Loading...
HomeMy WebLinkAboutSINGLE LINE DIAGRAM NOTE: 1.SUBJECT PV SYSTEMS HAS BEEN DESIGNED TO MEET THE MODULE SPECIFICATION INVERTER SPECIFICATIONS REQUIREMENTS OF THE NEC 2017,NFPA 70 AND THOSE SET FORTH BY THE FLORIDA SOLAR ENERGY CENTER CERTIFICATION,INCLUDING MODEL NO. HANWHA Q.PEAK MANUFACTURER ENPHASE MAXIMUM NUMBER OF MODULE STRINGS,MAXIMUM NUMBER OF DUO BLK-G8 340W MODEL NO. IQ7PLUS-72-2-US MODULES PER STRING,MAXIMUM OUTPUT,MODULE MANUFACTURER PEAK POWER 340 W MAX DC INPUT VOLTAGE 60 V AND MODEL NUMBER,INVERTER MANUFACTURER AND MODEL 0ADD:7300 DAIRY 7, SUITE RATED VOLTAGE (Vmpp) 34.34V MAX OUTPUT POWER 290 VA NUMBER,AS APPLICABLE. CONTACT: 7275714141 Im 2.PROVIDE TAP BOX IN COMPLIANCE WITH 312.8 IF PANEL GUTTER LICENSE#AEC-07807 RATED CURRENT ( pp) 9.90 A NOMINAL AC OUTPUT VOLTAGE 240 V SPACE IS INADEQUATE. OPEN CIRCUIT VOLTAGE (VOC) 140.70V NOMINAL AC OUTPUT CURRENT 1.21 A SHORT CIRCUIT CURRENT (Isc) 110.40A SOLAR ARRAY(11.56 KW-DC STC) (34)HANWHA Q.PEAK DUO BLK-G8 340W MODULES LORD&LAWRENCE (2) BRANCHES OF 11 MODULES ����-'CONSULTING ENGINEER (1) BRANCH OF 12 MODULES CONTACT:(561)444 8192 5700 LAKE WORTH ROAD SUITE 211 /I // GREENACRES,FL 33463,USA ��:F 0,��i� Digitally signed FLORIDA REGISTRY#33809 ' �CENg by Mindy Nicole No 69779 =* * *= O'Neal i�0 STATE OF Date: 2021 .11 .17 w NAL,��'c�'� 21 :29:06 -05'00' � w 200A � j 1 STRING OF (N)JUNCTION (E)MAIN SERVICE (D o N 12 MODULES WITH BOX (N)IQ AC PANEL LINE SIDE TAP oCO Df MICROINVERTERS COMBINER PANEL (N)60A AC 120/240V z U) CO u- ENVOY IQ DISCONNECT p Df CD 1 STRING OF FUSED 11 MODULES WITH 15A/2P (E)200A MICROINVERTERSLl 20A/2P 60A/2P 20A/2 P 20A/2P • • o 1 STRING OF UM 11 MODULES WITH G G G z Z MICROINVERTERS ENPHASE Lu Q CABLES (3)#10 AWG THWN-2-L1 (1)#10 AWG THWN-2 GND (3)#10 AWG THWN-2-L2 • • (1)#10 AWG THWN-2 GND IN 3/4"IMC,RMC,FMC,LFMC, (3)#6 AWG THWN-2 (3)#6 AWG THWN-2 W PVC,HDPE,NUCC,RTRC, (1)#10 AWG THWN-2 GND IN 3/4"IMC,RMC,FMC,LFMC, LFNC,FMT,ENT OR EMT IN 3/4"IMC,RMC,FMC,LFMC, PVC,HDPE,NUCC,RTRC, G N CONDUIT RUN PVC,HDPE,NUCC,RTRC, LFNC,FMT,ENT OR EMT LFNC,FMT,ENT OR EMT CONDUIT RUN PERMIT DEVELOPER CONDUIT RUN DATE 09/11/2021 DESIGNER OAN REVIEWER SHEET NAME PER FL.STATUE 377.705(REVISED 7/1/2017)I,MINDY NICOLE SINGLE O'NEALPE#69779,AN ENGINEER LICENSED PURSUANT TO LINE DIAGRAM CHAPTER 471,CERTIFY THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MINDY NICOLE APPROVED USING THE STANDARDS CONTAINED IN THE MOST O'NEAL,PE ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS RECENT VERSION OF THE FLORIDA BUILDING CODE. SHEET NUMBER DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. E-01