Loading...
HomeMy WebLinkAboutAPPROVED, Engineering141'-0"135'-5"416'-9"93'-3" 320'-0"635'-0"635'-0"320'-0"NSEW5'-1"8'-10"23'-11"10'-6"SHEET INDEX:A-00: COVER SHEETA-01:SITE PLANS-01:ATTACHMENTSE-01:ELECTRICAL LINE DIAGRAME-02:ELECTRICAL NOTESE-03:WARNING LABELSDS-01+DATA SHEET ROOF ACCESS POINTROOF ACCESS POINT(S) SHALL BE LOCATED IN AREASTHAT DO NOT REQUIRE THE PLACEMENT OF GROUNDLADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORSAND ARE LOCATED AT STRONG LOCATIONS OF BUILDINGCONSTRUCTION THAT DO NOT CONFLICT WITHOBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS.SCALE: NTS2SATELLITE VIEWA-00SCALE: NTS3VICINITY MAPA-00SCALE: 1/32" = 1'1PLOT PLANA-00SYSTEM SIZE: 24.150 kW DC16.800 kW ACMODULE TYPE & AMOUNT:(70) MISSION SOLAR MSE345SX5TMODULE DIMENSIONS:(L/W/H) 68.82"/41.50"/1.58"INVERTER:(70) ENPHASE IQ7-60-2-US [240V])AHJ:ST. LUCIE COUNTYPHOTOVOLTAIC SYSTEM SPECIFICATIONS:PHOTOVOLTAIC ROOF MOUNT SYSTEM70 MODULES-ROOF MOUNTED - 24.150 kW DC, 16.800 kW AC, 2801 S BROCKSMITH RD, FORT PIERCE, FL 34945GOVERNING CODESALL WORK SHALL CONFORM TO THE FOLLOWING CODESa. 2017 NATIONAL ELECTRICAL CODEb. 2020 FL BUILDING CODE - 7TH EDITIONc. 2020 FL BUILDING CODE - 7TH EDITION RESIDENTIALd. FLORIDA FIRE PREVENTION CODEe. ANY OTHER LOCAL AMENDMENTSCOVERSHEETGENERAL NOTES:1.APPLICABLE CODE: 2020 FLORIDA BUILDINGCODE (7TH EDITION) & ASCE 7-16 MINIMUMDESIGN LOADS FOR BUILDING AND OTHERSTRUCTURES.2.LAG SCREW DIAMETER AND EMBEDMENTLENGTHS ARE DESIGNED PER 2020 FLORIDABUILDING CODE (7TH EDITION)REQUIREMENTS. ALL BOLT CAPACITIES AREBASED ON A SOUTHER YELLOW PINE (SYP)RESIDENTIAL WOOD ROOF RAFTERS ASEMBEDMENT MATERIAL.3.ALL WIND DESIGN CRITERIA ANDPARAMETERS ARE FOR HIP AND GABLERESIDENTIAL ROOFS, CONSIDERING FROM A7° TO A MAXIMUM 23° (5/12 TO A MAXIMUM7/12 PITCH) ROOF IN SCHEDULE.CONTRACTOR TO FIELD VERIFY THAT MEANROOF HEIGHT DOES NOT EXCEED 15'-0".4.ROOF SEALANTS SHALL CONFORM TO ASTMC920 AND ASTM 6511, AND IS THERESPONSIBILITY OF THE CONTRACTOR TOPILOT DRILL AND FILL ALL HOLES.5.ALL DISSIMILAR MATERIALS SHALL BESEPARATED WITH NEOPRENE WASHERS,PADS, ETC OR SIMILAR.6.ALL ALUMINIUM COMPONENTS SHALL BEANODIZED ALUMINIUM 6105-T5 UNLESSOTHERWISE NOTED.7.ALL LAG SCREW SHALL BE ASTM A276STAINLESS STEEL UNLESS OTHERWISENOTED.8.ALL SOLAR RAILING AND MODULES SHALLBE INSTALLED PER MANUFACTURERINSTRUCTIONS.9.CONTRACTOR SHALL ENSURE ALL ROOFPENETRATIONS TO BE INSTALLED ANDSEALED PER 2020 FLORIDA BUILDING CODE(7TH EDITION) OR LOCAL GOVERNING CODE.MDRIVEWAYROOF #1(48) MISSION SOLAR MSE345SX5TSLOPE: 26°AZIM.: 180°ROOF #2(22) MISSION SOLAR MSE345SX5TSLOPE: 26°AZIM.: 270°EXISTING INTERIOR LOAD PANEL(INSIDE GARGE)PROPERTY LINEPROPERTY LINEPOOL MAIN HOUSE FRONT OF HOUSE 2801 S BROCKSMITH RD REVGARCIA RESIDENCE 2801 S BROCKSMITH RD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERA-00SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comPROPERTY LINE PROPERTY LINEROOF ACCESS POINTPOOL SYSTEM THIS DIGITAL PDF PLAN SET WAS ELECTRONICALLY SIGNED AND SEALEDBY JOHN ALGER, P.E. ON THE DATE SHOWN USING IDENTRUST. THISCOVER PAGE SEALS ALL SUBSEQUENT PAGES OF THIS PLAN SET.PRINTED COPIES ARE NOT CONSIDERED SIGNED AND SEALED AND ALLSHA-1 AUTHENTICATION CODE MUST BE VERIFIED.MDEXISTING INTERIOR MAINDISCONNECT PANELTIED TO EXTERIOR UTILITYMETER 7'-10"67'-3"7'-10"82'-10"85'-7"20'-7"43'-6"21'-5"NSEW8'-10"23'-11"10'-6"ROOF SECTIONSSCALE: 5/64" = 1'-0"1SITE PLANA-01MODULE, ARRAY WEIGHT(LOAD CALC'S)Number of Modules70Module Weight44.8LBSTotal Module (Array) Weight3136.00LBSNumber of Attachment point167Mounting System Weight(Per Module)1.5LBSMounting System Weight250.50LBSTotal System Weight(Module Weight + Mounting System Weight)3386.50LBSWeight at Each Attachment Point(Array Weight / Number of Attachment Point)18.78LBSModule Area (68.82"x41.50")19.83SqFtTotal Array Area1388.35SqFtDistributed Load(Total System Weight / Total Array Area)2.33Per SqFtTotal Roof Area6077SqFtTotal Percentage or Roof CoveredTotal Array Area / Total Roof Area)*10022.85%SYSTEM LEGENDEXISTING EXTERIOR MAIN DISCONNECT PANELTIED TO EXTERIOR UTILITY METER.NEW DEDICATED PV SYSTEM COMBINER PANEL.MDC70 NEW MISSION SOLAR MSE345SX5T MODULESWITH NEW 70 - ENPHASE IQ7-60-2-US [240V]MICROINVERTERS, MOUNTED ON THE BACK OF EACHMODULES.= CONDUIT RUN= ATTACHMENT POINTS= SEAM= ROOF OBSTRUCTIONS= WIND ZONE 1= RACKING SYSTEM= WIND ZONE 2r, AND 2e= WIND ZONE 3NEW SOLADECK JUNCTION BOX.JBREVGARCIA RESIDENCE 2801 S BROCKSMITH RD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERA-01SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comCIRCUIT(S)SITE PLAN= FIRE PATHWAYDESIGN CRITERIAROOF LIVE LOAD (psf)20GROUND SNOW LOAD (psf)0WIND SPEED (mph)155EXPOSURE CATEGORYBROOF HEIGHT (ft.)12ROOF LENGTH (ft.)86ROOF WIDTH (ft.)83PARAPET HEIGHT (ft.)0DESIGN CALCULATIONWIDTH OF PRESSURE COEFFICIENTROOF LENGTH x 10% (ft.)8.3ROOF HEIGHT x 40% (ft.)4.8ZONE WIDTH "A"4.0'CIRCUIT #5 - 06 MODULESCIRCUIT #4 - 16 MODULESCIRCUIT #3 - 16 MODULESCIRCUIT #2 - 16 MODULESCIRCUIT #1 - 16 MODULESCONTRACTOR IS PERMITTED TO SHIFTAND/OR RELOCATE MODULES TO CLEARROOF TOP OBSTRUCTIONS AND FORIMPROVED PERFORMANCE. FIELDVERIFICATION OF ACTUAL DIMENSIONS ISREQUIRED,GENERAL INSTALLATION PLAN NOTES:1) ROOF ATTACHMENTS SHALL BE INSTALLED ASSHOWN IN SHEET S-01 AND AS FOLLOWS FOR EACHWIND ZONE:WIND ZONE 1 : 4'-0" O.C.WIND ZONE 2r, 2e & 3 : 2'-0" O.C.MODULE RATING IS -78.3 PSF SO IT MAY BEINSTALLED IN ALL ROOF ZONES.THIS PAGE IS PART OF A DIGITAL SEALEDPDF PLAN SET THAT WAS ELECTRONICALLYSIGNED BY JOHN ALGER, P.E. ON THECOVER PAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALEDMODULE - 22SLOPE -26°AZIMUTH -270°MATERIAL -METAL ROOFSEAM SPACING - 24"MODULE - 48SLOPE - 26°AZIMUTH - 180°MATERIAL - METAL ROOFSEAM PACING - 24" .ROOF#01ROOF#02FRONT OF HOUSE 2801 S BROCKSMITH RDZONE 2e IS A 4 FT WIDEZONE ALONG THE EAVEJBZONE 1ZONE 2r IS A 4 FT.ZONE FROM RIDGEDOWN36" FIRE SETBACK4 FT SQUARE CORNERSARE ZONE 3e18" FIRE PATHWAY18" FIRE PATHWAY WIND ZONE 1-38.200WIND ZONE 2e, 2r, AND 3-53.100ROOF #01ROOF #02 POOL PANELS36" FIRE SETBACK 36" FIRE SETBACK36" FIRESETBACK18" FIRE PATHWAY18" FIRE PATHWAY 18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAY18" FIRE PATHWAYMODULE RATING IS -78.3PSF SO IT MAY BE INSTALLEDANYWHERE. THE CLIP IS THE LIMITING FACTORPRESSURES WERE INTERPOLATED FROM THE COMPONENTS ANDCLADDING TABLE FOR HIP ROOF ON P26 OF THE 2020 FBC 7TH EDRESIDENTIAL FOR RISK II EXPOSURE B ENCLOSED STRUCTURESAT 30 FT MEAN ROOF HEIGHT. AN ADJUSTMENT FACTOR OF 1.21WAS USED TO CONVERT TO EXPOSURE C AT MEAN ROOF HEIGHTOF 12 FT.WIND SPEED IS 155MPH, ROOF PITCH IS 26 DEGREES ANDAFFECTED AREA IS 18 SQ FTMACCJBNEW PHOTOVOLTAIC UTILITY DISCONNECT SWITCH.LOCATED WITHIN 10' OF MSP.ACMD18" FIRE PATHWAY18" FIRE PATHWAYEXISTING INTERIOR LOAD PANEL.M PV MODULEIRONRIDGE SUPPORT RAIL(E) STANDING SEAMMETAL ROOFS-5-N MINICLAMPS3/8-24 X .8" ROUNDPOINT SETSCREW(N) IRONRIDGE XR100 RAIL(N) END CLAMP(E) STANDINGSEAM ROOF(N) MID CLAMP24"M8-1.25 X 16MM HEXFLANGE BOLTREVGARCIA RESIDENCE 2801 S BROCKSMITH RD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERS-01SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comMOUNTDETAILTHIS PAGE IS PART OF A DIGITAL SEALEDPDF PLAN SET THAT WAS ELECTRONICALLYSIGNED BY JOHN ALGER, P.E. ON THECOVER PAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED"AS PER THE FBC 107.3.5, I HAVE EVALUATED THE STRUCTURE ANDCERTIFY THAT THE ADDITION OF A SOLAR PV SYSTEM WILL NOTMEASURABLY AFFECT THE STRUCTURAL INTEGRITY OF THE BUILDINGBASED ON THE FOLLOWING:1. UPLIFT FORCES NOTED ARE THE SAME AS ACTING ON AN EXPOSEDPORTION OF THE ROOF. NO ADDITIONAL LOADS ARE ADDED BY ADDINGA SOLAR SYSTEM. ATTACHMENTS ARE INSTALLED INTO THE TRUSSSYSTEM THUS DIRECTING FORCES INTO THE STRUCTURALCOMPONENTS OF THE BUILDING. IN FACT, UPLIFT AFFECTS WILLACTUALLY BE REDUCED SOMEWHAT BY THE PRESENCE OF AN AIR GAPBETWEEN THE ROOF SURFACE AND THE TOP SURFACES OF THE PVMODULES WHICH TENDS TO LOWER THE AVERAGE UPLIFT PRESSURES.2. THE ONLY ADDED LOAD WILL BE THE WEIGHT OF THE PV MODULESAND ATTACHMENT SYSTEM OF RAILS AND FLASHINGS WHICH TYPICALLYIS UNDER 4 PSF. THIS IS AN INSIGNIFICANT ADDITIONAL LOAD TO THESTRUCTURE.SCALE: NTS2ATTACHMENT DETAIL (ENLARGED VIEW)S-01SCALE: NTS1ATTACHMENT DETAIL (SIDE VIEW)S-01 REVGARCIA RESIDENCE 2801 S BROCKSMITH RD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERE-01SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.com120% RULEBUS BAR RATING X 120%) - MAIN BREAKER RATING=MAX. PV OCPD(225A x 120%) - 200A = 70A3-LINEDIAGRAMRooftop conductor ampacities designed in compliancewith art. 690.8, Tables 310.15(B)(2)(a), 310.15(B)(3)(a),310.15(B)(3)(c), 310.15(B)(16), Chapter 9 Table 4, 5, & 9.Location specific temperature obtained from ASHRAE2017 data tablesAMBIENT TEMP (HIGH TEMP 2%)RECORD LOW TEMP0°C33°CCONDUIT HEIGHT0.5"ROOF TOP TEMP55°CCONDUCTOR TEMPERATURE RATE OFF ROOF75°CCONDUCTOR TEMPERATURE RATE ON ROOF90°CENPHASE Q CABLE TO BE ATTACHED TO RAILMIN. 3-1/2" ABOVE ROOF SURFACESYSTEM DATATOTAL MODULES:70TOTAL INVERTERS:70SYSTEM RATINGS:24.150kW DC STCTHIS PAGE IS PART OF A DIGITAL SEALEDPDF PLAN SET THAT WAS ELECTRONICALLYSIGNED BY JOHN ALGER, P.E. ON THECOVER PAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALEDGROUND FROM AC DISCONNECT MUST BE #6 BARE COPPER, JUMPERED TO THENEUTRAL IN DISCONNECT, AND RUN OUTSIDE OF CONDUIT TO THE BAREGROUND WIRE IN LOAD CENTER WHERE IT IS TO BE IRREVERSIBLY CRIMPED.THIS IS TO AVOID PARALLEL GROUNDING OF A LINE SIDE TAP.WIREQTYWIRETAG #CONDUITWIRE TYPEINVERTERQTY:NOC:CONDUITFILL:TEMPRATING:WIREAMPTEMPDE-RATE:WIREOCP:GRNDSIZEGRND WIRETYPEWIREGAUGE:TERMINAL75°C RATING:NEC:STRINGAMPSxx=xx=1.251.016#6SBC20.00A38.40A35A90°35Axx=1.251.016#8THWN-220.00Axx=22.72A90°100Axx=1.251.064#8THWN-280.00Axx=94.00A75°40A#1040A#10100A#31" EMTWIRE FROM - -JUNCTION BOX TO COMBINER PANELCOMBINER PANEL TO ACDARRAY TO JUNCTION BOX123THWN-2THWN-210N/A0.8031.000.960.760.94TRUNKCABLETHWN-28100Axx=1.251.0xx=94.00A75°100A#3ACD TO MAIN DISCONNECT PANEL4THWN-231.000.941-1/4"EMT1-1/4"EMTL1L1L2L216 MICRO-INVERTERS IN BRANCH CIRCUIT #1L2L2L1L116 MICRO-INVERTERS IN BRANCH CIRCUIT #2L2L2L1L116 MICRO-INVERTERS IN BRANCH CIRCUIT #3L2L2L1L116 MICRO-INVERTERS IN BRANCH CIRCUIT #4L1L2NGN20AG20A20A20A(N) COMBINER PANEL ENPHASE IQCOMBINER X-IQ- AM1-240-3 64A/240VCONTINUOUS, PROTECTION MAX80A BREAKER ON SOLAR OUTPUT;WITH 10 KAIC CIRCUIT BREAKERSSOLADECK BOX OR UL 1741APPROVED EQUIVALENTTO TRANSITION FROMQ-CABLE TO THWN-2 WIRENO FUSE REQUIRED(70) ENPHASE IQ7-60-2-US [240V] MICROINVERTERS240VAC,1.0A MAXCEC WEIGHTED EFFICIENCY 97.0%NEMA 4R, UL LISTED, INTERNAL GFDI.GN80A FUSES(N) BLADE TYPEFUSIBLE AC DISCONNECTNEMA 3R 100A-2P 120/240VAC(VISIBLE, LOCKABLE, LABELED)06 MICRO-INVERTERS IN BRANCH CIRCUIT #1L1L1L2L2G10AM*IQ ENVOYGN200AMPOINT OF INTERCONNECT, LINE SIDE TAPEXISTING EXTERIOR MAINDISCONNECT PANEL, SINGLE PHASE,WITH A 200A MAIN DISCONNECTUTILITY METER: FPLSERVICE: UNDERGROUNDLINE SIDETAP4Existing GroundingElectrode SystemTERMINATOR CAP ON LAST CABLECONNECTOR AC TRUNK CABLE (TYP)1#6 BARE COPPER3PRODUCTION CTs3/4" EMT(2x) AWG #12THWN-2 WIREGN(E) LOADS15A/2PEXISTING INTERIOR 240V/225ABUS BAR RATING,LOAD PANEL(E) LOADSEXISTINGWIRES26480.00APOINT OF INTERCONNECT,LOAD BREAKER 1.ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, ANDLABELED FOR ITS APPLICATION.2.ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND90 DEGREE C WET ENVIRONMENT.3.WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPSSHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSEAS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY.4.WORKING CLEARANCES AROUND ALL NEW AND EXISTINGELECTRICAL EQUIPMENT SHALL COMPLY WITH NEC 110.26.5.DRAWINGS INDICATE THE GENERAL ARRANGEMENT OFSYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARYOUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TOFULFILL APPLICABLE CODES AND STANDARDS.6.WHERE SIZES OF JUNCTION BOXES, RACEWAYS, ANDCONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALLSIZE THEM ACCORDINGLY.7.ALL WIRE TERMINATIONS SHALL BE APPROPRIATELYLABELED AND READILY VISIBLE.8.MODULE GROUNDING CLIPS TO BE INSTALLED BETWEENMODULE FRAME AND MODULE SUPPORT RAIL, PER THEGROUNDING CLIP MANUFACTURER'S INSTRUCTION.9.MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUSCOPPER G.E.C. VIA WEEB LUG OR ILSCO GBL-4DBT LAY-INLUG.10.UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALLPHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THESERVICE ENTRANCE.11.WORKING CLEARANCES AROUND THE EXISTING AND NEWELECTRICAL EQUIPMENT WILL BE MAINTAINED INACCORDANCE WITH NEC ARTICLE 110.26.12.ALL EQUIPMENT INSTALLED SHALL BE LISTED BY ANATIONALLY RECOGNIZED TESTING LABORATORY (NRTL)PER NEC ARTICLE 110.3.13.RACKING CONFORMS TO AND IS LISTED UNDER UL 2703.14.ALL LABELS OR MARKINGS SHALL BE VISIBLE AFTERINSTALLATION. THE LABELS SHALL BE REFLECTIVE, AND ALLLETTERS SHALL BE CAPITALIZED AND SHALL BE A MINIMUMHEIGHT OF 9.5 MM (3/8 IN) IN WHITE ON A RED BACKGROUND.15.CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED ASSUNLIGHT RESISTANT PER NEC ARTICLE 300.6 (C) (1) ANDARTICLE 310.8 (D).16.CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BESUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE310.8 (C).REVGARCIA RESIDENCE 2801 S BROCKSMITH RD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERE-02SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comSYSTEM NOTES:1.ENPHASE IQ7 / 7PLUS MICROINVERTERS DO NOT REQUIREGROUNDING ELECTRODE CONDUCTORS OR EQUIPMENTGROUNDING CONDUCTORS. THE MICROINVERTERS ITSELF HASCLASS II DOUBLE-INSULATED RATING, WHICH INCLUDES GROUNDFAULT PROTECTION.2.ENPHASE Q CABLE HAS NO NEUTRAL WIRE - (2 WIRE DOUBLEINSULATED CABLING)3.MODULES ARE BONDED TO RAIL USING UNIRAC INTEGRATEDGROUNDING.4.RAILS ARE BONDED WITH UL 2703 RATED LAY-IN LUGS5.SYSTEM IS UNGROUNDED6.BARE COPPER IS TRANSITIONED TO THHN/THWN-2 VIAIRREVERSIBLE CRIMP; GEC TO BE CONTINUOUS PER CEC250.64(C)7.SUB-BRANCHES ARE CENTER-FED AT JBOX TO MAKE ONE TOTALBRANCH CIRCUIT.8.ENPHASE IQ ENVOY INSIDE IQ COMBINER REQUIRES A NEUTRALTO BE LANDED AT THE NEUTRAL BUSS AT MAIN PANEL PERENPHASE INSTALLATION INSTRUCTIONS.9.ENPHASE MICROINVERTERS ARE ALL RAPID SHUTDOWN READYPER NEC 690.12PV MODULE RATING @ STCMANUFACTURERMAX. POWER-POINT CURRENT (IMP)MAX. POWER-POINT VOLTAGE (VMP)OPEN-CIRCUIT VOLTAGE (VOC)SHORT-CIRCUIT CURRENT (ISC)10.34 AMPS33.37 VOLTS41.00 VOLTS10.92 AMPSNOM. MAX. POWER AT STC (PMAX)MAX. SYSTEM VOLTAGEVOC TEMPERATURE COEFFICIENT345 WATT1000 VDC-0.262° %/°CMISSION SOLAR MSE345SX5TELECTRICAL NOTES:ELECTRICALNOTESPHOTOVOLTIAC AC OUTPUTAC OUTPUT CURRENTNOMINAL AC VOLTAGE240V70.00ALABLESRATED MPP CURRENTRATED MPP VOLTAGE33.37 V10.34 APHOTOVOLTAIC DC PER INVERTERMAX SYSTEM VOLTAGESHORT CIRCUIT CURRENT41.00 V10.92 VSYSTEM DATA# STRINGS:05SMALLEST STRING:06LARGEST STRING:16TOTAL MODULES:70TOTAL INVERTERS:70SYSTEM RATINGS:24.150kW DC STCBATTERY RATING:N/AINVERTER SPECIFICATIONSMANUFACTURERMAX. POWER AT 40 C48 VOLTSNOMINAL AC VOLTAGE240 WATTSMAX. AC CURRENT240 VOLTSMAX. OCPD RATINGMAX. PANELS/CIRCUITSHORT CIRCUIT CURRENT1.0 AMPS20 AMPSMAX. DC VOLT RATING1615 AMPSENPHASE ENERGY IQ7-60-2-USCERTIFICATE OFAUTHORIZATION#31930ENGINEER OF RECORDJOHN L. ALGERPROFESSIONAL ENGINEERFL. LICENSE NO. 74730 I JOHN L ALGER, PE# 74730, ANENGINEER PURSUANT TOCHAPTER 471 OF THE FLORIDASTATUTES, HERE BY STATE THATI HAVE EVALUATED ALL OF THECOMPONENTS AND THE SYSTEMAS A WHOLE AND CERTIFY THATIT MEETS OR EXCEEDS THEREQUIREMENTS OF:2020 FBC 7TH ED, 2020 FBC 7THED RESIDENTIAL & 2017 NECTHIS PAGE IS PART OF A DIGITAL SEALEDPDF PLAN SET THAT WAS ELECTRONICALLYSIGNED BY JOHN ALGER, P.E. ON THECOVER PAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED INVERTER OUTPUT CONNECTIONPHOTOVOLTAIC SYSTEMCOMBINER PANELNOTES AND SPECIFICATIONS:·SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE NEC 2017ARTICLE 110.21(B), UNLESS SPECIFIC INSTRUCTIONS ARE REQUIREDBY SECTION 690, OR IF REQUESTED BY THE LOCAL AHJ.·SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS USINGEFFECTIVE WORDS, COLORS AND SYMBOLS.·LABELS SHALL BE PERMANENTLY AFFIXED TO THE EQUIPMENT ORWIRING METHOD AND SHALL NOT BE HAND WRITTEN.·LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THEENVIRONMENT INVOLVED.·SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, PRODUCTSAFETY SIGNS AND LABELS, UNLESS OTHERWISE SPECIFIED.·DO NOT COVER EXISTING MANUFACTURER LABELS.WARNING!SOURCES: UTILITY GRIDAND PV SOLAR ELECTRICSYSTEMDUAL POWER SUPPLYLABEL LOCATION:UTILITY SERVICE METER AND MAIN SERVICEPANEL.PER CODE(S): NEC 2017: 705.12(D)(3), NEC 2011: 705.12(D)(4)ELECTRICAL SHOCK HAZARDDO NOT TOUCH TERMINALS.TERMINALS ON LINE AND LOADSIDES MAY BE ENERGIZED INTHE OPEN POSITIONWARNING!LABEL LOCATION:INVERTER(S), AC DISCONNECT(S), ACCOMBINER PANEL (IF APPLICABLE).PER CODE(S): CEC 2019: 690.17(B),NEC 2017: 690.17(E), NEC 2011: 690.17(4)WARNING!DO NOT RELOCATE THISOVERCURRENT DEVICELABEL LOCATION:ADJACENT TO PV BREAKER (IF APPLICABLE).PER CODE(S): CEC 2019: 705.12(B),NEC 2017: 705.12(D)(2)(3)(b), NEC 2011: 705.12(D)(7)!DO NOT ADD LOADSWARNINGLABEL LOCATION:PHOTOVOLTAIC AC COMBINER (IF APPLICABLE).PER CODE(S): CEC 2016: 705.12(D)(2)(3)(c), NEC2017: 705.12(D)(2)(3)(c), NEC 2011: 705.12(D)(4)WARNING: PHOTOVOLTAICPOWER SOURCEWARNING: PHOTOVOLTAICPOWER SOURCELABEL LOCATION:INTERIOR AND EXTERIOR DC CONDUIT EVERY 1O FT, AT EACHTURN, ABOVE AND BELOW PENETRATIONS, ON EVERY JB/PULLBOX CONTAINING DC CIRCUITS.PER CODE(S): CEC 2019: 690.13, NEC 2017: 690.31(G)(3),690.31(G)(4), NEC 2011: 690.31(E)(3), 690.31(E)(4), IFC 2012:605.11.1.4LABEL LOCATION:AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OFINTERCONNECTION.PER CODE(S): CEC 2019: 690.53, NEC 2017: 690.54, NEC 2011: 690.54MAXIMUM AC OPERATING CURRENT:NOMINAL OPERATING AC VOLTAGE: 70.00 AMPS 240 VACPHOTOVOLTAIC AC DISCONNECTASOLAR PV SYSTEMEQUIPPED WITH RAPIDSHUTDOWNTURN RAPIDSHUTDOWNSWITCH TO THE"OFF" POSITION TOSHUTDOWN PVSYSTEM ANDREDUCESHOCK HAZARDIN THE ARRAYSOLARELECTRICPV PANELSREVGARCIA RESIDENCE 2801 S BROCKSMITH RD, FORT PIERCE, FL 34945 DATEDESCRIPTIONREVISIONSSHEET SIZEANSI B11" x 17"SHEET NUMBERE-03SHEET NAMEPROJECT NAMESIGNATURE WITH SEAL650 2ND LANEVERO BEACH, FL 32962, USAPHONE: 772-567-3104FAX: (772)567-4553Website: www.climatocsolar.comWARNINGLABELSTHIS PAGE IS PART OF A DIGITAL SEALEDPDF PLAN SET THAT WAS ELECTRONICALLYSIGNED BY JOHN ALGER, P.E. ON THECOVER PAGE. PRINTED COPIES ARE NOTCONSIDERED SIGNED AND SEALED