Loading...
HomeMy WebLinkAbout INVERTER DATASHEET ADD:7300 BRYAN DAIRY RD SUITE 400 SEMINOLE FL 33777,USA Data Sheet Enphase IQ 7 and IQ 7+ Microinverters CONTACT: 7275714141 Enphase Microinverters LICENSE#AEC-07807 Region:AMERICAS INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V Peak power tracking voltage 27 V-37 V 27 V-45 V LORD&LAWRENCE Operating range 16 V-48 V 16 V-60 V ` ?CONSULTING ENGINEER Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A CONTACT:(561)444 8192 The high-powered smart rid-read Overvoltage class DC port II II 5700 LAKE WORTH ROAD SUITE 211 Enphaseg y GREENACRES,FL 33463,USA DC port backfeed current 0 A 0 A FLORIDA REGISTRY#33809 Enphase IQ 7 Micro and Enphase IQ 7+Micro" PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; Q7 and IQ 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ LLI IQ 7+Microinverters integrate with the Enphase 211-264V 183-229V 211-264V 183-229V U IQ Envoy'",Enphase IQ Battery",and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) W Nominal frequency 60 Hz 60 Hz I--I Enlighten"monitoring and analysis software. Extended frequency range 47-68Hz 47-68Hz J U) IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms (D Of Z) Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) (D O LL standards set forth by previous generations and Overvoltage class AC port III III :D00 undergo over a million hours of power-on testing, AC port backfeed current 18 mA 18 mA � � M Power factor setting 1.0 1.0 enabling Enphase to provide an industry-leading Power factor(adjustable) 0.85 leading...0.85 lagging 0.85 leading...0.85lagging z U) LL warranty of up to 25 years. EFFICIENCY @240 v @208 v @240 v @208 v ::) Peak efficiency 97.6% 97.6% 97.5% 97.3% O Qf CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% 0 O1771 N MECHANICAL DATA CO Ambient temperature range -400C to+65°C Relative humidity range 4%to 100%(condensing) Easy to Install Connector type MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Lightweight and simple Weight 1.08 kg(2.38lbs) Faster installation with improved„lighter two-wire cabling Cooling Natural convection-No fans r Built-in rapid shutdown compliant(NEC 2014&2017) Approved for wet locations Yes o Pollution degree PD3 Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor u) Optimized for high powered 60-cell and 72-cell*modules FEATURES O o More than a million hours of testing Communication Power Line Communication(PLC) U) a Monitoring Enlighten Manager and MyEnlighten monitoring options. > 0 Class Il double insulated enclosure w Both options require installation of an Enphase IQ Envoy. v, IY ww UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break O disconnect required by NEC 690. r Compliance CA Rule 21(UL 1741-SA) Smart Grid Ready UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, w CAN/CSA-C22.2 NO.107.1-01 > 4 Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and Ir frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements PERMIT DEVELOPER Configurable for varying grid profiles Meets CA Rule 21(UL 1741-SA) DATE 0 9/1 112 0 2 1 DESIGNER OAN *The IQ 7+Micro is required to support 72-cell modules. 1.No enforced DC/AC ratio.See the compatibility calculator at https,//enphase.com/en-us/support/module-com atp ibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. REVIEWER 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. � ENPHASE "To learn more about Enphase offerings,visit enphase.com ENPHASE SHEET NAME To learn more about Enphase offerings,visit enphase.com v ©2020 Enphase Energy All rights reserved.Enphase,the Enphase logo,En hase IQ 7,Enphase IQ 7+,Enphase IQ Battery, p gy g p p g p p p y INVERTER Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-01-06 DATASHEET SHEET NUMBER DS-02