HomeMy WebLinkAboutPRODUCT APPROVAL - ROOFING UNDERLAYMENT9/7/2021 Florida Building Code Online
w w .
SCIS Home Log In User Registration Hot Topics submit Surcharge Stats a Facts Publications Contact Us BCIS Site Map Links Search
dbpr I USER:Product Approval
USER: Public User
ProtluR Aoproval Menu > Product or Aonhcation Search > 9Qolicatlon List > Applleation Detail
FL #
Application Type
Code Verslon
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
FL5259-R33
Revision
2020
Approved
POLYGLASS USA
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext 242
malpert@polyglass.com
Maury Alpert
malpert@polyglass.com
TECH REP
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866)802-8017
uspolyglasstechnical@polyglass.com
QA REP
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888)410-1375
uspolyglasstechnical@polyglass.com
Roofing
Underlayments
Evaluatlon Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/23/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence FL5259 R33 COI 2021 01 COI NIEMINEN.gQ
Referenced Standard and Year (of Standard) Standard Year
ASTM D1970 2015
ASTM D226 2009
ASTM D4798 2011
ASTM D6163 2015
ASTM D6164 2011
ASTM D6222 2011
ASTM D6509 2015
hftps://floddabuilding.org/pr/pr_app_dfl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vSa/a2fegOliploQ53LIfLDSdir7nKfKNa/a2bQ°/,3d%3d 1/2
9/7/2021
Florida Building Code Online
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
FM 4474
2011
FRSA/TRI, Sixth Edition
2018
TAS 103
2020
UL1897
2015
Method 1 Option D
04/07/2021
04/12/2021
04/14/2021
06/08/2021
FL # Model, Number or Na escription me D
5259.1 Polyglass Roof Underlayments Polyglass roof underlayments for use in FBC HVHZ jurisdictions. ;
(HVHZ)
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: No
Impact Resistant: N/A
Design Pressure: N/A
Other: Refer to ER Section 5 for Limits of Use.
Installation Instructions
FL5259 R33I1 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
,,ff
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 HVHZ).pjLf
Created by Independent Third Party: Yes
5259.2 I Polyglass Roof Underlayments I Polyglass roof underlayments, for use in FBC non-HVHZ jurisdictions.
(non-HVHZ)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-622.5
Other: 1.) The design pressure in this application
relates to one particular underlayment system for
use In the roof systems. Refer to ER Section 5.8.3
for other systems and associated maximum design
pressures. 2.) Refer to ER Section 5 for other limits
of use.
Installation Instructions
FL5259 R33 II 2021 04 07 FINAL ER PLYG UNDERLAYMENTS FL5259-
R33 (NON-HVHZ)1pdf
Verified By: Robert Nieminen PE-59166
Created by Independent Third Party: Yes
Evaluation Reports
FL5259 R33 AE 2021 04 07 FINAL ER PLYG UNDERLAYMENTS_FL5259m
R33 NON-HVHZ),pdf
Created by Independent Third Party: Yes
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Qgyr aht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statemen
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 4SS, F.S., please click here .
Product Approval Accepts:
M Rwr_:71 ® ER E
Credit Card
Safe
https://floridabuilding.org/prlpr app dtl.aspx?param=wGEVXQwtDgvbSgAaZp3Crk2vS%2fegOliploQ53LIfLDSdir7nKfKN%2bQ%3d%3d 212
MIAMI. E� MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) a'wtv.miamidade.eov/economy
Polyglass USA Inc.
I111 W. Newport Center Drive
Deerfield Beach, FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.17-0614.22 and consists of pages I through 7.
The submitted documentation was reviewed by Jorge L. Acebo.
MIAMI•DADE COUNTY
u . 11
NOA No.: 21-0602.14
Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 1 of 7
ROOFING COMPONENT APPROVAL
Category: Roofing
Sub -Category: Underlayment
Material: SBS, APP
PRODUCTS DESCRIPTION:
Test
Product
Product
Dimensions
Specification
Description
Polystick IR-Xe
65' x 3' Or 33.4' x
ASTM D 1970
A fine granular/sand top surface self -adhering, APP
Manufacturing
3'
polymer modified, fiberglass reinforced, bituminous sheet
Location # 1 & #2
material for use as an underlayment in sloped roof
60 mils thick
assemblies. Designed as an ice & rain shield.
Polystick TU Max
65'8" x 3'3-3/8"
TAS 103 and
A rubberized asphalt self -adhering, polyester reinforced
Manufacturing
60 mils thick
ASTM D 1970
waterproofing membrane. Designed as a a roof tile
Location # 1 & #2
underlayment.
Polystick TU P
32' 10" x 333/8'
TAS 103 and A rubberized asphalt waterproofing membrane, glass -
Manufacturing
130 mils thick
ASTM D 1970 fiber/polyester reinforced, with a granular surface
Location #2
designed for use as a tile roof underlayment.
Polystick TU Plus
65' x 313/s"
TAS 103 and A rubberized asphalt self -adhering, glass-fiber/polyester
(Surface Printing)
80 mils thick
ASTM D 1970 reinforced waterproofing membrane. Designed as a metal
Manufacturing
roofing and roof tile underlayment.
Location # 1 & #2
Polystick MTS
6518" x 3133/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Polystick MTS Plus
65'8" x 3'33/8"
TAS 103 A homogeneous, rubberized asphalt waterproofing
Manufacturing
60 mils thick
membrane, glass fiber reinforced with polyolefinic film
Location #2
on the upper surface for use as an underlayment for metal
roofing, roof tile, slate tiles and shingle underlayment.
Elastoflex S6 G 32' 10" x 3'3 3/a" TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For
Location #2 use in roof tile underlayment systems.
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
NOA No.: 21-0602.14
Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 2 of 7
Test Agency
Trinity I ERD
LABELING:
EVIDENCE SUBMITTED
Test Identifier Test Name/Report
P37300.10.11
P37590.07.13-1
P45270.05.14
P46520.10.14
P44360.10.14
P43290.10.14
PLYG-SC 10130.06.16-3
PLYG-10130.06.16-1
PLYG-SC 10130.09.16
PLYG-SC 13035.08.17
TAS 110/ASTM D4798 & D 1970
ASTM D6164
TAS 103, TAS 110 & ASTM D 1623
ASTM D 1623
TAS 103 & TAS 110
ASTM D 1970 & TAS 110
TAS 103 & TAS 110
ASTM D 1970 & TAS 110
ASTM D 1623
TAS 103 & ASTM D4798
Date
10/19/11
07/02/ 13
05/12/14
10/03/14
10/07/14
10/17/14
06/27/ 16
06/27/16
09/22/16
10/32/17
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami -Dade County Product Control Approved"
or the Miami -Dade County Product Control Seal as shown below.
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 21-0602.14
Cn��wE couNnr Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 3 of 7
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS
or Polystick MTS Plus, self -adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck, membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastoflex S6 G, hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood, non -insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self- adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self -adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus, self -adhered.
Surfacing: See General Limitations Below.
NOA No.: 21-0602.14
MIAMI-DAD; COUNTY Expiration Date: 09/13/22
UnTApproval Date: 08/26/21
Page 4 of 7
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose deck panels, and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3" and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special attention to
lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick TU Plus, Polystick MTS and Polystick MTS Plus may be used in asphaltic shingles, wood shakes
and shingles, non-structural metal roofing, roof tile systems and quarry slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflex S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS
Plus shall be applied to a smooth, clean and dry surface. The deck shall be free of irregularities.
5. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS
Plus shall not be adhered directly over a pre-existing roof membrane as a recover system.
6. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS and Polystick MTS
Plus shall not be left exposed as a temporary roof for longer than the amount of days listed in the table below
after application. Polyglass reserves the right to revise or alter product exposure times; not to exceed the
preceeding maximum time limitations.
Expo ure Limitations (Days)
Polystick
MTS
Polystick
IR-Xe
Elastoflex
S6 G
Polystick
TU Plus
Polystick
TU P
Polystick
TU Max
Polystick
MTS Plus
Winter Haven FL
180
90
180
180
180
180
180
Hazelton PA
NIA
90
N/A
180
N/A
180
NIA
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 21-0602.14
Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 5 of 7
S. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick TU Max, Polystick TU Plus or Elastoflex S6 G may be used in both adhesive set and mechanically
fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for (direct -to -deck) tile assemblies, the maximum roof slope
shall be as follows: (See Table Below)
Tile
Polystick
Elastoflex
Polystick TU Plus,
Polystick
Polystick
System (E3)
Profile
MTS
S6 G
Polystick TU P
TU Max
MTS Plus
MTS Plus with
TU Plus
Flat Tile
Prohibited
4:12
6:12
6:12
5:12
6:12
without battens
Profiled
Prohibited
4:12
6:12
6:12
4:12
6:12
Tile
without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required, they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of the
directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure — two tiles laid
perpendicular to slope followed by a maximum four tile stack parallel to the slope, for a total of 6 tiles — for all
underlayments except Polystick MTS which shall be loaded onto battens.
Roofing Tiles
(6 Max. Per Stack)
iii
bOi U.K P'W,aree INW
POLWRCK TU Plus
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products. Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus,
Polystick MTS, Polystick MTS Plus or Elastoflex S6 G may be used with any approved roof covering Notice
of Acceptance listing Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick
MTS, Polystick MTS Plus or Elastoflex S6 G as a component part of an assembly in the Notice of Acceptance.
If Polystick IR-Xe, Polystick TU Max, Polystick TU P, Polystick TU Plus, Polystick MTS, Polystick MTS
Plus or Elastoflex S6 G are not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the
Miami -Dade County Product Control Section for approval provided that appropriate documentation is provided
to detail compatibility of the products, wind uplift resistance, and fire testing results.
NOA No.: 21-0602.14
Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 6 of 7
POLYGLASS GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers are
cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is acceptable.
Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1 5/s" metal disk as
required in Miami -Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate
of 12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area being
back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
POLYPLUS 50, XtraFlex 50 Premium Modified Wet/Dry Cement or Polyglass PG 500 applied in between the
application of the lap. The use of mastic between the laps does not apply to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass Tile
Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA, must be used on all projects for
pitch/slopes of T712" or greater. It is suggested that on pitch/slopes in excess of 6 '/4"/12", precautions should be
taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
8. Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or exposed
roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass POLYPLUS 50, XtraFlex 50
Premium Modified Wet/Dry Cement or Polyglass PG 500 to the area in need of repair, followed by a patch of the
Polystick material of like kind should be set and hand rolled in place over the area needing such repair. Patching
membrane shall be a minimum of 6 inches in either direction. The repair should be installed in such a way so that
water will run parallel to or over the top of all laps of the patch.
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass requires a
minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are acceptable for
rolling of patches or small areas of the roof. Brooming may be used where slope prohibits rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes can be furnished
upon request by our Technical Services Department by calling 1 (800) 894-4563.
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 894-4563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined by
the National Roofing Contractors Association (NRCA).
PLEASE CHECK WITH LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC APPLICATIONS.
LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 21-0602.14
Expiration Date: 09/13/22
Approval Date: 08/26/21
Page 7 of