Loading...
HomeMy WebLinkAboutPODUCT APPROVAL - ROOFING ACCESSORIES919/21, 9:31 AM Florida Building Code Online t "M t BCIS Home Log In User Registration Hot Topics Submit Surcharge Stabs & Facts Publications Contact Us ]CIS Site Map Links Search bProduct _pr Approval �' USER: Public User EMOU t Approval Menu > Product or Application search > Application List > Application Detail FL tt Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL6267-R17 Revision 2020 Approved GAF 1 Campus Drive Parisppany, NJ 07054 (800)766-3411 mstieh@gaf.com Robert Nieminen Ireith@nemoetc.com Lvbk-aii- William Broussard 1 Campus Drive Parsippany, NJ 07054 (800)766-3411 TechnicalQuestionsGAF@gaf.com Roofing Roofing Accessories that are an Integral Part of the Roofing System Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity ILL LLC Quality Assurance Contract Expiration Date 12/17/2021 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) FL6267 R17 COI 2020 01 COI NIEMIREN 01 Standard Year ASTM D1929 2016 ASTM D635 2014 ASTM E330 2002 ASTM G155 2013 TAS 100(A) 1995 TAS 114, Appendix E 2011 t i Equivalence of Product Standards Certified By https://floridabuilding.org/prlpr app_dtl.aspx7param=wGEVXQwtDquO2YBW7bM8MZAecpwXirhuwn9P2JnjSBT6vUHUJBYLQ%3d%3d 1/2 9/9/21, 9:31 AM Sections from the Code Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 09/21/2020 09/26/2020 10/02/2020 12/15/2020 FL # Model, Number or Name Description 6267.1 GAF Attic Ventilation Products Low profile roof ventilation products I --------------.—. _. ......... Limits of Use Installation Instructions Approved for use in HVHZ: No FL6267 R17 II 2020 09 21 FINAL GAF VENTILATION FL6267- Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-215 Created by Independent Third Party: Yes Other: 1.) The noted design pressures applies to one Evaluation Reports particular vent installation. Refer to ER Section 5.6. 2.) FL6267 R17 AE 2020 09 21 FINAL GAF VENTILATION FL6267-1 Refer to ER Section 5 for Limits of Use. ILP-9 Created by Independent Third Party: Yes j Contact Us :: 2601 Blair Stone Road, Tallahassee Fl. 32399 Phone: 050-487-1824 The State of Florida is an AA/EEO employer. CQRgright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Befund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 4S5.27S(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 45S, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please dldc here. Product Approval Accepts: EM 111K] ® eChtck Credit Card Safe https://floridabuilding.org/prlpr app dtl.aspx?param=wGEVXQwtDqu02YBW7bM8MZAecpwXirhuvvn9P2JnjSBT6vUHUJBYLQ%3d%3d 2/2 MIAMI•�E)■ MIAMI-DARE COUNTY MM PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) It 805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T(786)315.2590 F (786)315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv GAF 1 Campus Drive Parsippany, NJ. 07054 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: GAF Cobra® Exhaust Vent for Roof Ridge LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews and revises NOA No. 18-06I9.02 and consists of pages I through 3. The submitted documentation was reviewed by Jorge L. Acebo. NOA No. 19-0123.05 Expiration Date: 11/09/23 Approval Date: 05/16/19 Page 1 of 3 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Ventilation Materials: Plastic TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description GAF Cobra® Exhaust Vent 3/4" x 10 1/2" x 20' TAS-100 Low profile attic ridge vent for installation for Roof Ridge under ridge shingles. GAF Cobra® Exhaust Vent 5/8" x 10 1/2" x 20' TAS-100 Low profile attic ridge vent for installation for Roof Ridge under ridge shingles. (For nail guns) EVIDENCE SUBMITTED: 1. Acworth, GA. EVIDENCE SUBMITTED: Test Agency/Identifier Name Report Date Intertek - Architectural Testing TAS 100(A) I3223.01-109-18 06/06/18 ASTM D 1929 I3223.02-106-18 R1 07/20/18 ASTM D 635 I3223.02-106-18 R1 07/20/18 ASTM D 2843 I3223.02-106-18 R1 07/20/18 Intertek ASTM D 1929 J0478.01-106-18 RO 01/08/19 ASTM D 635 J0478.01-106-18 RO 01/08/19 ASTM D 2843 J0478.01-106-18 RO 01/08/19 NOA No. 19-0123.05 QMLA•Dd4DE COUNTY Expiration Date: 11/09/23 Approval Date: 05/16/19 Page 2 of 3 APPROVED APPLICATIONS Tradename: GAF Cobra' Exhaust Vent for Roof Ridge System Type: Mechanical attachment of static vent over asphalt shingle roof systems only. Cutout: Cut a 2" slot along the ridge of the roof by cutting 1" on each side of the ridge. Leave uncut sheathing area of 6" at each end of the ridge. Cut through sheathing only, avoiding roof trusses. In buildings with a ridge board, cut 1-3/4" slot on each side. Installation: Roll out ridge vent centered over the slot, and secured 6" o.c. on each side of the ridge with included 2-1/2" corrosion resistant galvanized roofing nails or 1-3/4" collated corrosion resistant galvanized roofing nails (for nail guns) to hold it in place until ridge shingles can be installed. (Polyurethane sealant shall be used to seal the perimeter of the vent to the roof shingles.) Extend to the rake edge. Roll ends or cut joints shall be butted together and caulked with an approved polyurethane sealant. Ridge Shingle: Install pre -manufactured or field -cut ridge shingles over the ridge vent in compliance with the shingle manufacturer's Notice of Acceptance (NOA) and the installation instructions. Ring shank nails shall be corrosion resistant and long enough to penetrate through the wood deck a minimum of 3/16". Apply a bead of polyurethane sealant in between adjacent cap shingles to seal the caps. Net Free Area: Refer to manufacturers published literature. LIMITATIONS: 1. Refer to applicable building codes for required ventilation. 2. This acceptance is for installations over asphalt shingle roof systems only. 3. GAF Cobra® Exhaust Vent for Roof Ridge shall not be installed on roof mean heights greater than 33 feet. 4. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. 5. All approved products listed herein shall be labeled and shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. END OF THIS ACCEPTANCE NOA No. 19-0123.05 Expiration Date: 11/09/23 Approval Date: 05/16/19 Page 3 of 3