Inc. gees to gag IDENTIFIER No. PLANT NAME AND LOCATION: CAD DWG.No.: REV: SHEET 2 OF 3
n NCTL210-3874- -FBC 00
7777
PRO volume Savings Program I�
Quote#: 8899645
Volume Savings Expiration Date: ty312'1
Pi -
Customer Name: mark Penrose
i
Selling System Quote Project qsp doors and windows
Description:
I
Customer Phone#: 2487602812
Pricing is per Lowe's Store at: Store#240
VERO BEACH,FL
Store Phone#: (772)564-6955 �� .
Store Contact: Kenji
Item# Quantity Item Description OSP Unit Extended.OSP
Price Price
938893 1 Feather River Door 67.5 X80.5 k 2,732.58 2,732.58
938804 2 Feather River Door 59.5 X78.375 1,967.78 3,935.56
1418847 4 JW IMP FL2-4 35-314X49-N8 VSH WH, 275.94 1,103.76
1418848 1 JW IMP F1.3-3 51-7/8X37-1/8 VSH.WH 288.07 288.07.
1418850 2 JW IMP FL3-4 51-7/8X49-&8 VSH WH 328.12 656.24
215003 5 Howell Float 94.77 473.85
314409 10 1-4-12 TREATED APPEARANCEE GRADE 5.07 50.70
OSP Total:$9,240.76
Total savings for this quote is$2,226.27
i
'All items requested for volume savings may not be listed if they did not qualify for OSP savings. You Save 19.41%
MANAGER SIGNATURE DATE
i
-THIS ESTIMATE IS NOT VALID WITHOUT A MANAGER'S SIGNATURE
-LOWE'S RESERVES THE RIGHT TO LIMIT THE QUANTITIES OF MERCHANDISE SOLD TO CUSTOMERS
`ALL OF THE PRODUCT MUST BE ORDERED BY THE EXPIRATION DATE IN ORDER TO RECEIVE VOLUME SAVINGS {
'THIS IS AN ESTIMATE ONLY.DELIVERY OF ALL MATERIALS CONTAINED IN THIS ESTIMATE ARE SUBJECT TO AVAILABILITY FROM
THE MANUFACTURER OR SUPPLIER.QUANTITY,EXTENSION,OR ADDITION ERRORS ARE SUBJECTTO.CORRECTION.CREDIT .
TERMS SUBJECT TO APPROVAL BY LOWE'S CREDIT DEPARTMENT.
-LOWE'S IS A SUPPLIER OF MATERIALS ONLY.LOWE'S DOES NOT ENGAGE IN THE PRACTICE OF ENGINEERING,ARCHITECTURE;,
OR GENERAL CONTRACTING.LOWE'S DOES NOT ASSUME SELECTION OR CHOICE OF MATERIALS FOR A GENERAL OR SPECIFIC
USE;FOR QUANTITIES OR SIZING OF MATERIALS;FOR THE USE OR INSTALLATION OF MATERIALS;OR FOR COMPLIANCE WITH
ANY BUILDING CODE OR STANDARD OF WORKMANSHIP.
-LOWE'S IS MAKING THE FOLLOWING QUOTE BASED ON ITS STANDARD COMMERCIAL TERMS,AND DOES NOT AGREE TO TERMS I,
AND CONDITIONS,INCLUDING ANY GOVERNMENTAL.REGULATIONS,NOT SPECIFICALLY INDICATED OR REFERENCED IN THE i'
REQUEST FOR THIS QUOTATION.IF TERMS AND CONDITIONS ARE PRESENTED,PRODUCT SELECTION AND PRICING.MAY CHANGE I'
PENDING LEGAL REVIEW.
'TAXES AND DELIVERY WILL BE ADDED AT TIME OF PURCHASE AS APPLICABLE.
Visit LowesForPros.com
Learn About All the Ways Lowe's Saves
Your Business Time&Money
-Business Credit
i
Delivery
Volume Priarig
Order Ahead
i
i