Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PROJECT INFORMATION
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 1 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Load Short Form 4/27/2021Date:Zone 1 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX16S181A AHRI ref Coil ASPT25B14A AHRI ref 201786256 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW3.3 Sensible cooling Btuh12600 Heating output Btuh11234 Latent cooling Btuh5400 Temperature rise °F17 Total cooling Btuh18000 Actual air flow cfm600 Actual air flow cfm600 Air flow factor cfm/Btuh0.050 Air flow factor cfm/Btuh0.056 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.73 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Master Bed 2 293 4351 2961 218 166 M Bath 2 85 808 470 40 26 Bath 2 51 996 490 50 28 Clst 86 449 439 22 25 Hall 82 0 0 0 0 3 121 2675 2698 134 152 Bed 3 162 2653 2818 133 158 Hall 2 81 0 0 0 0 Laundry 25 50 803 3 45 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 2 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N Zone 1 984 11982 10678 600 600 Other equip loads 1658 880 Equip. @ 0.95 RSM 11027 Latent cooling 4253 TOTALS 984 13640 15280 600 600 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 3 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Load Short Form 4/27/2021Date:Zone 2 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 Design Information InfiltrationClgHtg SimplifiedMethod9041Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1529Design TD (°F) L-Daily range 5030Inside humidity (%) 572Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Make Goodman Mfg. Trade Trade GOODMAN Model Cond GSX160301F AHRI ref Coil ASPT37C14A AHRI ref 201384656 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW4.8 Sensible cooling Btuh19600 Heating output Btuh16341 Latent cooling Btuh8400 Temperature rise °F16 Total cooling Btuh28000 Actual air flow cfm933 Actual air flow cfm933 Air flow factor cfm/Btuh0.053 Air flow factor cfm/Btuh0.050 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 0.78 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) KitFoyer 270 3881 4932 205 246 Living Dining 371 5528 8648 292 431 His 65 1538 574 81 29 Master Bed 273 4769 3573 252 178 M Bath 72 1929 1017 102 51 Zone 2 1051 17644 18744 933 933 Other equip loads 1961 1041 Equip. @ 0.95 RSM 18875 Latent cooling 5607 TOTALS 1051 19605 24483 933 933 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 1 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Building Analysis 4/27/2021Date:Zone 1 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Other Ceilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 20.327713.1Walls 7.4101516.6Glazing 0.5663.7Doors 7.29751.0Ceilings 21.329113.03.0Floors 11.015012.0Infiltration 20.12742Ducts 00Piping 00Humidification 12.21658Ventilation0Adjustments 100.013640Total Cooling Walls Glazing Other Ceilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 14.516741.9Walls 14.3165127.0Glazing 0.6673.7Doors 15.417761.8Ceilings 000Floors 3.43990.5Infiltration 27.33153Ducts 7.6880Ventilation 17.01960Internal gains 00Blower 0Adjustments 100.011559Total Latent Cooling Load = 4253 Btuh Overall U-value = 0.091 Btuh/ft²-°F Data entries checked. 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 2 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Building Analysis 4/27/2021Date:Zone 2 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 Design Conditions Location: CoolingHeatingIndoor:7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing OtherCeilings Floors Infiltration Ducts Ventilation % of loadBtuhBtuh/ft²Component 15.329903.1Walls 21.1413318.5Glazing 0.5893.7Doors 5.310421.0Ceilings 18.836863.53.5Floors 9.217952.0Infiltration 19.93910Ducts 00Piping 00Humidification 10.01961Ventilation0Adjustments 100.019605Total Cooling Walls Glazing OtherCeilings Infiltration Ducts Internal Gains Ventilation % of loadBtuhBtuh/ft²Component 9.017721.8Walls 30.6605427.1Glazing 0.5893.7Doors 9.618961.8Ceilings 000Floors 2.44770.5Infiltration 22.44436Ducts 5.31041Ventilation 20.34020Internal gains 00Blower 0Adjustments 100.019785Total Latent Cooling Load = 5607 Btuh Overall U-value = 0.124 Btuh/ft²-°F Data entries checked. 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 1 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Component Constructions 4/27/2021Date:Zone 2 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk Wall, Stucco Ext, R-4.1 Ext Bd inI, 8" Thk, 1/2" Gyp Bd Int Fnsh 1013.155.10.10932n 642.02 3262.025103.155.10.109162e 3942.026153.155.10.109195s 4992.027803.155.10.109248w 12842.0220073.155.10.109637all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 4881.469832.9411.00.101335 Windows Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.92 ft window ht, 1 ft sep.); 8 ft head ht 49928.129916.800.58018w Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 4 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht 57712.090518.800.65048n Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); foreground = green grass (0.23); 1 ft overhang (5.2 ft window ht, 1 ft sep.); 8 ft head ht 17734.08716.800.5805e Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.22); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 5.4 ft overhang (4.17 ft window ht, 1 ft sep.); 8 ft head ht 28816.032518.000.62018e Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (2.08 ft window ht, 1 ft sep.); 8 ft head ht 17628.110516.800.5806w Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.21); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 8 ft overhang (8 ft window ht, 1 ft sep.); 8 ft head ht 227817.8241318.800.650128w 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 2 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N Doors Fbrgls Door 893.73893.697.00.12724e Ceilings Attic, Shngl Roof, R-30 Ceil Ins, 1/2" Gyp Bd Int Fnsh 0.0341051 18961.8010420.9930.0 Floors On Grade Depth, Tile Flr Fnsh 00368628.700.989129 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 3 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Component Constructions 4/27/2021Date:Zone 1 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 Design Conditions Location: CoolingHeatingIndoor: 7570Indoor temperature (°F)St Lucie Co Intl, FL, US 1529Design TD (°F)ft26Elevation: 5030Relative humidity (%)°N28Latitude: Outdoor:56.92.4Moisture difference (gr/lb)CoolingHeating Infiltration:9041Dry bulb (°F) SimplifiedMethod)L(15-Daily range (°F) AverageConstruction quality77-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLoss Clg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls Blk Wall, Stucco Ext, R-4.1 Ext Bd inI, 8" Thk, 1/2" Gyp Bd Int Fnsh 11533.155.10.109366n 7382.02 102.02163.155.10.1095e 2052.023203.155.10.109102s 3782.025913.155.10.109188w 13312.0220803.155.10.109660all Partitions Frm Wall, 1/2" Gyp Bd Ext, R-11 Cav Ins, 1/2" Gyp Bd Int Fnsh, 2"x4", 16" OC Stud 3431.466902.9411.00.101235 Windows Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.18); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (1.33 ft window ht, 1 ft sep.); 8 ft head ht 358.825213.000.4504n Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (2 ft window ht, 1 ft sep.); 8 ft head ht 4611.56716.800.5804n Impact, Clear Low-e: Impact, Clear Low-e; NFRC rated (SHGC=0.24); 50% blinds 45°, medium; 50% outdoor insect screen; foreground = green grass (0.23); 1 ft overhang (5.92 ft window ht, 1 ft sep.); 8 ft head ht 20411.529916.800.58018n 99928.159716.800.58036w 120222.689616.800.58053all Doors Fbrgls Door 673.73663.697.00.12718s Ceilings Attic, Shngl Roof, R-30 Ceil Ins, 1/2" Gyp Bd Int Fnsh 0.034984 17761.809750.9930.0 Floors On Grade Depth, Tile Flr Fnsh 00291128.700.989102 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 1 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Project Summary 4/27/2021Date:Zone 1 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor:2207 River Hammock Ln, Fort Pierce, FL 34981 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh9239 Structure Btuh7525 Ducts Btuh2742 Ducts Btuh3153Central vent (52 cfm) 1658 Btuh Central vent (52 cfm) Btuh880 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh13640 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh11027 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh1310 Ducts Btuh933Central vent (52 cfm) Btuh2010 CoolingHeating Outside air984984Area (ft²) Equipment latent load Btuh4253 94309430Volume (ft³)Air changes/hour 0.150.30 Equipment Total Load (Sen+Lat)Btuh15280 Equiv. AVF (cfm) 2447 Req. total capacity at 0.70 SHR ton1.3 Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg.Trade Trade GOODMAN Model Cond GSX16S181AAHRI ref Coil ASPT25B14A AHRI ref 201786256Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW3.3 Sensible cooling Btuh12600Heating output Btuh11234 Latent cooling Btuh5400 Temperature rise Total coolingActual air flow Actual air flow Air flow factor Air flow factorStatic pressure Static pressure Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 2 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Project Summary 4/27/2021Date:Zone 2 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor:2207 River Hammock Ln, Fort Pierce, FL 34981 Notes: Design Information St Lucie Co Intl, FL, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F41 Outside db °F90Inside db °F70 Inside db °F75 Design TD °F29 Design TD °F15Daily range L Relative humidity %50Moisture difference gr/lb57 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh13734 Structure Btuh14308 Ducts Btuh3910 Ducts Btuh4436Central vent (62 cfm) 1961 Btuh Central vent (62 cfm) Btuh1041 Outside air Outside airHumidification Btuh0 Blower Btuh0 Piping Btuh0Equipment load Btuh19605 Use manufacturer's data n Rate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh18875 Method Latent Cooling Equipment Load SizingSimplified Construction quality Average0Fireplaces Structure Btuh1888 Ducts Btuh1342Central vent (62 cfm) Btuh2377 CoolingHeating Outside air10511051Area (ft²) Equipment latent load Btuh5607 99639963Volume (ft³)Air changes/hour 0.170.34 Equipment Total Load (Sen+Lat)Btuh24483 Equiv. AVF (cfm) 2856 Req. total capacity at 0.70 SHR ton2.2 Heating Equipment Summary Cooling Equipment Summary Make Make Goodman Mfg.Trade Trade GOODMAN Model Cond GSX160301FAHRI ref Coil ASPT37C14A AHRI ref 201384656Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input kW4.8 Sensible cooling Btuh19600Heating output Btuh16341 Latent cooling Btuh8400 Temperature rise Total coolingActual air flow Actual air flow Air flow factor Air flow factorStatic pressure Static pressure Space thermostat Load sensible heat ratio Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49Right-Suite® Universal 2021 21.0.06 RSU29066 Page 1...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Right-J® Worksheet 4/27/2021Date:Zone 1 Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Zone 1 Master Bed 2 2 Exposed wall 101.5 ft 34.5 ft 3 Room height 9.6 ft 10.0 heat/coolft 4 Room dimensions ft15.0x19.5 5 Room area 984.0 ft²292.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 392 366 1153 738 150 132 417 267 .GG Impact, Clear Low-e 0.450Impact, Clear Low-e 0.450 nn 13.0513.05 8.828.82 4 0 52 35 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 4 0 67 46 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 18 0 299 204 18 0 299 204 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 5 5 16 10 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 119 102 320 205 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 18 18 66 67 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 223 188 591 378 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 36 0 597 999 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 235 235 690 343 195 195 573 284 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 984 984 975 1776 293 293 290 528 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 984 102 2911 0 293 35 989 0 6 c) AED excursion 367 -16 Envelope loss/gain 7738 5167 2568 1266 12 a) Infiltration 1501 399 305 81 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 1500 500 Subtotal (lines 6 to 13)9239 7525 2872 1847 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 483 240 14 Subtotal 9239 7525 3355 2087 15 Duct loads 30%42%2742 3153 30%42%996 874 Total room load 11982 10678 4351 2961 Air required (cfm)Air required (cfm)600 600 218 166 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49Right-Suite® Universal 2021 21.0.06 RSU29066 Page 2...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Right-J® Worksheet 4/27/2021Date:Zone 1 Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name M Bath 2 Bath 2 2 Exposed wall 6.5 ft 8.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft6.5x13.0 ft8.5x6.0 5 Room area 84.5 ft²51.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 60 56 178 114 79 75 236 151 .GG Impact, Clear Low-e 0.450Impact, Clear Low-e 0.450 nn 13.0513.05 8.828.82 4 0 52 35 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 0 0 0 0 4 0 67 46 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 85 85 84 152 51 51 51 92 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 85 7 186 0 51 9 244 0 6 c) AED excursion -3 -3 Envelope loss/gain 500 299 598 286 12 a) Infiltration 123 33 160 43 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)623 331 759 329 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 9 17 14 Subtotal 623 331 768 345 15 Duct loads 30%42%185 139 30%42%228 145 Total room load 808 470 996 490 Air required (cfm)Air required (cfm)40 26 50 28 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49Right-Suite® Universal 2021 21.0.06 RSU29066 Page 3...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Right-J® Worksheet 4/27/2021Date:Zone 1 Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Clst Hall 2 Exposed wall 0 ft 0 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft85.5x1.0 ft82.3x1.0 5 Room area 85.5 ft²82.3 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.450Impact, Clear Low-e 0.450 nn 13.0513.05 8.828.82 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 86 86 85 154 82 82 82 148 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 86 0 0 0 82 0 0 0 6 c) AED excursion -1 -1 Envelope loss/gain 85 153 82 147 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)85 153 82 147 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 262 156 -82 -147 14 Subtotal 346 309 0 0 15 Duct loads 30%42%103 130 30%42%0 0 Total room load 449 439 0 0 Air required (cfm)Air required (cfm)22 25 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49Right-Suite® Universal 2021 21.0.06 RSU29066 Page 4...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Right-J® Worksheet 4/27/2021Date:Zone 1 Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name 3 Bed 3 2 Exposed wall 22.0 ft 21.0 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft11.0x11.0 ft161.8x1.0 5 Room area 121.0 ft²161.8 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 102 102 322 206 0 0 0 0 .GG Impact, Clear Low-e 0.450Impact, Clear Low-e 0.450 nn 13.0513.05 8.828.82 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 74 74 234 150 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 102 85 266 170 121 103 325 208 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 18 0 299 499 18 0 299 499 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 0 0 0 0 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 121 121 120 218 162 162 160 292 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 121 22 631 0 162 21 602 0 6 c) AED excursion 200 200 Envelope loss/gain 1638 1295 1621 1349 12 a) Infiltration 415 110 396 105 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 1 230 1 230 Appliances/other 250 250 Subtotal (lines 6 to 13)2054 1885 2017 1934 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 9 17 28 51 14 Subtotal 2063 1902 2046 1986 15 Duct loads 30%42%612 797 30%42%607 832 Total room load 2675 2698 2653 2818 Air required (cfm)Air required (cfm)134 152 133 158 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49Right-Suite® Universal 2021 21.0.06 RSU29066 Page 5...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Right-J® Worksheet 4/27/2021Date:Zone 1 Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Hall 2 Laundry 2 Exposed wall 9.0 ft 0 ft 3 Room height 10.0 heat/coolft 10.0 heat/coolft 4 Room dimensions ft18.0x4.5 ft3.5x7.0 5 Room area 81.0 ft²24.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.450Impact, Clear Low-e 0.450 nn 13.0513.05 8.828.82 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 16.8216.82 11.4811.48 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 5 5 16 10 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 45 27 85 55 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 3.693.69 3.733.73 18 18 66 67 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 0.000.00 0.000.00 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 40 40 118 58 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 81 81 80 146 25 25 24 44 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 81 9 258 0 25 0 0 0 6 c) AED excursion -3 -5 Envelope loss/gain 623 333 24 39 12 a) Infiltration 102 27 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 0 500 Subtotal (lines 6 to 13)725 360 24 539 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution -725 -360 15 26 14 Subtotal 0 0 39 566 15 Duct loads 30%42%0 0 30%42%12 237 Total room load 0 0 50 803 Air required (cfm)Air required (cfm)0 0 3 45 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49Right-Suite® Universal 2021 21.0.06 RSU29066 Page 6...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Right-J® Worksheet 4/27/2021Date:Zone 2 Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Zone 2 KitFoyer 2 Exposed wall 128.5 ft 34.5 ft 3 Room height 9.5 ft 9.3 heat/coolft 4 Room dimensions ft12.0x22.5 5 Room area 1050.8 ft²270.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 80 32 101 64 0 0 0 0 .GG Impact, Clear Low-e 0.450Impact, Clear Low-e 0.450 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 12.0212.02 48 0 905 577 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 209 162 510 326 209 162 510 326 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 33.9933.99 5 0 87 177 5 0 87 177 GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 15.9515.95 18 15 325 288 18 15 325 288 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 24 24 89 89 24 24 89 89 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 195 195 615 394 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 400 248 780 499 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 6 0 105 176 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 18 0 299 499 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 17.8017.80 128 90 2413 2278 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 335 335 983 488 112 112 328 163 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 1051 1051 1042 1896 270 270 268 487 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 1051 129 3686 0 270 35 989 0 6 c) AED excursion 2059 -39 Envelope loss/gain 11939 9812 2596 1492 12 a) Infiltration 1795 477 425 113 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 4 920 2 460 Appliances/other 3100 1700 Subtotal (lines 6 to 13)13734 14308 3021 3765 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 13734 14308 3021 3765 15 Duct loads 28%31%3910 4436 28%31%860 1167 Total room load 17644 18744 3881 4932 Air required (cfm)Air required (cfm)933 933 205 246 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49Right-Suite® Universal 2021 21.0.06 RSU29066 Page 7...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Right-J® Worksheet 4/27/2021Date:Zone 2 Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Living Dining His 2 Exposed wall 26.0 ft 16.5 ft 3 Room height 9.3 heat/coolft 9.3 heat/coolft 4 Room dimensions ft16.5x22.5 ft10.0x6.5 5 Room area 371.3 ft²65.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.450Impact, Clear Low-e 0.450 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 12.0212.02 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 33.9933.99 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 15.9515.95 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 93 93 293 187 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 209 81 256 164 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 17.8017.80 128 90 2413 2278 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 33 33 96 47 60 60 178 88 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 371 371 368 670 65 65 64 117 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 371 26 746 0 65 17 473 0 6 c) AED excursion 1969 -5 Envelope loss/gain 3878 5128 1008 388 12 a) Infiltration 425 113 189 50 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 2 460 0 0 Appliances/other 900 0 Subtotal (lines 6 to 13)4303 6601 1197 439 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 4303 6601 1197 439 15 Duct loads 28%31%1225 2046 28%31%341 136 Total room load 5528 8648 1538 574 Air required (cfm)Air required (cfm)292 431 81 29 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Apr-27 14:43:49Right-Suite® Universal 2021 21.0.06 RSU29066 Page 8...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Right-J® Worksheet 4/27/2021Date:Zone 2 Chris BatemanBy:Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com 1 Room name Master Bed M Bath 2 Exposed wall 34.0 ft 17.5 ft 3 Room height 10.0 heat/coolft 9.3 heat/coolft 4 Room dimensions ft21.0x13.0 ft11.0x6.5 5 Room area 273.0 ft²71.5 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft) (Btuh)or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 nn 3.153.15 2.022.02 80 32 101 64 0 0 0 0 .GG Impact, Clear Low-e 0.450Impact, Clear Low-e 0.450 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 .GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 nn 0.000.00 0.000.00 0 0 0 0 0 0 0 0 11 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 nn 18.8518.85 12.0212.02 48 0 905 577 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ee 3.153.15 2.022.02 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ee 16.8216.82 33.9933.99 0 0 0 0 0 0 0 0 GG Impact, Clear Low-e 0.620Impact, Clear Low-e 0.620 ee 17.9817.98 15.9515.95 0 0 0 0 0 0 0 0 DD Fbrgls DoorFbrgls Door 0.1270.127 ee 3.693.69 3.733.73 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ss 3.153.15 2.022.02 0 0 0 0 102 102 322 206 DD Fbrgls DoorFbrgls Door 0.1270.127 ss 0.000.00 0.000.00 0 0 0 0 0 0 0 0 WW Blk Wall, Stucco Ext 0.109Blk Wall, Stucco Ext 0.109 ww 3.153.15 2.022.02 130 112 354 226 60 54 171 109 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 0 0 0 0 6 0 105 176 GG Impact, Clear Low-e 0.580Impact, Clear Low-e 0.580 ww 16.8216.82 28.1328.13 18 0 299 499 0 0 0 0 GG Impact, Clear Low-e 0.650Impact, Clear Low-e 0.650 ww 18.8518.85 17.8017.80 0 0 0 0 0 0 0 0 PP Frm Wall, 1/2" Gyp B 0.101Frm Wall, 1/2" Gyp B 0.101 --2.942.94 1.461.46 130 130 382 190 0 0 0 0 CC Attic, Shngl Roof, R 0.034Attic, Shngl Roof, R 0.034 --0.990.99 1.801.80 273 273 271 493 72 72 71 129 FF On Grade Depth, Tile 0.989On Grade Depth, Tile 0.989 --28.6828.68 0.000.00 273 34 975 0 72 18 502 0 6 c) AED excursion 65 69 Envelope loss/gain 3286 2114 1171 689 12 a) Infiltration 426 113 330 88 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230230 0 0 0 0 Appliances/other 500 0 Subtotal (lines 6 to 13)3712 2727 1501 777 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0 RedistributionRedistribution 0 0 0 0 14 Subtotal 3712 2727 1501 777 15 Duct loads 28%31%1057 845 28%31%427 241 Total room load 4769 3573 1929 1017 Air required (cfm)Air required (cfm)252 178 102 51 2021-Apr-27 14:43:50 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 1 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Duct System Summary 4/27/2021Date:Zone 1 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.355 / 0.345 in H2O in H2O0.355 / 0.345 Lowest friction rate in/100ft0.211in/100ft0.211 Actual air flow cfm600cfm600 Total effective length (TEL) ft331 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st4125.037.9VlFx0x08.00.2181821612698c3 st4125.036.6VlFx0x05.00.2203360996hBath 2 st4125.043.2VlFx0x08.00.2111901592818cBed 3 st1100.025.4VlFx0x04.00.2833027439cClst st4125.035.5VlFx0x04.00.221543803cLaundry st1100.023.8VlFx0x04.00.2873249808hM Bath 2 st1100.022.9VlFx0x06.00.2891001312175hMaster Bed 2-A st1100.023.9VlFx0x06.00.2871001312175hMaster Bed 2-B Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st4 Peak AVF 383 459 0.211 585 12.0 0x0 VinlFlx st1 st1 Peak AVF 720 720 0.211 674 14.0 0x0 VinlFlx 2021-Apr-27 14:43:50 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 2 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rb13 0x 1610 182 96.9 0.356 521 8.0 x0 0 VlFx rt1 rb12 0x 1590 190 97.5 0.354 544 8.0 x0 0 VlFx rt1 rb16 0x 2880 229 38.0 0.907 529 10.0 x0 0 VlFx rb7 0x 1110 119 163.1 0.211 445 7.0 x0 0 VlFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 432 491 0.211 459 14.0 0x0 VinlFlx 2021-Apr-27 14:43:50 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 3 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Duct System Summary 4/27/2021Date:Zone 2 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0in H2O0 Available static pressure in H2O0.70in H2O0.70 Supply / return available pressure 0.350 / 0.350 in H2O in H2O0.350 / 0.350 Lowest friction rate in/100ft0.573in/100ft0.573 Actual air flow cfm933cfm933 Total effective length (TEL) ft122 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm) (cfm)FR (in)(in)Matl Ln (ft)Ln (ft) Trunk st3100.019.4VlFx0x05.00.58634981538hHis st2100.021.5VlFx0x06.00.5761471232466cKitFoyer st2100.019.9VlFx0x06.00.5841471232466cKitFoyer-A st2100.020.1VlFx0x08.00.5832581754324cLiving Dining st2100.022.2VlFx0x08.00.5732581754324cLiving Dining-A st3100.020.6VlFx0x06.00.580611221929hM Bath st3100.020.8VlFx0x06.00.5801071512384hMaster Bed st3100.017.3VlFx0x06.00.5971071512384hMaster Bed-A Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st3 Peak AVF 523 309 0.580 666 12.0 0x0 VinlFlx st2 Peak AVF 597 811 0.573 759 14.0 0x0 VinlFlx Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in) Matl Trunk rsb5 0x 7200 872 0 0 0 0 x0 0 VlFx rb2 0x 4000 248 0 0 0 0 x0 0 VlFx 2021-Apr-27 14:43:50 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 1 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Manual S Compliance Report 4/27/2021Date:Zone 1 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 Cooling Equipment Design Conditions °F77.5Entering coil DB:Btuh11559Sensible gain:°F90.4Outdoor design DB: °F64.7Entering coil WB:Btuh4253Latent gain:°F77.4Outdoor design WB: Btuh15812Total gain:°F75.0Indoor design DB: cfm600Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: GSX16S181A+ASPT25B14AModel:Goodman Mfg.Manufacturer: cfm600Actual airflow: % of load109Btuh12600Sensible capacity: % of load127Btuh5400Latent capacity: %70SHR:% of load114Btuh18000Total capacity: Heating Equipment Design Conditions °F66.9Entering coil DB:Btuh13640Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm600Actual airflow: °F50Temp. rise:% of load82kW3.3Output capacity: Meets all requirements of ACCA Manual S. 2021-Apr-27 14:43:50 Right-Suite® Universal 2021 21.0.06 RSU29066 Page 2 ...ghtsoft HVAC\2207 River Hammock Ln PSL Prop.rup Calc = MJ8 Front Door faces: N 1476Job:Manual S Compliance Report 4/27/2021Date:Zone 2 Chris BatemanBy: Air Calcs, LLC 7550 Hidden Hammock Ln, Vero Beach, FL 32966 Phone: 772.800.8413 Email: vickilynne@aircalcs.com Project Information Merritt Residence, Air Conditioning UnlimitedFor: 2207 River Hammock Ln, Fort Pierce, FL 34981 Cooling Equipment Design Conditions °F77.0Entering coil DB:Btuh19785Sensible gain:°F90.4Outdoor design DB: °F64.2Entering coil WB:Btuh5607Latent gain:°F77.4Outdoor design WB: Btuh25393Total gain:°F75.0Indoor design DB: cfm933Estimated airflow:%50Indoor RH: Manufacturer's Performance Data at Actual Design Conditions Split ACEquipment type: GSX160301F+ASPT37C14AModel:Goodman Mfg.Manufacturer: cfm933Actual airflow: % of load99Btuh19600Sensible capacity: % of load150Btuh8400Latent capacity: %70SHR:% of load110Btuh28000Total capacity: Heating Equipment Design Conditions °F67.6Entering coil DB:Btuh19605Heat loss:°F41.0Outdoor design DB: °F70.0Indoor design DB: Manufacturer's Performance Data at Actual Design Conditions Elec stripEquipment type: Model:Manufacturer: cfm933Actual airflow: °F50Temp. rise:% of load83kW4.8Output capacity: Meets all requirements of ACCA Manual S.