HomeMy WebLinkAboutAPPROVED, ENERGY CALCS & MANUAL J - 20 FLORES DEL NORTEFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE BU€DLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE
Permit Office: ST_ LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner. WYNNE BUILDING CORP.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie(Florida Climate Zone 2)
1. New construction or existing New (From Plans)
10. Wall Types(1718.3 sqft.)
Insulation Area
2. Single family or multiple family
Detached
a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2
b. Frame - Wood, Adjacent
R=11.0 240.00 ft
3. Number of units, if multiple family
1
c. NIA
R= ft2
4. Number of Bedrooms
1
d. NIA
R= ft2
5. Is this a worst case?
Yes
11. Ceiling Types(1336.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1306.00 ft2
6. Conditioned floor area above grade (ft2)
1306
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2)
0
c. NIA
R= ft2
7. Windows(128.9 sqft.) Description
Area
12_ Ducts, location & insulation level R ft2
a. U-Factor: 591, U=1.02
76.04 ft2
a. a. Sup: Attic, Ret: Attic, AH:
Attic 6 120
5h1GG: 5€10G=0.29
b.
b. U-Factor: Sol, U=1.03
40.00 ft2
C.
SHGC: SHGC=0.27
13. Cooling Systems
kBtu/hr Efficiency
c. U-Factor: Sgl, U=1.02
12.85 ft2
a. Central Unit
29.0 SEER:14.00
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
4.701 ft
Area Weighted Average SHGC:
0.281
14. Heating Systems
kBtulhr Efficiency
8. Skylights Description
Area
a. Electric Heat Pump
27.0 HSPF:8.20
U-Factor.(AVG) NIA
NIA ft2
SHGC(AVG): NIA
9. Floor Types Insulation
Area
15. Hot Water Systems
a. Slab -On -Grade Edge Insulation R= 0.0
2
1306.00 ft2
a. ElectricTankless
Cap: 1 gallons
EF: 0.600
c. N/A R=
ft2
b. Conservation features
None
16. Credits
None
Glass/Floor Area: 0.099 Total Proposed Modified Loads: 41.30
Total Baseline Loads: 43.21
PASS
I hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this��
Code.
calculation indicates compliance®gyp
'
with the Florida Energy Code.�-
PREPARED BY.
Before construction is completed
Rill
(3'7'2021
this building will be inspected for
aG ._:..__ _. t3
0 �'
DATE:
compliance with Section 553.908
Florida Statutes.
'
hereby certify that this building, as designed, is '
compliance
�OAWE
with the Florida Energy Ce�3er�
OWNER/A E T:
BUILDING OFFICIAL:
DATE: N,l
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct
leakage to outdoors, tested in accordance with ANSI/RESNETIICC 380, is not greater than 0.000 On for whole house.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project
requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE BUIDLING-THE COTTAGE IMPACT
Addresstype:
Street Address
Building Type: User
Bedrooms: 1
Lot#:
-
Owner: WYNNE BUILDING CORP.
Conditioned Area: 1306
Block/SubDivision: -
TotalStories: 1
PlatBook:
Builder Name: WYNNE BUILDING CORP.
Worst Case: Yes
Street:
THE COTTAGE
Permit Office: ST. LUCIE COUNTY
Rotate Angle: 180
County:
St. Lucie
Jurisdiction:
Cross Ventilation: No
City, State, Zip:
FT. PIERCE,
FamilyType: Detached
Whole House Fan: No
FL,
New/Existing: New (From Plans)
Terrain: Suburban
YearConstruct:
Shielding: Suburban
Comment:
CLIMATE
Design
Design Temp
Int Design Temp
Heating
Design
Dailytemp
Location
Tmy Site
97.5% 2.5%
Winter Summer
Degree Days
Moisture
Range
FL, Fort Pierce
FL_VERO_BEACH_MUNICIPA 39 90
70 75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 Entire House
13M76.2001953125
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Finished
Cooled
Heated
_ 1 MASTER BEDROOM
234
1895.4 No 0
1
Yes
Yes
Yes
_2 DEN
144
1166.4 No 0
Yes
Yes
Yes
_3 SINK AREA
42
340.2 No 0
Yes
Yes
Yes
_4 CLOSET
63
510.3 No 0
No
Yes
Yes
_ 5 GREAT ROOM
452
3661.2 No 2
Yes
Yes
Yes
_ 6 MASTER BATH
50
405 No 0
Yes
Yes
Yes
_7 POWDER
25
202.5 No 0
No
Yes
Yes
_8 KITCHEN
232
1879.2 Yes 0
Yes
Yes
Yes
_9 LAUNDRY
40
324 No 0
No
Yes
Yes
_10 STORAGE
24
192 No 0
0
Yes
Yes
Yes
FLOORS
(Total Exposed Area = 1306 sq.ft.)
# Floor Type
Space
Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value
Tile Wood Carpet
_ 1 Slab -On -Grade Edge Ins
MASTER BEDROOM 31 0
234 ft 0.473
-
0.00
1.00 0.00
_2 Slab -On -Grade Edge Ins
DEN
24 0
144ft 0.473
-
0.00
1.00 0.00
_3 Slab -On -Grade Edge Ins
SINKAREA
7 0
42ft 0.473
-
0.00
1.00 0.00
_4 Slab -On -Grade Edge Ins
CLOSET
1 0
63ft 0.473
-
0.00
1.00 0.00
_ 5 Slab -On -Grade Edge Ins
GREAT ROOM
32 0
452 ft 0.473
-
0.00
1.00 0.00
_ 6 Slab -On -Grade Edge Ins
MASTER BATH
5 0
50 ft 0.473
-
0.00
1.00 0.00
_7 Slab -On -Grade Edge Ins
POWDER
1 0
25ft 0.473
-
0.00
1.00 0.00
_ 8 Slab -On -Grade Edge Ins
KITCHEN
38 0
232 ft 0.473
-
0.00
1.00 0.00
_ 9 Slab -On -Grade Edge Ins
LAUNDRY
1 0
40 ft 0.473
-
0.00
1.00 0.00
10 Slab -On -Grade Edge Ins
STORAGE
21 0
24ft 0.304
-
0.00
0.00 1.00
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2
FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT
ROOF
/
Roof Gable Roof
Red
Solar
SA Emitt Emitt
Deck Pitch
V# Type
Materials Area Area Color
Barr Absor. Tested Tested
Insul. (deg)
1 Hip
Metal 1376 ft2 0 ft2 Light
N
0.6
No 0.9 No
0 18.4
ATTIC
# Type
Ventilation Vent Ratio (1 in) Area
RBS
IRCC
1 Full attic
Vented 150 1306 fe
N
N
CEILING
(Total Exposed Area = 1336 sq.ft.)
# Ceiling Type
Space R-Value Ins.Type
Area
U-Factor Framing Frac.
Truss Type
1 UnderAttio(Vented)
MASTER BEDROOM 30.0 Blown
234.0ft2
0.053
0.10
Wood
_2 UnderAtic(Vented)
DEN 30.0 Blown
144.0ft2
0.053
0.10
Wood
_3 UnderAttic(Vented)
SINK AREA 30.0 Blown
42.Oft2
0.053
0.10
Wood
_4 UnderAttic(Vented)
CLOSET 30.0 Blown
63.0ft
0.053
0.10
Wood
_5 UnderAttio(Vented)
GREAT ROOM 30.0 Blown
452.Oft2
0.063
0.10
Wood
_6 UnderAttic(Vented)
MASTER BATH 30.0 Blown
50.0ft2
0.053
0.10
Wood
_7 UnderAftic(Vented)
POWDER 30.0 Blown
25.Oft2
0.053
0.10
Wood
_8 UnderAftic(Vented)
KITCHEN 30.0 Blown
232.Oft2
0.053
0.10
Wood
_9 UnderAtUc(Vented)
LAUNDRY 30.0 Blown
40.0R2
0.053
0.10
Wood
_ 10 UnderAttic(Vented)
STORAGE 30.0 Blown
24.Oft2
0.030
0.11
Wood
11 Knee Wall(Vented)
GREAT ROOM 19.0 Blown
30.0ft2
0.045
0.11
Wood
WALLS
(Total Exposed Area = 1718 sq.ft.)
Note: First wall orientation below is as entered.
Actual orientation is modified by the rotate angle (180 degrees)
as shown
in the "Project" section
on page 1.
/ Adjacent
Cavity Width
Height
Area
U- Sheath Fnn.
Solar Below
�/ # Ornt To
Wall Type
Space RValue Ft In
Ft In
sq.ft.
Factor R-Value Frac.
Absor. Grade
1 S=>N Exterior
Conc. Bik- Int Ins
MASTER BEDROOM 4.1 18.0 0
8.0 1
145.5
0.149 0 0
0.30 0%
_2 W=>E Exterior
Conc. Bilk - Int Ins
MASTER BEDROOM 4.1 13.0 0
8.0 1
105.1
0.149 0 0
0.30 0%
3 N=>S Exterior
Conc. Bilk - Int Ins
DEN 4.1 12.0 0
8.0 1
97.0
0.149 0 0
0.30 0%
_4 W=>E Exterior
Conc. Bik- Intlns
DEN 4.1 12.0 0
8.0 1
97.0
0.149 0 0
0.30 0%
_5 S=>N Exterior
Conc. Blk- Intlns
SINKAREA 4.1 7.0 0
8.0 1
56.6
0.149 0 0
0.30 0%
6 N=>S Exterior
Conc. Bik - Int Ins
GREAT ROOM 4.1 22.0 0
8.0 1
177.8
0.149 0 0
0.30 0%
_7 W=>E Exterior
Conc. Bik- Intlns
GREAT ROOM 4.1 10.0 0
8.0 1
80.8
0.149 0 0
0.30 0%
6 S=>N Exterior
Conc. Bik- Int Ins
MASTER BATH 4.1 5.0 0
8.0 1
40.4
0.149 0 0
0.30 0%
_9 N=>S Exterior
Conc.Bik- Intlns
KITCHEN 4.1 17.0 0
8.0 1
137.4
0.149 0 0
0.30 0%
_ 10 E=>W Exterior
Conc. Bik- Int Ins
KITCHEN 4.1 16.0 0
8.0 1
129.3
0.149 0 0
0.30 0%
_11 S=>N Exterior
Conc. Bik- Intlns
KITCHEN 4.1 5.0 0
8.0 1
40.4
0.149 0 0
0.30 0%
_12 N=>S Exterior
Conc. Bik-Intlns
KITCHEN 4.1 35.0 0
8.0 1
282.9
0.149 0 0
0.30 0%
_ 13 N=>S Exterior
Conc. BIk- Int Ins
STORAGE 4.1 6.0 0
8.0 0
48.0
0.149 0 0
0.30 0%
_ 14 NHS Exterior
Conc. Bilk - Int Ins
STORAGE 4.1 5.0 0
8.0 0
40.0
0.149 0 0
0.30 0%
_ 15 N=>S Garage
Frame - Wood
MASTER BEDROOM 11.0 30.0 0
8.0 0
240.0
0.092 0 0.23
0.30 0%
DOORS
(Total Exposed Area = 20 sq.ft.)
Width Height
# Omt Adjacent To
Door Type
Space Storms
U-Value
Ft
In Ft In
Area
1 E=>W
Insulated
KITCHEN None
0.32
3.00
0 6.00 8
20.OR2
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3
FORM R4O5-2020 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
(Total Exposed Area = 129 sq.ft.)
/ Wall
-Overhang-
/ # Omt ID Frame
Panes
NFRC U-Factor SHGC Imp Storm Area
Depth Separation InteriorShade
Screening
-1 W=>E 2 Metal
Low-E Single
Yes 1.02
0.29 N N 32.412
1.0 ft 5 in 1.0 It 5 in None
None
_ 2 W=>E 4 Metal
Low-E Single
Yes 1.02
0.29 N N 18.4ft2
1.0 It 5 in 1.0 ft 5 in None
None
- 3 N=>S 6 Metal
Low-E Single
Yes 1.02
0.29 N N 18.4ft
1.0 ft 5 in 1.0 ft 5 in None
None
_4 W=>E 7 Metal
Low-E Single
Yes 1.03
0.27 N N 40.0R2
12.0 ft0 in 1.0 ft5 in None
None
_5 S=>N 8 Metal
Low-E Single
Yes 1.02
029 N N 6.W
1.0 It in 1.O It in None
None
_ 6 E=>W 10 Metal
Low-E Single
Yes 1.02
0.26 N N 12.8ft1.0
It 5 in 1.0 ft 5 in None
None
INFILTRATION
# Scope Method
SLA CFM50 ELA EgLA
ACH ACH50 Space(s)
1 Wholehouse Proposed ACH(50)
0.00026
881 48.35 90.78
0.0907 5.0 All
GARAGE
# Floor Area
Roof Area
Exposed Wall Perimeter
Avg. Wall Height Exposed Wall Insulation
1 280 ft'
280 W
35 ft
8 it 11
MASS
# Mass Type
Area
Thickness FumitureFraction Space
_ 1 Default(8lbs/sq.fL)
0 ft2
Oft
0.30 MASTER BEDROOM
_ 2 Default(8lbs/sq.fL)
0 ft2
Oft
0.30 DEN
_ 3 Default(8lbs/sq.ft.)
0 ft'
Oft
0.30 SINK AREA
_4 Default(albs/sq.ft.)
0ft'
0ft
0.30 CLOSET
-5 Default(8 lbs/sq.ft.)
0 ft.
Oft
0.30 GREAT ROOM
_6 Default(81bs/sq.ft.)
0 ft'
Oft
0.30 MASTER BATH
_7 Default(8lbs/sq.ft.)
0 ft2
Oft
0.30 POWDER
-8 Default(8lbs/sq.fL)
0 ft2
Oft
0.30 KITCHEN
_ 9 Default(8 lbs/sq.ft.)
0 ft2
Oft
0.30 LAUNDRY
-10 Default(8lbs/sq.ft.)
0 ft'
Oft
0.30 STORAGE
HEATING SYSTEM
# System Type
Subtype/Speed
AHRI# Efficiency Capacity --GeotherrnalHeatPump- Ducts
Block
kBtu/hr Entry Power Volt Current
1 Electric Heat Pump
Split/Single
HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1
1
COOLING SYSTEM
# System Type
Subtype/Speed
AHRI # Efficiency
Capacity Air Flow SHR Duct
Block
kBtu/hr cfm
-1 Central Unit
SplittSingle
SEER:14.0 29.0 0 0.80 sys#1
1
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4
FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
Subtype
Location
EF(UEF) Cap Use
SetPnt
Fixture Flow Pipe Ins.
Pipe length
_ 1 Electric
Tankless
Garage
0.60 (0.60) 1.00 gal 61 gal
120 deg
Standard
None
82
Recirculation
Recirc
Control
Loop Branch Pump DWHR
Facilities Equal DWHR
OtherCredits
System
Type
length length power
Connected Flow
Eff
1 No
NA NA NA No
NA
NA NA
None
DUCTS
—Supply—--Return—
Air
CFM 25 CFM 25
HVAC #
VDuct
# Location
R-Value Area Location R-Value Area Leakage Type
Handler
TOT OUT
ON
RLF Heat Cool
1 Attic
6.0 120 fF
Attic
6.0 45 ft' Default Leakage
Attic
(Default) (Default)
TEMPERATURES
Programable Thermostat: N
Ceiling Fans: N
Cooling [ ] Jan
[] Feb
[I Mar
[I Apr
[ ] May [X] Jun [X] Jul
Pq Aug
[X] Sep [ ] Oct
[]
Nov Dec
[ ]
Heating [X] Jan
[X] Feb
[X] Mar
[ ] Apr
[ ] May [ j Jun (I Jul
[ ] Aug
[ ] Sep [ ] Oct
[Xj Nov [X] Dec
Venting [ ] Jan
[] Feb
[X] Mar
[X] Apr
[ ] May [ ] Jun []Jul
[ 1 Aug
[ 1 �P [XI Oct
[X] Nov [ ]Dec
Schedule: HERS 2006 Reference
Hours
VThermostat
Schedule Type
1
2
3 4 5 6
7
8 9
10
11 12
_Cooling(IND)
AM
78
78
78 78 78 78
78
78 78
78
78 78
PM
78
78
78 78 78 78
78
78 78
78
78 78
_ Cooling (WEH)
AM
78
78
78 78 78 78
78
78 78
78
78 78
PM
78
78
78 78 78 78
78
78 78
78
78 78
_ Heating (WD)
AM
68
68
68 68 68 68
68
68 68
68
68 68
PM
68
68
68 68 68 68
68
68 68
68
68 68
_ Heating (WEH)
AM
68
68
68 68 68 68
68
68 68
68
68 68
PM
68
68
68 68 68 68
68
68 68
68
68 68
6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
Owner: WYNNE BUILDING CORP. Jurisdiction: U
Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air-permeableinsulationshall
requirements
The exteriorthermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks orjoints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per
Knee walls shall be sealed.
inch minimum
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alig nment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
anddoom
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
andcantilevered
shall be permitted to be in contact with the top side
floors)
ofsheathing, orcontinuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered
Where provided instead of floor insulation, insulation
with a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Narrowcavities
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garageseparation
Air sealing shall be provided between the garage and
conditionedspaces.
Recessedlighting
Recessed light fixtures installed in the building thermal
Recessed lig ht fixtures installed in the building
envelope shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers
Exterior walls adjacent to showers and tubs shall
onexteriorwall
and tubs shall separate them from the showers and tubs.
beinsulated.
Electrical/phonebox
The air barrier shall be installed behind electrical or
on exteriorwalls
communication boxes orair-sealed boxes shall be installed.
HVAC register boo
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering
or ceiling penetrated by the boot.
Concealed
When required to be sealed, concealed fire sprinklers shall only
sprinklers
be sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
voids between fire sprinkler cover plates and walls or ceilings.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 96
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area above grade (f:2)
Conditioned floor area below grade (W)
7. Windows" Description
a. U-Factor: S91, U=1.02
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.03
SHGC: SHGC=0.27
c. U-Factor: SgI, U=1.02
SHGC: SHGC=0.26
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
THE COTTAGE,FT. PIERCE,FL,
New (From Plans)
Detached
1
1
Yes
1306
0
Area
76.04 fe
40.00 e
8. Skylights Description
U-Factor(AVG) N/A
SHGC(AVG): N/A
9. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R= 0.0
b. N/A R=
c. N/A R=
12.85 ftZ
4.701 ft
0.281
Area
N/A ft2
Area
1306.00 fe
ft2
ftZ
10.
Wall Types(1718.3 sqft.)
Insulation
Area
a. Concrete Block - Int Insul, ExteriorR=4.1
1478.30 ft2
b. Frame - Wood, Adjacent
R=11.0
240.00 ft2
c. N/A
R=
ft2
d. N/A
R=
ftZ
11.
Ceiling Types(1336.0 sgft)
Insulation
Area
a. Under Attic (Vented)
R=30.0
1306.00 flz
b. Knee Wall (Vented)
R=19.0
30.00 ftZ
c. N/A
R=
ftZ
12.
Ducts, location & insulation level
R ftZ
a. a. Sup: Attic, Ret Attic, AH: Attic
6 120
b.
c.
13.
Cooling Systems
kBtu/hr
Efficiency
a. Central Unit
29.0 SEER:14.00
14.
Heating Systems
kBtu/hr
Efficiency
a. Electric Heat Pump
27.0
HSPF:8.20
15. Hot Water Systems
a. ElectricTankless Cap: 1 gallons
EF: 0.600
b. Conservation features
None
16. Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: �- Date:
Address of New Home: THE COTTAGE City/FL Zip: FT. PIERCE,FL,
Ao F���S . nk 3s lii,
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for
energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the
Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6772021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
wrightsoftm Project Summary ata:
Entire House By.
QUICK CALCS, INC.
317 SL LUCIE LANE, FORT PIERCE, FL34946 Phore: 772-4666799 E=il:QUICKCALCS@AOL.COM
Project• •
For. WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
Notes:
Design Information
Weather. Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
90
OF
Inside db 70
OF
Inside db
75
OF
Design TD 28
OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grflb
Heating Summary
Sensible Cooling Equipment Load
Sizing
Structure 16327
Bbuh
Structure
15522
Btuh
Duds 4013
Central vent (0 cfm) 0
Btuh
Btuh
Duds
Central vent (0 cim)
5251
0
Btuh
Btuh
none
e)
Humidification 0
Biuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 20340
Btuh
Use manufacturers data
n
Infiltration
Rate/swing multiplier
Equipment sensible load
0.95
19734
Btuh
Method Simplified
Construction quality Average
Latent Cooling Equipment Load Sizing
Fireplaces
0
Structure
2094
Btuh
Ducts
1524
Btuh
Central vent (0 cfm)
0
Btuh
Heatin
AreaEquipment
Cooling
(none)
latent load
3618
Btuh
Molum) e(fV) 10579
10579
Airchanges/hour 0.45
023
Equipment Total Load (Sen+Lat)
23352
Btuh
Equiv. ANF (cfm) 79
41
Req. total capacity at 0.70 SHR
2.3
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Make Carrier
Trade CARRIER
Trade CARRIER
Model CH14NBO3000GOA0
Cond CH14NBO3000GOA0
AHRI ref 9162387
Coil FX4DNBO43L
AHRI ref 9162387
Efficiency 8.2 HSPF
Efficiency 11.5 EER,14
SEER
Heating input
Sensible Cooling
20300
Btuh
Heating output 28000
Btuh@470F
Latentcooling
8700
Btuh
Temperature rise 26
OF
Total cooling
29000
Biuh
Actual airflow 967
ctin
Actual airflow
967
chm
Airflowfactor 0.048
dm/Btuh
Airflowfactor
0.047
cfm/Btuh
Static pressure 0.50
in H2O
Static pressure
0.50
in H2O
Space thermostat
Load sensible heat ratio
0.85
Capacity balance point = 34 OF
Backup:
Input = 5 kW, Output=18005 Btuh,100 AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
wrightsaft- 2021-Jan121321:40
� j�. �..,.... RigIlSute�J Uriversal 201919.021 RSU08101 Page 1
/^^-�^...\WrigF6oftHJAC\WVNNEBUIDLING-THECOTTAGE.np Calc=MJB FrorlDoorfaces:SW
wdghtsoW RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. BY
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772466-6799 Email: Ol11CKCALCS@AOL.COM
1
Room name
EntireHouse
MASTER BEDROOM
2
Elposedwell
145.0 It
31.0 It
3
Room height
8.1 It
8.1 It heat(=]
4
Room dimensons
130 x 18.0 ft
5
.Room area
1306.0 ff
2340 IF
Ty
Cons7rudon
U-value
Or
HTM
Area
(n
Load
number
(BWh4F2F)
(BWhMt�
or perimeter (ft)
(BWh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
WPIS
Heat
Cool
Gross
NIPS
Heat
Cool
6
1q/
13A4o
0.143
n
4.00
2.19
446
427
1710
934
0
0
0
0
�G
29laang,droutr,
1.040
n
29.12
21.68
18
0
537
400
0
0
0
- 0
13A4o s
0.143
a
4.00
2.19
162
129
516
282
0
0
0
0
291aang,droutr,
1.040
a
29.12
39.42
13
2
366
498
0
0
0
0
11
11DO
0.390
a
10.92
10.34
20
20
223
211
0
0
0
0
W
1344=
0.143
s
4.00
2.19
284
277
1107
605
146
146
- 584
319
�G
2glaarg,droutr,
1.040
s
29.12
21.68
7
7
202
150
0
0
0
0
0.143
w
4.00
219
284
192
767
419
105
73
291
159
Ti13A4=
1Aclom
1270
w
35.56
34.77
41
41
1451
1419
0
0
0
0
lA-hlom
1270
w
3556
61.76
18
3
656
1139
0
0
0
0
1A-htom
1270
w
3556
63.40
33
5
1162
2072
33
5
1162
2072
C
16C-30ml
0.032
-
0.90
128
1306
1306
1170
1672
234
234
210
300
F
22A4pl
0.989
-
27.69
0.00
1306
145
4015
0
234
31
w
0
6
c)AED ex(rsim
3591
997
Envelope loss'gain
13885
13393
3105
3947
12
a) Infiltrafion
2441
w
522
143
b) Roomventilation
0
0
0
0
13
Iramalgaim O(ipan5@ 230
2
460
0
0
Appiimoas/other
1000
0
Subtotal (11n 15ro 13)
16327
15522
3627
39W
Lesexdemal load
0
0
0
0
Lesstansfer
0
0
0
0
Redistribuffm
0
0
0
0
14
Submtal
16327
15522
3627
39W
15
Dud loads
25%
34%
4013
5251
25%
34%
892
1352
Total room load
20W
20M
4518
5342
Airrequired(Qm)
957
967
215
249
Calculations approved bVACCA to meet all reouirements of Manual J 8th Ed
Aid- wr!gNhL t^ 2021-JaM1121321:40
.�9C& —' RigrlSute®Uriwrsa1201919.021 RSU08101 Paget
...1WhgF6oftFNAC\WYNNEBUIDLING-THECOTrAGE.np Calc=M18 FrortDoorfa(s:SW
wrigbWoft• Right-M) Worksheet Job:
Entire House Date:
QUICK CALCS, INC. BY
317 ST LUCIE LANE, FORTPIERCE, FL34946 Plum: 772-466-6799 Emil: QUICKCALCS@AOL.COM
1
Room rame
DEN
SINKAREA
2
Exposdwall
24.0 ft
7.0 it
3
Room height
8.1 ft heaV=l
8.1 It heaNmol
4
Room dimene.am
12.0 x 12.0 ft
60 x 7.0 ft
5
Room area
144.0 fl
42D IF
Ty
Construction
U-value
Or
HTM
Area (
Load
Area
Load
number
(Buh/F-°F)
(BWhMf�
or pedmeter (ft)
(BWh)
or perimeter (m
(Etuh)
Heat
Cool
Gross
N/PJS
Heat
Cool
Gross
NIP/$
Heat
Cool
6
lA/
13A4ccs
0.143
n
4.00
2.19
97
97
389
213
0
0
0
0
I—('
2glaarg,droutr,
1.040
n
29.12
21.68
0
0
0
0
0
0
0
0
13A4ocs
0.143
a
4.00
2.19
0
0
0
0
0
0
0
0
2glaang,droutr,
1.040
a
29.12
39.42
0
0
0
0
0
0
0
0
11
11DO
0,390
a
1092
10.34
0
0
0
0
0
0
0
0
W
13A-4ocs
0.143
s
4.00.
2.19
0
0
0.
0
57
57
227
124
I—C
2glaang,droutr,
1.040
s
29.12
21.68
0
0
0
0
0
0
0
0
13A4c s
0.143
w
4.00
2.19
97
79
315
172
0
0
0
0
lAclom
1270
w
35.56
34.77
0
0
0
0
0
0
0
0
lA-hl=
1270
w
3556
61.76
18
3
656
1139
0
0
0
0
1A-hlom
1270
w
35.56
63,40
0
0
0
0
0
0
0
0
c
16C30ml
0.032
-
0.90
128
144
144
129
184
42
42
38
64
F
22A-tpl
0.989
-
27.69
0.00
144
24
665
0
42
7
194
0
6
c)AED a=um.. n
574
.g
Ern Lope lostgain
2154
2283
459
175
12
a) Infiltration
404
111
118
32
b) Roomwntilation
0
0
0
0
13
Intemal gains: O=pants@ 230
0
0
0
0
A.pplianoedotrer
0
0
Subtotal(Itnes6to 13)
2558
2394
576
207
s Leexlemalload
0
0
0
0
Leastanster
0
0
0
0
Redistribution
0
0
0
0
14
Sublmal
2558
2394
575
207
15
Ductloads
25%
34%
629
811
25%
34%
142
70
Total room load
3187
32A5
718
278
Air required (dm)
152
149
34
13
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
'*- wrlglsL�o'7Y' 2021-Jarf121321:40
A RigitSute® IhiWM1201919.021 RSU08101 Page 2
...1Wdg%DftHVAaWYNNEBUIDLING-THECOT'rAGE.rLp Calc=M18 FrortDoorlaces SW
wrighftoft` RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phone: 772-466-6799 EmaiI:QUICKCALCS@jAOL.COM
i
Room name
CLOSET
GREAT ROOM
2
End wall
0 ft
32.0 It
3
Room height
8.1 it heatfcool
8.1 ft heakool
4
Room dimena m
9.0 x 7A It
1.0 x 452.0 R
5
Room area
63.0 T
452.0 iF
Ty
Construction
U-value
Or
HTM
Area
Load
Area (fe)
Load
number
(BWhdMF)
(BWhAF)
or perimeter (ft)
(BNh)
or pedmeter (ft)
(BWh)
Heat
Cool
Gros
NtPS
Heat
Cool
Gras
NiP/S
Heat
Cool
6
vy
13A-4=
0.143
n
4.00
2.19
0
0
0
0
178
160
640
3W
�G
2glazing, crotN,
1.040
n
29.12
21.68
0
0
0
0
18
0
537
400
13A4=
0.143
a
4.00
2.19
0
0
0
0
0
0
0
0
2glanng,droutr,
1.040
a
29.12
39.42
0
0
0
0
0
0
0
0
11
11DO
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
vr/
13A4=
0.143
s
4.00
2.19
0
0
0
0
0
0
0
0
—G
2glazing, droutr,
1A40
s
29.12
21.68
0
0
0
0
0
0
0
0
13A-4=
0.143
w
4A0
2.19
0
0
0
0
81
40
161
88
1Actom
1270
w
3556
3477
0
0
0
0
41
41
1451
1419
1A-hlom
1270
w
35.56
61.76
0
0
0
0
0
0
0
0
1A-h1om
1270
w
35.56
63.40
0
0
0
0
0
0
0
0
c
16C30ml
0.032
-
0.90
128
63
63
56
81
452
452
405
579
F
22A-tpl
0.989
-
27.69
0.00
63
0
0
0
452
32
886
0
6
c)AEDexamacn
_1
2069
Envelope losugain
56
80
4080
4903
12
a) Infiltration
0
0
539
148
b) Room ventilation
0
0
0
0
13
Intemalgaim O=pants@ 230
0
0
2
460
Applianoesbther
0
0
Subbtal(fnes6lo13)
56
80
4619
5511
Lesexdemalload
0
0
0
0
Lesstian4er
0
0
0
0
Redistribution
0
0
0
0
14
Sublotal
56
80
4619
5511
15
Duo:loads
25%
34%
14
27
25%
34%
1135
1868
Total loomload
ta.'quired
70
1p7
5754
7379
A (Cm)
3
5
274
343
Calculabons approved bvACCAto meet all requirements of Manual J 8th Ed
E 'M- 2021-Jarv121321:40
A 9911Sut&Uriversal 201919.021 RSU08101 Page
...1WdgftsoftWVAQWYNNEBUIDLING-THECOTTAGE.np CeIc=NJB FmrtCaorfaoss:SW
r wrghtsar Right-J® Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
3175T. LUCIE LANE, FORT PIERCE, FL34946 Phone 772-466-6799 Email: QUICKCALCS AOL.COM
1
Room name
MASTFRBATH
POWDER
5.0 ft
Oft
3
Room height
8.1 it heaVowl
8.1 ft heatf000l
4
Room dimerdow
10.0 x 5.0 2
5A x 5.0 ft
5
Roomaree
50.0 fF
25.0 fF
Ty
Construction
U-value
Or
HTM
Area
Load
Area
number
(aWhl[VF
(BWW)
or perimeter (ft)
(BWh)
or perimeeter (ft)
(BWh)
Heat
Cool
Gross
N/P/8
Heat
Cool
Grow
NIPS
Heat
Cool
6
VL—C
13A-4or_s
0.143
n
4.00
2.19
0 0
0 0
0
0 0
0
2glaarg,droutr,
1.040
n
29.12
21.fi8
0 0
0
0
0
0 0
0
`IM—G
13A-0os
0.143
a
4A0
2.19
0 0
0
0
0
0
0
0
2glazing, droutr,
1.040
a
29.12
39.42
0 0
0
0
0
0
0
0
11
`D
11DO
0.390
a
10.92
10.34
0
0
0
0
0
0
0
0
Vr/
13A-0as
0.143
s
4.00
2.19
41
34
134
73
0
0
0
0
�G
2glazing, droutr,
1D40
s
29.12
21.68
7
7
202
150
0
0
0
0
13AAs
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
1Ac1om
1270
w
3556
34.77
0
0
0
0
0
0
0
0
1A-h1om
1270
w
3556
61.76
0
0
0
0
0
0
0
0
1A-htom
1270
w
35.56
63.40
0
0
0
0
0
0
0
0
C
16C30ml
0.032
-
0.90
128
50
50
45
64
25
25
22
32
F
22A-tpl
0.989
-
27.69
0.00
50
5
138
0
25
0
0
0
6
c)AaDexwrsion
y
0
Envelope low(gain
520
284
22
32
12
a) Infiltration
84
23
0
0
b) Roomsentlaton
0
0
0
0
13
Intemalgains: O=pants@ 230
0
0
0
0
Appliancesbither
0
0
Subtotal(lines6b13)
604
307
22
32
Lewexemalload
0
0
0
0
I-Miansfer
0
0
0
0
Redistibuton
0
0
0
0
14
Subtotal
604
307
22
32
15
Dudloads
25%
34%1
148
104
25%
34%
6
11
Total room load
752
411
28
42
Airlequired(dm)
36
19
1
2
Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed
' ' wrtgh1CS01't' 2021-Jan-121321:40
cA RigttSUte® Utiwrwl 201919.021 RSU08101 Page
...\WdghsDt HVAQWYNNESUIDLINGTHECOTTAGE.rup Calc=MI8 FrortDoorfaces SW
wrightsoft° RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772-466-6799 Email OUICKCALCS AOL.COM
1
Room name
KrrCHEN
LAUNDRY
2
Bposadmil
38.0 ft
0 It
3
Room height
8.1 It heaV000l
8.1 ft heatkool
4
Roam dimenaom
1.0 x 232.0 ft
4A x 10.0 It
5
Room area
232.0 IR
40.0 IF
Ty
Consturbon
U-value
Or
HTM
Area
Load
number
(BNhMF-°F)
(Bluhfin
or perimeter (8)
(Btuh)
oorperimeter (it)
(BWh)
Heat
Cool
Gross
NIPSS
Heat
Cool
Gross
NIPS
Heat
Cool
6
13A4ocs
0.143
n
4.00
2.19
138
138
551
301
0
0 0
0
2glaang,droutr,
1.040
n
29.12
21.68
0 0
0
0
0
0
0
0
13A-4ors
0.143
a
4.00
2.19
130
97
387
211
0
0
0
0
2glaarg,droutr,
1.040
a
29.12
39.42
13
2
368
498
0
0
0
0
11
11DO
0.390
a
1022
10.34
20
20
223
211
0
0
0
0
Yp
13A-0ors
0.143
s
4.00
2.19
41
41
162
89
0
0
0
0
_C
2glaang,droutr,
1.040
s
29.12
21.68
0
0
0
0
0
0
0
0
13AAors
0.143
w
4.00
2.19
0
0
0
0
0
0
0
0
1Ac1om
1270
w
3556
34.77
0
0
0
0
0
0
0
0
1A-h1om
1270
w
3556
61.76
0
0
0
0
0
0
0
0
lXhiom
1270
w
3556
63.40
0
0
0
0
0
0
0
0
C
16C30ml
0=
-
0.90
128
232
232
208
297
40
40
36
51
F
22A-tpI
0.989
-
27.69
0.00
232
38
1052
0
40
0
0
0
6
o)AEDexalrsion
37
-1
Enwelope losssain
2951
1570
36
51
12
a) Infiltration
640
175
0
0
b) Roomeentilation
0
0
0
0
13
Intamal gains: Ocwpana@ 230
0
0
0
0
Applianceslother
1000
0
Subtotal(lines6to 13)
3591
2745
36
51
Lessedemalload
0
0
0
0
Lesslydrtsfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
3591
2745
36
51
15
Dud loads
25%
34%
883
931
25%
34%
9
17
Total mom load
1
1
4474
3676
45
68
Air required(Um)
213
171
2
3
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed
c RglJLtAl.021 RS2021-JarF121321:40
...\WrigHoftHJACWNNEBUIDLING-THECOTGE,nq) Calc=NFmftDoorfaws:SW Page
wrighUoW Right-M) Worksheet Job:
Entire House Dfit
QUICK CALCS, INC. By.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 712-466-6799 Emall:QUICKCALC8@AOL.COM
1
Room name
STORAGE
2
EVosadvall
8.0 It
3
Room height
8.1 ft heaV000l
4
5
Room dimensons
Room area
4.0 x 6.0 It
24.0 IF
Ty
Construction
number
U-lalue
(BUhJfe_.F)
Or
HTM
(B1uh4F)
Area (M
or perimeter (ft)
Load
(BUh)
Area
or perimeter
Load
Heat
Cool
Gross
NrP/S
Heat
Cool
Gras
NIPS
Heat
Cool
6
W
L—G
13A-4ocs
2glazing, droutr,
13A-4 r
0.143
1.040
0.143
n
n
a
4.00
29.12
4.00
2.19
21.68
219
32
0
32
32
0
32
130
0
130
71
0
71
11
2glazing, or out',
11DO
1.040
0.390
a
a
29.12
10.92
39.42
10.34
0
0
0
0
0
0
0
0
N/
t—G
13AAo s
0.143
s
4.00
2.19
0
0
0
0
2glaang,drouir,
1344as
1.040
0.143
a
w
29.12
4.00
21.68
2.19
0
0
0
0
0
0
0
0
u�1
F�
1Acloin
to-hlom
1270
1270
w
w
3556
3556
34.77
61.76
0
0
0
0
0
0
0
0
L.GC,
C
1A-hlom
16C30m1
1270
OA32
w
-
3556
0.90
63.40
128
0
24
0
24
0
22
0
31
F
22A-Qtl
0.989
-
27.69
0.00
24
8
222
0
6
c)AED e=rsion
3
Envelope loWgain
502
170
12
a) Infiltration
135
37
b) Room ventilation
0
0
13
Intemalgaim O=pants@ 230
0
0
Applianceabther
0
Subtotal (linesft 13)
637
207
Lessext:malload
0
0
14
Lesstransier
Redistibufion
Subtoml
0
0
637
0
0
207
15
Oudloads
25%
295%
167
60
ToW room load
794
266
Air required (dim)
38
12
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
A&-Ri} ;w Oft��, Vt- 2021-Jan-12132140
A MgdSdteOUri ersa1201919.021 R.SU08101 Page 6
...\Wdg%otHVAQWYNNEBUIDLING-THECOTTAGE.np Calc=M18 Frod Doorfacex SW
- wrightsoft® Duct System Summary o:
Entire House BY
QUICK CALCS, INC.
317 ST. LUCIE LANE, FORT PIERCE, FL34946 Pk*m: 772-46"799 Em iI:QUICKCALCS@AOL.COM
Project Information
For. WYNNE BUILDING CORP.
THE COTTAGE, FT. PIERCE, FL
Extemal static pressure
Pressure losses
Available static pressure
Supply/ return available pressure
Lowest fiction rate
Actual airflow
Total efective length (TEL)
Heating
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.080
in/100ft
967
cfm
126
Supply Branch Detail Table
Cooling
0.50
in H2O
0.28
in H2O
0.22
in H2O
0.110/0.110
in H2O
0.080
in/100ft
967
cfrn
Name
Design
(Btuh)
H(q
(Cfm)
Clg
(dim)
Design
FIR
Diann
(in)
H x W
(in)
Dud
Mall
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
CLOSET
c 107
3
5
0.080
4.0
OxO
VIFx
24.6
90.0
St1
DEN
h 3187
152
149
0.080
7.0
Ox0
VIFx
33.5
90.0
st1
GREAT ROOM
c 3689
137
172
0.080
8.0
OxO
VIFx
14.6
70.0
GREATROOM-A
C 3689
137
172
0.080
8.0
OxO
VIFx
16.1
70.0
KRCI-EN
h 4474
213
171
0.080
7.0
Ox0
VIFx
4.5
70.0
LAUNDRY
C 68
2
3
0.080
4.0
Ox0
VIFx
5A
70.0
MASTERBATH
h 752
36
19
0.080
4.0
OxO
VIFx
32.9
90.0
st1
MASTERSEDROOM
c 2671
107
124
0.080
7.0
OxO
VIFx
27.9
90.0
st1
MASTER BEDROOM -A
c 2671
107
124
0.080
7.0
Ox0
VIFx
35.9
90.0
st1
POWDER
C 42
1
2
0.080
4.0
OxO
VIFx
29.2
90.0
st1
SINKAREA
h 718
34
13
0.080
4.0
Ox0
VIFx
30.9
90.0
st1
STORAGE
h 794 1
38
12
0.080
4.0
Ox0
VIFx
112
70.0
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(cim)
Clg
(Clm)
Design
FR
Veloc
(ipm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st1
PeakAVF
441
437
0,080
561
12.0
0 x 0
VinIFIX
Wrightsoft- 2021 Jan121321.41
RigitSuteOUrivema1201919.021 RSU08101
Page 1
ACCk ...\W6gt6oR HVACIWYNNE BUIDLING-THE QQTTAGE.np Caic=MI6 Frort Doorfaces SW
Return Branch Detail Table
Name
Grille
Size(in)
Htg
(dm)
Clg
(dm)
TEL
(ft)
Design
FR
Ueloc
(ipm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Dud
MA
Trunk
rbl
Ox0
967
967
0
0
0
0
Ox 0
VIFx
- wrightsoft' 202Warv121321:41
^� •W.u-+.a—.v Pi9kSute0Urive=I 201919.021 RSU08101 Paget
04CCA ...\Wdg%oft WACiWYNNEBUIDLING-THECOTrAGE.np Calc=RIB FrortDoorface SW