Loading...
HomeMy WebLinkAboutAPPROVED, ENERGY CALCS & MANUAL J - 20 FLORES DEL NORTEFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BU€DLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST_ LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. WYNNE BUILDING CORP. Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) 1. New construction or existing New (From Plans) 10. Wall Types(1718.3 sqft.) Insulation Area 2. Single family or multiple family Detached a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 1 d. NIA R= ft2 5. Is this a worst case? Yes 11. Ceiling Types(1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ft2 6. Conditioned floor area above grade (ft2) 1306 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(128.9 sqft.) Description Area 12_ Ducts, location & insulation level R ft2 a. U-Factor: 591, U=1.02 76.04 ft2 a. a. Sup: Attic, Ret: Attic, AH: Attic 6 120 5h1GG: 5€10G=0.29 b. b. U-Factor: Sol, U=1.03 40.00 ft2 C. SHGC: SHGC=0.27 13. Cooling Systems kBtu/hr Efficiency c. U-Factor: Sgl, U=1.02 12.85 ft2 a. Central Unit 29.0 SEER:14.00 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: 4.701 ft Area Weighted Average SHGC: 0.281 14. Heating Systems kBtulhr Efficiency 8. Skylights Description Area a. Electric Heat Pump 27.0 HSPF:8.20 U-Factor.(AVG) NIA NIA ft2 SHGC(AVG): NIA 9. Floor Types Insulation Area 15. Hot Water Systems a. Slab -On -Grade Edge Insulation R= 0.0 2 1306.00 ft2 a. ElectricTankless Cap: 1 gallons EF: 0.600 c. N/A R= ft2 b. Conservation features None 16. Credits None Glass/Floor Area: 0.099 Total Proposed Modified Loads: 41.30 Total Baseline Loads: 43.21 PASS I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this�� Code. calculation indicates compliance®gyp ' with the Florida Energy Code.�- PREPARED BY. Before construction is completed Rill (3'7'2021 this building will be inspected for aG ._:..__ _. t3 0 �' DATE: compliance with Section 553.908 Florida Statutes. ' hereby certify that this building, as designed, is ' compliance �OAWE with the Florida Energy Ce�3er� OWNER/A E T: BUILDING OFFICIAL: DATE: N,l DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance with a proposed duct leakage On requires a PERFORMANCE Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNETIICC 380, is not greater than 0.000 On for whole house. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a PERFORMANCE envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2). 6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE COTTAGE IMPACT Addresstype: Street Address Building Type: User Bedrooms: 1 Lot#: - Owner: WYNNE BUILDING CORP. Conditioned Area: 1306 Block/SubDivision: - TotalStories: 1 PlatBook: Builder Name: WYNNE BUILDING CORP. Worst Case: Yes Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY Rotate Angle: 180 County: St. Lucie Jurisdiction: Cross Ventilation: No City, State, Zip: FT. PIERCE, FamilyType: Detached Whole House Fan: No FL, New/Existing: New (From Plans) Terrain: Suburban YearConstruct: Shielding: Suburban Comment: CLIMATE Design Design Temp Int Design Temp Heating Design Dailytemp Location Tmy Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNICIPA 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 13M76.2001953125 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Finished Cooled Heated _ 1 MASTER BEDROOM 234 1895.4 No 0 1 Yes Yes Yes _2 DEN 144 1166.4 No 0 Yes Yes Yes _3 SINK AREA 42 340.2 No 0 Yes Yes Yes _4 CLOSET 63 510.3 No 0 No Yes Yes _ 5 GREAT ROOM 452 3661.2 No 2 Yes Yes Yes _ 6 MASTER BATH 50 405 No 0 Yes Yes Yes _7 POWDER 25 202.5 No 0 No Yes Yes _8 KITCHEN 232 1879.2 Yes 0 Yes Yes Yes _9 LAUNDRY 40 324 No 0 No Yes Yes _10 STORAGE 24 192 No 0 0 Yes Yes Yes FLOORS (Total Exposed Area = 1306 sq.ft.) # Floor Type Space Exposed Perim Perimeter R-Value Area U-Factor Joist R-Value Tile Wood Carpet _ 1 Slab -On -Grade Edge Ins MASTER BEDROOM 31 0 234 ft 0.473 - 0.00 1.00 0.00 _2 Slab -On -Grade Edge Ins DEN 24 0 144ft 0.473 - 0.00 1.00 0.00 _3 Slab -On -Grade Edge Ins SINKAREA 7 0 42ft 0.473 - 0.00 1.00 0.00 _4 Slab -On -Grade Edge Ins CLOSET 1 0 63ft 0.473 - 0.00 1.00 0.00 _ 5 Slab -On -Grade Edge Ins GREAT ROOM 32 0 452 ft 0.473 - 0.00 1.00 0.00 _ 6 Slab -On -Grade Edge Ins MASTER BATH 5 0 50 ft 0.473 - 0.00 1.00 0.00 _7 Slab -On -Grade Edge Ins POWDER 1 0 25ft 0.473 - 0.00 1.00 0.00 _ 8 Slab -On -Grade Edge Ins KITCHEN 38 0 232 ft 0.473 - 0.00 1.00 0.00 _ 9 Slab -On -Grade Edge Ins LAUNDRY 1 0 40 ft 0.473 - 0.00 1.00 0.00 10 Slab -On -Grade Edge Ins STORAGE 21 0 24ft 0.304 - 0.00 0.00 1.00 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1306 fe N N CEILING (Total Exposed Area = 1336 sq.ft.) # Ceiling Type Space R-Value Ins.Type Area U-Factor Framing Frac. Truss Type 1 UnderAttio(Vented) MASTER BEDROOM 30.0 Blown 234.0ft2 0.053 0.10 Wood _2 UnderAtic(Vented) DEN 30.0 Blown 144.0ft2 0.053 0.10 Wood _3 UnderAttic(Vented) SINK AREA 30.0 Blown 42.Oft2 0.053 0.10 Wood _4 UnderAttic(Vented) CLOSET 30.0 Blown 63.0ft 0.053 0.10 Wood _5 UnderAttio(Vented) GREAT ROOM 30.0 Blown 452.Oft2 0.063 0.10 Wood _6 UnderAttic(Vented) MASTER BATH 30.0 Blown 50.0ft2 0.053 0.10 Wood _7 UnderAftic(Vented) POWDER 30.0 Blown 25.Oft2 0.053 0.10 Wood _8 UnderAftic(Vented) KITCHEN 30.0 Blown 232.Oft2 0.053 0.10 Wood _9 UnderAtUc(Vented) LAUNDRY 30.0 Blown 40.0R2 0.053 0.10 Wood _ 10 UnderAttic(Vented) STORAGE 30.0 Blown 24.Oft2 0.030 0.11 Wood 11 Knee Wall(Vented) GREAT ROOM 19.0 Blown 30.0ft2 0.045 0.11 Wood WALLS (Total Exposed Area = 1718 sq.ft.) Note: First wall orientation below is as entered. Actual orientation is modified by the rotate angle (180 degrees) as shown in the "Project" section on page 1. / Adjacent Cavity Width Height Area U- Sheath Fnn. Solar Below �/ # Ornt To Wall Type Space RValue Ft In Ft In sq.ft. Factor R-Value Frac. Absor. Grade 1 S=>N Exterior Conc. Bik- Int Ins MASTER BEDROOM 4.1 18.0 0 8.0 1 145.5 0.149 0 0 0.30 0% _2 W=>E Exterior Conc. Bilk - Int Ins MASTER BEDROOM 4.1 13.0 0 8.0 1 105.1 0.149 0 0 0.30 0% 3 N=>S Exterior Conc. Bilk - Int Ins DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _4 W=>E Exterior Conc. Bik- Intlns DEN 4.1 12.0 0 8.0 1 97.0 0.149 0 0 0.30 0% _5 S=>N Exterior Conc. Blk- Intlns SINKAREA 4.1 7.0 0 8.0 1 56.6 0.149 0 0 0.30 0% 6 N=>S Exterior Conc. Bik - Int Ins GREAT ROOM 4.1 22.0 0 8.0 1 177.8 0.149 0 0 0.30 0% _7 W=>E Exterior Conc. Bik- Intlns GREAT ROOM 4.1 10.0 0 8.0 1 80.8 0.149 0 0 0.30 0% 6 S=>N Exterior Conc. Bik- Int Ins MASTER BATH 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _9 N=>S Exterior Conc.Bik- Intlns KITCHEN 4.1 17.0 0 8.0 1 137.4 0.149 0 0 0.30 0% _ 10 E=>W Exterior Conc. Bik- Int Ins KITCHEN 4.1 16.0 0 8.0 1 129.3 0.149 0 0 0.30 0% _11 S=>N Exterior Conc. Bik- Intlns KITCHEN 4.1 5.0 0 8.0 1 40.4 0.149 0 0 0.30 0% _12 N=>S Exterior Conc. Bik-Intlns KITCHEN 4.1 35.0 0 8.0 1 282.9 0.149 0 0 0.30 0% _ 13 N=>S Exterior Conc. BIk- Int Ins STORAGE 4.1 6.0 0 8.0 0 48.0 0.149 0 0 0.30 0% _ 14 NHS Exterior Conc. Bilk - Int Ins STORAGE 4.1 5.0 0 8.0 0 40.0 0.149 0 0 0.30 0% _ 15 N=>S Garage Frame - Wood MASTER BEDROOM 11.0 30.0 0 8.0 0 240.0 0.092 0 0.23 0.30 0% DOORS (Total Exposed Area = 20 sq.ft.) Width Height # Omt Adjacent To Door Type Space Storms U-Value Ft In Ft In Area 1 E=>W Insulated KITCHEN None 0.32 3.00 0 6.00 8 20.OR2 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 FORM R4O5-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS (Total Exposed Area = 129 sq.ft.) / Wall -Overhang- / # Omt ID Frame Panes NFRC U-Factor SHGC Imp Storm Area Depth Separation InteriorShade Screening -1 W=>E 2 Metal Low-E Single Yes 1.02 0.29 N N 32.412 1.0 ft 5 in 1.0 It 5 in None None _ 2 W=>E 4 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft2 1.0 It 5 in 1.0 ft 5 in None None - 3 N=>S 6 Metal Low-E Single Yes 1.02 0.29 N N 18.4ft 1.0 ft 5 in 1.0 ft 5 in None None _4 W=>E 7 Metal Low-E Single Yes 1.03 0.27 N N 40.0R2 12.0 ft0 in 1.0 ft5 in None None _5 S=>N 8 Metal Low-E Single Yes 1.02 029 N N 6.W 1.0 It in 1.O It in None None _ 6 E=>W 10 Metal Low-E Single Yes 1.02 0.26 N N 12.8ft1.0 It 5 in 1.0 ft 5 in None None INFILTRATION # Scope Method SLA CFM50 ELA EgLA ACH ACH50 Space(s) 1 Wholehouse Proposed ACH(50) 0.00026 881 48.35 90.78 0.0907 5.0 All GARAGE # Floor Area Roof Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 ft' 280 W 35 ft 8 it 11 MASS # Mass Type Area Thickness FumitureFraction Space _ 1 Default(8lbs/sq.fL) 0 ft2 Oft 0.30 MASTER BEDROOM _ 2 Default(8lbs/sq.fL) 0 ft2 Oft 0.30 DEN _ 3 Default(8lbs/sq.ft.) 0 ft' Oft 0.30 SINK AREA _4 Default(albs/sq.ft.) 0ft' 0ft 0.30 CLOSET -5 Default(8 lbs/sq.ft.) 0 ft. Oft 0.30 GREAT ROOM _6 Default(81bs/sq.ft.) 0 ft' Oft 0.30 MASTER BATH _7 Default(8lbs/sq.ft.) 0 ft2 Oft 0.30 POWDER -8 Default(8lbs/sq.fL) 0 ft2 Oft 0.30 KITCHEN _ 9 Default(8 lbs/sq.ft.) 0 ft2 Oft 0.30 LAUNDRY -10 Default(8lbs/sq.ft.) 0 ft' Oft 0.30 STORAGE HEATING SYSTEM # System Type Subtype/Speed AHRI# Efficiency Capacity --GeotherrnalHeatPump- Ducts Block kBtu/hr Entry Power Volt Current 1 Electric Heat Pump Split/Single HSPF: 8.20 27.0 0.00 0.00 0.00 sys#1 1 COOLING SYSTEM # System Type Subtype/Speed AHRI # Efficiency Capacity Air Flow SHR Duct Block kBtu/hr cfm -1 Central Unit SplittSingle SEER:14.0 29.0 0 0.80 sys#1 1 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 FORMR405-2020 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type Subtype Location EF(UEF) Cap Use SetPnt Fixture Flow Pipe Ins. Pipe length _ 1 Electric Tankless Garage 0.60 (0.60) 1.00 gal 61 gal 120 deg Standard None 82 Recirculation Recirc Control Loop Branch Pump DWHR Facilities Equal DWHR OtherCredits System Type length length power Connected Flow Eff 1 No NA NA NA No NA NA NA None DUCTS —Supply—--Return— Air CFM 25 CFM 25 HVAC # VDuct # Location R-Value Area Location R-Value Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6.0 120 fF Attic 6.0 45 ft' Default Leakage Attic (Default) (Default) TEMPERATURES Programable Thermostat: N Ceiling Fans: N Cooling [ ] Jan [] Feb [I Mar [I Apr [ ] May [X] Jun [X] Jul Pq Aug [X] Sep [ ] Oct [] Nov Dec [ ] Heating [X] Jan [X] Feb [X] Mar [ ] Apr [ ] May [ j Jun (I Jul [ ] Aug [ ] Sep [ ] Oct [Xj Nov [X] Dec Venting [ ] Jan [] Feb [X] Mar [X] Apr [ ] May [ ] Jun []Jul [ 1 Aug [ 1 �P [XI Oct [X] Nov [ ]Dec Schedule: HERS 2006 Reference Hours VThermostat Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 _Cooling(IND) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _ Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 _ Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 _ Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 6/7/2021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y Owner: WYNNE BUILDING CORP. Jurisdiction: U Design Location: FL, Fort Pierce County: St. Lucie(Florida Climate Zone 2) _ U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeableinsulationshall requirements The exteriorthermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per Knee walls shall be sealed. inch minimum Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alig nment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and anddoom skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation andcantilevered shall be permitted to be in contact with the top side floors) ofsheathing, orcontinuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered Where provided instead of floor insulation, insulation with a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Narrowcavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garageseparation Air sealing shall be provided between the garage and conditionedspaces. Recessedlighting Recessed light fixtures installed in the building thermal Recessed lig ht fixtures installed in the building envelope shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers Exterior walls adjacent to showers and tubs shall onexteriorwall and tubs shall separate them from the showers and tubs. beinsulated. Electrical/phonebox The air barrier shall be installed behind electrical or on exteriorwalls communication boxes orair-sealed boxes shall be installed. HVAC register boo HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or ceiling penetrated by the boot. Concealed When required to be sealed, concealed fire sprinklers shall only sprinklers be sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/7/2021 11:47:00 AM EnergyGaugeO USA 7.0 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area above grade (f:2) Conditioned floor area below grade (W) 7. Windows" Description a. U-Factor: S91, U=1.02 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.03 SHGC: SHGC=0.27 c. U-Factor: SgI, U=1.02 SHGC: SHGC=0.26 Area Weighted Average Overhang Depth: Area Weighted Average SHGC: THE COTTAGE,FT. PIERCE,FL, New (From Plans) Detached 1 1 Yes 1306 0 Area 76.04 fe 40.00 e 8. Skylights Description U-Factor(AVG) N/A SHGC(AVG): N/A 9. Floor Types Insulation a. Slab -On -Grade Edge Insulation R= 0.0 b. N/A R= c. N/A R= 12.85 ftZ 4.701 ft 0.281 Area N/A ft2 Area 1306.00 fe ft2 ftZ 10. Wall Types(1718.3 sqft.) Insulation Area a. Concrete Block - Int Insul, ExteriorR=4.1 1478.30 ft2 b. Frame - Wood, Adjacent R=11.0 240.00 ft2 c. N/A R= ft2 d. N/A R= ftZ 11. Ceiling Types(1336.0 sgft) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 flz b. Knee Wall (Vented) R=19.0 30.00 ftZ c. N/A R= ftZ 12. Ducts, location & insulation level R ftZ a. a. Sup: Attic, Ret Attic, AH: Attic 6 120 b. c. 13. Cooling Systems kBtu/hr Efficiency a. Central Unit 29.0 SEER:14.00 14. Heating Systems kBtu/hr Efficiency a. Electric Heat Pump 27.0 HSPF:8.20 15. Hot Water Systems a. ElectricTankless Cap: 1 gallons EF: 0.600 b. Conservation features None 16. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: �- Date: Address of New Home: THE COTTAGE City/FL Zip: FT. PIERCE,FL, Ao F���S . nk 3s lii, *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6772021 11:47:00 AM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 wrightsoftm Project Summary ata: Entire House By. QUICK CALCS, INC. 317 SL LUCIE LANE, FORT PIERCE, FL34946 Phore: 772-4666799 E=il:QUICKCALCS@AOL.COM Project• • For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Notes: Design Information Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grflb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16327 Bbuh Structure 15522 Btuh Duds 4013 Central vent (0 cfm) 0 Btuh Btuh Duds Central vent (0 cim) 5251 0 Btuh Btuh none e) Humidification 0 Biuh Blower 0 Btuh Piping 0 Btuh Equipment load 20340 Btuh Use manufacturers data n Infiltration Rate/swing multiplier Equipment sensible load 0.95 19734 Btuh Method Simplified Construction quality Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2094 Btuh Ducts 1524 Btuh Central vent (0 cfm) 0 Btuh Heatin AreaEquipment Cooling (none) latent load 3618 Btuh Molum) e(fV) 10579 10579 Airchanges/hour 0.45 023 Equipment Total Load (Sen+Lat) 23352 Btuh Equiv. ANF (cfm) 79 41 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO3000GOA0 Cond CH14NBO3000GOA0 AHRI ref 9162387 Coil FX4DNBO43L AHRI ref 9162387 Efficiency 8.2 HSPF Efficiency 11.5 EER,14 SEER Heating input Sensible Cooling 20300 Btuh Heating output 28000 Btuh@470F Latentcooling 8700 Btuh Temperature rise 26 OF Total cooling 29000 Biuh Actual airflow 967 ctin Actual airflow 967 chm Airflowfactor 0.048 dm/Btuh Airflowfactor 0.047 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point = 34 OF Backup: Input = 5 kW, Output=18005 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrightsaft- 2021-Jan121321:40 � j�. �..,.... RigIlSute�J Uriversal 201919.021 RSU08101 Page 1 /^^-�^...\WrigF6oftHJAC\WVNNEBUIDLING-THECOTTAGE.np Calc=MJB FrorlDoorfaces:SW wdghtsoW RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. BY 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772466-6799 Email: Ol11CKCALCS@AOL.COM 1 Room name EntireHouse MASTER BEDROOM 2 Elposedwell 145.0 It 31.0 It 3 Room height 8.1 It 8.1 It heat(=] 4 Room dimensons 130 x 18.0 ft 5 .Room area 1306.0 ff 2340 IF Ty Cons7rudon U-value Or HTM Area (n Load number (BWh4F2F) (BWhMt� or perimeter (ft) (BWh) or perimeter (ft) (Btuh) Heat Cool Gross WPIS Heat Cool Gross NIPS Heat Cool 6 1q/ 13A4o 0.143 n 4.00 2.19 446 427 1710 934 0 0 0 0 �G 29laang,droutr, 1.040 n 29.12 21.68 18 0 537 400 0 0 0 - 0 13A4o s 0.143 a 4.00 2.19 162 129 516 282 0 0 0 0 291aang,droutr, 1.040 a 29.12 39.42 13 2 366 498 0 0 0 0 11 11DO 0.390 a 10.92 10.34 20 20 223 211 0 0 0 0 W 1344= 0.143 s 4.00 2.19 284 277 1107 605 146 146 - 584 319 �G 2glaarg,droutr, 1.040 s 29.12 21.68 7 7 202 150 0 0 0 0 0.143 w 4.00 219 284 192 767 419 105 73 291 159 Ti13A4= 1Aclom 1270 w 35.56 34.77 41 41 1451 1419 0 0 0 0 lA-hlom 1270 w 3556 61.76 18 3 656 1139 0 0 0 0 1A-htom 1270 w 3556 63.40 33 5 1162 2072 33 5 1162 2072 C 16C-30ml 0.032 - 0.90 128 1306 1306 1170 1672 234 234 210 300 F 22A4pl 0.989 - 27.69 0.00 1306 145 4015 0 234 31 w 0 6 c)AED ex(rsim 3591 997 Envelope loss'gain 13885 13393 3105 3947 12 a) Infiltrafion 2441 w 522 143 b) Roomventilation 0 0 0 0 13 Iramalgaim O(ipan5@ 230 2 460 0 0 Appiimoas/other 1000 0 Subtotal (11n 15ro 13) 16327 15522 3627 39W Lesexdemal load 0 0 0 0 Lesstansfer 0 0 0 0 Redistribuffm 0 0 0 0 14 Submtal 16327 15522 3627 39W 15 Dud loads 25% 34% 4013 5251 25% 34% 892 1352 Total room load 20W 20M 4518 5342 Airrequired(Qm) 957 967 215 249 Calculations approved bVACCA to meet all reouirements of Manual J 8th Ed Aid- wr!gNhL t^ 2021-JaM1121321:40 .�9C& —' RigrlSute®Uriwrsa1201919.021 RSU08101 Paget ...1WhgF6oftFNAC\WYNNEBUIDLING-THECOTrAGE.np Calc=M18 FrortDoorfa(s:SW wrigbWoft• Right-M) Worksheet Job: Entire House Date: QUICK CALCS, INC. BY 317 ST LUCIE LANE, FORTPIERCE, FL34946 Plum: 772-466-6799 Emil: QUICKCALCS@AOL.COM 1 Room rame DEN SINKAREA 2 Exposdwall 24.0 ft 7.0 it 3 Room height 8.1 ft heaV=l 8.1 It heaNmol 4 Room dimene.am 12.0 x 12.0 ft 60 x 7.0 ft 5 Room area 144.0 fl 42D IF Ty Construction U-value Or HTM Area ( Load Area Load number (Buh/F-°F) (BWhMf� or pedmeter (ft) (BWh) or perimeter (m (Etuh) Heat Cool Gross N/PJS Heat Cool Gross NIP/$ Heat Cool 6 lA/ 13A4ccs 0.143 n 4.00 2.19 97 97 389 213 0 0 0 0 I—(' 2glaarg,droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A4ocs 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2glaang,droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11DO 0,390 a 1092 10.34 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 s 4.00. 2.19 0 0 0. 0 57 57 227 124 I—C 2glaang,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13A4c s 0.143 w 4.00 2.19 97 79 315 172 0 0 0 0 lAclom 1270 w 35.56 34.77 0 0 0 0 0 0 0 0 lA-hl= 1270 w 3556 61.76 18 3 656 1139 0 0 0 0 1A-hlom 1270 w 35.56 63,40 0 0 0 0 0 0 0 0 c 16C30ml 0.032 - 0.90 128 144 144 129 184 42 42 38 64 F 22A-tpl 0.989 - 27.69 0.00 144 24 665 0 42 7 194 0 6 c)AED a=um.. n 574 .g Ern Lope lostgain 2154 2283 459 175 12 a) Infiltration 404 111 118 32 b) Roomwntilation 0 0 0 0 13 Intemal gains: O=pants@ 230 0 0 0 0 A.pplianoedotrer 0 0 Subtotal(Itnes6to 13) 2558 2394 576 207 s Leexlemalload 0 0 0 0 Leastanster 0 0 0 0 Redistribution 0 0 0 0 14 Sublmal 2558 2394 575 207 15 Ductloads 25% 34% 629 811 25% 34% 142 70 Total room load 3187 32A5 718 278 Air required (dm) 152 149 34 13 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. '*- wrlglsL�o'7Y' 2021-Jarf121321:40 A RigitSute® IhiWM1201919.021 RSU08101 Page 2 ...1Wdg%DftHVAaWYNNEBUIDLING-THECOT'rAGE.rLp Calc=M18 FrortDoorlaces SW wrighftoft` RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phone: 772-466-6799 EmaiI:QUICKCALCS@jAOL.COM i Room name CLOSET GREAT ROOM 2 End wall 0 ft 32.0 It 3 Room height 8.1 it heatfcool 8.1 ft heakool 4 Room dimena m 9.0 x 7A It 1.0 x 452.0 R 5 Room area 63.0 T 452.0 iF Ty Construction U-value Or HTM Area Load Area (fe) Load number (BWhdMF) (BWhAF) or perimeter (ft) (BNh) or pedmeter (ft) (BWh) Heat Cool Gros NtPS Heat Cool Gras NiP/S Heat Cool 6 vy 13A-4= 0.143 n 4.00 2.19 0 0 0 0 178 160 640 3W �G 2glazing, crotN, 1.040 n 29.12 21.68 0 0 0 0 18 0 537 400 13A4= 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 2glanng,droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 vr/ 13A4= 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 —G 2glazing, droutr, 1A40 s 29.12 21.68 0 0 0 0 0 0 0 0 13A-4= 0.143 w 4A0 2.19 0 0 0 0 81 40 161 88 1Actom 1270 w 3556 3477 0 0 0 0 41 41 1451 1419 1A-hlom 1270 w 35.56 61.76 0 0 0 0 0 0 0 0 1A-h1om 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 c 16C30ml 0.032 - 0.90 128 63 63 56 81 452 452 405 579 F 22A-tpl 0.989 - 27.69 0.00 63 0 0 0 452 32 886 0 6 c)AEDexamacn _1 2069 Envelope losugain 56 80 4080 4903 12 a) Infiltration 0 0 539 148 b) Room ventilation 0 0 0 0 13 Intemalgaim O=pants@ 230 0 0 2 460 Applianoesbther 0 0 Subbtal(fnes6lo13) 56 80 4619 5511 Lesexdemalload 0 0 0 0 Lesstian4er 0 0 0 0 Redistribution 0 0 0 0 14 Sublotal 56 80 4619 5511 15 Duo:loads 25% 34% 14 27 25% 34% 1135 1868 Total loomload ta.'quired 70 1p7 5754 7379 A (Cm) 3 5 274 343 Calculabons approved bvACCAto meet all requirements of Manual J 8th Ed E 'M- 2021-Jarv121321:40 A 9911Sut&Uriversal 201919.021 RSU08101 Page ...1WdgftsoftWVAQWYNNEBUIDLING-THECOTTAGE.np CeIc=NJB FmrtCaorfaoss:SW r wrghtsar Right-J® Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 3175T. LUCIE LANE, FORT PIERCE, FL34946 Phone 772-466-6799 Email: QUICKCALCS AOL.COM 1 Room name MASTFRBATH POWDER 5.0 ft Oft 3 Room height 8.1 it heaVowl 8.1 ft heatf000l 4 Room dimerdow 10.0 x 5.0 2 5A x 5.0 ft 5 Roomaree 50.0 fF 25.0 fF Ty Construction U-value Or HTM Area Load Area number (aWhl[VF (BWW) or perimeter (ft) (BWh) or perimeeter (ft) (BWh) Heat Cool Gross N/P/8 Heat Cool Grow NIPS Heat Cool 6 VL—C 13A-4or_s 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 2glaarg,droutr, 1.040 n 29.12 21.fi8 0 0 0 0 0 0 0 0 `IM—G 13A-0os 0.143 a 4A0 2.19 0 0 0 0 0 0 0 0 2glazing, droutr, 1.040 a 29.12 39.42 0 0 0 0 0 0 0 0 11 `D 11DO 0.390 a 10.92 10.34 0 0 0 0 0 0 0 0 Vr/ 13A-0as 0.143 s 4.00 2.19 41 34 134 73 0 0 0 0 �G 2glazing, droutr, 1D40 s 29.12 21.68 7 7 202 150 0 0 0 0 13AAs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 34.77 0 0 0 0 0 0 0 0 1A-h1om 1270 w 3556 61.76 0 0 0 0 0 0 0 0 1A-htom 1270 w 35.56 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0.032 - 0.90 128 50 50 45 64 25 25 22 32 F 22A-tpl 0.989 - 27.69 0.00 50 5 138 0 25 0 0 0 6 c)AaDexwrsion y 0 Envelope low(gain 520 284 22 32 12 a) Infiltration 84 23 0 0 b) Roomsentlaton 0 0 0 0 13 Intemalgains: O=pants@ 230 0 0 0 0 Appliancesbither 0 0 Subtotal(lines6b13) 604 307 22 32 Lewexemalload 0 0 0 0 I-Miansfer 0 0 0 0 Redistibuton 0 0 0 0 14 Subtotal 604 307 22 32 15 Dudloads 25% 34%1 148 104 25% 34% 6 11 Total room load 752 411 28 42 Airlequired(dm) 36 19 1 2 Calculations approved bvACCA to meet all reouirements of Manual J 8th Ed ' ' wrtgh1CS01't' 2021-Jan-121321:40 cA RigttSUte® Utiwrwl 201919.021 RSU08101 Page ...\WdghsDt HVAQWYNNESUIDLINGTHECOTTAGE.rup Calc=MI8 FrortDoorfaces SW wrightsoft° RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore: 772-466-6799 Email OUICKCALCS AOL.COM 1 Room name KrrCHEN LAUNDRY 2 Bposadmil 38.0 ft 0 It 3 Room height 8.1 It heaV000l 8.1 ft heatkool 4 Roam dimenaom 1.0 x 232.0 ft 4A x 10.0 It 5 Room area 232.0 IR 40.0 IF Ty Consturbon U-value Or HTM Area Load number (BNhMF-°F) (Bluhfin or perimeter (8) (Btuh) oorperimeter (it) (BWh) Heat Cool Gross NIPSS Heat Cool Gross NIPS Heat Cool 6 13A4ocs 0.143 n 4.00 2.19 138 138 551 301 0 0 0 0 2glaang,droutr, 1.040 n 29.12 21.68 0 0 0 0 0 0 0 0 13A-4ors 0.143 a 4.00 2.19 130 97 387 211 0 0 0 0 2glaarg,droutr, 1.040 a 29.12 39.42 13 2 368 498 0 0 0 0 11 11DO 0.390 a 1022 10.34 20 20 223 211 0 0 0 0 Yp 13A-0ors 0.143 s 4.00 2.19 41 41 162 89 0 0 0 0 _C 2glaang,droutr, 1.040 s 29.12 21.68 0 0 0 0 0 0 0 0 13AAors 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1Ac1om 1270 w 3556 34.77 0 0 0 0 0 0 0 0 1A-h1om 1270 w 3556 61.76 0 0 0 0 0 0 0 0 lXhiom 1270 w 3556 63.40 0 0 0 0 0 0 0 0 C 16C30ml 0= - 0.90 128 232 232 208 297 40 40 36 51 F 22A-tpI 0.989 - 27.69 0.00 232 38 1052 0 40 0 0 0 6 o)AEDexalrsion 37 -1 Enwelope losssain 2951 1570 36 51 12 a) Infiltration 640 175 0 0 b) Roomeentilation 0 0 0 0 13 Intamal gains: Ocwpana@ 230 0 0 0 0 Applianceslother 1000 0 Subtotal(lines6to 13) 3591 2745 36 51 Lessedemalload 0 0 0 0 Lesslydrtsfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3591 2745 36 51 15 Dud loads 25% 34% 883 931 25% 34% 9 17 Total mom load 1 1 4474 3676 45 68 Air required(Um) 213 171 2 3 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed c RglJLtAl.021 RS2021-JarF121321:40 ...\WrigHoftHJACWNNEBUIDLING-THECOTGE,nq) Calc=NFmftDoorfaws:SW Page wrighUoW Right-M) Worksheet Job: Entire House Dfit QUICK CALCS, INC. By. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phone: 712-466-6799 Emall:QUICKCALC8@AOL.COM 1 Room name STORAGE 2 EVosadvall 8.0 It 3 Room height 8.1 ft heaV000l 4 5 Room dimensons Room area 4.0 x 6.0 It 24.0 IF Ty Construction number U-lalue (BUhJfe_.F) Or HTM (B1uh4F) Area (M or perimeter (ft) Load (BUh) Area or perimeter Load Heat Cool Gross NrP/S Heat Cool Gras NIPS Heat Cool 6 W L—G 13A-4ocs 2glazing, droutr, 13A-4 r 0.143 1.040 0.143 n n a 4.00 29.12 4.00 2.19 21.68 219 32 0 32 32 0 32 130 0 130 71 0 71 11 2glazing, or out', 11DO 1.040 0.390 a a 29.12 10.92 39.42 10.34 0 0 0 0 0 0 0 0 N/ t—G 13AAo s 0.143 s 4.00 2.19 0 0 0 0 2glaang,drouir, 1344as 1.040 0.143 a w 29.12 4.00 21.68 2.19 0 0 0 0 0 0 0 0 u�1 F� 1Acloin to-hlom 1270 1270 w w 3556 3556 34.77 61.76 0 0 0 0 0 0 0 0 L.GC, C 1A-hlom 16C30m1 1270 OA32 w - 3556 0.90 63.40 128 0 24 0 24 0 22 0 31 F 22A-Qtl 0.989 - 27.69 0.00 24 8 222 0 6 c)AED e=rsion 3 Envelope loWgain 502 170 12 a) Infiltration 135 37 b) Room ventilation 0 0 13 Intemalgaim O=pants@ 230 0 0 Applianceabther 0 Subtotal (linesft 13) 637 207 Lessext:malload 0 0 14 Lesstransier Redistibufion Subtoml 0 0 637 0 0 207 15 Oudloads 25% 295% 167 60 ToW room load 794 266 Air required (dim) 38 12 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed A&-Ri} ;w Oft��, Vt- 2021-Jan-12132140 A MgdSdteOUri ersa1201919.021 R.SU08101 Page 6 ...\Wdg%otHVAQWYNNEBUIDLING-THECOTTAGE.np Calc=M18 Frod Doorfacex SW - wrightsoft® Duct System Summary o: Entire House BY QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Pk*m: 772-46"799 Em iI:QUICKCALCS@AOL.COM Project Information For. WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest fiction rate Actual airflow Total efective length (TEL) Heating 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 cfm 126 Supply Branch Detail Table Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 cfrn Name Design (Btuh) H(q (Cfm) Clg (dim) Design FIR Diann (in) H x W (in) Dud Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk CLOSET c 107 3 5 0.080 4.0 OxO VIFx 24.6 90.0 St1 DEN h 3187 152 149 0.080 7.0 Ox0 VIFx 33.5 90.0 st1 GREAT ROOM c 3689 137 172 0.080 8.0 OxO VIFx 14.6 70.0 GREATROOM-A C 3689 137 172 0.080 8.0 OxO VIFx 16.1 70.0 KRCI-EN h 4474 213 171 0.080 7.0 Ox0 VIFx 4.5 70.0 LAUNDRY C 68 2 3 0.080 4.0 Ox0 VIFx 5A 70.0 MASTERBATH h 752 36 19 0.080 4.0 OxO VIFx 32.9 90.0 st1 MASTERSEDROOM c 2671 107 124 0.080 7.0 OxO VIFx 27.9 90.0 st1 MASTER BEDROOM -A c 2671 107 124 0.080 7.0 Ox0 VIFx 35.9 90.0 st1 POWDER C 42 1 2 0.080 4.0 OxO VIFx 29.2 90.0 st1 SINKAREA h 718 34 13 0.080 4.0 Ox0 VIFx 30.9 90.0 st1 STORAGE h 794 1 38 12 0.080 4.0 Ox0 VIFx 112 70.0 Supply Trunk Detail Table Name Trunk Type Htg (cim) Clg (Clm) Design FR Veloc (ipm) Diam (in) H x W (in) Duct Material Trunk st1 PeakAVF 441 437 0,080 561 12.0 0 x 0 VinIFIX Wrightsoft- 2021 Jan121321.41 RigitSuteOUrivema1201919.021 RSU08101 Page 1 ACCk ...\W6gt6oR HVACIWYNNE BUIDLING-THE QQTTAGE.np Caic=MI6 Frort Doorfaces SW Return Branch Detail Table Name Grille Size(in) Htg (dm) Clg (dm) TEL (ft) Design FR Ueloc (ipm) Diam (in) H x W (in) Stud/Joist Opening (in) Dud MA Trunk rbl Ox0 967 967 0 0 0 0 Ox 0 VIFx - wrightsoft' 202Warv121321:41 ^� •W.u-+.a—.v Pi9kSute0Urive=I 201919.021 RSU08101 Paget 04CCA ...\Wdg%oft WACiWYNNEBUIDLING-THECOTrAGE.np Calc=RIB FrortDoorface SW