Loading...
HomeMy WebLinkAboutRoof packet 43320 (4) Section A (General Information). Master Permit No. Process No. Contractors Name: Total Home Roofing License# CM 330489 Job Address 155 NE Naranja AVE Saint Lucie West, FL 34983 ROOF CATEGORY ❑Low Slope ❑Mechanically Fastened Tile ❑Mortar/Adhesive Set Tiles ❑Asphaltic Shingles ❑Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance C4 Reroofing ❑Recovering . ROOF SYSTEM INFORMATIOM00 Low Slope Roof Area (SF) Steep Sloped Roof Area (SF) Total (SF) 4300 Section B(Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels,clearly identify dimensions of elevated pressure zones and location of parapets. mT i m,%.� r-i c -j I 1 I f- it1 . �l ------------------------------------------- N � LO +I LLJ LO -v � t} I.4} f LO I CW � SY Section D (Steep Slope Roof System) Roof System Manufacturer: Owens Corning Notice of Acceptance Number: FL10674-R16 Minimum Design Wind Pressures, If Applicable(From RAS 127 or Calculations): Zone 1:-74 Zone 2e:-74 Zone 2n-108 7one 2r-108 Zone 3e-108 Zone 3r:-128 Deck Type: Wood Type Underlayment: Weatherlock Roof Slope: 3 12 Insulation: N/A Fire Barrier: N/A Ridge Ventilation? Fastener Type &Spacing: 1 1/4" Ring Shank Nails yes Adhesive Type: N/A Type Cap Sheet: N/A Mean Roof Height: 15' Roof Covering: I Asphalt Shingles Type&Size Drip 3" X 3" Galy Alum, Edge: