Loading...
HomeMy WebLinkAbout ROOF PLAN & MODULES N THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MINDY NICOLE O'NEAL,PE ON THE DATE ADJACENT TO IGNED NDSE LED AN THES OF THIS GNATU MODULE TYPE DIMENSIONS & WEIGHT GENERAL INSTALLATION PLAN NOTES: DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE , MUST BE VERIFIED ON ANY ELECTRONIC COPIES. NUMBER OF MODULES=34 MODULES 1N s MODULE TYPE= HANWHA Q.PEAK DUO BLK-G8 340W MODULES 1)ROOF ATTACHMENTS TO METAL ROOF SEAMS SHALL BE WEIGHT=43.87 LBS/ 19.9 KG. INSTALLED AS SHOWN IN SHEET S-01 AND AS FOLLOWS FOR Digitally signed EACH WIND ZONE:. ADD:7300 BRYAN DAIRY RD SUITE y ..• ' "•. O. % MODULE DIMENSIONS=68.50"X 40.55"= 19.29 SF 400 SEMINOLE FL 33777,USA S Q .•�1GENgF'•,1r -; b Mind Nicole CONTACT: 7275714141 No 69779 < � Y y NUMBER OF INVERTER=34 MICROINVERTERS WIND ZONE 1: MAX SPAN 4'-0"O.C. LICENSE#AEC-07807 O'Neal INVERTER TYPE= ENPHASE IQ7PLUS-72-2-US MICROINVERTERS WIND ZONE 2: MAX SPAN 4'-0"O.C. 4:= WIND ZONE 3: MAX SPAN 2'-0"O.C. 0 STATE OF (/�� Date. 2021 .11 .17 �;,t\ RIDp:.' ��� DC SYSTEM SIZE: 11.56 KW 2)EXISTING RESIDENTIAL BUILDING ROOF WITH MEAN ROOF SSro NALEt��` I AC SYSTEM SIZE: 9.86 KW HEIGHT 25 FT AND 2"X4"WOOD ROOF TRUSSES SPACED 24"O.C. LORD&LAWRENCE IiIIi��`� 21 :28:43 -05 00 CONSULTING ENGINEER AND METAL SEAM SPACING 9"O.C. CONTRACTOR TO FIELD VERIFY AND SHALL REPORT TO THE CONTACT:(561)444 8192 ENGINEER IF ANY DISCREPANCIES EXIST BETWEEN PLANS 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL 33463,USA AND IN FIELD CONDITIONS. FLORIDA REGISTRY#33809 1 CERTIFY THAT THE INSTALLATION OF THE MODULES IS IN COMPLIANCE WITH FBC: RESIDENTIAL CHAPTER 3.BUILDING STRUCTURE WILL SAFELY ACCOMMODATE LATERAL AND UPLIFT (E) BACK YARD WIND LOADS,AND EQUIPMENT DEAD LOADS. L w NOTES: J 0 1. LOCATION OF JUNCTION BOX(ES), AC C7 � U) 18"SETBACK ROOF ACCESS POINT X SETBACK DISCONNECTS(S), AC COMBINER PANEL(S), AND C7 Ow ni OTHER ELECTRICAL EQUIPMENT(S) RELEVANT TO � rn PV INSTALLATION SUBJECT TO CHANGE BASED It ROOF 2 ROOF 3 ON SITE CONDITIONS. U) -j (E) MAIN SERVICE PANEL w (INSIDE HOUSE) ■ ■ 0 ■ ■ 2. SETBACKS AT RIDGES CAN BE REDUCED TO 18 z� ■ ■ o INCHES IN COMPLIANCE WITH FBC R 324.6.2: (E) UTILITY METER ■ ■ ■ ■ ■ o TOTAL PLAN VIEW AREA= 3204.7 SQFT N (OUTSIDE HOUSE) TOTAL PV AREA= 34(68.50 1N)(40.55 IN)/(144 IN-2) C9 ■ ■ z (N)AC DISCONNECT ■ ■ = 655.84 SOFT ■ ■ ( 655.84 SQFT/3204.7 SQFT)100 =20.46 % (N) COMBINER PANEL ■ ■ Ln TOTAL PV AREA POPULATES 20.46 % OF TOTAL ■ ■ PLAN VIEW AREA AND IS WITHIN THE 33% W REQUIREMENT. o ° CONDUIT RUN U) z z O O U Oco ❑ ❑ LEGENDS z ■ ■ ■ ■ UM -UTILITY METER uj ■ ■ ■ ■ MSP -MAIN SERVICE PANEL ■ -M PERMIT DEVELOPER METER MAIN COMBO JB -JUNCTION BOX DATE 09/11/2021 ROOF ACCESS POINT ACD -AC DISCONNECT DESIGNER CAN ROOF i PM -PRODUCTION METER REVIEWER cP -COMBINER PANEL SHEET NAME PV ARRAY -FIRE SETBACK ROOF PLAN (E) FRONT YARD -MICROINVERTER & MODULES O -VENT,ATTIC FAN SHEET NUMBER (ROOF OBSTRUCTION)--- -CONDUIT /�"-02