HomeMy WebLinkAboutKSM SOIL COMPACTION REPORTHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB # :2110557-1pd/BS/jam
PERMIT #:2108-0377
CONTRACTOR:A & G Concrete Pools NUC #456
Nuc Model:MC-1 Elite
4551 St. Lucie Blvd.Nuc Serial #:31456
Fort Pierce, Florida
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE
PERCENT
COMPACTION
1 North 0'-1'45 111.2 114.7 96.9%
2 1'-2'"-"95.0% +
3 2'-3'"-"95.0% +
4 3'-4'"-"95.0% +
5 West 0'-1'45 111.4 114.7 97.1%
6 1'-2'"-"95.0% +
7 2'-3'"-"95.0% +
8 3'-4'"-"95.0% +
9 South 0'-1'45 110.9 114.7 96.7%
10 1'-2'"-"95.0% +
11 2'-3'"-"95.0% +
12 3'-4'"-"95.0% +
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
12/27/2021PE # 68366
Disclaimer:Contractor is responsible to maintain the pool
backfill in the condition that KSM completed the indicated
passed compaction test.KSM is not responsible if the
poolbackfill has been altered from the approved inspected
condition.
Brown Sand with Traces of Rock
Minimum Requirement
Email to: abirmingham@angpools.com
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Maverick Float Tank/2107287
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
Proudly Serving Florida since 1990
Certified Women Owned Business - WBE
11.0%
ITEM TESTED :
Soil Description:
114.7
Penetrometer reading indicate the
TEST LOCATION
OF SAMPLE
DATE TESTED:
In Place Moisture:
Respectfully Submitted:
PO:
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
8.7%
December 23, 2021
Pool Backfill Compaction
for Plumbed Backfill
JOB LOCATION:
Julie E. Keller, P.E. President
Degree of Compaction Meets
109.0
110.0
111.0
112.0
113.0
114.0
115.0
116.0
6 7 8 9 10 11 12 13 14
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight