Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL WINDOW HORIZONTAL SLIDER 11/29/21, 12:50 PM Florida Building Code Online FLOPIOA OVARTMENT OF d Business & iYl „ tIF _ ProfessionalRegulation r BCIS Home I Log In I User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links Search bpr Product Approval` USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail OFFICE OF THE FL# FL16804-R6 SFCRETARY Application Type Revision Code Version 2020 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived Product Manufacturer Eastern Architectural Systems Address/Phone/Email 16341 Domestic Ave. Ft. Myers, FL 33912 (800)432-2204 Ext4305 easengineering@easternmetal.com Authorized Signature James Flesher easengineering@easternmetal.com Technical Representative Jim Flesher Address/Phone/Email 10030 Bavaria Rpad Fort Myers, FL 33913 (800)432-2204 jflesher@easternmetal.com Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S2/A440 2011 ASTM E1886 2012 ASTM E1996 2012 TAS201 1994 TAS202 1994 TAS203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL16804 R6 Equiv FL16804 AAMA EQ.pdf FL16804 R6 Equiv FL16804 ASTM EQ,pdf https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsclyp4ruwl9w6c7gkK93tR4fyMLlfll7Eg%3d%3d 1/3 11/29/21, 12:50 PM Florida Building Code Online Product Approval Method Method 1 Option A Date Submitted 02/23/2021 Date Validated 02/25/2021 Date Pending FBC Approval Date Approved 03/03/2021 Summary of Products FL# Model,Number or Name Description 16804.1 Series 143 Vinyl HR Non-Impact Fin Series 143 Vinyl HR Non-Impact Fin Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL16804 R6 C CAC NI011728-R4.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant: No 08/30/2024 Design Pressure: +50.0/-50.0 Installation Instructions Other: Maximum Size: 72"x 60",Approved Configurations FL16804 R6 II 08-02251A.pdf XO,OX. FRAME MATERIAL TO BE RIGID PVC FROM Verified By: Luis R. Lomas, P.E. 62514 DECEUNINCK NORTH AMERICA AAMA CERTIFIED(DEP-1) Created by Independent Third Party: Yes Evaluation Reports FL16804 R6 AE 512971B.pdf Created by Independent Third Party: Yes 16804.2 Series 143 Vinyl HR Non-Impact Series 143 Vinyl HR Non-Impact Flange Flange Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL16804 R6 C CAC NI012135-Rl.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: No 07/31/2024 Design Pressure: +35.0/-40.0 Installation Instructions Other: Maximum Size: 74"x 72",Approved Configurations FL16804 R6 II 08-02526A.pdf XO,OX. FRAME MATERIAL TO BE RIGID PVC FROM Verified By: Luis R. Lomas, P.E. 62514 DECEUNINCK NORTH AMERICA AAMA CERTIFIED(DEP-1) Created by Independent Third Party: Yes Evaluation Reports FL16804 R6 AE 513297B.pdf Created by Independent Third Party: Yes 16804.3 SERIES 176 HR PVB VINYL SERIES 176 HR PVB VINYL HORIZONTAL SLIDING WINDOW HORIZONTAL SLIDING WINDOW Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL16804 R6 C CAC NI015126.02.pdf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2024 Design Pressure: +60/-60 Installation Instructions Other: FRAME MATERIAL TO BE RIGID PVC FROM FL16804 R6 II 08-03657.pdf DECEUNINCK NORTH AMERICA AAMA CERTIFIED(DEP-1). Verified By: Luis Roberto Lomas 62514 GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF Created by Independent Third Party: Yes THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE Evaluation Reports FOR KURARAY INTERLAYERS. FL16804 R6 AE 514773.pdf Created by Independent Third Party: Yes 16804.4 SERIES 176 HRP 333 PVB VINYL SERIES 176 HRP 333 PVB VINYL HORIZONTAL SLIDING HORIZONTAL SLIDING WINDOW WINDOW XOX Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL16804 R6 C CAC NI015126.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2024 Design Pressure: +60/-60 Installation Instructions Other: FRAME MATERIAL TO BE RIGID PVC FROM FL16804 R6 II 08-03658.pdf DECEUNINCK NORTH AMERICA AAMA CERTIFIED(DEP-1). Verified By: Luis Roberto Lomas 62514 GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF Created by Independent Third Party: Yes THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE Evaluation Reports FOR KURARAY INTERLAYERS. FL16804 R6 AE 514774.pdf Created by Independent Third Party: Yes 16804.5 SERIES 176 HRP 424 PVB VINYL SERIES 176 HRP 424 PVB VINYL HORIZONTAL SLIDING HORIZONTAL SLIDING WINDOW WINDOW XOX Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL16804 R6 C CAC NI015126.01.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 11/30/2024 Design Pressure: +60/-60 Installation Instructions Other: FRAME MATERIAL TO BE RIGID PVC FROM FL16804 R6 II 08-03659.pdf https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsclyp4ruwl9w6c7q kK93tR4fyM L 1 fl l7Eg%3d%3d 2/3 11/29/21, 12:50 PM Florida Building Code Online DECEUNINCK NORTH AMERICA AAMA CERTIFIED(DEP-1). Verified By: Luis Roberto Lomas 62514 GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF Created by Independent Third Party: Yes THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE Evaluation Reports FOR KURARAY INTERLAYERS. FL16804 R6 AE 514775.pdf Created by Independent Third Party: Yes 16804.6 Series 176 Vinyl HR Impact HVHZ Series 176 Vinyl HR Impact HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL16804 R6 C CAC NIO12196.04-R3.pdf Approved for use outside HVHZ:Yes Quality Assurance Contract Expiration Date Impact Resistant:Yes 06/30/2024 Design Pressure: +70.0/-85.0 Installation Instructions Other: Maximum Size: 74"x 63", Nailing Fin or Flange, FL16804 R6 II 08-02537B.pdf Approved Configurations XO,OX. FRAME MATERIAL TO BE Verified By: Luis R. Lomas, P.E. 62514 RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA Created by Independent Third Party: Yes CERTIFIED(DEP-1). GLASS INTERLAYER COMPLIES WITH THE Evaluation Reports REQUIREMENTS OF THE FLORIDA BUILDING CODE FL16804 R6 AE 513310C.pdf ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS. Created by Independent Third Party: Yes WHEN USED IN THE HVHZ OUTBOARD LITE MUST BE TEMPERED GLASS. 16804.7 Series 176 Vinyl HRP 1/3- 1/3- 1/3 Series 176 Vinyl HRP 1/3- 1/3 - 1/3 Impact HVHZ Impact HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL16804 R6 C CAC NI012196.01-R2.pdf Approved for use outside HVHZ:Yes FL16804 R6 C CAC NI012196-R3.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +65.0/-85.0 06/30/2024 Other: Maximum Size: 111"x 63", Nailing Fin or Flange, Installation Instructions Approved Configuration XOX. FRAME MATERIAL TO BE RIGID FL16804 R6 II 08-02534B.pdf PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED Verified By: Luis R. Lomas, P.E. 62514 (DEP-1). GLASS INTERLAYER COMPLIES WITH THE Created by Independent Third Party: Yes REQUIREMENTS OF THE FLORIDA BUILDING CODE Evaluation Reports ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS. FL16804 R6 AE 513306C.pdf WHEN USED IN THE HVHZ OUTBOARD LITE MUST BE Created by Independent Third Party: Yes TEMPERED GLASS. 16804.8 Series 176 Vinyl HRP 1/4- 1/2- 1/4 Series 176 Vinyl HRP 1/4- 1/2- 1/4 Impact HVHZ Impact HVHZ Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL16804 R6 C CAC NI012196.02-R2.pdf Approved for use outside HVHZ:Yes FL16804 R6 C CAC NI012196.03-R2.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: N/A 06/30/2024 Other: Maximum Size: 111"x 63", Flange Installation Design Installation Instructions Pressure: +50.0/-65.OPSF, Nailing Fin Installation Design FL16804 R6 II 08-02536B.pdf Pressure: +55.0/-60.OPSF,Approved Configuration XOX. Verified By: luis R. Lomas, P.E. 62514 FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK Created by Independent Third Party: Yes NORTH AMERICA AAMA CERTIFIED(DEP-1). GLASS Evaluation Reports INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FL16804 R6 AE 513308C.pdf FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR Created by Independent Third Party: Yes KURARAY INTERLAYERS.WHEN USED IN THE HVHZ OUTBOARD LITE MUST BE TEMPERED GLASS. Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ® U Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtmmTSTNdVPsclyp4ruwl9w6c7gkK93tR4fyMLlfll7Eg%3d%3d 3/3 REVISIONS REV DESCRIPTION DATE APPROVED NOTES: 15. FOR FRAME ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH 1 . THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR FRAME ANCHORING INTO MASONRY/CONCRETE USE 1/4" TAPCONS WITH SUFFICIENT TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2'' MINIMUM 3. 1 X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 11/2" WINDOW UNITS MUST BE 17. FOR FRAME ANCHORING INTO METAL STRUCTURE USE #10 SMS OR SELF DRILLING SCREWS ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO 18. ALL FASTENERS TO BE CORROSION RESISTANT. MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR 5. WHERE WOOD BUCK THICKNESS IS 1 -1/2" OR GREATER, BUCK SHALL BE SECURELY MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH A. WOOD — MINIMUM SPECIFIC GRAVITY OF G-0.42 MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. B. CONCRETE — MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. 6. WHERE 1 X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED C. MASONRY — STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF D. METAL STRUCTURE: STEEL 18GA, 33K& OR ALUMINUM 6063—T5 .125" THICK MINIMUM THE ARCHITECT OR ENGINEER OF RECORD. 20. UNITS MAY BE INSTALLED WITH OR WITHOUT FLANGE, OUTSIDE THE HVHZ. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS 21 . APPROVED CONFIGURATIONS: XO, OX. PROVIDED. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/1 6" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd1 .6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11 . FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300, SEE SHEET 8 FOR GLASS DETAILS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR FIN INSTALLATION INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/2" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED: 0111412021 OF EavrernEASTERN ARCHITECTURAL SYSTEMS �• EASTERN METAL SUPPLY - 16341 DOMESTIC AVE .- \, r r r • r ��/� /- . A=eT+iw oo ar�o�voi e�� FORT MYERS,FL 33912 .,',.•- 800-432-2204y�� TABLE OF CONTENTS SERIES 176 HR PVB VINYL HORIZONTAL SLIDING *■ �$I WINDOW 73" X 62" r SHEET N0. DESCRIPTION NOTES . w TAT QF �'�� 1 NOTES DRAWN: DWG NO. REV �����n ��R`Mot' 3 HORIZON NS TAL CROSS SECTIONS A.R.E NTS DATE 01 07 21 08 s03657 OF 8 — }E[a���� 1 4 7 INSTALLATION DETAILS L.ROBERTOLOMASP.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 8 COMPONENTS AND GLAZING DETAIL 434-688-0609 rllomaswlrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED 73" FRAME WIDTH 73" FRAME WIDTH 6" MAX 1 6" MAX MAX O.C. 4" MAX MAXI 02C. 4" MAX 6" MAX 4" MAX 1 1 1/2" / MAX O.C. 18" x O �. MAX x O O.C. 62" => FRAM E 62" HEIGHT => FRAME HEIGHT 6" MAX 4" MAX . . . . . SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW SERIES 176 SS VINYL HORIZONTAL SLIDING WINDOW EXTERIOR VIEW EXTERIOR VIEW FINLESS INSTALLATION FIN INSTALLATION DESIGN PRESSURE RATING IMPACT RATING +60.OPSF LARGE MISSILE IMPACT MISSILE LEVEL D, WIND ZONE 4 AND HVHZ NOTES: 73"X 62"UNIT SHOWN. OTHER SIZES APPROVED AS LONG AS 1 . SASH SIZE: 36 1/8" X 59 3/8" FRAME AREA DOES NOT EXCEED 31.4 FT2 SIGNED: 0111412021 2. SASH D.L.O.: 32 3/4" X 55 7/8" EASTERN ARCHITECTURAL SYSTEMS 3. FIXED D.L.O.: 32 3 4" X 57 3 16" �► ADIVISION OF / / Ea EASTERN METAL SUPPLY �,,,,,R. L 0O �f f 4. (2) WEEPS WITH COVER (97-03) AT SILL FACE 2" FROM EACH CORNER. ti 5 J 16341 DOMESTIC AVE � , � ' • % / 5. 2 1 1 2" X 1 4" WEEP SLOT AT SILL FACE 2" FROM EACH CORNER. �; A,e:+�w oo a a�� a�, FORTMYERS,FL33912 �� �,' • 9 ( ) / / �. 600-432-2204 = �, y`L V .L 6. (2) 1/2" X 1/8" WEEP SLOT AT SILL BEHIND GLAZING LEG. . SERIES 176 HR PVB VINYL HORIZONTAL SLIDING *4- T?-;gO I •�k WINDOW 73" X 62" ELEVATION 0OF •'�� HARDWARE SCHEDULE ��,5�•t • �� A. (2)ASHLAND DUAL KEEPERS (13999)AT FIXED MEETING STILE 8" FROM HEAD & SILL DRAWN: DWG No. REV '�s C.B. (2) ROLLERD DUAL LOCKS (D21 00AL/R)HOUS HOUSINGS AT EACH CORNER SASH OFSASHCK STILE 8"BOTTOM RAIL FROM SASH CORNERS ARE NTS DATE 01 07 21 08 s03657 OF 8 - ����S�nNAL}Ea���� ( ) � 2 D. (2)TRACKS AT OPERABLE SASH HEAD & SILL L.ROBERTOLOMASP.E. E. (1)ALUMINUM REINFORCEMENT(55556) IN FIXED MEETING RAIL 1432 WOODFORD RD LEWISVILLE,NC 27023 Luis R. Lomas P.E. F. (5)ALUMINUM REINFORCEMENT(55557) IN SASH TOP AND BOTTOM RAILS, JAMB STILES AND SASH LOCK RAIL 434-688-0609 rllomasCa-)lrlomaspe.com FL No.: 62514 I REVISIONS REV DESCRIPTION DATE APPROVED INTERIOR a� �a oo a0 a o ® o ® ® o a a a a a a a a 0o a o 00 EXTERIOR HORIZONTAL CROSS SECTION FINLESS INSTALLATION INTERIOR BOO Oa 0o a0 Q O ® o ® o a o a a a a a a a a o o a EXTERIOR HORIZONTAL CROSS SECTION FIN INSTALLATION SIGNED: 0111412021 EASTERN ARCHITECTURAL SYSTEMS �• OF owlilillw/EASTERN METOA�L SUPPLY - 16341 DOMESTIC AVE .\ \, r r r • r ��/� /- .� A=eT+iw oo ar�o�voi e�� FORT MYERS,FL 33912 .,•,••- 800-432-2204y�� s .cA SERIES 176 HR PVB VINYL HORIZONTAL SLIDING *■ �$I WINDOW 73" X 62" r HORIZONTAL CROSS SECTIONS 0 w TAT OF �� DRAWN: DWG NO. REV ���.�L�R`D�• \��� A R.SCALE DATE 08 s0E 657 ��;/�jS/0N8 a Eaj NTS 01/07/21 3 OF 8 Il II1II L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomas�lrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED 1/2" MIN. EDGE DISTANCE WOOD FRAMING OR 2X BUCK BY OTHERS 1 1/4" MIN. EMBEDMENT �� flao 1 1/4" MIN. 1/4" MAX.EMBEDMENT SHIM SPACE BACKER ROD 1/4" MAX. & APPROVED SEALANT SHIM SPACE T- INTERIOR 1/2" MIN. �0 EDGE DISTANCE 010 WOOD SCREW 0 0 #10 WOOD EXTERIOR INTERIOR SCREW � WOOD FRAMING a OR 2X BUCK BY OTHERS EXTERIOR O 0 D BACKER ROD 0 0 & APPROVED #10 WOOD SEALANT SCREW JAMB INSTALLATION DETAIL O O WOOD FRAMING OR 2X BUCK INSTALLATION BACKER ROD "CL & APPROVED 1/4" MAX. SEALANT � SHIM SPACE � u WOOD FRAMING 0 O 1 1/4" MIN. R 2X BUCK BY OTHERS EMBEDMENT 1/2" MIN. SIGNED: 0111412021 EDGE DISTANCE EASTERN ARCHITECTURAL SYSTEMS VERTICAL CROSS SECTION Easters A DIVISION OF ;� 5 R L o EASTERN METAL SUPPLY , I � 16341 DOMESTIC AVE .� \, r r r • r 4 /- WOOD FRAMING OR 2X BUCK INSTALLATION A LLl M 1 N lJ M A N O VINYL FORT MYERS,FL 33912 v �+ {� '9 800-432-2204 = 'y,L �V .� SERIES 176 HR PVB VINYL HORIZONTAL SLIDING *■ p $q ��*�_ WINDOW 73" X 62" INSTALLATION DETAILS 0 w 0. TAT OF �'p� NOTES: DRAWN: DWG NO. REV �, ' • 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, A.R. 08-03657 — Z;e/sNOT SHOWN FOR CLARITY. S'j� 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SCALE NTS DATE 01/07/21 S HEET 4 OF S AL}1���� DESIGNED IN ACCORDANCE WITH ASTM E2112 L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED 1/2" MIN EDGE DISTANCE M ETAL STRUCTURE BY OTHERS 1/4" MAX. SHIM SPACE APPROVED � D�O SEALANT a 1 MAX. SHIMW SPACE #10 SMS OR 0 SELF DRILLING INTERIOR SCREW 1/2" MIN. 7F9 EDGE DISTANCE EXTERIOR INTERIOR #10 SMS OR SELF DRILLING SCREWS O D O METAL o a STRUCTURE #10 SMS OR ° O BY OTHERS EXTERIOR n LJ SELF DRILLING BACKER ROD 0 o SCREW & APPROVED JAMB INSTALLATION DETAIL BACKER ROD SEALANT METAL STRUCTURE INSTALLATION'pq & APPROVED SEALANT 1/4" MAX. u SHIM SPACE 0 METAL � STRUCTURE BY OTHERS 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION SIGNED: 0111412021 METAL STRUCTURE INSTALLATION EASTERN ARCHITECTURAL SYSTEMS �• A DIVISION OF vII, Easte EASTERN METAL SUPPLY - 16341 DOMESTIC AVE .� \, r r r • r ��/� /- - ALUMINUM .wNo VINYL FORT MYERS,FL 33912 L' �^ r _ v, 800-432-2204 �• y` V4. •L SERIES 176 HR PVB VINYL HORIZONTAL SLIDING *■ p $I WINDOW 73" X 62" r INSTALLATION DETAILS 0 w TAT OF �'�� NOTES: DRAWN: DWG N0. REV �, • 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, A.R. 08-03657 — zNOT SHOWN FOR CLARITY. �/sS'j■ ■ ■ E� t� 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SCALE NTS DATE 01/07/21 S HEET 5 OF 8 �nllAlLti���,, DESIGNED IN ACCORDANCE WITH ASTM E2112 L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 434-688-0609 rllomasgIrlomaspe.com F L No.: 6251 4 REVISIONS REV DESCRIPTION DATE APPROVED 2" MIN. EDGE DISTANCE ° ° CONCRETE/ ° MASONRY � � a� °° ° a BY OTHERS ° 1 1/4" MIN. °a a ° EMBEDMENT 1 1/4" MIN. EMBEDMENT 1/4" MAX. SHIM SPACE 0 ° OPTIONAL 1 X BUCK SEE NOTES 3 — 7 1/4" MAX. 2" ° SHEET 1 SHIM SPACE MIN. EDGE INTERIOR DISTANCE °° 1/4" TAPCON BACKER ROD o & APPROVED SEALANT INTERIOR � 1/4" TAPCON v EXTERIOR ° ° CONCRETE/ o a MASONRY BACKER ROD BY OTHERS o EXTERIOR v v & APPROVED ° SEALANT O 0 O OPTIONAL 1X BUCK BACKER ROD o SEE NOTE 3 7 a & APPROVED n 0 SHEET 1 SEALANT LJ 1/4" TAPCON 0 o JAMB INSTALLATION DETAIL 1/4" MAX. CONCRETE/MASONRY INSTALLATION OPTIONAL 1 X BUCK � jnl � SHIM SPACE SEE NOTE 3 — 7 SHEET 1 NOTES: 0 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. CONCRETE/ ° 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE MASONRY ° ° ° o ° a ° ° 11 /4" MIN. DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 0111412021 BY OTHERS - d ° ° ° ° ° ° - - ° - EMBEDMENT EASTERN ARCHITECTURAL SYSTEMS ° A DIVISION OF i Easters EASTERN METAL SUPPLY ;�,,y. R1. L�O A,II�ff� 4 - 16341 DOMESTIC AVE .� \,i7 r r r • r �/� / ° d - ALL1MINlJM ANO VINYL FORT MYERS,FL 33912 �� L' EN{� 800-432-2204 �• y` V�. •� 2" MIN. kR. S 176 HR PVB VINYL HORIZONTAL SLIDING *■ ?.;40 q EDGE DISTANCE WINDOW 73" X 62"INSTALLATION DETAILS 0 - �'�� VERTICAL CROSS SECTION DWG NO. REV �'�`�•:�L0R10t CONCRETE/MASONRYINSTALLATION DATE 08 s03657 — n�(AL S 01/07/21 6 OF 8 �l II l Iti L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED APPROVED SEALANT BEHIND FIN 1 1/2" MIN. EMBEDMENT #10 WOOD WOOD SCREW FRAMING BY OTHERS 1/4" MAX S1HIM SPACE WOOD FRAMING OTHERS � SHIM SPACE 7/16" MIN EDGE DISTANCE INTERIOR 0 1 1/2" MIN. o EMBEDMENT EXTERIOR INTERIOR #1 o wooD SCREW a EXTERIOR O D APPROVED o SEALANT 7/16" MIN 0 BEHIND FIN EDGE DISTANCE JAMB INSTALLATION DETAIL O O 1/4„ MAX WOOD FRAMING OR 2X BUCK INSTALLATION � SHIM SPACE I NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, 7/16" MIN NOT SHOWN FOR CLARITY. EDGE DISTANCE 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE #10 WOOD WOOD DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED: 0111412021 SCREW FRAMING EASTERN ARCHITECTURAL SYSTEMS 1 1/2" MIN. BY OTHERS �� A DIVISION OF ,�111t11dI11/// EMBEDMENT Eas �� EASTERN METAL SUPPLY ;�, y. R.. LO�(ff� 16341 DOMESTIC AVE /- APPROVED ALL1MINlJM ANO VINYL FORT MYERS,FL 33912 v Af f,'v'` ..,_...e. w..,00...a .....� ooe..� 6U6-432-2264 =���y`G 7! �• L SEALANT VERTICAL CROSS SECTION �. BEHIND FIN SERIES 176 HR PVB VINYL HORIZONTAL SLIDING *■ �81 �.*r WOOD FRAMING OR 2X BUCK INSTALLATION WINDOW 73" X 62" FIN INSTALLATION DETAILS 0 w TAT 0 �'., DRAWN: DWG N0. REV ��fi�.;�L�R1D�;+ \��� A RE DATE 08 s03657 - �/sS�n�(AL Eaj��` NTS 01/07/21 7 OF 8 Il II 1 II L.ROBERTOLOMASP.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED 4" n 4" U 1 1/2„ 1 ' 3 1/2" o OU 3 o [D"0910 0 1 3/4 3/4„ O MAIN FRAME MAIN FRAME (4731) BOTTOM RAIL (5539) LOCK RAIL (4720) FIN INSTALLATION (4761) EXTRUDED RIGID PVC EXTRUDED RIGID PVC EXTRUDED RIGID PVC EXTRUDED RIGID PVC 1 3/4" 1/4" 1 1/16" � 2 1/4" r O 1 3/8" 1 1/1 6"L 7/1 6" FIXED MEETING RAIL (4719) GLAZING BEAD (5464) REINFORCEMENT(55556) REINFORCEMENT(55557) EXTRUDED RIGID PVC EXTRUDED RIGID PVC 6005-T5 ALUMINUM 6005-T5 ALUMINUM 1 " 1/8" ANN 1/8" ANN .090" PVB BY KURARAY EXTERIOR 1/8" ANN INTERIOR SIGNED: 01/14/2021 EASTERN ARCHITECTURAL SYSTEMS CARDINAL XL EDGE �� ADIVISION OF Easte� EASTERN METAL SUPPLY �,, R. L�O,I�f f STAINLESS STEEL 16341 DOMESTIC AVE 'N \5 . • • • . 4f A LL1MINlJM ANO VINYL FORT MYERS,FL 33912 . q . DUAL SEALED SPACER �+ {� w..,00...a .....� ooe..� 800-432-2204 = ENO* .� GLAZING BEAD STRUCTURAL SEALANT SERIES 176 HR PVB VINYL HORIZONTAL SLIDING *■ p $I ••ik�_ SIKAELEX 552 WINDOW 73" X 62" z - COMPONENTS AND GLAZING DETAIL 0 w TAT OF •'�� 1/2" BITE 0 SETTING BLOCK (30096) �0. 0 85 DUROMETER DRAWN: DWG NO. REV �j�¢` .��RID�; N�`�� II BY CENTRAL RUBBER ARE DATE 08 s03657 - ��/ nNAL NTS 01/07/21 8 OF 8 Il II l Iti GLAZING DETAIL L.ROBERTOLOMASP.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 F L No.: 62514 434-688-0609 rllomasglrlomaspe.com