HomeMy WebLinkAboutEnergy Efficiency CodeFORM R405-2020
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 }
1. New construction or existing New (From Plans)
10. Wall Type01432.0 sgft.)
insulation Area
2. Single family or multiple family Detached
p y
a. Concrete Block - int Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft'
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 3
d. NIA
R= ft2
11. Ceiling Types (1783.0 sgft.)
Insulation Area
5. is this a worst case? Yes
a. Under Attic (Vented)
R=30.0 1753.00 ft
6. Conditioned floor area above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. N1A
R= ft2
12. Ducts
R ft2
7. Windows(151.4 s ft.) Description Area
q
a_ Sup: Attic, Rat: Attic, AH: Attic
6 195
a. U-Factor. Sgl, U=1.02 111.36 ft2
SHGC: SHGC=029
b. U-Factor: Sgl, U=1,11 40.00 ft2
13. Cooling systems
kStu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor. NIA ft2
SHGC:
Area Weighted Average Overhang Depth: 2,850 ft.
14, Heating systems
kBtu/hr Efficiency
Area Weighted Average SHGC: 0.285
a. Electric Heat Pump
34.8 HSPF:$.50
8. Skylights Area
c. U-Factor:(AVG) NIA ft2
15. Hot water systems
SHGC(AVG): N/A
a. Electric
Cap: 40 gallons
9. F1oorTypes (1753.0 sgft.) Insulation Area
EF:0.970
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 €N
b. Conservation features
b. N/A R= ft2
None
C. N/A R= ft2
16. Credits
None
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 49.38
PASS
Total Baseline Loads: 50.69
I hereby certify that the plans and specifications covered by
Review of the plans and
O -JOE
this calculation are in compliance with the Florida Energy
specifications covered by this
�s y O*A
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
w
'
DATE: 1-12-20
this building will be inspected for
compliance with Section 553.908
>
I hereby certify that this building, as designed, is in ompliance
Florida Statutes.
1,
{'0
with the Florida Energy Code. r
We
OWNER/A
BUILDING OFFICIAL:
DATE: t
DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402AA A and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (11402.4.1.2).
1112/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O F8C 7th Edition (2020) Compliant Software Page 1 of 6
FORM R405-2020 INPUT
SUMMARY CHECKLIST mr-rvn
PROJECT
Title: WYNNE THE WINDSOR IMP
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot #
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT
Rotate Angle: 180
Street:
THE W INDSOR
Permit Office: ST. LUCIE COUNTY
Gross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE,
Family Type: Detached
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location TMY Site 97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1753 14024
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 MASTER BEDROO 224
1792 No
0
1
1
Yes
Yes
Yes
2 WIC 63
504 No
0
1
No
Yes
Yes
3 MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
4 M. BATH 61
488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2 180
1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R 588
4704 No
2
1
Yes
Yes
Yes
8 KITCHEN 209
1672 Yes
0
1
Yes
Yes
Yes
9 BATH 50
400 No
0
1
Yes
Yes
Yes
10 HALL 25
200 No
0
1
No
Yes
Yes
11 FOYER 92
736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3 169
1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 ft 0
224 ft'
__
0 1
0
2 Slab -On -Grade Edge Insulatio
WIC 1ft 0
63 ft`
_-
0 1
0
3 Slab -On -Grade Edge Insulatio MASTER BATH 8 ft 0
56 ft2
_—_
0 1
0
4 Slab -On -Grade Edge Insulatio
M. BATH 7 ft 0
61 ft'
—
0 1
0
5 Slab -On -Grade Edge Insulatio
LAUDRY 1 ft 0
36 ft`
--_
0 1
0
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 6
FORM R405-2020 IIVru I bUMPRAKT t+11`711:l,f\LIA I K=rvK I
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6 Slab -On -Grade Edge Insulatio
BEDROOM 2 12 ft
0
180 ft2
--
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft2
--_
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN 11 ft
0
209 ft2
---
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft2
- — -
0
1
0
10SIab-On-Grade Edge Insulatio
HALL t ft
0
25 ft2
---
0
1
0
11SIab-On-Grade Edge Insulatio
FOYER 9 ft
0
92 ft2
--
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 ft
0
169 ft2
-_-
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1847 ft2
0 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
_
i Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
_
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft,
0.1
Wood
_
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 ft2
0.1
Wood
_
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
_
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
_
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
_
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
_
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM3
30
Blown
169 ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
0
_ 1
NE=>SW Exterior Concrete Block - Int InsMASTER BE
4.1 16
0 8
0
128.0 ft2
0
0
0.3
0
_ 2
SW=>NE Exterior Concrete Block - Int InsNASTER BE
4.1 7
0 8
0
56.0 ft2
0
0
0.3
0
3
NW=>SE Exterior Concrete Block - Int InsMASTER SE
4.1 14
0 8
0
112.0 ft2
0
0
0.3
0
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 3 of 6
eneAe PAnr-'>n9n INPIIT SI IMMARY CHECKLIST REPORT
WALLS
Adjacent
cavity Width
Height
Sheathing Framing
Solar
Below
it T.
Space
WMI lype
-4 NE=>SW Exterior
Concrete Block - Int InsMASTER SA
4.1 8
0
8 0
64.0 T
0
0
0.3
0
5 NE=>SW Exterior
Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft'
0
0
0.3
0
6 NE=>SW Exterior
Concrete Block - Int Ins8EDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
-7 SW=>NE Exterior
Concrete Block- Int Ins(DINING/GRE
4A 30
0
8 0
240.0 fV
0
0
0.3
0
-8 NW=>SE Exterior
Concrete Block -Int InsfilINING/GRE
4.1 20
0
8 0
160.0 ft'
0
0
0.3
0
_9 SW=>NE Exterior
Concrete Block- Int lnsulKITCHEN
4.1 11
0
8 0
88.0 ft'
0
0
0.3
0
10 NE=>SW Exterior
Concrete Block - Int Insul BATH
4.1 5
0
8 0
40.0 ft'
0
0
0.3
0
_ 11 SE�NW Exterior
Concrete Block - Int Insul FOYER
4.1 8
0
8 0
64.0 ft'
0
0
0.3
0
12 SW=>NE Exterior
Concrete Block - Int Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
13 NE=>SW Exterior
Concrete Block- Int InsBEDROOM 3
4.1 13
0
8 0
104.0 fP
0
0
0.3
0
14 SW=>NE Exterior
Concrete Block - Int InsGEDROOM 3
4.1 1
0
8 0
8.0 ft'
0
0
0.3
0
15 N=>S Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 fP
0.23
0.3
0
DOORS
# Omt
Door Type Space
Storms
U-Value
I�
Area
FtWidth
In
FHeightln
1 SE=>NW Insulated FOYER
None
.39
3
3
6 8
21.7f2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
Overhang
V # Omt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>SE 3
Metal Low-E Single Yes
1.02 0.29
Y
32.4 ft'
1 ft 0 in
1 ft 4 in
Drapes/blinds
Exterior 5
_ 2 NE=>SW 5
Metal Low-E Single Yes
1.02 0.29
Y
6.9 ft%
1 ft 0 in
1 ft 4 in
None
None
_ 3 NE=>SW 6
Metal Low-E Single Yes
1.02 0.29
Y
16.2 ft'
1 ft 0 in
1 ft 4 in
None
None
4 SW=>NE 7
Metal Low-E Single Yes
1.02 0.29
Y
39.8 ff
1 It 0 in
1 It 4 in
None
None
5 NW�SE 8
Metal Low-E Single Yes
1.11 0.27
Y
40.0 IF
8 It 0 in
t It 4 in
None
None
6 NE=>SW 13
Metal Low-E Single Yes
1.02 029
Y
16.2 ft'
1 It 0 in
1 ft4 in
Dmpes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft' 806 ft=
26 it
8 ft
71
INFILTRATION
# Scope Method $LA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000254 1168.7 64.12
120.37
.0902
5
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 4 of 6
=norm Dnnr,_')r%0n IMPI IT RI IMMARY CHFCKI 1ST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Stock
Ducts
1 Electric Heat Pump/
Split
Sing[ HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 Central Unit/
Split
Sing] SEER: 15 34.8 kBtu/hr cfm
0.85 1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Can # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft
DUCTS
/ — Supply —
— Return —
Air
CFM 25
CFM25
HVAC #
V/ # Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT ON RLF
Heat Cool
_ 1 Attic 6 195 ft-
Attic
55 ft- Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Coo]in [[ �Jan [[ ]] Feb ((�� Mar
Heating [X] Jan [XJ Feb fX1 Mar
] A r
E ] Apr
r ] May [X� Jun [JC) Jul
] may [ I Jun [ ] Jul
AugX�
Aug
Se
1 Sep
Oct Nov
Oct Nov
f[X1] Dec
Dec
Venting [[ ]) Jan tt 11 Feb [[�X1] Mar
tx)
4 ) [ 1 Jun t 1 Jul
III 777 Aug
E 7 Sep
X
j ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2 3
4 5 6
7
8
9 10 11
12
Cooling (WD) AM 78
78 78
78 78 78
78
78
78 78 78
78
PM 78
78 78
78 78 78
78
78
78 78 78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78 78 78
78
PM 78
78 78
78 78 78
78
78
78 78 78
78
Heating (WD) AM 68
68 68
68 68 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
68
68
68 68 68
68
Heating (WEH) AM 68
68 68
68 68 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
68
68
68 68 68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(B lbs/sq.ft.
0 ft-
oft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft'
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft'
ft
0.3
MASTER BATH
Default(B lbslsq.ft.
W
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft'
ft
0.3
LAUDRY
Default(8 Ibs/sq.ft.
ft'
ft
0.3
BEDROOM 2
Default(8 lbslsq.ft.
w
ft
0.3
DINING/GREAT R
nofnultra Ibs/so.ft.
ft'
ft
0.3
KITCHEN
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC An Edition (2020) Compliant Software Page 5 of 6
FORM R405-2020
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8 lbs/sq.ft.
ft' ft 0.3
BATH
Default(S lbs/sq.ft.
ft' ft 0.3
HALL
Default(8 lbs/sq.ft.
W ft 0.3
FOYER
Default(8 lbsts.ft.
ft' ft 0.3
BEDROOM 3
1/122021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 6 of 6
2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE W INDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number.
U
Owner. Jurisdiction:
w
x
Design Location: FL, Fort Pierce
O
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceilinglsoffit
Ceiling/attic
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
Walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
I skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity, insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace wall
.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
cavities shall be filled by insulation that on
Narrow cavities
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the finished surface.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Dinno and wirino
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box o
The air barrier shall be installed behind electrical or communication
I
exterior
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC supply and return register boots that penetrate building
thermal envelope shall be sealed to the sub -floor, wall covering or
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed In a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sorinkleE cover Plates and watts Or ;Wfinc5___ _
I
—
a. In addition, inspection or log wars snan De in accuruanre win, u is plvrmioua ul -.. -
1/12/2021 1:15 PM ErtergyGauge® USA 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
FORM R405-2020
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the EnergyPerformance Index, the more efficient the home.
1. New construction or existing
Z Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft')
7. Windows*' Description
a. U-Factor: Sgl, U=1.02
SHGC: SHGC=0.29
b. U-Factor. S91, U=1.11
SHGC: SHGC=0.27
c. U-Factor. N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Skylights Description
a. U-FactogAVG): N/A
SHGC(AVG): NIA
THE WINDSOR, FT. PIERCE, FL,
New (From Plans)
10. Wall Type and Insulation
Insulation
Area
a. Concrete Block - Int Insul, Exterior
R=4.1
1224.00 ft'
Detached
b. Frame - Wood, Adjacent
R=11.0
208.00 ft'
1
c. N/A
R=
ft-
3
d. N/A
R=
ft'
11. Ceiling Type and insulation level
Insulation
Area
Yes
a. Under Attic (Vented)
R=30.0
1753.00 ft2
1753
b. Knee Wall (Vented)
R=19.0
30.00 ft2
c. N/A
R=
ft2
Area
12. Ducts, location & insulation level
R ft2
111.36Area
ft'
a. Sup: Attic, Ret: Attic, AM: Attic
6 195
40.00 ft'
13. Cooling systems
kStu/hr
Efficiency
ft2
a. Central Unit
34.8
SEER:15.00
ft2
2.850 ft.
0.285
Area
ft2
9. Floor Types Insulation Area
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft'
b. N/A R= ft2
c. N/A R= ft'
14. Heating systems
a. Electric Heat Pump
15. Hot water systems
a. Electric
b. Conservation features
None
Credits (Performance method)
1 certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant fe res. 1
Builder Signature: Date:
Address of New Home: \1Z �;I'c-ck City/FL Zip: �� •� Q
kBtu/hr Efficiency
34.8 HSPF:8.50
Cap: 40 gallons
EF: 0.97
None
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code,
Energy Conservation, contact the Florida Building Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
1/12/2021 1:15 PM EnergyGauge® USA 7.0.00 - FlaRss2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1
Project SummaryJob:
wr�ghtsofk® Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LN., Fr. PIERCE, FL 34W Phone; 772-066-6799 Fax 772.466-6796 Email: QUICKCALCS@AOL.rOM
Project• •
For. WYNNE DEVELOPMENT
THE W INDSOR, FT. PIERCE, FL
Notes:
Design Information
Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42
OF
Outside db
OF
Inside db 70
OF
Inside db
75
F
Design TO 28
OF
Design TO
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
grAb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure 21542
Btuh
Structure
16420
Btuh
Duds 6191
Central vent (0 cfm) 0
Btuh
Btuh
Duds
Central vent (0 dm)
9337
0
Btuh
Btuh
none
e)
Humidification 0
Btuh
Blower
0
Btuh
Piping 0
Btuh
Equipment load 27734
Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible
load
24470
Btuh
Method Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Average
Fireplaces
0
Structure
2495
Btuh
Ducts
2546
Btuh
Central vent (0 cfm)
0
Btuh
Heat'
Area
Coolingg
(none)
(fP) 1753
1753
Equipment latent load
5041
Btuh
Volume(fF) 16478
16478
Airchanges/hour 0.38
0.20
Equipment Total Load (Sen+Lat)
29511
Btuh
Equiv.AVF(dm) 104
55
Req. total capacity at 0.70 SHR
2.9
ton
Heating Equipment Summary
Cooling Equipment Summary
Make Carrier
Trade CARRIERAIR CONDITIONING
Model 25HBC536XO30
AHRI ref 7914585
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Airflowfactor
Static pressure
Space thermostat
Capacity balance point = 36 OF
I.11i
34600
Bluh @ 47-F
27
OF
1160
cfm
0.042
cfrn/Btuh
0
in H2O
Backup:
Input=7kW, Output= 230G9 Btuh, 100 AFUE
Make Carrier
Trade CARRIERAIR CONDITIONING
Cond 25HBC536A*030
Coil FX4DN(B,F)037
AHRI ref 7914585
Efficiency 12.0 EER,15 SEER
Sensible cooling
24360
Btuh
Latent cooling
10440
Btuh
Total cooling
34800
Btuh
Actual airflow
1160
cdrn
Airflowfactor
0.045
chVBtuh
Static pressure
0
in H2O
Load sensible heat ratio
0.84
Calculations approved byACCAto meetall requirements of Manual J 8th Ed
wrightsoft^ 2021-JaM213:18:18
RigftSute®Unv ml 201919.021 RSU08101 Page 1
...D'amerts\Wnghwft HVAC1W7NNE-THEWIND50Rnp Calc=M,18 FroNDoorfaces: N
wrightsaw Right-M Worksheet o�e:
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LN.,FT. PIERCE, FL 34946 Ptnre: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
Entire House
BEDROOM
2
F�osed xall
207.6 It
41.0 ff
3
Room height
9.4 ft d
9.4 ft heaUmcl
4
Room tlimensions
14A x 20.0 ft
5
Room area
1753A iR
280.0 ft
Ty
Construction
U-value
Or
HTM
Area (�
Load
Area (fl
Load
number
(BWhV-7)
(BluhM
or perimeter (ft)
(BWh)
or perimeter (ft)
(Bhrh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gros
N/P5
Heat
Cool
6
13A4=
0.143
n
4.00
2.55
649
596
2386
1517
66
66
263
167
1Adom
1270
n
3556
34.77
15
0
533
522
0
0
0
0
4A5-20m
0.770
n
21-96
1931
38
0
815
730
0
0
0
0
W
13A4=
0.143
re
4.00
255
27
27
106
68
0
0
0
0
11
13A-4ors
0.143
a
4.00
2.55
141
100
400
255
0
0
0
0
I---G
1Ac1am
1270
a
3556
87116
20
1
711
1741
0
0
0
0
I—D
1100
0.390
e
10.92
1131
21
21
229
238
0
0
0
0
W
13A4=
0.143
se
4.00
2.55
27
27
106
68
0
0
0
0
W( -
13Aha¢
0.143
a
4.00
2S5
536
530
2121
1349
188
188
753
479
I---C
1Aciam
1270
s
35.56
34.77
6
6
213
209
0
0
0-
0
W
13A4acs
0.143
w
4.00
2.55
320
255
1022
649
132
108
432
275
{---G
tA4=
1270
w
35.56
54.53
12
1
415
636
12
1
415
636
4L—GG
1A.cl=
1270
w
35.56
54M
12
1
427
654
12
1
427
654
4Arr2om
0.770
w
21.56
45.63
41
2
880
1862
0
0
0
0
P
12C-Dam
0.091
255
128
254
254
647
326
0
0
0
0
C
16A30md
0.032
-
0190
232
1753
1753
1571
4067
280
280
251
650
F
22A-tpl
0.989
-
27.69
OAO
1753
208
5748
0
280
41
1135
0
6
c)AEDeucvrsion
397
488
Envelope low/gain
1
18331
15285
36761
3349
12
a) Infiltration
3211
90
729
205
b) Rccmvennlilation
0
0
0
0
13
Internal gains: Ooarpans@ 230
1
230
0
0
0
Appliarrndother
0
Subtotal(lines6to13)
21542
16420
4405
3554
Lose external load
0
0
0
0
0
0
Les transfer
0
0
0
0
0
0
Redisb)buhon
21542
16420
4405
3554
14
Subtotal
29%
57%
6191
9337
29%
57%
1266
2021
15
Dud loads
Total room load
27734
25757
5671
237
W75
251
Air required (dm)
1160
1760
-*- Mel-W~tW fe RigttSuL@lkiversa1201919.021 RSU08101
.. Ooa rtslWng%oftHVAQWYNNE-THEWINDSORnp Calc=W8 Front Doorfaces:N
2021-JaM213:18:18
Page 1
wrighWIDW Right,JO Worksheet Job:
Entire House per:
QUICK CALCS, INC. By.
317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fa1c 772-4666796 Email: QUICKCALCS m( AOL.COM
1
Room name
WIC
MASTER BATH
2
EVOSelwall
0It
90It
3
Room height
9.4 It heaVmol
9.4 It hea*ool
4
Room dimensions
7.0 x 9.0 It
7.0 x 9.0 It
5
Roomarea
630 ff
63.0 IF
Ty
Consivction
U-value
Or
HTM
Area OF)
Load
number
(BWhAF-°F)
(8whr)
or pen meter (ft)
(Bluh)
orperimeter(t)
(BWh)
Heat
Cool
Gros
NIP/.
Heat
Cool
Gros
WP/S
Heat
Cool
6
13A-4ccs
0.143
n
4.00
2.55
0
0
0
0
0
0
0
0
1Ac1cm
1270
n
3556
34.77
0
0
0
- 0
0
0
0
0
4AS2orn
0.770
n
21.56
1931
0
0
0
0
0
0
0
0
w
13A4ocs
0.143
ne
4.00
2-55
0
0
0
0
0
0
0
0
11
13A =
0.143
a
4.00
2.55
0
0
0
0
0
0
0
0
�('
-to-clom
1270
a
3556
87.06
0
0
0
0
0
0
0
0
�D
11D0
0.390
a
1092
11.31
0
0
0
0
0
0
0
0
w
13A4o,s
-13A4ocs
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
W/
0.143
s
4.00
255
0
0
0
0
85
85
339
215
�C
1Aclom
1270
s
35s6
34.7
o
0
0
0
0
0
0
0
13A4ots
0.143
w
4.00
255
0
0
0
0
0
0
0
0
1Aclom
1270
w
3556
54M
0
0
0
0
0
0
0
0
tAclom
1270
w
3556
54M
0
0
0
0
0
0
0
0
4A520m
0.770
w
2156
45.63
0
0
0
0
0
0
0
0
P
12C-Qw
0.091
2.55
128
0
0
0
0
0
0
0
0
C
16A30md
0.032
-
0.90
2.32
63
63
56
146
63
63
56
146
F
22A-tpI
0989
-
27.69
0.00
63
0
0
0
63
9
249
0
6
c)AED exarsian
-10
1
-28
Envelope loss(gain
56
136
644
334
12
a) Infiltration
0
0
160
45
b) Room ventlaton
0
0
0
0
13
Internal gains: Ooolpants@ 230
0
0
0
0
Applianoes/other
0
0
Subbfal(1ines6to13)
56
136
804
379
Lesextemallozd
0
0
0
0
Lestransfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
56
136
boa
379
15
Duct loads
29i
57i
16
n
zs°o
57^i
231
216
Total mom load
73
214
1036
595
Airrequired(dm)
3
10
43
27
Calculations approved byACCAto meet all requirements of Manual J 8th Ed
Pogtt79.021 2021Jan-1213:18:18
Aftk ...DomrtslWrg4oftHUACWYNNE-THEWINDSORntp Calc=hUB FrontDoortaces: N Page 2
t t wrightsoW Right-M Worksheet Da
Entire House BY
By.
QUICK CALCS, INC.
c17 RT I I IrJP I N F PIERCE. FL 34946 Phore:772-4666799 Fax 772-466-6796 Email: QUICKCALCS@AOLCOM
1
Room name
MBATH
KrrCHEN
2
EVOWdMIl
8.0ft
8.0ft
3
Room height
9.4 ft heatbDd
9A ft hewoDd
4
Room dimensions
7.0 x 8.0 ft
1.0 x 172.0 It
5
Room area
56.0 fF
172D fP
Ty
Construction
U-value
Or
HTM
Area ("
Load
Area (ilk
Load
number
(BWhtl-T)
(BWh4M
or perimeter (ft)
(13Wh)
or perimeter (ft)
(B41h)
Heat
Cool
Grote
N/PS
Heat
Cool
Grass
NrPS
Heat
Cool
6
13A-0o¢
0.143
d
4.00
2-%
0
0
0
0
0
0
0
0
0
0
0
0
1A.clom
1270
n
35M
34.77
0
0
0
0
0
0
0
0
4A5-tom
0.770
n
21-%
1931
0
0
0
0
W
13A-4orss
0.143
ne
440
2.55
0
0
0
0
0
0
0
0
0
0
11
V�/
13A-4ors
0.143
a
4.00
2S5
0
0
0
0
0
0
0
F—f
tActom
1270
a
3556
87A6
0
0
0
0
0
0
-0
0
0
t_.D
11DO
0"
a
10.92
1131
0
0
0
0
0
0
0
0
w
13A-4ocs
0.143
se
4A0
2.55
0
0
0
0
0
0
t13AAocs
0.143
s
4.00
255
75
69
277
176
0
0
0
0
0
—G
to-clom
1270
s
3556
34.77
6
6
213
209
0
0
0.
y/
13A-4ors
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
0
)---G
IA -Om
1270
w
3556
5453
0
0
0
0
0
0
0
IL----GG
1Aclom
1270
w
3556
54M
0
0
0
0
0
0
0
0
4AS2om
0.770
w
21M
45.63
0
0
0
0
0
0
0
192
0
96
P
12C-Ow
0.091
-
255
126
0
0
0
0
75
75
C
16A30md
0.032
-
0.90
2.32
56
56
50
130
172
172
154
399
F
22A-Ipl
0.989
-
27.69
0.00
56
8
222
0
172
8
222
0
6
C)AEDexivlson
a
-34
Envelope lossrgain
762
477
567
462
12
a) Imitation
142
40
0
0
0
0
b) Roomventilation
0
0
13
Infemalgairs: O=pants@ 230
0
0
0
0
0
Appltanoadalver
0
Subtolal(lines6to13)
9w
517
567
462
Lesse>aemal load
0
0
0
0
0
0
Lesstransfer
0
0
0
0
0
0
Redls4ibuton
904
517
567
462
14
Subtotal
29%
57%
260
294
29%
5n.
iGi
263
15
Dudloads
Total room load
1164
49
811
37
730
31
725
33
Air required(dm)
M ►Nsv1't^
A A � RigkTHEWINriSORIW GIII.021 Frcrt1 o
,.Dowrer6lWdgt>5o11tNAgWYNNE-THE WINDSORnq C31c=M18 FroRDoorfaces N
2021Jan1213:18:18
Page 3
1 wrightsW Right-J® Worksheet °�`
Dat
Entire House
By.
QUICK CALCS, INC.
317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Plore: 772-466-6799 Fax 7724666796 Email: OUICKCALCS@AOL.COM
1
Room name
BATH
BEDROOM2
2
Eposetlxall
5.0 It
42.6 it
3
Roam height
9.4 it heatbool
9.4 It I'mat(000l
4
Room dimer one
9.0 x 6.0 it
1.0 x 204.0 it
5
Room area
45.0 T
204.0 1F
Ty
Construction
U-value
Or
HTM
Area (fl0
Load
Area (ft0
Load
number
(Btuhd--q
(BWhAn
or perimeter (it)
(Bt1h)
or perimeter (ft)
(Bluh)
Heat
Cool
Gros
NIPS
Heat
Cool
Gros
N/PIS
Heat
Cool
6
%t
13A-4ocs
0.143
n
4.00
2.55
47
47
188
12D
132
132
527
335
to-ctom
1270
n
3556
34.77
0
0
0
0
0
0
0
0
L�---GG
4A5-2om
0.770
n
2155
19.31
0
0
0
0
0
0
0
0
W
13A4ccs
0.143
ne
4.00
255
0
0
0
0
27
27
106
68
11
W
13AAocs
0.143
a
4-DO
255
0
0
0
0
85
65
259
164
�-G
1Aciom
1270
a
3556
87.06
0
0
0
0
20
1
711
1741
L-D
1100
0.390
a
M92
11.31
0
0
0
0
0
0
0
0
W
13A-4=
0.143
se
4.00
255
0
0
0
0
27
27
106
68
l�/
13A4ors
0.143
s
4.00
2.55
0
0
0
0
132
132
527
335
I-C
1Ac1om
1270
s
3556
34.77
0
0
0
0
0
0
0
0
13A4=
0.143
w
4.00
2.55
0
0
0
0
0
0
0
0
1Actom
1270
w
35.56
64.53
0
0
0
0
0
0
0
0
1Ac1cm
1270
w
3556
54.53
0
0
0
0
0
0
0
0
4A5-2om
0.770
w
2156
45.63
0
0
0
0
0
0
0
0
P
12C-ow
0.091
2,55
128
0
0
0
0
0
0
0
0
C
16A30md
0.032
-
0.90
232
45
45
40
104
204
204
183
473
F
22A-tpl
0289
-
27.69
0.00
45
5
138
0
204
43
4179
0
6
c)AEDexcumon
47
-99
Errvelope loss/gain
367
207
1
35991
3085
12
a) Infiltration
89
25
1
758
214
b) Roomvantilafion
0
0
0
0
13
Intemalgaim Oovpants@ 230
0
0
0
0
0
Applianceslotller
0
Subtotal(lirmtib13)
456
232
4357
3299
Les exEmal load
0
0
0
0
0
0
0
0
Lestransfer
0
0
0
0
Redistribution
456
232
4357
32M
14
15
Subtotal
Ductloads
29°/
57°/,
131
132
29%
57%
12521
1876
Total room loatl
587
2s
364
16
5609
235
5175
233
Airrequired(cim)
- wr7ghisnl't'
.4 A RigkTHEWItlrSOP-rup Ct9.021RSU0810t
-.Dodmer6\Wnghlv�ft HUgG1WYNNE-THE WINDSORrw CaIc=MIB FroNDoorfaces:N
2021 %tarF1213:18:18
Page 4
+ wrightsoW Right-J@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC. 8r-
317 ST.. LUCIE LN,Fr.. PIERCE, FL 34W Plum: 772-466-6799 Fax 772-466-6796 Emil: QUICKCALCS@40LCOM
1
Room name
ENTRY
LAUNDRY
2
3
6yomtivall
Room height
18.0 It
9.4 ft heaV000l
13.0 It
9.4 It heaVowl
4
5
Room dimensions
Room area
1A x 92D ft
92.0 ff
7.0 x 6.0 It
42.0 iF
Ty
Corxruction
number
U-value
(BtuhfiF-°F)
Or
HTM
(Blow
Area
or perimeter (ft)
Load
(BWh)
Area(1F)
or perimeter (ft)
Load
(8tuh)
Heat
Cool
Gross
NIPS
Heat
Cool
Grow
NIPS
Heat
Cool
6
11
yl
1344ors
1AtNom
4A5-2om
13A4o s
13A4=
1Ac1an
11DO
1344as
1344a
tActan
134-0ors
1Aclorn
1Acicm
4A5-2om
12C-02v
16AmMrnd
22A-y11
0.143
1270
0.770
0.143
0.143
1270
0.390
0.143
0.143
1270
0.143
1270
1270
0.770
OA91
0.032
0.989
n
n
n
ne
a
a
a
se
s
s
w
w
w
w
-
-
4.00
3556
2156
4.00
4A0
35M
1092
4.00
4.00
3556
40
35.56
3556
2156
2.55
0.90
27b9
2.55
34.77
19.31
2.55
2.55
87.06
11.31
2.55
2.55
34.77
255
54.53
54.53
45.63
128
2.32
0.00
0
0
0
0
56
0
21
0
0
0
0
0
0
0
113
92
92
0
0
0
0
35
0
21
0
0
0
0
0
0
0
113
92
18
0
0
0
0
142
0
229
0
0
0
0
0
0
0
287
82
498
0
0
0
0
90
0
238
0
0
0
0
0
0
0
145
213
0
0
0
0
0
0
0
0
0
56
0
0
0
0
0
66
42
42
0
0
0
0
0
0
0
0
56
0
0
0
0
0
66
42
13
0
0
0
0
0
0
0
0
226
0
0
0
0
0
166
38
360
0
0
0.
0
0
0
0
0
144
0
0
0
0
0
84
97
0
II --GC
w
�C
�D
W
lM
_G
Vy
I-G
P
C
F
6
c)AED excursion
49
-24
Envelopeloss�gain
1239
637
-191
301
12
a) InfiNaton
b) Roomsentilation
107
0
30
0
107
0
30
0
13
Internal gains Omupants@ 230
0
0
0
0
Applianceother
0
0
Subtotal (lines 6 to 13)
1346
667
898
331
14
Less exdemal load
Lesstransfer
Redisbibulion
Subtotal
0
0
0
1346
0
0
0
667
0
0
0
898
0
0
0
331
15
Ductloads
29%
570/6
387
379
29%
57%
258
188
Total room load
Arregwred(Um)
1733
72
1047
47
1156
48
520
23
Calculations approved bvACCAto meet all read rements of Manual J 8th Ed
wrl9htsoTc' 2021-Jan-1213:18:18
Rigt-THEWINDSOsal p Calc.021 RSU081 o Page5
...DoomeNslWnghLsoftHUAL1WYNNE-THE WINDSORnp CaIc=MJB Front�orfaces:N
F wrightsoft° Right-JO Worksheet 'OIX
Entire House Date:
QUICK CALCS, INC.
317 ST-LUCIE LN, Fr. PIERCE, FL 34946 PIom:772466-6799 Fax 772-4666796 Email: OUICKCALCS@AOL.COM
1
Room name
GREATANNN1G
Rcom7
2
Exposed wall
500 ft
13.0 ft
3
Room height
9.4 ft heal
9A ft heaftol
4
Room dimensions
1.0 x 557.0 ft
13A x 13D ft
5
Room area
5670 ft'
169.0 IF
Ty
Construction
U-value
Or
HTM
Area
Load
Am
number
(SWh49 flF-
(eWhfll'`)
or penm� (ft)
(BWh)
or perimeter (It)
(BGih)
Heat
Cool
Gros
N/Pr5
Heat
Cool
Gross
UPS
Heat
Cool
6
W
134-0as
0.143
In
4110
2.55
2B2
244
978
622
122
107
429-
273.
-IIA-dom
1270
-n
3556
34.77
0
0
0
0
15
0
533
522
4A5-2om
0.770
n
21M
1931
38
0
816
730
0
0
- 0.
0
W
1344ors
0.143
ne
4.00
Z.55
0
0
0
0
0
0
0
0
11
1344ors
0.143
a
4.00
2-95
0
0
0
0
0
0
0
-0
11--DC
1A-dom
1270
a
3556
87.06
0
0
0
0
0
0-
0
0
11DO
03M
a
10.9
- 1131
0
0
0
0
0
0
—. 0-
- 0
W
13A-4os
0.143
se
4.00
2.55
0
0
0
0
0
0
0
0
Iql -
13A-4os
0.143
s
4A0
2.55
0
0
0
0
0
- 0
- ' -0
- 0
L—G
1Ac1arn
1270
s
3556
34.77
0-
0
0
0
0
o
< o-
- 0
W
13AAo s
0.143
w
4.()0
2.55
188
147
589
375
0
0
0
0
IA-d m
1270
w
3556
6453
0
0
0
0
0
0
0
0
1Actam
1270
w
3556
5453
0
0
0
0
0
0
0
0
ll�--GGG
4A5-2om
0.770
w
2156
45M
41
2
880
1862
0
0
0
0
P
12C )w
OD91
-
255
128
0
0
0-
0
- 0
0
0-
0
C
16A-30md
OAS
-
0.90
232
557
567
508
1315
169
169
151
392
F -
22Ar%S
0289
-
27.69
0.00
-567
- 50
13B5
0
169-
13
- .360
0
6
c)AFD e=rson
307
-100
Envelope loss'9ain
5154
5210
1474
1086
12
a) Nitration
889
251
231
65
b) Roomeentilabon
0
0
0
0
13
Memel gains: O=pants@ 230
0
0
1
230
Appliwoesother
0
0
SubtoIW(l1nes6to13)
6043
5461
1705
1391
Les eximal load
0
0
0
0
Lestander
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
6043
5461
1705
1381
15
Dud loads
29%
57%
1737
3105
29%
57%
490
785
Total room load
7780
85%
2195
2167
Air required (dm)
3251
92
98
Calculations approved bvACCAto meet all reouirements of Manual J 8th Ed
!� 2021-Jar-12 13:18:18
'2cw RiE-THE INDSOsa1 p Calc-021 RSU081 o Page 6
_Doame&W✓rigFN�ftHUAgWYNI�-TFE WINDSORnP CaIc=MIB FromDoorfaoesN
-�d- wrightsoft® Duct System Summary o:
Entire House By.
QUICK CALCS, INC.
317 ST. LUCIE LN., Fr. PIERCE, FL 34946 Phone: 772-466-6799 Fax T72-466-6796 Email: QUICKCALCS@AOL.COM
Project• •
For. WYNNE DEVELOPMENT
THE WINDSOR, FT. PIERCE, FL
Heating
Cooling
External static pressure
0
in H2O
0
in H2O
Pressure losses
0
in H2O
0
in H2O
Available static pressure
0
in H2O
0
in H2O
Supply/return available pressure
0.000/0.000
in H2O
0.000/0.000
in H2O
Lowest fiction rate
0
in/100ft
0
in/100ft
Actual airflow
1160
clam
1160
clim
Total effective length (TEL)
0 ft
Supply Branch Detail Table
Name
Design
(Bluh)
Htg
Minn)
Clg
(dm)
Design
FR
Diam
(in)
H x W
(in)
Dud
Mat
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
h 364
25
16
0
0
Ox 0
ShMt
0
0
BEDROOM
c 2788
119
126
0
0
Ox0
ShMt
0
0
BEDROOM2
h 2587
117
117
0
0
Ox0
ShMt
0
0
BEDROOM2-A
h 2587
117
117
0
0
0x0
ShMt
0
0
BEDROOM -A
C 2788
119
126
0
0
Ox0
ShMt
0
0
ENTRY
h 1047
72
47
0
0
Ox0
ShMt
0
0
GREAT/DINING
c 2855
108
129
0
0
Ox0
ShMt
0
0
GREATIDINING-A
C 2855
108
129
0
0
OX 0
ShMt
0
0
GREAT/DINING-B
C 2855
108
129
0
0
Ox0
ShMt
0
0
KITCHEN
C 725
31
33
0
0
OXO
ShMt
0
0
LAUNDRY
In 520
48
23
0
0
Ox0
ShMt
0
0
M. BATH
h 811
49
37
0
0
Ox 0
ShMt
0
0
MASTERBATH
h 595
43
27
0
0
Ox0
ShMt
0
0
Room?
C 2167
92
98
0
0
Ox0
ShMt
0
0
WIC
C 214
3
10
0
0
Ox0
ShMt
0
0
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(ctm)
Clg
(dm)
TEL
(it)
Design
FR
Veloc
(ipm)
Diann
(in)
H x W
(in)
Stud/Joist
Opening (in)
Dud
Mat
Trunk
rb1
OxO
1160
1160
0
0
0
0
Ox 0
ShMt
Wrightsoft• 2021Jan1213:18:19
^- RigaSdte@Lhiwrml201919.021 RSL[08101
Page 1
ACM ...DowrertslWrighlaoft HVACYWYNNE-THE WINDSORnp CaIc=MIB FroN Doorfao=s N