Loading...
HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) 10. Wall Type01432.0 sgft.) insulation Area 2. Single family or multiple family Detached p y a. Concrete Block - int Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft' 3. Number of units, if multiple family 1 c. NIA R= ft2 4. Number of Bedrooms 3 d. NIA R= ft2 11. Ceiling Types (1783.0 sgft.) Insulation Area 5. is this a worst case? Yes a. Under Attic (Vented) R=30.0 1753.00 ft 6. Conditioned floor area above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floor area below grade (ft2) 0 c. N1A R= ft2 12. Ducts R ft2 7. Windows(151.4 s ft.) Description Area q a_ Sup: Attic, Rat: Attic, AH: Attic 6 195 a. U-Factor. Sgl, U=1.02 111.36 ft2 SHGC: SHGC=029 b. U-Factor: Sgl, U=1,11 40.00 ft2 13. Cooling systems kStu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor. NIA ft2 SHGC: Area Weighted Average Overhang Depth: 2,850 ft. 14, Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.285 a. Electric Heat Pump 34.8 HSPF:$.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): N/A a. Electric Cap: 40 gallons 9. F1oorTypes (1753.0 sgft.) Insulation Area EF:0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 €N b. Conservation features b. N/A R= ft2 None C. N/A R= ft2 16. Credits None Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38 PASS Total Baseline Loads: 50.69 I hereby certify that the plans and specifications covered by Review of the plans and O -JOE this calculation are in compliance with the Florida Energy specifications covered by this �s y O*A Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed w ' DATE: 1-12-20 this building will be inspected for compliance with Section 553.908 > I hereby certify that this building, as designed, is in ompliance Florida Statutes. 1, {'0 with the Florida Energy Code. r We OWNER/A BUILDING OFFICIAL: DATE: t DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402AA A and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2). 1112/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O F8C 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST mr-rvn PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot # Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 180 Street: THE W INDSOR Permit Office: ST. LUCIE COUNTY Gross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Detached FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0 224 ft' __ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1ft 0 63 ft` _- 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0 56 ft2 _—_ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft' — 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft` --_ 0 1 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6 FORM R405-2020 IIVru I bUMPRAKT t+11`711:l,f\LIA I K=rvK I FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulatio BEDROOM 2 12 ft 0 180 ft2 -- 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 --_ 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN 11 ft 0 209 ft2 --- 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft2 - — - 0 1 0 10SIab-On-Grade Edge Insulatio HALL t ft 0 25 ft2 --- 0 1 0 11SIab-On-Grade Edge Insulatio FOYER 9 ft 0 92 ft2 -- 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 ft 0 169 ft2 -_- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type _ i Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood _ 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft, 0.1 Wood _ 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood _ 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood _ 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood _ 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood _ 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood _ 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM3 30 Blown 169 ft2 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 0 _ 1 NE=>SW Exterior Concrete Block - Int InsMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.3 0 _ 2 SW=>NE Exterior Concrete Block - Int InsNASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 NW=>SE Exterior Concrete Block - Int InsMASTER SE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6 eneAe PAnr-'>n9n INPIIT SI IMMARY CHECKLIST REPORT WALLS Adjacent cavity Width Height Sheathing Framing Solar Below it T. Space WMI lype -4 NE=>SW Exterior Concrete Block - Int InsMASTER SA 4.1 8 0 8 0 64.0 T 0 0 0.3 0 5 NE=>SW Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.3 0 6 NE=>SW Exterior Concrete Block - Int Ins8EDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 -7 SW=>NE Exterior Concrete Block- Int Ins(DINING/GRE 4A 30 0 8 0 240.0 fV 0 0 0.3 0 -8 NW=>SE Exterior Concrete Block -Int InsfilINING/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.3 0 _9 SW=>NE Exterior Concrete Block- Int lnsulKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.3 0 10 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.3 0 _ 11 SE�NW Exterior Concrete Block - Int Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.3 0 12 SW=>NE Exterior Concrete Block - Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 NE=>SW Exterior Concrete Block- Int InsBEDROOM 3 4.1 13 0 8 0 104.0 fP 0 0 0.3 0 14 SW=>NE Exterior Concrete Block - Int InsGEDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.3 0 15 N=>S Garage Frame - Wood BEDROOM 3 11 26 8 208.0 fP 0.23 0.3 0 DOORS # Omt Door Type Space Storms U-Value I� Area FtWidth In FHeightln 1 SE=>NW Insulated FOYER None .39 3 3 6 8 21.7f2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.02 0.29 Y 32.4 ft' 1 ft 0 in 1 ft 4 in Drapes/blinds Exterior 5 _ 2 NE=>SW 5 Metal Low-E Single Yes 1.02 0.29 Y 6.9 ft% 1 ft 0 in 1 ft 4 in None None _ 3 NE=>SW 6 Metal Low-E Single Yes 1.02 0.29 Y 16.2 ft' 1 ft 0 in 1 ft 4 in None None 4 SW=>NE 7 Metal Low-E Single Yes 1.02 0.29 Y 39.8 ff 1 It 0 in 1 It 4 in None None 5 NW�SE 8 Metal Low-E Single Yes 1.11 0.27 Y 40.0 IF 8 It 0 in t It 4 in None None 6 NE=>SW 13 Metal Low-E Single Yes 1.02 029 Y 16.2 ft' 1 It 0 in 1 ft4 in Dmpes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft' 806 ft= 26 it 8 ft 71 INFILTRATION # Scope Method $LA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12 120.37 .0902 5 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6 =norm Dnnr,_')r%0n IMPI IT RI IMMARY CHFCKI 1ST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Stock Ducts 1 Electric Heat Pump/ Split Sing[ HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Sing] SEER: 15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Can # Company Name System Model # Collector Model # Area Volume FEF None None ft DUCTS / — Supply — — Return — Air CFM 25 CFM25 HVAC # V/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool _ 1 Attic 6 195 ft- Attic 55 ft- Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Coo]in [[ �Jan [[ ]] Feb ((�� Mar Heating [X] Jan [XJ Feb fX1 Mar ] A r E ] Apr r ] May [X� Jun [JC) Jul ] may [ I Jun [ ] Jul AugX� Aug Se 1 Sep Oct Nov Oct Nov f[X1] Dec Dec Venting [[ ]) Jan tt 11 Feb [[�X1] Mar tx) 4 ) [ 1 Jun t 1 Jul III 777 Aug E 7 Sep X j ] Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(B lbs/sq.ft. 0 ft- oft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft' ft 0.3 WIC Default(8 Ibs/sq.ft. ft' ft 0.3 MASTER BATH Default(B lbslsq.ft. W ft 0.3 M. BATH Default(8 lbs/sq.ft. ft' ft 0.3 LAUDRY Default(8 Ibs/sq.ft. ft' ft 0.3 BEDROOM 2 Default(8 lbslsq.ft. w ft 0.3 DINING/GREAT R nofnultra Ibs/so.ft. ft' ft 0.3 KITCHEN 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC An Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. ft' ft 0.3 BATH Default(S lbs/sq.ft. ft' ft 0.3 HALL Default(8 lbs/sq.ft. W ft 0.3 FOYER Default(8 lbsts.ft. ft' ft 0.3 BEDROOM 3 1/122021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE W INDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number. U Owner. Jurisdiction: w x Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceilinglsoffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls Walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors I skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity, insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on Narrow cavities installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa . Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Dinno and wirino Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box o The air barrier shall be installed behind electrical or communication I exterior boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed In a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sorinkleE cover Plates and watts Or ;Wfinc5___ _ I — a. In addition, inspection or log wars snan De in accuruanre win, u is plvrmioua ul -.. - 1/12/2021 1:15 PM ErtergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing Z Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Windows*' Description a. U-Factor: Sgl, U=1.02 SHGC: SHGC=0.29 b. U-Factor. S91, U=1.11 SHGC: SHGC=0.27 c. U-Factor. N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Skylights Description a. U-FactogAVG): N/A SHGC(AVG): NIA THE WINDSOR, FT. PIERCE, FL, New (From Plans) 10. Wall Type and Insulation Insulation Area a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft' Detached b. Frame - Wood, Adjacent R=11.0 208.00 ft' 1 c. N/A R= ft- 3 d. N/A R= ft' 11. Ceiling Type and insulation level Insulation Area Yes a. Under Attic (Vented) R=30.0 1753.00 ft2 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 c. N/A R= ft2 Area 12. Ducts, location & insulation level R ft2 111.36Area ft' a. Sup: Attic, Ret: Attic, AM: Attic 6 195 40.00 ft' 13. Cooling systems kStu/hr Efficiency ft2 a. Central Unit 34.8 SEER:15.00 ft2 2.850 ft. 0.285 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft' b. N/A R= ft2 c. N/A R= ft' 14. Heating systems a. Electric Heat Pump 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) 1 certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant fe res. 1 Builder Signature: Date: Address of New Home: \1Z �;I'c-ck City/FL Zip: �� •� Q kBtu/hr Efficiency 34.8 HSPF:8.50 Cap: 40 gallons EF: 0.97 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRss2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 Project SummaryJob: wr�ghtsofk® Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34W Phone; 772-066-6799 Fax 772.466-6796 Email: QUICKCALCS@AOL.rOM Project• • For. WYNNE DEVELOPMENT THE W INDSOR, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db OF Inside db 70 OF Inside db 75 F Design TO 28 OF Design TO 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21542 Btuh Structure 16420 Btuh Duds 6191 Central vent (0 cfm) 0 Btuh Btuh Duds Central vent (0 dm) 9337 0 Btuh Btuh none e) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27734 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 24470 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2495 Btuh Ducts 2546 Btuh Central vent (0 cfm) 0 Btuh Heat' Area Coolingg (none) (fP) 1753 1753 Equipment latent load 5041 Btuh Volume(fF) 16478 16478 Airchanges/hour 0.38 0.20 Equipment Total Load (Sen+Lat) 29511 Btuh Equiv.AVF(dm) 104 55 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIERAIR CONDITIONING Model 25HBC536XO30 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Airflowfactor Static pressure Space thermostat Capacity balance point = 36 OF I.11i 34600 Bluh @ 47-F 27 OF 1160 cfm 0.042 cfrn/Btuh 0 in H2O Backup: Input=7kW, Output= 230G9 Btuh, 100 AFUE Make Carrier Trade CARRIERAIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER,15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cdrn Airflowfactor 0.045 chVBtuh Static pressure 0 in H2O Load sensible heat ratio 0.84 Calculations approved byACCAto meetall requirements of Manual J 8th Ed wrightsoft^ 2021-JaM213:18:18 RigftSute®Unv ml 201919.021 RSU08101 Page 1 ...D'amerts\Wnghwft HVAC1W7NNE-THEWIND50Rnp Calc=M,18 FroNDoorfaces: N wrightsaw Right-M Worksheet o�e: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN.,FT. PIERCE, FL 34946 Ptnre: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 F�osed xall 207.6 It 41.0 ff 3 Room height 9.4 ft d 9.4 ft heaUmcl 4 Room tlimensions 14A x 20.0 ft 5 Room area 1753A iR 280.0 ft Ty Construction U-value Or HTM Area (� Load Area (fl Load number (BWhV-7) (BluhM or perimeter (ft) (BWh) or perimeter (ft) (Bhrh) Heat Cool Gross N/P/S Heat Cool Gros N/P5 Heat Cool 6 13A4= 0.143 n 4.00 2.55 649 596 2386 1517 66 66 263 167 1Adom 1270 n 3556 34.77 15 0 533 522 0 0 0 0 4A5-20m 0.770 n 21-96 1931 38 0 815 730 0 0 0 0 W 13A4= 0.143 re 4.00 255 27 27 106 68 0 0 0 0 11 13A-4ors 0.143 a 4.00 2.55 141 100 400 255 0 0 0 0 I---G 1Ac1am 1270 a 3556 87116 20 1 711 1741 0 0 0 0 I—D 1100 0.390 e 10.92 1131 21 21 229 238 0 0 0 0 W 13A4= 0.143 se 4.00 2.55 27 27 106 68 0 0 0 0 W( - 13Aha¢ 0.143 a 4.00 2S5 536 530 2121 1349 188 188 753 479 I---C 1Aciam 1270 s 35.56 34.77 6 6 213 209 0 0 0- 0 W 13A4acs 0.143 w 4.00 2.55 320 255 1022 649 132 108 432 275 {---G tA4= 1270 w 35.56 54.53 12 1 415 636 12 1 415 636 4L—GG 1A.cl= 1270 w 35.56 54M 12 1 427 654 12 1 427 654 4Arr2om 0.770 w 21.56 45.63 41 2 880 1862 0 0 0 0 P 12C-Dam 0.091 255 128 254 254 647 326 0 0 0 0 C 16A30md 0.032 - 0190 232 1753 1753 1571 4067 280 280 251 650 F 22A-tpl 0.989 - 27.69 OAO 1753 208 5748 0 280 41 1135 0 6 c)AEDeucvrsion 397 488 Envelope low/gain 1 18331 15285 36761 3349 12 a) Infiltration 3211 90 729 205 b) Rccmvennlilation 0 0 0 0 13 Internal gains: Ooarpans@ 230 1 230 0 0 0 Appliarrndother 0 Subtotal(lines6to13) 21542 16420 4405 3554 Lose external load 0 0 0 0 0 0 Les transfer 0 0 0 0 0 0 Redisb)buhon 21542 16420 4405 3554 14 Subtotal 29% 57% 6191 9337 29% 57% 1266 2021 15 Dud loads Total room load 27734 25757 5671 237 W75 251 Air required (dm) 1160 1760 -*- Mel-W~tW fe RigttSuL@lkiversa1201919.021 RSU08101 .. Ooa rtslWng%oftHVAQWYNNE-THEWINDSORnp Calc=W8 Front Doorfaces:N 2021-JaM213:18:18 Page 1 wrighWIDW Right,JO Worksheet Job: Entire House per: QUICK CALCS, INC. By. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fa1c 772-4666796 Email: QUICKCALCS m( AOL.COM 1 Room name WIC MASTER BATH 2 EVOSelwall 0It 90It 3 Room height 9.4 It heaVmol 9.4 It hea*ool 4 Room dimensions 7.0 x 9.0 It 7.0 x 9.0 It 5 Roomarea 630 ff 63.0 IF Ty Consivction U-value Or HTM Area OF) Load number (BWhAF-°F) (8whr) or pen meter (ft) (Bluh) orperimeter(t) (BWh) Heat Cool Gros NIP/. Heat Cool Gros WP/S Heat Cool 6 13A-4ccs 0.143 n 4.00 2.55 0 0 0 0 0 0 0 0 1Ac1cm 1270 n 3556 34.77 0 0 0 - 0 0 0 0 0 4AS2orn 0.770 n 21.56 1931 0 0 0 0 0 0 0 0 w 13A4ocs 0.143 ne 4.00 2-55 0 0 0 0 0 0 0 0 11 13A = 0.143 a 4.00 2.55 0 0 0 0 0 0 0 0 �(' -to-clom 1270 a 3556 87.06 0 0 0 0 0 0 0 0 �D 11D0 0.390 a 1092 11.31 0 0 0 0 0 0 0 0 w 13A4o,s -13A4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 W/ 0.143 s 4.00 255 0 0 0 0 85 85 339 215 �C 1Aclom 1270 s 35s6 34.7 o 0 0 0 0 0 0 0 13A4ots 0.143 w 4.00 255 0 0 0 0 0 0 0 0 1Aclom 1270 w 3556 54M 0 0 0 0 0 0 0 0 tAclom 1270 w 3556 54M 0 0 0 0 0 0 0 0 4A520m 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-Qw 0.091 2.55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 2.32 63 63 56 146 63 63 56 146 F 22A-tpI 0989 - 27.69 0.00 63 0 0 0 63 9 249 0 6 c)AED exarsian -10 1 -28 Envelope loss(gain 56 136 644 334 12 a) Infiltration 0 0 160 45 b) Room ventlaton 0 0 0 0 13 Internal gains: Ooolpants@ 230 0 0 0 0 Applianoes/other 0 0 Subbfal(1ines6to13) 56 136 804 379 Lesextemallozd 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 boa 379 15 Duct loads 29i 57i 16 n zs°o 57^i 231 216 Total mom load 73 214 1036 595 Airrequired(dm) 3 10 43 27 Calculations approved byACCAto meet all requirements of Manual J 8th Ed Pogtt79.021 2021Jan-1213:18:18 Aftk ...DomrtslWrg4oftHUACWYNNE-THEWINDSORntp Calc=hUB FrontDoortaces: N Page 2 t t wrightsoW Right-M Worksheet Da Entire House BY By. QUICK CALCS, INC. c17 RT I I IrJP I N F PIERCE. FL 34946 Phore:772-4666799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM 1 Room name MBATH KrrCHEN 2 EVOWdMIl 8.0ft 8.0ft 3 Room height 9.4 ft heatbDd 9A ft hewoDd 4 Room dimensions 7.0 x 8.0 ft 1.0 x 172.0 It 5 Room area 56.0 fF 172D fP Ty Construction U-value Or HTM Area (" Load Area (ilk Load number (BWhtl-T) (BWh4M or perimeter (ft) (13Wh) or perimeter (ft) (B41h) Heat Cool Grote N/PS Heat Cool Grass NrPS Heat Cool 6 13A-0o¢ 0.143 d 4.00 2-% 0 0 0 0 0 0 0 0 0 0 0 0 1A.clom 1270 n 35M 34.77 0 0 0 0 0 0 0 0 4A5-tom 0.770 n 21-% 1931 0 0 0 0 W 13A-4orss 0.143 ne 440 2.55 0 0 0 0 0 0 0 0 0 0 11 V�/ 13A-4ors 0.143 a 4.00 2S5 0 0 0 0 0 0 0 F—f tActom 1270 a 3556 87A6 0 0 0 0 0 0 -0 0 0 t_.D 11DO 0" a 10.92 1131 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 se 4A0 2.55 0 0 0 0 0 0 t13AAocs 0.143 s 4.00 255 75 69 277 176 0 0 0 0 0 —G to-clom 1270 s 3556 34.77 6 6 213 209 0 0 0. y/ 13A-4ors 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 0 )---G IA -Om 1270 w 3556 5453 0 0 0 0 0 0 0 IL----GG 1Aclom 1270 w 3556 54M 0 0 0 0 0 0 0 0 4AS2om 0.770 w 21M 45.63 0 0 0 0 0 0 0 192 0 96 P 12C-Ow 0.091 - 255 126 0 0 0 0 75 75 C 16A30md 0.032 - 0.90 2.32 56 56 50 130 172 172 154 399 F 22A-Ipl 0.989 - 27.69 0.00 56 8 222 0 172 8 222 0 6 C)AEDexivlson a -34 Envelope lossrgain 762 477 567 462 12 a) Imitation 142 40 0 0 0 0 b) Roomventilation 0 0 13 Infemalgairs: O=pants@ 230 0 0 0 0 0 Appltanoadalver 0 Subtolal(lines6to13) 9w 517 567 462 Lesse>aemal load 0 0 0 0 0 0 Lesstransfer 0 0 0 0 0 0 Redls4ibuton 904 517 567 462 14 Subtotal 29% 57% 260 294 29% 5n. iGi 263 15 Dudloads Total room load 1164 49 811 37 730 31 725 33 Air required(dm) M ►Nsv1't^ A A � RigkTHEWINriSORIW GIII.021 Frcrt1 o ,.Dowrer6lWdgt>5o11tNAgWYNNE-THE WINDSORnq C31c=M18 FroRDoorfaces N 2021Jan1213:18:18 Page 3 1 wrightsW Right-J® Worksheet °�` Dat Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Plore: 772-466-6799 Fax 7724666796 Email: OUICKCALCS@AOL.COM 1 Room name BATH BEDROOM2 2 Eposetlxall 5.0 It 42.6 it 3 Roam height 9.4 it heatbool 9.4 It I'mat(000l 4 Room dimer one 9.0 x 6.0 it 1.0 x 204.0 it 5 Room area 45.0 T 204.0 1F Ty Construction U-value Or HTM Area (fl0 Load Area (ft0 Load number (Btuhd--q (BWhAn or perimeter (it) (Bt1h) or perimeter (ft) (Bluh) Heat Cool Gros NIPS Heat Cool Gros N/PIS Heat Cool 6 %t 13A-4ocs 0.143 n 4.00 2.55 47 47 188 12D 132 132 527 335 to-ctom 1270 n 3556 34.77 0 0 0 0 0 0 0 0 L�---GG 4A5-2om 0.770 n 2155 19.31 0 0 0 0 0 0 0 0 W 13A4ccs 0.143 ne 4.00 255 0 0 0 0 27 27 106 68 11 W 13AAocs 0.143 a 4-DO 255 0 0 0 0 85 65 259 164 �-G 1Aciom 1270 a 3556 87.06 0 0 0 0 20 1 711 1741 L-D 1100 0.390 a M92 11.31 0 0 0 0 0 0 0 0 W 13A-4= 0.143 se 4.00 255 0 0 0 0 27 27 106 68 l�/ 13A4ors 0.143 s 4.00 2.55 0 0 0 0 132 132 527 335 I-C 1Ac1om 1270 s 3556 34.77 0 0 0 0 0 0 0 0 13A4= 0.143 w 4.00 2.55 0 0 0 0 0 0 0 0 1Actom 1270 w 35.56 64.53 0 0 0 0 0 0 0 0 1Ac1cm 1270 w 3556 54.53 0 0 0 0 0 0 0 0 4A5-2om 0.770 w 2156 45.63 0 0 0 0 0 0 0 0 P 12C-ow 0.091 2,55 128 0 0 0 0 0 0 0 0 C 16A30md 0.032 - 0.90 232 45 45 40 104 204 204 183 473 F 22A-tpl 0289 - 27.69 0.00 45 5 138 0 204 43 4179 0 6 c)AEDexcumon 47 -99 Errvelope loss/gain 367 207 1 35991 3085 12 a) Infiltration 89 25 1 758 214 b) Roomvantilafion 0 0 0 0 13 Intemalgaim Oovpants@ 230 0 0 0 0 0 Applianceslotller 0 Subtotal(lirmtib13) 456 232 4357 3299 Les exEmal load 0 0 0 0 0 0 0 0 Lestransfer 0 0 0 0 Redistribution 456 232 4357 32M 14 15 Subtotal Ductloads 29°/ 57°/, 131 132 29% 57% 12521 1876 Total room loatl 587 2s 364 16 5609 235 5175 233 Airrequired(cim) - wr7ghisnl't' .4 A RigkTHEWItlrSOP-rup Ct9.021RSU0810t -.Dodmer6\Wnghlv�ft HUgG1WYNNE-THE WINDSORrw CaIc=MIB FroNDoorfaces:N 2021 %tarF1213:18:18 Page 4 + wrightsoW Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. 8r- 317 ST.. LUCIE LN,Fr.. PIERCE, FL 34W Plum: 772-466-6799 Fax 772-466-6796 Emil: QUICKCALCS@40LCOM 1 Room name ENTRY LAUNDRY 2 3 6yomtivall Room height 18.0 It 9.4 ft heaV000l 13.0 It 9.4 It heaVowl 4 5 Room dimensions Room area 1A x 92D ft 92.0 ff 7.0 x 6.0 It 42.0 iF Ty Corxruction number U-value (BtuhfiF-°F) Or HTM (Blow Area or perimeter (ft) Load (BWh) Area(1F) or perimeter (ft) Load (8tuh) Heat Cool Gross NIPS Heat Cool Grow NIPS Heat Cool 6 11 yl 1344ors 1AtNom 4A5-2om 13A4o s 13A4= 1Ac1an 11DO 1344as 1344a tActan 134-0ors 1Aclorn 1Acicm 4A5-2om 12C-02v 16AmMrnd 22A-y11 0.143 1270 0.770 0.143 0.143 1270 0.390 0.143 0.143 1270 0.143 1270 1270 0.770 OA91 0.032 0.989 n n n ne a a a se s s w w w w - - 4.00 3556 2156 4.00 4A0 35M 1092 4.00 4.00 3556 40 35.56 3556 2156 2.55 0.90 27b9 2.55 34.77 19.31 2.55 2.55 87.06 11.31 2.55 2.55 34.77 255 54.53 54.53 45.63 128 2.32 0.00 0 0 0 0 56 0 21 0 0 0 0 0 0 0 113 92 92 0 0 0 0 35 0 21 0 0 0 0 0 0 0 113 92 18 0 0 0 0 142 0 229 0 0 0 0 0 0 0 287 82 498 0 0 0 0 90 0 238 0 0 0 0 0 0 0 145 213 0 0 0 0 0 0 0 0 0 56 0 0 0 0 0 66 42 42 0 0 0 0 0 0 0 0 56 0 0 0 0 0 66 42 13 0 0 0 0 0 0 0 0 226 0 0 0 0 0 166 38 360 0 0 0. 0 0 0 0 0 144 0 0 0 0 0 84 97 0 II --GC w �C �D W lM _G Vy I-G P C F 6 c)AED excursion 49 -24 Envelopeloss�gain 1239 637 -191 301 12 a) InfiNaton b) Roomsentilation 107 0 30 0 107 0 30 0 13 Internal gains Omupants@ 230 0 0 0 0 Applianceother 0 0 Subtotal (lines 6 to 13) 1346 667 898 331 14 Less exdemal load Lesstransfer Redisbibulion Subtotal 0 0 0 1346 0 0 0 667 0 0 0 898 0 0 0 331 15 Ductloads 29% 570/6 387 379 29% 57% 258 188 Total room load Arregwred(Um) 1733 72 1047 47 1156 48 520 23 Calculations approved bvACCAto meet all read rements of Manual J 8th Ed wrl9htsoTc' 2021-Jan-1213:18:18 Rigt-THEWINDSOsal p Calc.021 RSU081 o Page5 ...DoomeNslWnghLsoftHUAL1WYNNE-THE WINDSORnp CaIc=MJB Front�orfaces:N F wrightsoft° Right-JO Worksheet 'OIX Entire House Date: QUICK CALCS, INC. 317 ST-LUCIE LN, Fr. PIERCE, FL 34946 PIom:772466-6799 Fax 772-4666796 Email: OUICKCALCS@AOL.COM 1 Room name GREATANNN1G Rcom7 2 Exposed wall 500 ft 13.0 ft 3 Room height 9.4 ft heal 9A ft heaftol 4 Room dimensions 1.0 x 557.0 ft 13A x 13D ft 5 Room area 5670 ft' 169.0 IF Ty Construction U-value Or HTM Area Load Am number (SWh49 flF- (eWhfll'`) or penm� (ft) (BWh) or perimeter (It) (BGih) Heat Cool Gros N/Pr5 Heat Cool Gross UPS Heat Cool 6 W 134-0as 0.143 In 4110 2.55 2B2 244 978 622 122 107 429- 273. -IIA-dom 1270 -n 3556 34.77 0 0 0 0 15 0 533 522 4A5-2om 0.770 n 21M 1931 38 0 816 730 0 0 - 0. 0 W 1344ors 0.143 ne 4.00 Z.55 0 0 0 0 0 0 0 0 11 1344ors 0.143 a 4.00 2-95 0 0 0 0 0 0 0 -0 11--DC 1A-dom 1270 a 3556 87.06 0 0 0 0 0 0- 0 0 11DO 03M a 10.9 - 1131 0 0 0 0 0 0 —. 0- - 0 W 13A-4os 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 Iql - 13A-4os 0.143 s 4A0 2.55 0 0 0 0 0 - 0 - ' -0 - 0 L—G 1Ac1arn 1270 s 3556 34.77 0- 0 0 0 0 o < o- - 0 W 13AAo s 0.143 w 4.()0 2.55 188 147 589 375 0 0 0 0 IA-d m 1270 w 3556 6453 0 0 0 0 0 0 0 0 1Actam 1270 w 3556 5453 0 0 0 0 0 0 0 0 ll�--GGG 4A5-2om 0.770 w 2156 45M 41 2 880 1862 0 0 0 0 P 12C )w OD91 - 255 128 0 0 0- 0 - 0 0 0- 0 C 16A-30md OAS - 0.90 232 557 567 508 1315 169 169 151 392 F - 22Ar%S 0289 - 27.69 0.00 -567 - 50 13B5 0 169- 13 - .360 0 6 c)AFD e=rson 307 -100 Envelope loss'9ain 5154 5210 1474 1086 12 a) Nitration 889 251 231 65 b) Roomeentilabon 0 0 0 0 13 Memel gains: O=pants@ 230 0 0 1 230 Appliwoesother 0 0 SubtoIW(l1nes6to13) 6043 5461 1705 1391 Les eximal load 0 0 0 0 Lestander 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 6043 5461 1705 1381 15 Dud loads 29% 57% 1737 3105 29% 57% 490 785 Total room load 7780 85% 2195 2167 Air required (dm) 3251 92 98 Calculations approved bvACCAto meet all reouirements of Manual J 8th Ed !� 2021-Jar-12 13:18:18 '2cw RiE-THE INDSOsa1 p Calc-021 RSU081 o Page 6 _Doame&W✓rigFN�ftHUAgWYNI�-TFE WINDSORnP CaIc=MIB FromDoorfaoesN -�d- wrightsoft® Duct System Summary o: Entire House By. QUICK CALCS, INC. 317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax T72-466-6796 Email: QUICKCALCS@AOL.COM Project• • For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL Heating Cooling External static pressure 0 in H2O 0 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.000/0.000 in H2O Lowest fiction rate 0 in/100ft 0 in/100ft Actual airflow 1160 clam 1160 clim Total effective length (TEL) 0 ft Supply Branch Detail Table Name Design (Bluh) Htg Minn) Clg (dm) Design FR Diam (in) H x W (in) Dud Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 364 25 16 0 0 Ox 0 ShMt 0 0 BEDROOM c 2788 119 126 0 0 Ox0 ShMt 0 0 BEDROOM2 h 2587 117 117 0 0 Ox0 ShMt 0 0 BEDROOM2-A h 2587 117 117 0 0 0x0 ShMt 0 0 BEDROOM -A C 2788 119 126 0 0 Ox0 ShMt 0 0 ENTRY h 1047 72 47 0 0 Ox0 ShMt 0 0 GREAT/DINING c 2855 108 129 0 0 Ox0 ShMt 0 0 GREATIDINING-A C 2855 108 129 0 0 OX 0 ShMt 0 0 GREAT/DINING-B C 2855 108 129 0 0 Ox0 ShMt 0 0 KITCHEN C 725 31 33 0 0 OXO ShMt 0 0 LAUNDRY In 520 48 23 0 0 Ox0 ShMt 0 0 M. BATH h 811 49 37 0 0 Ox 0 ShMt 0 0 MASTERBATH h 595 43 27 0 0 Ox0 ShMt 0 0 Room? C 2167 92 98 0 0 Ox0 ShMt 0 0 WIC C 214 3 10 0 0 Ox0 ShMt 0 0 Return Branch Detail Table Name Grille Size (in) Htg (ctm) Clg (dm) TEL (it) Design FR Veloc (ipm) Diann (in) H x W (in) Stud/Joist Opening (in) Dud Mat Trunk rb1 OxO 1160 1160 0 0 0 0 Ox 0 ShMt Wrightsoft• 2021Jan1213:18:19 ^- RigaSdte@Lhiwrml201919.021 RSL[08101 Page 1 ACM ...DowrertslWrighlaoft HVACYWYNNE-THE WINDSORnp CaIc=MIB FroN Doorfao=s N