HomeMy WebLinkAbout SITE MAP & VICINITY MAP Digitally signed
JOHN MUGGLI
``20y.'VtGEN8�c'.+�+�;; by Mindy Nicole
69779 r
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MINDY NICOLE NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM =. :�= O'Neal
OWFAL,PE ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS %gyp STATE OF :•v+" Date: 2 021.11.17
DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE 1 1 %+�F F[oEtoP•'•�?` 0ADD:7300RYAN DAIRY RD SUITE
MUST BE VERIFIED ON ANY ELECTRONIC COPIES. DC SYSTEM SIZE ( 1 1 . 5 6 K W) ��i��S�pNAL r t 400 SEMINOLE FL 33777,USA
11111111 j tt�\` 21:28:29 -05 00 CONTACT: 7275714141
LICENSE#AEC-07807
N SITE MAP (N.T.S)
SYSTEM DETAILS
w $ _ � y11F LORD&LAWRENCE
DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC _ �- ZZB� CONSULTING ENGINEER
SYSTEM WITH NO BATTERY STORAGE ����
4,•"A „
DC RATING OF SYSTEM SYSTEM SIZE:11.56 KW DC STC S - CONTACT:(561)444 8192
5700 LAKE WORTH ROAD SUITE 211
GREENACRES,FL 33463,USA
AC RATING OF SYSTEM 9.86 KW _, FLORIDA REGISTRY#33809
. r
;•r r
AC OUTPUT CURRENT 41.14 A
NO.OF MODULES (34)HANWHA Q.PEAK DUO BLK-G8 340W °
MODULES
r rt LLI
NO.OF INVERTERS (34)ENPHASE IQ7PLUS-72-2-US s} ''_ - f}Jq: U
r _
MICROINVERTERS W_
POINT OF CONNECTION LINE SIDE TAP IN THE MSP
E W Q
ARRAY STRINGING (1)BRANCH OF 12 MODULES U)
(2)BRANCHES OF 11 MODULES ,^ O
v O N
00
292'-9r_r _ __ __ - VICINITY MAP � co
SITE DETAILS z cn LL
Gopher RICec
IS"SETBAC ~3'SETBACK 5
ASHRAE EXTREME LOW 0°C
(E)MAIN SERVICE PANEL ROOF 3 ICeatney RdKeamey i O
o (INSIDE HOUSE) ROOF 2 w5t 5bq �� -" —
ASHRAE 2/e HIGH 33°C
(E)UTILITY METER y`
GROUND SNOW LOAD 0 PSF (OUTSIDE HOUSE)
£ m -Pllve St 6fVe St
WIND SPEED 160MPH(ASCE 7-16) a
RISK CATEGORY II ~
N
WIND EXPOSURE CATEGORY B 3 Sun Grove Montessori School It Nro 5t
620.Russ Rd,Fart Pierce,.,Rd LU
FL 34982,United States o
GOVERNING CODES ULi�Rai ul,� ul. R
l chctt 1:J
PV ARRAY
FLORIDA RESIDENTIAL CODE,7TH EDITION 2020(FRC) ROOF Z O
p F
FLORIDA BUILDING CODE,7TH EDITION 2020(FBC) a
FLORIDA FIRE PREVENTION CODE,7TH EDITION 2020(FFPC) L
UU
NATIONAL ELECTRIC CODE,NEC 2017 CODE BOOK,NFPA 70 _ 0
210' L
RU55 RD Wi2iIND FLOW MAP
° z
L" H
U
SHEET INDEX yl— a.h UU
oe
P
SHEET NO. SHEET NAME Orlando PERMIT DEVELOPER
A-01 SITE MAP&VICINITY MAP
O
N:s3
A-02 ROOF PLAN&MODULES V e Idd DATE 09/11/2021
a a �
S-01 ARRAY LAYOUT 7sbur FLORIDA ;E ft �cn DESIGNER CAN
S-02 STRUCTURAL ATTACHMENT DETAILS
i as°t� S
E-01 SINGLE LINE DIAGRAM 40.559 REVIEWER
E-02 WIRING CALCULATIONS eat ItIrr
Fort rs Bei Ch SHEET NAME
E-03 SYSTEM LABELING -
DS-01 MODULE DATASHEET LO SITE MAP &
DS-02 INVERTER DATASHEET 0 VICINITY MAP
a.- y� udo ale
mile I
DS-03 COMBINER BOX DATASHEET
DS-04 ATTACHMENT DATASHEET SHEET NUMBER
Verq s
/� _O w
DS-Os RACKING DATASHEET LAYOUT SUBJECT TO CHANGE al Park H I
BASED ON SIDE CONDITIONS