Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GAS PIPING
AmeriGas is pleased to offer the following proposal for your consideration; Osteen >a 13 - `I Z 61 Brian Pead Customer Name Sales Representative 18505 Tranquility Base Fort Pierce . Street District Location . Port St Lur��cieCC 772-633-0740 City. State, Yip Cale dF'bH!tll-or2. U's'i�ell Q.� A'I.k:J;Lo..c.... Telephone Description ofymrk: Bury 500 gallon propane tank right side of house run line to generator RR and house stub. Run inside line Homeowner to remove and repair concrete for gas line. Homeowner is responsible for bonding gas line at house stub. Quantitv flasnrintinn Iinit r.nst` "TnfAl- 45 314 witerior as line in sod in300$ 9.45 $425.25 3 Regulators 90 $270:00 2 Gas hookups 195 $390.00 3 Transitions 85 $255.00 4 Shut Offs and flex line at stove " 25 '$100.00 1 500 Gallon tank 28e9 $2 869:00 400 Propane 2.98 $1 192.00 1 lBury and anchor tank with anode 1289 $1,289.00 1 Tee 140 $140.00 65 3/41NT gas tine 25 $1 625,00 TAX T00% $598.87 Permit 1 $250.00 All prices are exclusive of myapplicabletaxes, plumbing and electrical work.. ITOTAL COST $9,404.12 ALL WORK SHALL BE PERFORMED ACCORDING TO FEDERAL, STATE AND LOCAL REQUIREMENTS. All prices are based on astandard installation. Unforeseen circumstances such as poor soil condition, premature installation of concrete, landscaping, sheetrock etc. may result in Increased coats: Change orders must be approved priorto installation and are subject to approval by the authority having jurisdiction. Araert6as will not De resoonsltYle for damage to unmarked Ines (sprinklerr, water, electric, etc.) . Attachments �tsC, S(12 R1., 2 ri,d Brian Pear Accepted by; Date Submitted by: Date 11J2/2021 This proposal Is valid for30 days from the date submitted. ■ Corrugated stainless steel tubing (CSST) gas piping systems will be bonded in accordance with Section G2411.1 (310) of the Florida Building Code and NFPA 54. ■ Underground gas piping will be installed at a minimum depth of 12 inches below grade in accordance with Section G2415.12 (404,12) of the Florida .Building Code and NFPA 58. ■ Polyethylene pipe will be installed in accordance with 6.11.4 of NFPA 58 and the Florida Building Code. Carbon monoxide monitors will be installed prior to inspection and will meet all code and safety requirements of NFPA 54 and the Florida Building Code. Copyright 2017 Natural Fire Protection Association (NFPA®l. Licensed, by agreement, for individual use and download on' W112017 to AmenGes for designated user Brian Peed. No other reproduction or transmission in any form permitted without written permission of NFPA®. For inquires or to report unauthorized use, contact licensing®nfpoeM. . Chapter 16•Pipe and Tubing Sizing Tables TABLE 161(n) Pik!Ye'#,j'�d�Azqm 4tpg- p„ Gas: Undiluted Propane Inlet Pressure: I0.0 prig Pressure Drop: I.0 psig Speer/ie Gravity: 1.52 Plastic Pipe r/2 in. %, in. I in.. I r/1 in. IY= in 2 in. Length SDR 9.33 SDR 11 SDR I1- SDR I] SDR II SDR I] (ft.) (0.660) (0,860) - (1.007) (1.328) (I.554) (�1.943) }, 30 2140 -2390 7740 - 13420 20300 36400 40 1840 3670 6630 11480 17300 31200 50 1630 3260 5870 10180 15400 27600 - 60 1470 2950 5320 9220 13900 25000 70 1360 2710 4900 8480 12800 23000 80 1260 2530 4560 7890 11900 21400 90 1180 2370 - 4270. 7400 11200 20100 100 1120 2240 4040 6990 10600 19000 125 990 990 3580 6200 9360 16800 150 897 897 3240 5620 8480 15200 175 826 826 2980 5170 7800 14000 200 778 778 2780 4810 7260 13000 22.5 721 721 2600 4510 6810 12200 250 681 691 2460 4260 6430 11600 275 646 646 2340 4050 6110 11000 300 617 617 2230 3860 5830 10470 350 567 567 2050 3550 5360 9640 400 528 528 1910 3300 4990 8970 450 495 495 992 3100 4680 8410 500 468 468 937 2930 4420 7950 600 424 424 849 2650 4010 7200 -700 390 390 781 2440 3690 6620 800 363 . 363 726 2270 3430 6160 900 340 340 682 2130 3220 5780 1000 . 322 322 644 2010 3040 5460 1500 258 258 5-17 933 1616 4390 2000 221 - 221 443 498 1383 3750 IPS. Iron Pipe Size. SDR: Standard Dimension Ratio Notes' (1) Capacities are in 1000 B tu/hr. (2) Dimensions in parentheses are inside diameter. 2017 LP -Gas Code Handbook Tk f 1 „y lit O S ll� d Y 'llw Ch ® ,b P .x {� N i w i ii a j'', «8 M"EnNiTI x It 2 ,w rrili G I Lix � J : '-{ 1 $aK - R t8 fi' a tru f :. 4. wwuw ul5 1 rtj5, - :i.3I r 1 , .. ti 1� Ideal for use as a first stage, regulator on any domestic size ASME or Est., DOT container in propane gas installations requiring up to 1,500,000 �L BTU's per hour. The regulator is factory set to reduce container pressure to an intermediate pressure of approximately 10 PSIG. • Maximum flow based on Inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20%lower than the regulator setting and delivery pressure 20%lower than the setting. Provides accurate first stage regulation in two -stage bulk tank so systems.. Reduce tank pressure to an intermediate pressure of 5 to 10 PSIG. Also used to supply high pressure burners for applications like industrial furnaces or boilers. Also incorporated in multiple cylinder installations. LV 44VSJ R9 1I/ F 5 1-5 LV4403TR4 NPT t/i' F. 10 5-10 LV4403SR9 NPT LV4403TR9 1/ 10 5 10 Yes 2,500,000 LV4403SR96 F. POL s4„ 5 1-5 LV4403TR96 F. 10 5-10 ' When used for final stage pressure control, most either incorporate integral relief valve or separate relief valve should be specified in accordance with NFPA Pamphlet 58, '• Maximum flow based on Inlet pressure 20 PSIG higher than the regulator setting and delivery pressure 20% lower than the setting. Low Pressure Second Stage Regulators - Standard Settings LV44038 Series Designed to reduce first stage pressure of 5 to 20 PSIG down to sseo, burner pressure, normally 11" w.c. Ideal for medium commercial �L installations, multiple cylinder installations and normal domestic loads. LV4403B4 '/z" LV4403846 I/P F. NPT Lv4403846R" #28 11" w.c. at10 PSIG 9" to 13" Over Inlet 935,000 LV4403866 '/d' F. NPT Drill Inlet W.G. LV4403B66R* �" F. NPT - eackmount design '. Maximum flow based on 10 PSIG Inlet and 9" w.c. delivery pressure 6 regoproducts.com 1 336.449.7707 LV3403TR LV44035eriee LV4403BSectes '>ror►.-,:.., .,,r .x tie-„^ New Compact "Back -Mount" Regulator LV3403DR Series The LV3403BR Back Mount Regulator is designed to reduce first Wk, stage pressure of 5-10 PSIG down to burner pressure normally 11" w.c. Designed as a second stage regulator for smaller applications with flow requirements up to 450,000 BTU/hr. and are ideal for homes,. mobile homes, and cottages. LV3403B44R Yd' +/," F.NPT r/3R 11" w,c. At 10 9" to 13" Over Inlet 450,000 LV3403B46R - F.NPT a/;' FNPT- PSIG Inlet w.a Maximum flow based on 10 PSIG inlet and 9" w.c. delivery pressure. The LV340384 Is designed to reduce first stage pressure of 5-20 PSIG down to burner pressure normally 11" w.c. Designed.. as a oos", second stage regulator for smaller applications with flow requirements SL - up to 460,000 BTU's/hr, they are ideal for homes, mobile homes, and cottages. LV3403B4V3 11" w.c. At 10 3:0U /d' FNPT 1W RNPT r/U" 9„�c13" LV340304V0 PSIG Inlet Outle LV3403B4V9 9:00 Maximum flow based on 10 PSIG Inlet 9" w.c. delivery pressure Low Pressure Second Stage Regulators LV4403B66RA Series Designed to.reduce first stage pressure of 5 to20 PSIG down to �aliq burner pressure, normally 11" w.c. Ideal for medium commercial SL installations, vapor meter installations and normaldomestic loads. LV4403866RA I IV w.c. at 'a/," F. NPT 'W F. NPT 3116" 10 PSIG 9" to 13" Over LV4403H66RAB•' Inlet - W.C. Inlet Maximum now Is based on 10. •• Mountlnn Bracket Included. Low Pressure Second Stage Regulators - Standard Settings LV5503BSeries Designed to reduce first stage pressure of 5 to 20 PSIG down to oa burner pressure,normally 11" w.c. Ideal for larger commercial and SL industrial applications, multiple cylinder installations and large domestic systems. LV5503B4 1 yi' F. NPT LV550386 LV5503BB a�„ F. NPT 1" F. NPT vaxlmum now is based on 10 PSIG Iniet and 9" w.c. deliv< 450,000 11" "w.cSIG. at 10 I- 9 - 13 Over Inlet 1,600,000 C. LV3403BRSeries LV3403B41lerles LV5503BSeries 8 regoproduct&com 1 336.449.7707 7/16" GALV. CABLE (2)HDG CLAMPS ANCHOR (PULLED GHT) LICAL ANCHORS '8"X40a SINGLE 6" HELIX 2"X30" SINGLE 4" HELIX HELICAL ANCHOR NOTE: 2 PAIRS 14715#/ANCHOR 7/32, 7x19 GALV. CABLE 5600#. BREAKING STRENGTH W/(2)HDG CLAMPS TC ANCHOR (PULLED TIGHT) CABLE SHALL BE COATED, SLEEVED OR HAVE 1 LAYER 30# FELT AGAINST TANK 500 GALLON UNDERGROUND HOLD DOWN DETAIL •'� G E N S �f 0 40111 :41 STATE OF w �;1 0 R -2019-03-18 GENERAL NOTES: 1. HELICAL ANCHORS SHALL HAVE A PULL—OUT CAPACITY AS SHOWN. ANCHORS SHALL BE INSTALLED PER ANCHOR MANUFACTURER TO ACHIEVE STATED LOAD CAPACITY. CAPACITY. VARIES WITH SOIL TYPE, VERIFY ANCHOR CAPACITY WITH SOIL TYPE ENCOUNTERED, 2. CHECK FOR UNDERGROUND UTILITIES PRIOR TO ANCHOR INSTALLATION 3. LOCATION OF TANK RELATIVE TO ADJACENT STRUCTURES AND FEATURES ARE DEPENDENT UPON LOCAL CODES AND IS THE RESPONSIBILITY OF OTHERS. ` 4. THE TANK AS SHOWN HAS BEEN DESIGNED TO PREVENT FLOTATION, COLLAPSE, OR LATERAL MOVEMENT DURING THE BASE FLOOD EVENT CONTRACTOR TO LOAD TEST 4" ANCHORS AFTER INSTALLATION AMERIGAS © COPYRIGHT 2018 — FARLEY ENGINEERING, LLC Consulting Engineer #401 l'1 — CA28108 8800 N. U.S. M1, Suite #2 , Sebastian, Florida 32958 (772) 560.6229 (772) 589.2296 fax ARCOSA TANK s 0 ww x L a o OUTSIDE w p DIAMETER > a O O F O WITHDRAWAL VALVE GENERAL SPECIFICATIONS CONNECTION FLOAT O¶w ANODE ECTION Conforms to the latest edition and addenda of the ASME code for O ®'' FILLER Pressure Vessels, Section All, Division 1. Complies with NFPA 58. VALVE Rated at 250 psig from -20° F. to 1259 F, All tanks may be evacuated to a full (14.7 psi) vacuum. Vessel Finish: Coated with epoxy and red powder. (Tanks coated MU RV a E �. PLATE with the epoxy powder must be buried). For Aboveground use, tanks will be coated with Ari zinc rich epoxy primer and RELIEF VALVE super durable Ti polyester topcoat. 'Applicable federal, state, or local regulations may contain specific requirements for protective coatings and cathodic protection. The purchaser and installer are responsible for compliance with all federal state, local and NFPA Industry regulations, Cathodic protection is required and coating must be continuous and uninterrupted and must complywith local, state or national code. • • • •� • ii�Water Quality outside Head Overall Overall Leg Leg Weight Full Per Capacity Diameter Type Length Height Width. Spacing .Load Stack 120 wg. 24" EI lip 5'- 513/16" 3' - 3/16" 101/8" 3' - 0" 245 lbs. 96 12 454.2L 609.6 mm 1,671.6 mm 919.1 mm 257.2 mm 914.4 mm 111.1 kg. 250 wg. 31.Y Hemi 7' - 21/2" 3' - 711/16" 12 3/4" 3' - 6" 472 lbs. 63 9 946 3 L 800.1 mm 2,197.1 mm 1,109.6 mm 323.9 mm 1,066.8 mm 214.1 kg. 320 wg. 31.5" Hemi 8'-113/4" 3' - 711/16" 12 3/4" �4 - 01/4" 588 lbs. 45 9 - 1,2112 L 800.1 mm 2,736.9 mm 1,109.6 mm 323.9 mm 1.225.6 mm 266.7 kg. 500 wg. 37.42" Hemi 9' -10" 4'-1 5/8" 15" 5' - 0" 871 lbs. 30 6 1,892.5 L 950.5 mm 2,997.2 mm 1,260.4 mm 381.0 mm 1,524.0 mm 395.1 kg 1000 Wg. 40.96" Hemi 15'-1013/16" 4' - 5 3/16" 161/4" 9' - 0" 1,729 lbs 15 5 3,785.0 L 1,040.4 mm 4,846.6 mm 1,350.9 mm 412.8 mm 2,743.2 mm 784.3 kg. All vessels dimensions are approximate. Eng. Update: Apru 5, ZUR) For more information 888.558.8265