Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST.LUCIE COUNTY Design Location: FL, Fort Pierce County: St.Lucie(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 10. Wall Type$1442.0 sqft.) Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul, Exterior R=4.1 1250.00 ft2 b.Frame-Wood,Adjacent R=11.0 192.00 ft2 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 2 d.NIA R= W 11.Ceiling Types (1476.0 sqft.) insulation Area 5. is this a worst case? Yes a. Under Attic(Vented) R=30.0 1446.00 ft2 6. Conditioned floor area above grade(ft2) 1446 b. Knee Wall(Vented) R=19.0 30.00 fit' Conditioned floor area below grade(ft2) 0 c.NIA R= ft= 7. Windows(141.3 sqft.) Description Area 12.Ducts R ft2 a. U-Factor. Sgl,U=1.04 101.25 ft2 a.Sup:Attic,Ret:Attic,AH:Attic 6 175 SHGC: SHGC=0.29 b. U-Factor: Sgl,U=1.11 40.00 ft2 13.Cooling systems kBtulhr Efficiency SHGC: SHGC=0.27 a.Central Unit 34.8 SEER:15.00 c. U-Factor. NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. 14•Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.2$4 a.Electric Heat Pump 34.8 HSPF:8.50 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15.Hot water systems SHGC(AVG): NIA a.Electric Cap:50 gallons 9. Floor Types (1445.5 sqft-) Insulation Area EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1445.50 ft2 b. Conservation features b.N/A R= ft2 None c.NIA R= ft2 16.Credits None Glass/Floor Area: 0.098 I�1�7�7 Total Proposed Modified Loads: 44.57 PASS Total Baseline Loads: 45.19 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARITD Y, Before construction is completed n DATE: -1 -202 this building will be inspected for compliance with Section 553.908 s ¢ I hereby certify that this building,as designed,is ig compliance Florida Statutes. with the Florida Energy Cod 'Q�WF OWNER1 G NT: BUILDING OFFICIAL-: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 1/12/2021 12:02 PM EnergyGaugeO)USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT PROJECT Tide: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot# Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST.LUCIE COUNTY Cross Ventilation: No County: St.Lucie Jurisdiction: ST.LUCIE COUNTY Whole House Fan: No City,State,Zip: FT.PIERCE, Family Type: Detached FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio BEDROOM 52 ft 0 301 ft' _- 0 1 0 2SIab-On-Grade Edge Insulatio WIC 1 ft 0 63 ft- ___ 0 1 0 3 Slab-On-Grade Edge Insulatio M.BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab-On-Grade Edge Insulatio KITCHEN 1 ft 0 192 ft' 0 1 0 5 Slab-On-Grade Edge Insulatio BATH 5 ft 0 45 ft' -__ 0 1 0 6 Slab-On-Grade Edge Insulatio BEDROOM 2 32.2 It 0 203.5 ft' ___ 0 1 0 7 Slab-On-Grade Edge Insulatio ENTRY 7 ft 0 55 W ___ 0 1 0 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 2 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab-On-Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 0 1 0 9SIab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ___ 0 1 0 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) BEDROOM 30 Blown 301 ft' 0.1 Wood 2 Under Attic(Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic(Vented) M.BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic(Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic(Vented) BATH 30 Blown 45ft2 0.1 Wood 6 Under Attic(Vented) BEDROOM 2 30 Blown 204 ft2 0.1 Wood 7 Under Attic(Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic(Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic(Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall(Vented) GREAT/DINING 19 Blown 30 ft' 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 1 NE=>SW Exterior Concrete Block-Int InsiBEDROOM 4.1 10 0 8 0 80.0 ft. 0 0 0.4 0 2 SW=>NE Exterior Concrete Block-Int InsuBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 _ 3 NW=>SE Exterior Concrete Block-Int InsuBEDROOM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 _ 4 SW=>NE Exterior Concrete Block-Int Insul M.BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block-Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _6 NE=>SW Exterior Concrete Block-Int InsBIEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 _ 7 SE=>NW Exterior Concrete Block-Int InsREDROOM 2 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 _ 8 S=>N Exterior Concrete Block-Int InsBEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 _ 9 SW=>NE Exterior Concrete Block-Int InsBIEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 _10 SE=>NW Exterior Concrete Block-Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _11 SW=>NE Exterior Concrete Block-Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0.4 0 12 SW=>NE Exterior Concrete Block-Int InsULAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _13 NE=>SW Exterior Concrete Block-Int InsOREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block-Int InstBREAT/DINI 4.1 20 0 8 0 160.0 t12 0 0 0.4 0 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 3 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 15 N=>S Garage Frame-Wood KITCHEN 11 24 8 192.0 W 0.23 0.4 0 DOORS # Ornt Door Type Space Stones U-Value Width Height Area Ft In Ft In 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>SE 3 Metal Low-E Single Yes 1.04 0.29 Y 32.9 ft' 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior 5 2 SW=>NE 4 Metal Low-E Single Yes 1.04 0.29 Y 6.9 ft' 1 ft 0 in 1 ft 5 in None None 3 SE=>NW 7 Metal Low-E Single Yes 1.04 0.29 Y 24.0 ft' 6 ft 0 in 1 ft 5 in None None 4 NE=>SW13 Metal Low-E Single Yes 1.04 0.29 Y 37.5 ft' 1 ft 0 in 1 ft 5 in None None 5 NW=>SE14 Metal Low-E Single Yes 1.11 0.27 Y 40.0 ft' 8 It 0 in 1 ft 5 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 315 ft' 315 ft' 24ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.04 139.01 .1263 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER:15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 60.9 gal 120 deg None 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 4 of 5 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ---Supply-- --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Progrannablr[e ThermostaJan t: ']N Ceiling Fans:Cooling [X� (JCl Oct Nov Dec Heating ent ng [ ]Jan [ ]FebX Mar ApMa r € May Jun [ ]Jul Aug [ ]Sep Oct Nov Dec Jun [ ]Jul Aug I 1 Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 Oft 0.3 BEDROOM Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M.BATH Defaults lbs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(81bs/sq.ft. ft2 ft 0.3 BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 ENTRY Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default(8 lbs/s .ft. ft2 ft 0.3 GREAT/DINING 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00-FlaRes202O FBC 7th Edition(2020) Compliant Software Page 5 of 5 2020 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 a AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST.LUCIE COUNTY City,State,Zip: FT.PIERCE,FL, Permit Number: Owner. WYNNE BUILDING CROP Jurisdiction: ST.LUCIE COUNTY = Design Location: FL,Fort Pierce c� COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic Y PP 9 The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace wall . Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind nininn and wirinn Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub-floor,wall covering or Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a. In addition,inspection of log walls shall be in accordance with the provisions of ICCd00. 1/12/2021 12:02 PM EnergyGaugeO USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. , FT. PIERCE, FL, 1. New construction or existing New(From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a.Concrete Block-Int Insul,Exterior R=4.1 1250.00 ft' b.Frame-Wood,Adjacent R=11.0 192.00 fF 3. Number of units,if multiple family 1 c.N/A R= ft' 4. Number of Bedrooms 2 d.N/A R= ft2 11.Ceiling Type and insulation level Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1446.00 fF 6. Conditioned floor area(ft2) 1446 b.Knee Wall(Vented) R=19.0 30.00 ft2 7. Windows** Description Area c.NIA R= ft2 a. U-Factor: SgI,U=1.04 101.25 ft2 12.Ducts,location&insulation level R ft' a.Sup:Attic,Ret:Attic,AH:Attic 6 175 SHGC: SHGC=0.29 b. U-Factor: SgI,U=1.11 40.00 ft2 SHGC: SHGC=0.27 13.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 34.8 SEER:15.00 SHGC: tl. U-Factor. N/A ft'SHGC: 14.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 3.832 ft. a.Electric Heat Pump 34.8 HSPF:8.50 Area Weighted Average SHGC: 0.284 8. Skylights Description Area 15.Hot water systems a. U-Factor(AVG): N/A ft2 a. Electric Cap:50 gallons SHGC(AVG): N/A EF:0.97 b. Conservation features 9. Floor Types Insulation Area None a.Slab-On-Grade Edge Insulation R=0.0 1445.50 ft2 Credits(Performance method) None b.N/A R= ft2 c.N/A R= ft' 1 certify that this home has complied with the Florida Energy Efficiency Code for Building OE Construction through the above energy saving features which will be installed (or exceeded) flF� F in this home before final inspection. Otherwise, a new EPL Display Card will be completed to} H based on installed Code complian m, Builder Signature: Date: Address of New Home: C\t)�'�,k City/FL Zip: GODWE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/12/2021 12:02 PM EnergyGauge®USA 7.0.00-FlaRes2020 FBC 7th Edition(2020) Compliant Software Page 1 of 1 Project Summary Job: wright5oft Entire House By. QUICK CALCS, INC. 317 ST.LUCIE LN..Fr..PIERCE,FL 34946 P1nre:772-466-6799 Fax 772466-6796 Emil:OUICKC4LCS ,AOL.COM Project • • For. WYNNE DEVELOPMENT CARLTON III,FT.PIERCE,FL Notes: Design Information Weather. Fort Pierce,FL,US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19691 Btuh Structure 16785 Btuh Duds 5900 Bah Duds 8919 Bah Central vent(0 cfim) 0 Btuh Central vent(0 cflm) 0 Btuh none (none) Humidifiption 0 Bah Blower 0 Bah Piping 0 Btuh Equipment load 25591 Btuh Use manufacturers data n Rate/swingg It mu 0.95 Infiltration Equipme ltsensible load 24418 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2065 Bah Btu Central vent(0 cfrm) 2420 Btuh Heatingg Coolingg (none) Area(f[2) 1602 1602 Equipment latent load 4493 Btuh Volume(ft') 14827 14827 Air changesthour 0.38 020 Equipment Total Load(Sen+Lat) 28912 Btuh Equiv.AVF(clm) 94 49 Req.total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIRCONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536XO30 Cond 25HBC536XO30 AHRI ref 7914585 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating input Sensiblecooling 24360 Btuh Heating output 34600 Btuh@47-F Latentcooling 10440 Bah Temperature rise 27 OF Total cooling 34800 Bah Adualairflow 1160 clim Actual air flow 1160 clim Airflowfador 0.045 cflnBtuh Airflowfador 0.045 dm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=34 OF Backup: Input=7kW, Output=23009 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wr-afte ofC 2021-JaM212:0436 �y RigltSLiL@ Uriw=1201919.021 RSU08101 Pagel ...�lWngWE ftWAC\WYNNE-THEGRP.NDC4RL7ON.rup Calc=Uk Fro`t Doorfa s:N +� wrightsow Right-J® Worksheet Jo" Entire House Date: BY QUICK CALCS, INC. 317 ST.LUCE"Fr..PIERCE.FL 34946 Prow 772-466-6799 Fax772-466.6796 Ereil:QUICKCALCS@AOL.COM 1 Room rlatli Entire House BEDROOM 2 Exposadvell 1762 it 41D it 3 Room height 93 it d 80 it heafkml 4 Room d'pnenslons 14D x 18D ft 5 Room area 16015 W 252.0 IF Ty ConLvction U-mgm Or HTM Area Load number (BWh#F-°F) (BWhd9 or part(me�r m MWh) or perun� (10 (BWh) Heat Cool Gross NIPS Heat Cool Gross NIPS Heat Cool 6 W - 134-0ocs _ 0.143 ne 4.00 255 551 513 2055 1306 - 72 - 72 288 183 1—G 1Ac1am 1270 m 35M 7043 - 38 0 1344 2662 0 0 -0 . 0 % 13A4= 0.143 se 4D0 255 128 87 348 221 0 0 0 0 I--G 1A-d m 1270 w 3556 70M 20 0 711 1419 0 0 0 0 17 1--D 11DO 0.390 se 10112 1131 21 21 229 238 0 0 0 0 W 13A4acs 0.143 -s 4,013 255 34 34 136 86 0 0 0 0 y/ 1344as 0.1 sw 4.00 255 416 390 1562 993 144 144 577 367 �C 1A-olan 12m sw 3556 70.95 6 0 213 426 0 0 0 0 �C 1Actom 1270 sx 35M 70.95 20 0 711 1419 0 0 0 0 13A41ocs 0.143 rtw 4.00 255 352 288 - 1151 -732 112 88 354- 225 T—G 1Ad m 12M rw 3556 4524 12 0 415 - 528 12 0 415 -528 1Aclom - 1270 -rwa 35M 4524 12 0 427 543 - 12 0 427 543 4A5-2Dmd 0.770 rwr 21.56 36.90 41 0 - 880 1505 - 0 . 0 0 0 P 12C-O w OD91 - 2.66 128 120 120 306 154 0 0 0 0 C - 16A30md 0= - 0.90 232 1602 1602 1435 3715 252 252 226' - 585 F 22A-tpl 0.969 - 27.69 0.00 1602 176 4878 0 252 41 1135 0 6 c)AEDemirsim 23 197 Envelope Iosslgain 16802 15970 3421 2627 12 a) Nfiwalm 2890 815 640 180 b) Room ventilation 0 0 0 0 13 Ihterrial gains: O¢ pants@ 230 0 0 0 0 Applianoe5other 0 0 Subbbl(lines(Sb 13) 19691 16785 4061 28p7 Lessa4emalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subbtal 19891 16785 4061 2807 15 Ductloads 30% 57% 5900 8919 3D% 53%j 1217 1491 Total room load 25W 5278 4298 Air required(Cm) 1160 1160 239 194 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed. Ar'� RigHSdtgtkfrerea1201919.021 RSU08101 2021-Jar+1212:04:36 m -IMWdgtrsoft HVAQWVNNE-THEGRANDCARLIONnp Calc=NW FrortOoortaces N Paget F{� wrghftWt Right,JO Worksheet Jo" Entire House Date: By. QUICK CALCS, INC. 317 ST.LUCIE LN.,Fr..PIERCE,FL 34946 Prone:772-466-6799 Fa 772-466-6796 Email:QUICKCALCS@AOL.COM 1 Room name WIC MASTER BATH 2 Bposedwall 0 ft 17.0 ft 3 Room height 8.0 it heaV000l 8.0 It heaVwol 4 Room dimensions 7.0 x 9.0 it 7.0 x 17.0 It 5 Room area 63.0 1F 119.0 fF Ty Construction U-value Or HTM Area (fl0 Load Area (fi� Load number (BWh4(t°F) (Bt hW or perimeter M (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross NIPS Heat Cool Gross N/PS Heat Cool 6 W " 13A-0as 0.143 ne 4.00 2.55 0 0 0 0 0 0 0 0 L-G 1Aalorn 1270 ne 3556 70.43 0 0 0 0 0 0 0 0 13A4= 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 1Aclom 1270 se 35.56 70.95 0 0 0 0 0 0 0 0 11 1100 0.390 m 1092 11.31 0 0 0 0 0 0 0 0 w 13A-4ars 0.143 s 4.00 2.55 0 0 0 0 0 0 0 0 Val 13A4as 0.143 six 4.00 2.55 0 0 0 0 136 130 521 331 ♦-G 1A-clom 1270 w 3556 70.95 0 0 0 0 6 0 213 426 �C 1Ac1om 1270 six 35.56 70.95 0 0 0 0 0 0 0 0 13A4ocs 0.143 nw 4.00 2.55 0 0 0 0 0 0 0 0 lAcl= 1270 nw 3556 4524 0 0 0 0 0 0 0 0 lAclom 1270 my 3556 4524 0 0 0 0 0 0 0 0 4A5-2omd 0.770 hw 21.56 36.90 0 0 0 0 0 0 0 0 P 12C-Ow 0.091 - 2.55 la 0 0 0 0 0 0 0 0 C 16P Wmd 0A32 0.90 2.32 63 63 56 146 119 119 107 276 F 22A-tpl 0989 - 27.69 0.00 63 0 0 0 119 17 471 0 6 c)AED emission -13 55 Eneelope losslgain 56 133 1311 1087 12 a) Infiltration 0 0 265 75 b) Roomvenflauon 0 0 0 0 13 Intemalgaim O=pan6@ 230 0 0 0 0 Appliances(other 0 0 Subtotal(llnes64t 13) 56 133 1577 1162 Leseidamal load 0 0 0 0 Lesistanslar 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 133 1s77 1162 15 DuCloads 1 30% 539/6 17 71 30% 53% 472 618 Total roomn load 73 204 2D49 1780 Airiequired(Qm) 1 1 3 9 93 80 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. ,C- w RigFlSute0llnversa1201919.021 R5U08101 2021-Jan1212A436 Paget ..161wngtsoR WACWYNNE-THE GRAND CARL1ON.np Calc=M18 FrontDoorfaoes:N wrightsoft Right-J®Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST.LUCIE LN,Fr..PFRCE.FL 34946 Phone:772-466-6799 Fax 772466-6796 Email:QUN](GLLCSOWL.COM 1 Room name WCHEN BATH 2 Fvosed xall 0 ft 5.0 ft 3 Room height 8.0 ft heatbod 9.4 ft heaV0001 4 Room dimer> 1.0 x 1920 ft 9.0 x 5.0 ft 5 Roomarea 192D R' 45.0 fF Ty Construction Lkelue Or HTM Area Load number (BbilAIC-9 (Bfuhin or perimeter (ft) (6G1h) or perimeter (2) (Bmh) Heat Cod Gros NIPS Heat Cool Gloss NIPSS Heat Cod 6 13A4ars 0.143 ne 4.00 2.55 0 0 0 0 47 47 188 120 1A-dom 1270 ne 3556 70.43 0 0 -0 0 0- 0 - 0 -6 13AAM 0.143 se 4.00 2.55 0 0 0 0 0 0 0 0 IA-dom 12M se 3556 70.95 0 0 0 0 0 0 0 0 11 11DO 0290 se 1092 11.31 0 0 0 0 0 0 0 0 w 13A-4= 0.143 -s 4A0 2-% 0 0 0 0 0 0 0 0 13AA= 0.143 av 4A0 2.55 0 0 0 0 0 0 0 0 1Ac1om 1270 sw 35M 7095 0 0 0 0 0 0 0 0 1AC1om 1270 sx 35M 70.95 0 0 0 0 0 0 0 0 13A = 0.143 w 400 2M 0 0 : 0 0 0 0 0 - 0 1Ac1om 1270 nw 3556 4624 0 0 - 0 0 0 0 0 0 1Aclom 1270 -mv 35M 4524 - 0- 0 0 0 - 0 0 0 - -0 4A5-2omd 0.770 rw 211% 36.90 0 0 0 0 0 0 0 0 P 12C-Ow OD91 2M 128 0 0 0 0 0 0 0 0 C - 16A3Omd 0.032 - 090 232 192 192 172 445 45 45 40 104 F 22A-fnl 0.989 - 27b9 OAD 192 0 0 0 45 5 138 0 6 c)AEDe=rsion 39 -22 Eneelopelos(gain 172 406 367 202 12 a) Mraton 0 0 92 25 b) Rwmlentlalion 0 0 0 0 13 Internal gains Ooolpants@ 230 0 0 0 0 Applianoes(other 0 0 SubNlal(lines64113) 172 406 459 228 LesseAerralload 0 0 0 0 Leslranskr 0 0 0 0 Redistriblon 0 0 0 0 14 Subtotal 172 406 469 228 15 Dudlwds 30% 53 52 216 30% 53% 137 121 Total roan load 224 622 596 349 Airrepuinxl(dm) 10 28 27 16 Calculations approved byACCAto meet all requirements of Manual J Sth Ed. -rk-wrJoft so 2021Jan1212:0426 �`�c PogitSufe®lhiversa1201919.021 RSU08101 Page ...rts\Wngttsoft FNAC\WYNNE-THEGRANDCARL10Nnq Calc=M18 FrontDoorfao?s N I wrightsofr Right-J@ Worksheet Job: Entire House Date: QUICK CALCS, INC. ay. 317 ST LUGE LN.,Fr.PIERCE,FL 34946 Phone:772-466-6799 Fax772-086-6796 EmeiI:ONCKCALCS@JAOL.COM 1 Roomrame BEDROOM2 ENTRY 2 Elpoxtivall - 302 ft 6D 8 3 Room height 8D ft heaV=l 8.0 ft heaUmol 4 Room Cimensone 1.0 x 1905 ft 6-0x 10.0 ft 5 Raom ales 1905 R 60D i6 Ty Construction U-%due Or HTM Prey Lmd Am number (&hAF-*F7 (BwhR) or penmew (ft) (BWh) a perimeter (8) @tuh) Heat Cool Gros NIPS Heat Cod Gros NAoS Heat Cool 6 VL--f 13AA= _ _ 0.143 ne 4.00 255 120 120 - 480 305 0 0 0 0 IA-M m 1270- ne 35.56. 7OA3 0 0 0 0 0 0 0 0 13AA= 0.143 se 4DD 255 80 60 240 153 48 27 108 69 1Ac1om 1270 se 3555 70.95 20 0 711 1419 0 0 0 0 11 11DO 0290 se 10,92 11.31 0 0 0 0 21 21 229 238 W -13A-4as 0.143 s 4DO 2.55 34 34 136 86 0 0 0 0 y! 13AA= 0.143 sw 4DO 255 8 8 32 20 0 0 0 0 �C 1A-dw 12M sw 3556 70.95 0 0 0 0 0 0 0 0 �G 1Ac1om 1270 w 3556 70.95 00 0 0 0 0 00 13A4= 0.143 nw 4DO 255 0 0 0 0 0 0 0 0 1A-d m 1270 nw 3556 4524 0 0 0 0 - 0 0 0 . 0 1Actom 1270 rnv. 3556 4524 - - 0 - 0 0 0 0 0 0 0 4A5-2omd 0.770 lw 2155 3620 0 0 0 0 0 0 0 0 P 12C41sv OD91 - 255 128 0 0 0 0 0 0 0 0 C 16A30md OD32 0.90 232 191 191 171 442 60 60 54 139 F 22AADI 0.989 - 27.69 0.00 191 30 835 0 60 6 166 0 6 c)AED e=mcn 209 41 Ernelopelossigain 28M 2635 557 Q4 12 a) NfiMation 472 133 94 26 b) Roomven4laton 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoeslother 0 0 Sub�l(lirles6ta 13) 3078 2768 651 43D Lesedemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3078 2768 651 430 15 Duct Wds 3O% 53% 922 1471 30% 53% 195 229 Total mom load 4000 4239 846 659 Airrequired(dm) 181 191 38 30 Calculations aooroved byACCAto meet all requirements of Manual J 8th Ed. .t w "' 20214J 12=436 Acw EGRA uterJlROONInp C lc=M RS1108101 Page4 ..lb1WdglEoft HVAC\WYNNE-THE GRAND CARLIONnp CaIc=MIB FraYDoorfaces:N > wrightsoft` Right-JO Worksheet Job: Entire House Dade: QUICK CALCS, INC. BY 317ST.Ll1CIELN.,Fr.PIERCE,FL34946Phom:772466-6799Fax772-06637M Emait:OUICKCALCS@AOL.COM 1 Rcom rame LAUNDRY GiEAT)DNNG 2 HSQosedHall 6D It 46,0 ft 3 Room height 8.0 ft heatlmol 12D It heatlmW 4 Room dimenaom 7.0 x 6.0 ft 1.0 x 488D ft 5 Room area 42D T 488.0 ft Ty Conftcbm U-%slue or HTM Area Load Arm number (MAr-19 (BIuW or PerimeterM (fth) or perimetetar M Ruh) Heat Cod Gros; NIPS Heat COW Groaa WP5 Heat Cool 6 VL_G- 13A-0aos 0.143 re 4DO 2S5 0 0 0 0 312 274 1098 _ 698 -1Aclom 1270- m 35M 70.43 - 0 0 0 0 38. 0 1344 :' 2662 4 L1344= 0.143 se 4A0 255 0 0 0 0 0 0 0 0 1Actom 1270 m 35M 70-% 0 0 0 0 0 0 0 0 11 11DO 0.390 w 1092 11.31 0 0 0 0 0 0 0 0 W 13AA= Q143 s 4.00 2.55 0 0 0 0 0 0 0 0 4}r 13AA= 0.143 w 4D0 255 48 48 192 122 0 0 0 0 F�—CG 1Actom 1270 w 35.56 70.95 0 0 0 0 0 0 0 0 IAclom 1270 w 35.56 7095 0 0 0 0 0 0 0 0 13A4= 0.143 = 4.00 255 0 0 -0 0 240 199 - 798 507 1Ac1om 1270 rw 3556 4524 0 0- 0 0 0 0 0 0 IA-dw 1270 my 3556 4524 - 0 0 0 0 - - 0 0 0 0 4A5.20md 0.770 rw 2156 36.90 0 0 0 - 0 - 41 0 - 880 -1505 P 12C-0sv O91 - 255 128 0 0 0 0 0 0 0 0 C 16A30md OD32 - 090 2.32 42 42 - 38 97 488 488 437 1132. F 22A4o1 0989 - 2759 ODO 42 6 166 0 488 46 1274 0 6 c)AED—wson -22 -597 Erw1ope losslgain 396 198 1 5830 5908 12 a) Ylfiltration 94 26 1077 304 b) Roomvenblabon 0 0 0 0 13 harrlal gains O=pants@ 230 0 0 0 0 Applimonbther 0 0 SW11ota1(lirw6to13) 490 224 6907 6212 Les;e&malload 0 0 0 0 1-mbarder 0 0 0 0 Red-Woution 0 0 0 0 14 Subbtal 490 224 6907 6212 1s Ductloads 30% 530/6 147 119 30% 53% 2970 3301 Total room load 636 344 8977 9512 Air required(dm) 29 16 407 429 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wrlgtsLsolR� 2021JarF1212:0436 Aft EGRANDCArivarsa1p Calc.=MJB021 F08101 P�5 ...ram\WrigtEoft HVAC\WYNNE-THE GRAND CARLm]NnQ CaIc=MI6 Fror¢Doorfao:s:N wrightsofr Right-J@ Worksheet Job: Entire House Date: QUICK CALM INC. BY 317 ST.LUCIE UN.,Fr.PIERCE.FL 34946 PhGre:772-466-6799 Fax 772466-6796 Emil:QUICKCALCS@AOL.COM 1 Room name BEDROOM3 2 Exposadwall 25.0 It 3 Room height 8.0 It heaV=l 4 Roomdimenslom 15.0 x 10.0 It 5 Room area 150D ft' Ty Construction U-value Or HTM Area (fe) Load Area Load number (BUhA1`---F) (BWh4P) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/PS Heat Cool Gross N/PS Heat Cool 6 U/ 13AAccs 0.143 ne 4.00 2.55 0 0 0 0 L—C 1A- Icon 1270 ne 35.56 70.43 0 0 0 0 13A-4ors 0.143 se 4.00 2.55 0 0 0 0 1Aclom 1270 w 3556 70.95 0 0 0 0 11 LLB--DDD 11D0 0.3N se 10S2 11.31 0 0 0 0 W 13A-0as 0.143 s 4.00 255 0 0 0 0 W, 13AAc s 0.143 w 00 2.55 80 60 240 153 1Aatom 1270 w 3556 70.95 0 0 0 0 1A11orn 1270 sx 35M MIS 20 0 711 1419 V/1 13A4ocs 1270 mw 5.56 524 0 0 0 0 1Xdom 1270 nw 3556 4524 0 0 0 0 4A5-om 1270 nw 2156 36M 0 0 0 0 a7szomd ono nw z15s 3sao 0 0 0 0 P 12C-Ow 0.091 255 128 120 120 306 154 C 16A30md 0.032 - 020 2.32 150 150 134 348 F 22A-tul 0239 27.69 0.00 150 25 692 0 6 c)AEDemwsion 296 Envelopelcs/gatn 2084 2369 12 a) Infiltration 156 44 b) Roomvanfilation 0 0 13 Intemal gars Oaupants@ 230 0 0 Appliances/other 0 SubtDtal(Ilnes6to13) 2240 2413 Les external load 0 0 Lestransfer 0 0 Redistribution 0 0 14 Subtotal 2240 2413 15 Dudloa7s 30% 53% 671 1282 Total room load 2911 3695 Airrequired(Cm) 132 167 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed c Rgkt-SuIB@Unveraa1201919D21 RSU08101 2o21-Jan-1212A4a6 � ...rtslWngt6oft HVACWYNNE-THE GRAND CARLION.np Ca1c=M78 Fror¢Doorfaces:N Page