Loading...
HomeMy WebLinkAboutKSM SOIL COMPACTION REPORTHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net KSM JOB #:219929-1d/BS/jam NUC #456 Nuc Model:MC-1 Elite Nuc Serial #:31456 10 Montoya Fort Pierce, Florida Compacted Foundation Fill DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1 N.W.0" - 12"45 107.9 110.0 98.1% 2 N.E.""108.4 "98.5% 3 Center ""108.3 "98.5% 4 S.E.""108.6 "98.7% 5 S.W.""108.8 "98.9% Proctor Optimum Moisture: Proctor Max. Dry Density: P.C.F. @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets 12/27/2021 Certified Women Owned Business - WBE Minimum Requirement for Staked Foundation In Place Moisture: SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 December 23, 2021DATE TESTED: 8.6% 12.0% Brown Sand Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting Respectfully Submitted: ITEM TESTED: 110.0 TEST LOCATION OF SAMPLE Proudly Serving Florida since 1990 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test.KSM is not responsible if the tested area has been altered from the approved inspected condition. PERMIT #: CONTRACTOR:Wynne Development 21100708 Julie E. Keller, P.E. President Soil Description: JOB LOCATION: Email to: dotty@wynnebc.com PE # 68366 Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing 105.0 106.0 107.0 108.0 109.0 110.0 111.0 7 8 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight