Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFING UNDERLAYMENTSFlorida Building Code Online 11/30/21, 8:04 PM a y". { BCIS Home ! Log In User Registration Hot Topics Submit Surcharge I Stats & Facts Publications Contact Us I BCIS Site Map Links I Search LOri ; Product Approval M USER: Public User LFS;QTe. 1084 rlr - Product Apg_roval Menu > Proc u cr Application Search > Application List > Application Detail ei. `y FL # FL11602-R13 M - Application Type Revision Code Version 2020 Application Status I ,� Approved " Comments Archived O Product Manufacturer Owens Corning Roofing and Asphalt, LLC Address/Phone/Email One Owens Corning Parkway Toledo, OH 43645 (740) 321-6345:='. Greg.Keeler@owenscorning.com Authorized Signature Keeler Greg Greg.Keeler@owenscorning.com Technical Representative Greg Keeler 1 Address/Phone/Email 2790 Columbus Road Granvilld'OH4'3023 ,(740) 321-6345:,: .. { " , greg.keeler@c!vy6nscorning.com. Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory - Underlayments Compliance Method "Evaluation Report from a, Florida. Registered Architect or a Licensed Florida — - . - Professional Engineer- 1], Evaluation Report - HardcopyReceived Florida Engineer or Architect Name who "developed Robert Nieminen the Evaluation Report - - Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date, 12/31/2023 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FU1602 R13 COI 2021_Q], COI NIEMINEN.p-df Referenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 ASTM D4533 (tear strength) 2015 httpsi//www.floridabuilding.org/pr/pr_app_dtl:aspx?param=wGEVXQwtDgsQFc5K%2fTrZeHYB7UCe5KMr%2fsMfWgra38sP60YHMVvylw%3d%3d Page 1 of 2 Florida Building Code Online Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products r ASTM D4798 (weathering) ASTM D4869 (liquid transmission) ASTM D5035 (tensile) FRSA/TRI, Sixth Edition UL 1897 Method 1 Option D 04/19/2021 04/19/2021 04/26/2021 06/08/2021 11/30/21,.8:04 PM 2011 2016 2011 2018 2015 FL # Model, Number or Name Description 11602.1 Titanium Roof Underlayments for Synthetic sheet -type roof underlayments use in FBC non-HVHZ jurisdictions Limits of Use Installation Instructions Approved for use in HVHZ: No FL11602 R13 11 2021J 1 FINALS TITANIUM FL11602- Mud Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-142.5 Created by Independent Third Party: Yes Other: 1.) The design pressure noted Herein pertains to Evaluation Reports use of a specific underlayment system beneath.tile roof FL11602_R13 AE 2021 04 19 FINAL ER TITANIUM_FL11602- R13.P—df systems. Refer to ER Section 5.8.3 for. details. 2:) Refer to ER Sections 5 and 6 for other Limits of Use. Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32392 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under,Florida law, email addresses are public records. If you do, not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact'the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be, used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ... Credit Cartl .. 1 https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFcSK%2fTrZeHYB7UCe5KMr%2fsMfWgra38sP60YHMVvylw%3d%3d. Page 2 of 2 NEMOUetc. 353 Christian Street, Unit #13 ENGINEER EVALUATE TEST. CONSULT OnvemaCornUng Roofing And Asphalt, LLC -'_' '� �Evaluation Rep�U114 vw One OensCorn�gPorkvw�/ ^ ^ ' ` ` ` ` '�'^ FL11602-RI3 Toledo, OH436S9 ' � Date ofIssuance: 11/03/2008 (740) 321'6345��� � � ' Revision 14:04/19/2021 `^ ScoPs ` . This Evaluation' Report is issued under Rule 61G20'3 and the applicable rules and regulations the use of construction materials in the State of. Florida. The documentation submitted has been reviewed b Robert Nieminen, P.Efor use ofthe product under the Florida Building Code. The products described herein have been evaluated for compliance with the J*^Edition (2020) Florida Building Code sections noted herein. | DESCRIPTION: LAasumm: Labeling shall be inaccon1ance with the' ' ents of the Accredited Quality Assurance Agency noted herein and FBCi507.1'1. ' - - ' CONTINUED COMPLIANCE: This Evaluation R- - isvalid ' until such timeostna named � ' Qua|dv Asuuran6s or. production fod|by locaiiop(s). changes, or Code. ' 'dons that re�te t� the p,od | change. Acceptance of our Evaluation Reports by the named client constitutes agreement to notify NEK8O ETC. LLC of any changes to the product(s), the Quality Assurance or the production fod|ky1ocotion(s). NEyWO ETC, LLC requires a complete review ofits Evaluation Report ' relative` d dCode' 'derequirementsv�heachrode ` 1'p _- Florida Product -val Number (F��p� ,the.vmrds "NEKO|etc. Evaluated" may be displayed in advertising literature. If any'oEva ton oe �airt is displayed, thdn'it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report -shall be -.provided to the user by the. manufacturer or its distributors and -shall be available for insp6ction.-at the job site;at the�request of the Building Off icial.. ' This Evaluation RepoctConsists ofpages 1 8. Prepared by: � Florida Registration No. ss1a4Florida oCAAKE1gu3` . nmfaoIm I le sea I a p p ea ring w6 s . _--,P-on _-,-,-_;'�'_'_not -~--~. -----~--_ document CEFrriFICATION OF INDEPENDENCE: - 1. NEMo ETC, LLC does not have, nor does it intend to acquire or will itacqu' 'aOn"ncial interest in any co . pany ma"ufaoturingor distributing products uevaluates. 2. momoETc LLC bnot owned, operated orcontrolled byany company manufacturing o,distributing products it evaluates. 3. Robert mieminan, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. s. This is building code evaluation. Neither ms[mo ETC, LLC nor Robert mieminen, P.E. are, in anyway, the Designer ufRecord for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. @2018 NEMO ETC, LLC (NNEMOjetc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Titanium® Roof Underlayments, as produced by Owens Corning Roofing and Asphalt, LLC, have demonstrated compliance with the following section's of the 7t' Edition-(2020) Florida. Building Code through testing in accordance with applicable sections the following Standards. ;-.Compliance is,subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Sec#ion :°. _._. Pro e' . ...:: ; ' ', Standard ` ,: Year, 1504.3.1 Wind resistance UL 1897 2015 1507.1.1,1507.2.4, 1507.2.9.2 / R905.1.1, Material standard. ASTM D1970 2015 R905.2.8.2 1507.1.1A(2&3, Exception), 1507.1.1.1(5) 1 Tear strength ASTM D4533 " 2015 R905.1.1.1(2&3, Exception), R905.1.1.1(5) 1507.1.1.1(2&3, Exception), 1507.1.1.1(5) / Tensile strength ASTM D5035 2011: R905.1.1.1(2&3, Exception), R905.1.1.1(5). 1507.1.1.1(5) / R905.1.1.1(5) Liquid water transmission ASTM D4869 ' 2016 1507.3.3 / R905.3.3 Material standard FRSA/TRI, Sixth Edition 2018 TAS 110 Accelerated Weathering ASTM D4798 2011 Exahiination ;: Reference Date '' _.. ERD (TST6049) Various; system tests = >• 135520.06.11 06/15/2011 ERD (TST6049) .: Wind Uplift: .4 135520.,08.11-1 08/12/2011 . ITS (TST1509), FRSA/TRI, partial % 3126617COQ-005 10/31/2007 ITS (TST1509) ASTM D4869, LWT 101823107COQ-007A. 12/09/2014 ,.: Owens Corning Product equivalency Declaration 06/18/2018_ NEMO (TST6049) FRSA/TRI, tile slippage 4j-OC-19=SSUDL-01.A' 06/14/2019 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI (TST5878) FRSA/TRI, partial OCF-343-02=01 11/09/2017 PRI (TST5878) ASTM D4798, D1970 OCF-341-02-01 . 11/27/2017 .: PRI (TST5878) TAS 117(B); Pull -through OCF-422-02-02 04/03/2018 PRI (TST5878) FRSA/TRI, partial OCF-425=02-01 08/13/2018 PRI (TST5878) UL1897 1378TO02 07/10/2019 . PRI (TST5878) ASTM D1623, TAS 103 ' OCF-507-02-01 08/13/2019 PRI (TST5878) UL1897 1378TO117 10/20/2020 PRI(TST5878) ASTM D4533,D4798,D5035 1378TO110 10/15/2020 PRI (TST5878) ASTM 1)4533,D4798,D5035 137ST0111 10/15/2020 PRI (TST5878) ASTM D4533,D4798,D5035 1378TO112 10/15/2020 PRI (TST5878) ASTM D4533,D4798,D5035 1378T0059' 02/13/2020 PRI(TST5878) ASTM D8257-20 1378T0061 01/21/2021 PRI (TST5878) ASTM D4798, TAS 103 1378T0174 04/16/2021 ITS (QUA1673) Quality Control Service Confirmation 12/09/2020 ITS (QUA1673) Quality Control,,. Florida BCIS . Current NEMO ETC, LLC Evaluation Report 111980.11.08-R14 CertficateofAuthorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-1113 Titanlum® Roof Underlayments Revision 14: 04/19/2021 Page 2 of 8 4.1 ' 4.2 4.3 4.4 4.5 *,.NEMO l etc. so o Product Material„Standard Plaint(i) Description„ Titanium® PSU-30 ASTM D1970 and Dubai; UAE unreihforced polymer modified bitumen material FRSA/TRI 09-18 Brentwood, NH adhered to the underside of a polymer -coated, synthetic woven sheet. The underside is backed with a release film. Unit weight,24 Ibs/square Titanium® UDL-25 1507.1.1.1(2&3,. Qingdao, China ' synthetic sheet -type underlayment comprised of Exception), 1507.1.1.1(5) / a woven core coated on one side with a polymer R905.1.1.1(2&3; coating. Unit weight 2.5 lbs./square Exception); R905.1.1.1(5) Titanium® UDL-30 1507.1.1.1(2&3, Qingdao; China :synthetic sheet=type underlayment comprised of Exception), 1507..1.1.1(5) / a woven core coated on both sides with a R905.1.1.1(2&3, polymer coating. Unit weight 4.0 lbs./square Exception), R905.1.1.1(5) Titanium® UDL-50 1507.1.1.1(2&3, Qingdao, China ; synthetic sheet -type underlayment comprised of Exception), 1507;1.1.1(5) / a woven.core coated on both sides with a 11905.1:1.1(2&3, polymer coating. Unit weight 4.7 lbs./square -Exception), R905.1.1.1(5) Titanium® X30 1507.1.1.1(2&3, Qingdao, China synthetic sheet -.type Onderlayment comprised of Exception), 1507.1.1.1(5) / a non -woven polypropylene top scrim laminated R905.1.1.1(2&3, to a central. non -woven polypropylene scrim with Exception), R905.1.1.1(5) polymeric coating on the bottom side. Unit ASTM D8257 weight 5.0 Ibs:/square. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E..are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design: guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions_ (i.e., Broward and Miami - Dade Counties). '5.3 This Evaluation Report pertains to above -deck roof components: Roof decks and structural members shall be in 'accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations 'regarding roof assembly "fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Titanium® Roof Underlayments inai y `be 'used with -any prepared roof 'cover where the product is specifically referenced within FBC approval ,documents. If not listed,' a. request may be made to'the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared -roof covering. 5.6 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS 'FBC Section. , " : ' 1507 2 ; ,t �. ` " ;1507:3 1507.4 & L507 5 ` 1507:7 - Clay and Concrete The ' Underlayment Asphalt . ; Shingles IVletal Panels and Shingles Slate orSlate Wood Shingles and', " Mech'anlcal ; Adhesive r ,-Attach`s ,, Type Shingles Shakes Titanium® PSU-30 Yes Yes Yes Yes Yes Yes Qoint strips, 1507.1.1.3 / (See 5.6.1) R905.1.1.3) Titanium® UDL-25 Yes No No Yes Yes No " MEMO ETC; LLC Evaluation Report 111980.11.08-R14 Certificate of Authorcation #32455 7-1 EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-1113 Titanlum® Roof Underlayrnents Revision 14: 04/19/2021 Page 3 of 8 F NNIEM01 etc. TABLE 1: ROOF COVER OPTIONS FBC Section: , 150Z2 ISOZ3 1507.4 & 1507.5 "' 1507.7 1507.8 &,1507.19 Underlayment Asphalt, " Shingles 'Clay and Concrete Tile Metal Panels and,Shingles slate or Slate- Type Shingles,. Wood Shingles and' Mechanical -Attach' Adhesive - Set Titanium® UDL-30 , Yes Yes (Base Sheet In 2-plysystem) Yes (Base Sheet In 2-plysystem) Yes Yes No Titanium® UDL-50 " Yes I No I No Yes Yes No Titanium® X30 Yes No No Yes Yes No 5.6.1 Adhesive -set is limited to use of following underlayment / tile -adhesive combinations. TABLE IA: ALLOWABLE TILE ADHESIVE-/ UNDERLAYMENT COMBINATIONS' Underlayment Adhesive „Florida Product Approval Titanium® PSU-30 Dupont "Tile BondTM' Roof Tile Adhesive" FL22525 - ICP Adhesives and Sealants "Polyset® AH-160" FL6332 ICP Adhesives and Sealants "Polyset° RTA-1" FL6276 5.7 Allowable Substrates, . TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS Underlayment °;,Application Substrates (designed to meet wind loads for project) Type Primer' Materiaki;) ,,, Titanium® PSU-30 self -adhering Deck/ sheathing (Optional) ASTM D41 Plywood Base sheet None ASTM D226, Type II felt ASTM D41 Titanium® UDL-30 None Titanium® UDL-30 (inverted) 5,8 Attachment Limitations: " 5.8.1 For use under mechanically attached NON -TILE prepared roof coverings, attachment shall be in accordance with the manufacturer's installation instructions, but —for mechanically attached underlayments or base sheets - not less than FBC 1501.1.1 or R905.1.1. 5.8.2 For use- under tile roof systems, attachment shall be in accordance with the manufacturer's installation instructions, but not less than Section 5.8.3 herein. 5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications: The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRI Florida.High Wind Concrete and Clay Roof Ile Installation Manual, Sixth Edition. The Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). 5.8.3.1 Direct -to -Deck: The maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI Florida High Wind Concrete and Clay Roof Tile -Installation Manual, Sixth Edition, Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. i Refer to Tile Manufacturers or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 111980.11.08-R14 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-R13 Tltanlum® Roof Underlayments Revision 14: 04/19/2021 Page 4 of 8 (NNEMOletc. #1 Maximum Design Pressure =-45 psf: Deck: Min.15/32-inch plywood to meet project.requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 - -Underlayment:. One or two plies Titanium® PSU-30; self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink -shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #2 Maximum Design Pressure=-142.5 psf: Deck: Min.15/32-inch plywood to meet project requirements to satisfaction `of Authority Having Jurisdiction. Primer None Underlayment: One ply Titaniurn®'PSU-30, self -adhered and back -nailed max. 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga.; 1-5/8-inch diameter tin 'caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. 5:8.3.2 Mechanically -Attached Base Sheet: The maximum design .pressure for the selected assembly shall meet orexceed that required under FRSA/TRI Florida High Wind "Conerete and'Clay fioof;Tle Installation Manual, Sixth Edition; Appendix A, Table 1A or the critical (highest) design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3. Alternatively, -the maximum design, pressu re. for the selected assembly shall meet or exceed at least the Zone 1 design pressure determined in accordance with FBG1609 or FBC Residential Chapter 3. Elevated -pressure zones shall employ an attachment density designed.by.a qualified design professional to resist the elevated pressure ,criteria. Commonly -used methods are ANSI/SPRI WD1, FM Loss. Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137'. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 ;(February 2020) for enhancements:....., . j .. 3 NEMO ETC, LLC . Evaluation Report I11980.11.08-R14 Certificate ofAuthorkotion #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-R13 Titanlum® Roof Underlayments Revision 14: 04/19/2021 Page 5 of 8 NNEMOJetc. #5 Maximum Design Pressure =45 psf*: Deck: Min. 15/32-inch. plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium® UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium® PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin. caps in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #6 Maximum Design Pressure = -45 psf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium® UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less.than 3/16-inch with min. 32 ga., 1-5/8" diameter tin caps. Spacing: 6-inch o.c. at 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer: ' ASTM D41 primer required over printed side of UDL-30. Underlayment: - One or two plies, Titanlum® PSU 30, self -adhered and back -nailed 6" o.c. with 12 ga. galvanized annular rink shank nails through 32 ga., 1-5/8-inch diameter tin caps in accordance with Owens-Corning Roofing and Asphalt, LLC published installation requirements. . 5.9 Exposure Limitations: TABLE 3: EXPOSURE LIMITATIONS „ Underiayment Prepared.Roof,Cover Installation Type Maximum Exposure (days) • - ,, Titanium® PSU-30 Mechanically attached 180 Adhesive -set -tile 180 Titanium® UDL-25, Titanium® UDL-30, Titanium UDL-50, Titanium X30 Mechanically attached 180 5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope.shall be as follows. These slope limitations can only be exceeded by.using battens during loading of the roof tiles. . TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS U6d16rI yMent ;; . =Tile Profile Staging Method IVla�iimum Slope'„ Titanium® PSU-30 Flat Max. 10-tile stack 5:12 Flat Max 5-tile stack 6:12 Lugged Max. 10-tile stack 4:12 Lugged Max. 5-tile stack 5:12 Lugged Max. 10-tile stack (5 over 5) 5:12 MEMO ETC, LLC Evaluation Report 111980.11.08-R14 Certificate ofAuthorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-R13 Titanlum® Roof Underlayments Revision 14: 04/29/2021 Page 6 of 8 NNEMOJetc. 6.1 Titanium® Roof Underlayments shall.be- installed in accordance with Owens-Corning Roofing and Asphalt, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. - -. 6.2 Re -fasten any, loose decking panels;'and check for protruding nail heads.: -Sweep the substrate thoroughly to remove "any dust and debris'priorto application, and prirn6 the substrate (if Iapplicable). 6.3 . Titanium® UDL-25, Titanium® UDL-30, Titanium® UDL-50 or Titanium® X30: 6.3.1 . Shall be installed incompliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2, Exception), 1507.1.1.1(3, Exception) -or 1507.1.14(5) or FBC Residential R905.1'1.1(2, Exception); R905'.1.1.1(3, Exception) or R905.1.1.1(5) for the type of prepared .roof covering to be installed, and the manufacturer's installation instructions. FBC requirements take precedence over the manufacturer's installation instructions. 6.3.2 Fasteners: Minimum fasteners shall be corrosion resistant, ring -shank cap nails shall be as set forth in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3. 6.4 Titanium® PSU-30: 6.4.1 Non -Tile Applications: Shall be installed in compliance with requirements for an approved self -adhering underlayment (ASTM D1970) in FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering to be installed, and the manufacturer's installation instructions. When installed over a mechanically attached, FBC Approved ASTM D226 Type II felt, the felt shall be fastened in accordance with FBC 1507.1.1 or R905.1.1. 6.4.2 Tile Applications: Shall be installed in compliance with requirements for a Self -Adhered Membrane in the FRSA/TRI Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition, and the manufacturer's installation instructions. Refer to Section 5.8.3 for attachment limitations. Refer to Table 4 for tile staging limitations. 6.5 Titanium® 2-Ply System: 6.5.1 The TitaniumO 2-Ply System consists of a base layer of Titanium® UDL-30 (top -surface primed or sheet inverted) mechanically attached to the wood roof deck followed by TitaniumO PSU-30, self -adhered. 6.5.2 Non -Tile Applications: Install Titanium® UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium® PSU-30 in accordance with'Section 6.4. 6.5.3 Tile Applications: Refer to Section 5.8.3 for attachment limitations. Refer to Table 4 for the staging limitations. NEMO ETC, LLC Evaluation Report 111980.11.08-R14 Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-1313 Titanlum® Roof Underlayments Revision 14: 04/19/2021 Page 7 of 8 NINIEM01 etc. As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4 herein for.pi-oducts and production. locations having met codified material standards. Intertek Testing Services NA Inc. — QUA1673; .(312) 906-7779; maura.norlander@intertek.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 111980.11.08-R14 Certificate of Authorisation #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION FL11602-1113 Titanium® Roof Underlayments Revision 14: 04/19/2021 Page 8 of 8